Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-Finance NOT AVAILABLE | L1 | Accepted-Finance Being Lowest Tenderer | |
| 2 | L2₹33.7 L+₹5.7 L (20.2%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹36.7 L+₹8.7 L (31.0%)Rejected-Finance | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹38.4 L+₹10.3 L (36.7%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Being other than Lowest Tenderer | |
| 5 | L5₹40.1 L+₹12.1 L (43.0%)Rejected-Finance | L5 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹45.0 L
EMD Value
₹90,000
Closing Date
28 Oct 2023, 6:55 pmClosed
Lt Col Ng Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8973 SPL REPAIR TO BLDG NO P 53 PWSS AT INS KUNJALI UNDER GE NW KUNJALI PROVN OF ROLLING SHUTTER FOR FRESH POINT INCLUDING CONNECTED WORKS AT BASE VICTUALLING YARD MUMBAI AND PROVN OF PCC FLOORING IN STORE SECTION V OF BUILDING NO A 29 AT NAD MUMBAI
2023_MES_622230_1
8973/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) Kunjali
All as per tender Documents
6 documents required · 6 mandatory
₹0
₹90,000
Yes
10 Nov 2023
7 Oct 2023
30 Oct 2023
9 Oct 2023
28 Oct 2023
14 Oct 2023
7 Oct 2023 - 9 Oct 2023
Amount
M&L for roughening surfaces of old concrete surfaces by picking, sweeping cleaning and washing down with water to remove dust etc including taking down tarfelt and 15 mm thick screeding in cement mortar 1:4 finished even and smooth without using extra cement including mixed with water proofing compound as per manufacturer instructions (WPC shall be measured and paid separately).
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for all as directed.
M&L for cement concrete 1:2:4 type B-0(using 12.5 mm graded stone agg) on roof surface as a leveling course all as specified and directed.
M&L for applying a coat of bituminous primer 1.20 Kg/Sqm on prepared surface of plaster as per manufacturer's instructions, manufactured by the same agency of APP membrane. After applying of bituminous primer applying evenly a coat of bitumen 85/25 at the rate of 1.2 kg per sqm inc l clejaning surfaces. Providing and laying five layered 4 mm thick APP (Atatic poly propylele) modified polyester reinforced water proofing membrane with minimum weight of 4.60 Kg/Sqm, as specified here-in-after. The APP membrane shall be laid using torch on application with minimum 100 mm side overlap and 150 mm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. The APP membrane shall be taken upto minimum 200 mm on vertial surfaces. The edge of the membrane shall be sealed with sealant. The rain water gutter portion shall be finished with cement mortar 1:4 to provide requisite slope towards rain water pipe outlet. Notes :- (i) Irrespective of lap the net covered area shall only be measured and paid (ii) The quoted rate shall be deemed to be inclusive of bituminous primer and a coat of bitumen 85/25 at the rate of 1.2 Kg per Sqm for APP membrane on roof of G+4 tower omplete all as specsified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
M&L for erection two legged MS pipe /bamboo scaffolding incl fixing of hessian cloths, plywood covering to windows (wherever required) etc complete as instsructed and directed by the Engineer -in-Chargening. (Note : Same scaffoljding shall be used fsor external surfaces painting).
Relieving structural members such as columns, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel pjrops, frames etc including pjroviding necessary timber runners, bracing, jacking up arrangement all complete to the satisfaction of Engineer-in-Charge (Removing and redoing of brickwork, if required shall be paid separately).
Cutting out concrete blocks, slabs, brickwork or stone masonry (in alternate course) fsorming toothings for and bonding new work in mortar into old work including new materials entering old wall.
Chipping off existing loose, damaged Concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades, etc beyond main reinforcement (if required in the opinion of the Consultant). Carefully with chisel and hammer Providing and applying 'Rusticide SS' Rust passivator or equivalent as specified in the Brand Names to existing reinforcement bars Including wire brushing of reinforcement, cleaning washing of concrete etc complete as directed. Providing and applying two coats of rust preventor slurry made out of "Polyalk Fixoprime" or equivalent as specified in the Brand Names and cement in proportion 1:1:5 to existing reinforcement bars as directed complete. Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and reinforcement substracts complete as directed Providing and applying " Polyalk IP" or equivalent as specified in the Brand names, Polyment modified cement mortar in Required proportions (1:5:15) to RCC members Including Hand packing, curing and making the surface rough for plastering.
FILLING AND REINSTATING OF SEPARATION CRACKS Opening the Separation Cracks at the Junction of RCC and Masonry where ever directed and instructed into "V" Grooves 2" to 3" from the either side of the cracks by carefully marking the areas to be opened up using a Cutting machine and skillfully/carefully Chiseling with a well sharpened chisel and hammer as directed incuding wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed.
Moisteninig the Cracks, Providing and applying priming/bonding coat of slurry made out of "Polyalk EP" and cement (or equivalent as specified in the List of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the Cracks/Grooves by Providing and applying "Polyalk EP" Polymer modified cement mortar (or equivalent as specified in the List of Brand names) in Proportion of 1:5:15 (Polyalk EP: Cement: Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster Including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete as per specified and directed.
Drilling holes of required size upto 16 mm Diameter and upto 50 mm depth in concrete and cleaning the same as directed.
Providing and fixing 12mm diameter aluminium /PVC injection nipples and securing the same as directed & Providing and injecting cementitious grout using CEBEX-112 additive of 'Fosroc' at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete.
Providing and fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing. Micro concreting as per Consultants Instructions and directions.
Providing, cutting, bending and fixing Additional Reinforcement in postion steel reinforcement of specified/required sizes and shapes in the form or main rebars, stirrups & rings, distribution rebars etc., and tying them to shear connectors using GI binding wire. The additional rebars should be coated with Two coats of Anti Corrosive protective coating & dry sand to be sprinkled on second coat including typing with Annealed Binding wires, providing cover blocks of appropriate sizes etc complete as specified and instructed by the Conslutants.
Providing and laying Super fluid Microconcerete-Roffe crete repairs (or equivalent as specified in the List of Brand names) in beam bottoms, columns, slabs etc. including mixing with 5 mm to 10mm size aggregates, waterproof ply wood/steel plate shuttering, pouring, temping, consolidating, curing etc complete as per Manufacturer's specification and Consultants Instructions. The item shall be paid on actual consumption of Micro concrete.
Demolition of brick/stone masonry built in CM. all as specified.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 all as specified.
M&L for brick work with sub class 'B' bricks , straight or curved on plan to any radius in half brick thick wall built in cm 1:4.
Demolition of reinforced cement concrete in roof floor (other than ground floors) beams staircase, landing chajja and similar work complete all as specified.
M&L for reinforced cement concrete 1: 1.5: 3 for facias, louvers, parapets, railing, coloumns and beams etc incl form work all as specified and as directed
M&L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia.
All as per srl item No- 22 above but 5mm dia and over including 10mm dia in stirrups, spaces and binders etc all as specified.
Taking down cement plaster of any description on brick, stone or concrete surfaces of walls including raking out joints, hacking for key, scrubbing down with water upto 3 rd floor of bldg incl scaffolding complete all as specified and directed.
S&F mild steel fabricated welded mesh to concrete or brick work surfaces with nails or directed by the Engineer-in-Charge weight n.exc 4 Kg/Sqm.
M&L for rendering 20 mm thick pre polymer modified ready mixed cement based plaster in two coats 12 mm thick base coat and 8 mm thick finishing/final coat. Polymer modified ready mixed cement based plaster should having minimum composition of cement & sand 1:4 using fully treated dry, well graded natural sand conforming to IS-383 suitable for external plastering having low rebound properties, low water demand for curing properties, mechnical mixing with water in a matalic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces incl using richer mix for making corners if necessary incl making grooves of existing size and necessary
M&L for rendering 15 mm thick pre polymer modified ready mixed cement based plaster on wall surfaces Polymer modified ready mixed cement based plaster should having minimum composition of cement & sand 1:4 using fully treated dry, well graded natural sand conforming to IS-383 suitable for external plastering having low rebound properties, low water demand for curing properties, mechnical mixing with water in a matalic tray only to made good, consistency as per the specification of the manufacturer and applied over interior masonry and concrete surfaces incl using richer mix for making corners if necessary incl making grooves of existing size and necessary complete all as specified and directed.
M&L for rendering 10 mm thick pre polymer modified ready mixed cement based plaster on ceiling surfaces such as projected chajjas and roof ceiling etc. Polymer modified ready mixed cement based plaster should having minimum composition of cement & sand 1:4 using fully treated dry, well graded natural sand conforming to IS-383 suitable for internal plastering having low rebound properties, low water demand for curing properties, mechnical mixing with water in a matalic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces incl using richer mix for making corners if necessary incl making grooves of existing size and necessary all as specified and directed.
M&L for Rendering 15mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified.
M&L for Rendering 10mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified.
M&L for Rendering 15mm thick on brick work or concrete surface in cement mortar 1:4 finished even and fair incl mixing water proofing compound ( WPC measured and paid seperately) all as specified and directed.
Supply only integral water proofing compound.
Roughening surfaces of old concrete floor by picking , sweeping clean and washing down with water to remove dust etc.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing ) and rabbish of the premises.
Dismantling stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5mm graded aggregate as in floor finished even and fair all as specified.
M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exc. 0.11 Sqm but n. exc. 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface incl 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. Note : Engr-in-Charge.
M&L double charge premium quality light shade virified ceramic tiles 10mm thick (600 x 600 mm) polished area of each tiles not exceeding 0.36 Sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including 15mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 complete all as specified and directed.
M&L double charge premium quality light shade virified ceramic tiles 10mm thick (600 x 600 mm) polished area of each tiles not exceeding 0.36 Sqm, as in skirting /vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including 15mm thick backing coat in CM 1:4 complete all as specified and directed.
M&L for (450mm x300mm ) x 7 mm thick coloured glazed ceramic tiles as in dado/vertical services set and jointed in neat cement slurry and pointed in coloured cement to match the surface incl 15 mm thick backing coat in cm 1:4 complete all as specified and directed.
M&L for 20 mm thick granite maching cut as in steps, window cills, cooking platform, working table, jambs/risers etc and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, polishing, rounding of edges and 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. (colour of granite will be decided by the GE/Engr-in-Charge).
M&L for machine cut cudappa stone slab 20-25 mm thick fixed independently and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M &L for 18 to 20 mm thick machine cut kota stone slab as in flooring, window cills, jambs, soffits etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M &L for machine cut kota stone slab 18 to 20 mm thick as in risers jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 15 mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
M&L for 150mm wide strip of makrana white marble 20mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting , polishing and 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Rounding to edges of stone slabs on edge, such as in steps, cooking platform and making grooves for lining and other similar work complete all as specified and directed.
M&L for 40 mm thick cement concrete type B-1, 1:2:4 (20 mm graded stone agg ) as in floor finished even and fair complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge or thickness incl Nainital or similar pattern roof coverings all as specified and directed.
M&L for rolled mild steel section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors ; fixed with angle cleats or other connecting plates conforming to grade Fe 290 (Gde-E-165) incl one shop coat of zinc chromate primer incl preparation of surfaces complete all as specified.
All as per Item No 51 above but fixing only.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, fixed with self tapping screws as specified.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter, ridge and fixed with crumple joint etc fixed with self tapping screws all as specified and directed.
S&F plates (plain or chequered ) Fe-290(Gde-165) including cutting, forming holes and welding etc all as specified and directed by the Engr-in-Charge.
Taking down shutters of any description exc 1 sqm and n exc 2 sq.m each
Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame)
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame)
S&F 2nd class hard wood (sal) plain, solid, straight chawkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified.
S&F 35mm thick factory made 2nd class HW rail & stile plain framed , panelled shutter ( two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 ( Part I), kiln seasoned and chemically pressure treated
S&F factory made, 2nd class hard wood 35 mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauze etc all as specified and directed.
S&F 40 mm thick flush shutter solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F factory made PVC door frame (Choukhat) of the size 50 mm width, 47 mm height with a wall thickness of 5 mm made out of extruded 5 mm thick PVC sheet of density 600 Kg/Cbm manufactured by an ISO-9001-2015 certified comany, having pattam width of 50 mm and thickness of 10 mm. All three frame lengths reinforced with 19 mm x 19 mm MS square tube of 19 gauge, mitre cut at two corners and joined with 2 Nos of 150 mm long brackets of 15 mm x 15 mm MS square tube or joint by fusion heat welding. The door frame shall be fixed to the wall using 8/100 mm long MS screws through the frame by using PVC fasteners. A minimum of 4 NOs of screws to be provided for each vertical member & minimum 2 Nos for horizontal member etc complete as per manufacturers specification and direction of Engineer-in-Charge.
S&F 30 mm thick factory made moulded door shutter wood free consisting of frame made out of MS tubes of 19 gauge thickness and size of 20 mm x 40 mm for stiles as well as top, bottom & lock rail. MS frame shall have a coat of metal primer of approved make & manufacturer. The inside panel shall consist of 20 mm thick multichamber hollow PVC section of 1 mm wall thickness, bonded using solvent cement/eynoacrylate adhesive with 5 mm thick moulded PVC sheet of density 600 Kg/Cbm manufactured by an ISO - 9001-2015 certified company with 2, 4, 6 raised panel design in plain/prelam colours after routing the moulded design on one side of the inside panel 5mm plain /prelam PVC sheet to be pasted using solvent cement /eynoacrylate adhesive on other side of the hollow PVC section. All the four edge of the panel to be sealed with lipping of 10 mm thick & 20 mm wide PVC sheet baton (made by sticking 2 Nos foam PVC sheets of 5 mm thickness using PVC solvent cement adhesive. Door edge lipping to be painted with PVC ink of matching colour of plain/prelam moulded PVC sheet of door 20 mm thick (5 mm x 4 Nos ) thick PVC sheet to be given for lock provision at lock height . Door to be fixed with frame with 3 Nos stainless steel butt hinges of size 100 mm x 25 mm x 2 mm and 50 mm long steel screws drilled suitable to pass through both the walls of the MS tube other hardwares should be fixed with 20 mm x 8 mm size steel screws etc complete as per direction of Engineer-in-Charge, manufacturer's specification and drawing.
S&F powder coated aluminium of various section as required for doors, window, window openable shutters, partition, hook and eye, alu blade for louvered glass etc including fixing and making the frames or shutters to receive glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement, handle, tower bolt for shutter, sealant and aluminium hinges 02 Nos for each openable window shutters and 03 Nos for door shutters complete all as specified and as directed by Engr- in- charge. (alu handle, tower bolt and hinges shall be powder coated aluminium)
S&F aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 104, 7.5 mm thick all as specified and as directed by Engr- in- charge.
Hacking out old broken glass (any thickness, size, quality or description) from iron frames glazed with putty or wooden beads complete all as specified.
S&F 3mm thick sheet glass froasted or obscured one side and glazing with oil putty or wooden beads in square area n.exc 0.5 Sqm in each pane complete.
S&F aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples all as directed.
S&F in repairs aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed to existing aluminium window shutters with aluminium beading or wire staples all as specified and directed.
S&F 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts all as specified.
S&F for aluminium anodized barrel tower bolts 150 mm of extruded section and fixed.
S&F 150 mm size aluminium alloy handles, febricated type extruded section, ISI marked all as specified.
S&F butt hinges 100 mm mild steel hinges medium weight and fixed.
M & L for MS flat for hold fast. Grills and gratings etc Conforming to Fe-310-0 or Fe-410-0
S&F in repairs fancy type drapery rods, powder coated aluminium of 20-25mm size with fixing brackets, Knobs rollers etc.all as specified.
S&F in repairs 100 mm bore cast iron 'P' trap all as specified and directed
S&F in repairs 100 mm bore cast iron sanitary connection short connections pipe of length upto 300 mm
S&F in repairs 100 mm dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed.
Taking down PVC wastage and rainwater and down tak pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc complete all as specified and as directed.
S&F 50 mm bore low density polyethylene pipes (HDPE) of pressure rating 6 Kg/cm2 fixed to wall or laid in trenches including fixing clips, bends, elbows, shoes etc complete all as specified and as directed.
S&F in repairs 110 mm bore PVC bend with access door all as directed
S&F PVC (SWR ) vent cowl for 110 mm bore pipe
S&F stack clamps for any dia of pipe ('U' type ) out of 55 mm by 5 mm flat iron and 16 mm dia round iron stays, incl bolts and nuts and securing ends of stays to wall or roof all as directed.
S&F in repairs vitreous china wash down water closet pan coloured (pedestal pattern) including plastic sheet cover with nuts and bolts etc all as specified and directed. (Make -Jaquar)
S&F in repairs water closet squattin pan (Orissa pattern) 580x440mm, white with integral foot rests including connecting to trap and to flushing pipe antisyphonage pipe including making good to floor (excluding flushing cistern and flush pipe) (Make - CERA).
S&F vitreous china wash hand basin flat back of size 550x400mm including bracket, brass chromium plated waste coupling of 32 mm bore and padestal complete as fixed in repair (Make - CERA).
S&F under counter wash hand basin incl chromium plated brass waste coupling and PVC waste pipe complete all as directed Make - Jaquar CAT PART NO- CNS-WHT-705.
S&F 10 ltr capacity PVC syphonic action type flushing cistern low level white with inlet, ball valve, float and handle including connetion to pipe but fixed in repair complete all as specified. (Make -JAQUAR/CERA)
Supply only flush pipe of PVC 32 mm dia for low level cistern.
S&F in repairs CP towel rail 600 mm long between flanges and 20 mm dia ' D' type all as specified and directed.
S&F health faucet ABS Body with 8 mm dia 1 mtr flexible tube and wall hook (Make - Jaquar).
S&F in repairs fancy type CP Pillar cock/Push cock 15 mm bore all as specified and directed (Make - Jaquar/CERA).
S&F in repairs fancy type CP bib cock/Push cock 15 mm bore all as specified and directed (Make - Jaquar/CERA).
S&F in repairs fancy type CP angular stop cock with wall flange of 15 mm bore all as specified and directed (Make - Jaquar/CERA).
S&F overhead shower of 100 mm round shape single flow (ABS Body chromium plated with gray face plate) with rubit cleaning system ( Make- Jaquar CAT PART NO- OHS-1989) all as specified and directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450mm
Taking up or down existing GI water tubing complete with all fittings of 15 mm bore
Taking up or down existing GI water tubing complete with all fittings of 20 mm bore
S&F GI tubing medium grade with all fittings like Tee, bend, elbow etc, 15 mm bore fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F GI tubing medium grade with all fittings like Tee, bend, elbow etc, 20 mm bore fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks exc 500Ltr and n.exc 1000.00 ltr capacity all as specified and directed.
S&F rotational moulded polyethylene water storage tank of 1000 Ltr capacity (Loft tank/) hoisted and fixed in position all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 (12.5 mm graded stone agg) as in surface channels and drains all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (20 mm graded stone agg) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm inheight, copings, kneelers, apex stones, bed plates etc all as specified and directed by the Engr-in-Charge.
Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of 1 to 2 mm thick wall care putty and primer incl preparation of surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coat white wash on ceiling all as specified and directed by the Engineer-in-Charge.
M&L for preparation of old painted wooden surfaes of any description over 10cm width or girth and applying one coat of synthetic enamel paint.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint.
M&L peparation of old surfaces of walls soffits, facia roof and applying one coat of weather proof acrylic based paint (100% acrylic) etc all as specified.
Complete removal of existing treatment on wall, soffits, facia roof and applying two coat of weather proof acrylic based paint 100% acrylic paint over a coat of cement based primer complete all as specified and directed.
Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down and applying two coats of oil bound distemper over a coat 1 to 2 mm thick wall care putty (JK/Birla ) and primer incl preparatiomn of surfaces complete all as specified and directed.
Preparation of newly plastered surfaces of walls soffits, facia roof and applying 2 coats of weather proof acrylic based paint 100% arylic apex Ultima over a coat of cement based primer complete all as specified and directed.
M&L for preparation of newly wooden surfaes of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer incl preparation of surfaces.
M&L for preparation of old concrete surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M&L for preparation of old concrete surfaces of ceiling and applying two coats of white wash on ceiling all as specified and directed.
M&L for preparation of newly steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint all as specified and directed.
M&L for 50 mm dia and 350 mm long medium grade GI pipe spouts with wire gauge on inside mouth to be fixed before water proofing treatment of sunken slabs by cleaning RCC slab surface floors and walls by wire brush and rendering 6 mm thick in CM 1:4 mixed with integral WPC on uneven surface to make it even. Fill it water and check for dampness and seepage, all junctions points of side walls where CI/GI pipe are passing shall be sealed with epoxy mortar. Apply two coats of polymer modified cementious water proofing coating of minimum thickness of 1 mm each layer as per manufacturers instructions on floor & walls (upto 100 mm above FFL) and spray coarse sand on surface when the second layer is still sticky. Apply 20 mm thick plaster in CM 1:4 mixed with integral WPC of approved make on floors and walls including rounding of corners and junctions stoping towareds spouts. All pipes laid in sunken portions shall be covered with 50 mm thick PCC 1:3:6 all around after painting with anti corrosive black japan paint on GI/CI pipes. Test the water proofed area by filling water at least 72 hours and tested for leakage/seepage for the entire satisfaction of GE. After above said treatment apply two coats of hot blown bitumen @ 1.5 Kg /Sqm for each coat and laying 50 micron black polythene film in floors complete all as specified and directed. (Note : If leakage/Seepage occured after filling water at least 72 hours, the above said treatment will be re-done completely)
M&L for cement concrete 1:3:6 type C-2 , (20 mm graded stone agg) as in foundation filling and sunken floors etc all as specified and directed.
Removing demolished materials (Old concrete) exc 1.5 Km but n.exc 15 Km and deposited where as directed.
M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
S&F Stainless steel pipe railing all as specified and directed by the Engineer-in-Charge
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets etc all as directed.
M&L for false ceiling made out of 600x600x 4 to 6 mm thick ceiliing board / tiles deep panel suspensor system made out of powder coated GI sheet main tee of size 23.50x40x0.63mm and cross tee of size 23.50x23.50x0.63mm and angle size 19x19x0.63mm including 3mm GI wire for suspending bolts necessary washers nut/clits/pin hook etc. for securing frame work to ceiling to the snap grid all as directed by Engr-in-charge including provn of necessary holes / cuttings for providing light/fan as required including making necessary recesses / projected pattern complete all as specified and as directed. (Make -Armstrong/Chanakya/Everest.
S&F Rolling shutter with ball bearing, thickness of laths 1.25mm as specified including top cover, anchoring rod, hasp and staple, gear box,etc gear operated type with chain wheel and hand chain and one shop coat of primer erected in position as directed.
M&L for preparing new or previously untreated surface of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer Complete all as specified and directed.
Taking down cement or cement lime plaster, of any description on brick or stone walls etc including racking out joints, hacking for kry, scrubbing down with water etc including all necessary scaffolding as required and rubbishing off the premises etc complete all as specified and as directed.
M&L Plastering 15mm thick in CM 1:6 on brick surfaces, finished with Neeru finish on walls complete all as specified and as directed .
Rendering 20mm thick in two coats (15mm inner coat 5mm finishing coat) on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions incld scaffolding for high rise bldgs etc complete all as specified and as directed (WPC to be measured and paid seperately)
M &L for machine cut kota stone slab flooring 18 to 20 mm thick as in steps, landings, floors etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing incld making 2 Nos grooves in steps over & inclusive 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M &L for machine cut kota stone slab 18 to 20 mm thick as in skirting/vertical surfaces jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 15 mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall, soffits, facia roof and applying two coats of weather proof acrylic based paint (100% acrylic) over one coat of cement based primer with necesssary scaffolding for high rise bldgs complete all as specified and as directed
surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil
Removal of surplus excavated soil to a distance exe 100m but n.exe 150m. And depositing as directed
hardcore of broken stone or boulders guage exc n. exc. 63 mm, deosited, sread and levelled in layers n exsc. 15 cm thick, watered and rammed to a true surface (75 mm thick).
cement concrete in foundations type D-2 1:4:8 40 mm graded aggregate in foundations (75 mm Thick).
M & L PCC (1:2:4) type B2 100mm thick as in floor & finishing even and smooth without using extra cement complte all as specified and directed.
M/L for PCC 50mm thick (1:3:6) type C-2 using (40mm graded stone aggregate)as in plinth protection including hacking out exsting concrete surface complete all as specified and directed.
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com pound, Grade ‘A’ for thickness 200 mm concrete slab
Taking down cement plaster on brick / surfaces built in cement mortar including raking out joints, bading for key scrubbing down with water etc complete.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finishing the surface fair and even all as specified and directed.
Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed (Water proofing compound to be measured and paid for separately).
M&L for preparation of newly plastered surfaces of wall, applying two coats of oil emlusion distemper over a coat wall care putty of 3 mm thick and alkali primer.
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, ,removing material to store for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge
M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100volts, (Make: Havells/ Finolex/ Plaza) drawn through and including non metalic rigid PVC casing and caping not less than 25mm with all accessories fixed on wall//ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of PVCmoduler box with cover plate in any size fixed on wall for fixing the switches, switch sockets,sockets, regulators etc complete all as specified for:- NOTE: a) Colour coding shall be followed as given below:- i) Phase - Red/Blue/Yellow ii) Neutral - Black iii) Earth - Green (b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit. (c) Make of wire : Polycabl/Plaza/Havells/Gloster (d) Make of PVC casing capping/Conduit :- Precision/ pesto plast / National/Plaza
One light point controlled by one 5A switch
One Ceiling Fan point controlled by one 5A switch
One Exhaust Fan point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 2.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including required size of PVC modular box with cover plate for One 5 pin, 15A switch socket combination on the independent board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red/Blue/Yellow (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately.(iv) Make of wire : Polycabl/Plaza/Havells/Gloster (v) Make of PVC casing capping/Conduit :- Precision/ pesto plast / National/Plaza
M&L for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 4.0 sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including PVC modular box with cover plate complete comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red/Blue/Yellow (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately.(c) Make of wire : Polycabl/Plaza/Havells/Gloster (d) Make of PVC casing capping/Conduit :- Precision/ pesto plast / National/Plaza
S & F ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed by EIC. Make : Cona/Anchor
S & F modular switch 1 way 6A all as specified and directed by EIC. Make : Roma/Goldmedal/legrand/Crabtree
S & F modular switch 1 way 16A,1 module all as specified and directed by EIC. Make : Roma/Goldmedal/legrand/Crabtree
S & F modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed by EIC. Make : Roma/Goldmedal/legrand/Crabtree
S & F modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed by EIC. Make : Roma/Goldmedal/legrand/Crabtree
S&F for modular fan step regulator, 120W - 2 modular all as specified and directed by EIC. Make : Roma/Goldmedal/legrand/Crabtree
S&F on replacement of hanger clamp assembly with down rod up to 3 feet for hanging of ceiling fan with nuts,bolts,washers, rubber wheel, hanger clamp & split pin complete all as specified & directed by EIC.
Disconnecting and taking down the fan and Overhauling of ceiling fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust, rust and applying two coat white enamel paint over a coat of steel primer, assembling and refixing at same position complete all as specified.
Disconnecting and taking down the fan and Overhauling of exhust fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust, rust and applying two coat gray paint over a coat of steel primer, assembling and refixing at same position complete all as specified.
S & F Ventilating fan 250 mm sweep size,RPM 1350, plastic body type incuding self cosing louver and making all electric connections complete all as directed. Make: CG//Havells/Bajaj Product code 70049
Supply and fixing in repair new generation walll/surface mounted 20W LED plastic batten fitting with white acrylic cover, 4 feet surface mounted provides high quality ecomonic energy saving lighting complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with three core twisted white copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG /Wipro/Philips/Bajaj cat No BCLSB 20WH/ Havells/Benlo/Shakti
Supply and fixing in repair new generation ultraslim LED panel recessed LED 2X2 Luminaire 36 watt including driver, CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting Suitable for 600 x 600 mm modular/POP/Gypsum ceiling. Make : Havells/Wipro/C&S/Bajaj cat No BZRSQL 36L LED GX D WH SD
Supply and fixing in repair new generation walll/surface mounted 1x 10 W LED batten fitting, 2 feet surface mounted provides high quality ecomonic energy saving lighting complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG /Wipro/Philips/Bajaj cat No BCLSB 10WH/ Havells/Benlo/ Shakti
Supply and fixing in repair new generation walll/surface mounted bluk head LED fitting 10W, provides high quality ecomonic energy saving lighting complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling including connecting up with copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG /Wipro/Philips/Baja Cat No BIBWP 10W LED/ Havells /Benlo/Shakti
S & F in replacement decorative LED post tops with transparent diffuser 25W, IP 65 protection complete with all accessories and all as specified and directed by Engr-in-charge Make : C&S/ Shakti/Benlo/Bajaj cat no-BGCTN 25W LED WW
S & F in replacement decorative LED post tops 40W made in xast aluminium with decorative opal polycarbonate diffuser with IP 65 protection complete with all accessories and all as specified and directed by Engr-in-charge Make : C&S/ Shakti/Benlo/Bajaj cat no-BGCL 40W LED WH
S & F in replacement LED garden light 9W LED bollard in rectangular shaped victorian design with opal acrylic diffuser and IP 65 protection with all accessories includingn PCC foundation tapper plug, bolts, nuts, screws etc complete all as specified and directed by Engr-in-charge. Make : Bajaj cat NO BGBOS 600 9W LED WW/C&S/ Havells
Supply and fix in replacement of LED flood lights 60 W energy saving and enviromental friendly light fitting IP 66 high power LED floodlight with pressure die cast aluminium housing complete with all accessories. C&S / Havells/Bajaj cat No BJFL 60W LED I
S&F in repair of LED Aviation Light Luminaries all as specified and directed. Make : Bajaj Cat No BGAV 302 LED/CG/Philips
Supply and fixing in replacement LED 120W Street/building security light fittings with high pressure die cast housing with toughened glass and individual LED with secondary optics and IP66 protection complete all as specified and directed by EIC. Make : CG /Wipro/Philips/Bajaj cat No BRTFG 120W LED CR/ Havells/Benlo/Shakti
Supply and fix in replacement MS arms bracket 30 degree bend, 1.5mtr long for mounting one in nos street light fitting including clamps / nut / bolts & washer to brace the same properly with duly painted in synthetic enamel paint of two coat in silver colour complete all as specified and directed by the Engr-in-Charge.
S&F in repair of double door type vertical type TPN DB 4 Way ,415V with busbar , double door type IK 09,IP 43 protection suitable for housing MCCB's all as specified and directed by EIC.Make : C&S/Seimens/Schinder/Legrand. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type SPN DB 12 Way ,240V with 100A copper busbar each phase , double door type IK 09, IP 54 protection suitable for housing MCB's all as specified and directed by EIC. Make : C&S/Seimens/Schinder/Legrand Cat No 507642. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S & F in repair MCB DB double door SPN 4 Way with 200 Amps rated copper bus bar, IP 54, IK 09 suitable for flush mounting and surface mounting complete etc all as specified and directed. C&S/Seimens/Schinder/Legrand Cat No 507640
S & F in repair of modular power socket 25A,2 module, 25A plug top, 25A mini MCB 'C' series 3KA including 4 module box with cover plate complete all as specified and directed by EIC. Make: Anchor/Roma/Crabtree SAP code : ACNKCXW253, DCTNCSPA025,ACAGXXW253, ACVPPCWV03,ACTXPIWX03
S & F MCB SP 6-32 Amps,10KA, 'B' curve, all as directed. Make : C&S/Seimens/Schinder/ Legrand cat No 408587 to 408595
S & F MCB SPN 63 Amps,10KA , 'B' curve all as directed. Make : C&S/Seimens/Schinder/Legrnad cat No 408620
S & F MCB SPN 40 Amps,10KA , 'B' curve all as directed. Make : C&S/Seimens/Schinder/Legrnad cat No 408617
S & F MCCB FP 125 Amps,16KA, Thermal magnetic O/C & SL protection, complete all as specified and directed. Make : C&S/Seimens/Schinder/Legrand cat No 420016
M&L for shifting of Split AC unit from existing postion & refixing the new position/location including outdoor stand as required, Servicing, leak testing, testing & commisssioning all as specified and directed BY EIC.
Supply and fixing copper tubings of appropriate dia for suction line & for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing thugh pipe and making good distrubed surface completely.
S&F for Rigid non-metallic PVC conduit 20mm dia incl connecting to AC condenced water drain pipe complete fixing accessories such AS complete of all tees, bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs all as specified and as directed
M&L for sub-main wiring with 2 runs of 4.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Plaza/Gloster
M&L for sub-main wiring with 2 runs of 2.5 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC Conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 2.5 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Plaza/Gloster
M&L for sub-main wiring with 2 runs of 6.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC capping casing not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Plaza/Gloster
Disconnecting & taking down old Unservicable cable & Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3½ core complete all as specified and directed by Engr-in-Charge. Make: Havells/Polycab/Finolex/Gloster
S&F in repair FRP looping box 217x253x115 cable entry from bottom and side, 100% weather proof for outdoor installation suitable for pole mounting, tamper proof, restricts unauthorised tapping, IS 11731, IP 66/67 suitable for 16-35 sqmm 3.5 core aluminium cable including 1 No MCB 6-32 Amp and connector block two way and fixing with flat aluminium clamps not less than 25 mm x 3 mm with suitable size nuts, bolts and washers inside and outside looping box complets as directed.Make : Hensel Cat No: KF 3500H
S&F in repair FRP looping box 168x253x115 with locking arrangement, shockproof and rustproof, rot-proof and termite resistance, cable entry from bottom and side, 100% weather proof for outdoor installation, tamper proof, suitable size nuts, bolts and washers inside and outside looping box complets for fixing on wall as directed.Make : Hensel Cat No: KG 9002
SB CONSTRUCTION
Laxmi Sales
SHRI SAI ENTERPRISES
BA Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .