Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | ₹15.2 L | L1 | Accepted-AOC LOWEST QUOTED BIDDER |
| 2 | L2₹15.5 L+₹23,860.45 (1.57%)Rejected-Finance | ₹15.5 L+₹23,860.45 (1.57%) | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 3 | L3₹16.2 L+₹92,444.85 (6.07%)Rejected-Finance | ₹16.2 L+₹92,444.85 (6.07%) | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 4 | L4₹16.3 L+₹1.0 L (6.81%)Rejected-Finance | ₹16.3 L+₹1.0 L (6.81%) | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 5 | L5₹18.5 L+₹3.2 L (21.3%)Rejected-Finance | ₹18.5 L+₹3.2 L (21.3%) | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
17 Jul 2024, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD
PROVISION OF STORAGE SHED AT BSO YARD AT AFS HAKIMPET
2024_MES_660629_1
84769/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF HAKIMPET
As per NIT
9 documents required · 9 mandatory
₹500
GE AF HAKIMPET
₹33,000
Yes
9 Sept 2024
19 Jun 2024
19 Jul 2024
19 Jun 2024
17 Jul 2024
3 Jul 2024
19 Jun 2024 - 29 Jun 2024
Amount
SCHEDULE 'A' PART -I (B/R PORTION) :- Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/ dense soil complete all as specified and as directed.
Excavation in post holes each n.exc 0.50 cum getting out. Returning filling in layers n.exc 25cm etc removal at surplus soil to a distance n.exc 50 mt and making good surface in hard/ dense soil complete all as specified and as directed.
M&L Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) laid in base, mass concrete complete all as specified and as directed.
M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L 100mm thick Plain Cement concrete type C-2, 1:3:6 (40mm graded aggregate) Laid in flooring complete all as specified and as directed.
M&L 75mm thick Plain Cement concrete type B-1, 1:2:4 (20mm graded aggregate) Laid in flooring Finishing cement concrete surface even and smooth with using extra cement complete all as specified and as directed.
S&F Steel work as in tubular / L post trusses,plates, purlins including special shaped washers etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St 240 complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surfaces of any description including preparation complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated / semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L Brickwork with fly ash modular bricks straight or curved onplan exc 6 m mean radius in CM1:6 complete all as specified and as directed.
M & L for Rendering 10 mm thick on fair faces of brick work or concrete wall surfaces in CM 1:4 finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering to brick masonry surfaces or surfaces 15mm thick in cement mortar 1:4 complete all as specified and as directed.
M&L applying 2 coats of oil bound Distempering over a coat of primer including preparation of plastered wall surfaces white or tinted complete all as specified and as directed.
M&L for applying two coats of cement based paint paint on walls including reparation of new plastered surfaces over a coat of primer complete all as specified and as directed.
Forming Contraction (Dummy) joints 40mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed.
S&F Fe 410 -W (Gde- E- 250) quality- A Framed work as in doors windows or gates of angle or other section with plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings including fastening and fixing complete all as specified and as directed.
Providing cast-in-situ reinforced cement concreteType B1 1:2:4 (20mm graded aggregate) in copings,columns, etcincluding use of form work (straight or curved), including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for Mild steel TMT bars 6 mm to 8 mm dia and ., cut to length, bent to shape required including crancking , bendding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed.
M&L 75mm thk Plain Cement concrete type B-1, 1:2:4(20mm graded aggregate) Laid in plinth protection including Grade B joint filling complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average with of aperture 1.4 0 mm and fixed with stainless steel wire staples complete all as specified and as directed.
SCHEDULE 'A' PART -II (E/M PORTION) :- M&L for point wiring with using 1.5 Sqmm (nominal area) multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC conduit / casing and capping of adequate size fixed on surface with PVC rawl plugs with sunken type pressed steel terminal box/PVC boxes and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes/PVC boxes of any shape and size modular white colour cover plate with frame
One lightr point controlled by one,one way switch.
One Ceiling fan/exhaust fan point controlled by one, one way switch
One 3 pin socket out let 5 amp point on the (same board) with other switches.
One 3 pin socket outlet 5 amp point on the independent board
Description all as per item No. 22 above here-in-before but with 4 sq mm size FRLS pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board complete all as specified and as directed.
S&F ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and as directed.
Supply and fix switch piano flush type 6 Amp, one way complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1 3 pin 6 amps flush type universal complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1,3 pin 6 and 16 Amps flush type universal complete all as specified and as directed.
Supply and fix stepped type electronic ceiling fan regulator complete all as specified and as directed.
Supply and Fix Wall Mounted Box Type LED Batten suitable for 18/20 Watt with LED Lamp along with integrated driver complete with 2 Nos round block with necessary arrangements and connecting to the point wiring with necessary flexible copper conductor of multistranded three core 1.5 sqmm of suitable length from fitting to the ceiling rose complete all as specified and as directed.
S & F sheet metal enclosure powder painted vertical type MCB DB TPN 04 way double door including MCCB 63 Amps IP-42 protection and busbar 200 Amps with Din rail and busbar complete all as specified and as directed.
S&F MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and as directed.
M/L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 6 Sqmm drawn through PVC conduit/casing capping including accessaries with 6 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up complete all as specified and as directed. Note : - 2 runs of cable and one run of earth wire and conduit /Casing & Caping will be measured as one length.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified and as directed. NOTE :- Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and fix Earth continuty conductor or main earthing lead fixed to wall on batten or recess or chasses in ground or drawn in conduit/pipe or fixed to pole or any other indicated situationfor loop earthing etc as reuired 4 mm dia galvanised iron complete all as specified and as directed.
Supply and lay on wall / in ground /on pole ISI marked LT XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 35 sqmm 3.5 core complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
M & L for spreading cleaned dry river sand filling in trenches for cushioning of LT/HT cables punning after filling complete as specified and as directed. Note :- Punned thickness shall only be measured and paid
Supply and lay sub class B bricks old size laid flat adjacent to each other perpendicular to cable with width equal to length in trenches for protection of under ground cables complete all as specified and as directed
Supply and lay pipe galvanized, "Light grade", including fittings 40 mm dia complete all as specified and as directed
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with suitable no of nuts, bolts and clamps complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated soil not exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Allied Constructions (BID ID -3065239)
NEWS CONSTRUCTIONS (BID ID -3065427)
AMK Builders (BID ID -3056085)
SRI LAXMI SREENIVASA BUILDERS (BID ID -3056262)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .