| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC Bidder Quoted L1 rates | |
| 2 | L2₹27.9 L+₹5,820 (0.21%)Rejected-Finance | L2 | Rejected-Finance Bidder not quoted L1 rates | |
| 3 | L3₹31.9 L+₹4.1 L (14.7%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-Finance Bidder not quoted L1 rates | |
| 4 | L4₹58.2 L+₹30.4 L (109.2%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L4 | Rejected-Finance Bidder not quoted L1 rates |
| Sl No | Description | Qty | Unit | Nexus Infratech L2 | Rama Electricals L3 | Adinath Technical Services L1 | SBS Enterprises L4 |
|---|---|---|---|---|---|---|---|
| 1.00M&L for Plant/Machinery for Dehydration and Filteration of 22/0.415 KV grade Transformer oil for extracting moisture content in the oil and carbon deposits and achiving the dielectric strength to 45 KV for 1 minute with a sphare gap of 2.5 mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into the transformer all as specified and directed by Engr in charge. Note: The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration. | |||||||
| 1.01 | 2000 KVA, Make - Voltamp | 9,440 | PER LITRE | 10 ₹94,400 | 6 ₹56,640 | 10 ₹94,400 | 5 ₹47,200 Lowest |
| 1.02 | 500 KVA, Make - Voltamp | 2,700 | PER LITRE | 10 ₹27,000 | 6 ₹16,200 | 10 ₹27,000 | 5 ₹13,500 Lowest |
| 1.03 | 350 KVA, Make - Pactil | 1,275 | PER LITRE | 10 ₹12,750 | 6 ₹7,650 | 10 ₹12,750 | 5 ₹6,375 Lowest |
| 2.00Preventive Maintenance and Servicing of 22/0.415 KV Power Transformer outdoor type by disconnecting carefully electric connection on primary & secondary side by disconnecting incoming and outgoing HT/LT cables/sandwitch duct connection and remove the transformer tank top cover/lid, draining out the transformer oil and keeping in safe custody in clean and dry containers for reuse. and carrying out the maintenance work by experienced and qualified Engineer, dismantling the OLTC, dismantling HT/LT bushings from core winding and lifting the core assy carefully without damaging by using the tripod/ chainpully/crane etc, cleaning / removing the sludge from the transformer tank, cleaning the OLTC and checking the serviceability of the coil / core winding, checking the condition of the body, cleaning the coil/core assy, refixing of core/core assy, OLTC, HT/LT winding connection, connection of protective devices like buckholz relay connection, winding temperature indicator ,oil temperature indicator including fixing new gaskets to transformer top and all other places gaskets/washer, terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil incl improvement of insulation resistance value within desired level by heating or any other method to required level complete all as directed to the entire satisfaction of Engr in Charge. (Note- Filteration of oil will be measured and paid separately) | |||||||
| 2.01 | 2000 KVA, Make - Voltamp | 4 | EACH JOB | 5,100 ₹20,400 | 7,000 ₹28,000 | 5,000 ₹20,000 Lowest | 10,000 ₹40,000 |
| 2.02 | 500 KVA, Make - Voltamp | 2 | EACH JOB | 4,100 ₹8,200 | 5,000 ₹10,000 | 4,000 ₹8,000 Lowest | 9,000 ₹18,000 |
| 2.03 | 350 KVA, Make - Pactil | 1 | EACH JOB | 3,300 ₹3,300 | 4,000 ₹4,000 | 3,200 ₹3,200 Lowest | 8,000 ₹8,000 |
| 3.00S&F HT bushing suitable for 22/0.415 KV Transformers of following capacity and Make including dismantling old one :- | |||||||
| 3.01 | 2000 KVA, Make - Voltamp | 3 | EACH | 730 ₹2,190 | 1,200 ₹3,600 | 720 ₹2,160 Lowest | 2,500 ₹7,500 |
Tender Value
₹51.1 L
EMD Value
₹1.0 L
Closing Date
8 Apr 2026, 6:00 pmClosed
COMMANDER WORKS ENGINEER PUNE - 01
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85973 REPAIR / MAINTENANCE OF VCB, ACB PROTECTIVE DEVICES, HT UG CABLES, HT DISTRIBUTION SYSTEM, TRANSFORMER AND OTHER MISC HT WORK OF ELECT SUPPLY IN NEW CHSC AND OTHER CONNECTED AREA UNDER AGE E/M-II OF GE (SOUTH) PUNE
2026_MES_755832_1
85973 CWE PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE (SOUTH) PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (CENTRAL)
₹1.0 L
Yes
30 May 2026
10 Mar 2026
15 Apr 2026
10 Mar 2026
8 Apr 2026
1 Apr 2026
M&L for Plant/Machinery for Dehydration and Filteration of 22/0.415 KV grade Transformer oil for extracting moisture content in the oil and carbon deposits and achiving the dielectric strength to 45 KV for 1 minute with a sphare gap of 2.5 mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into the transformer all as specified and directed by Engr in charge. Note: The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration.
2000 KVA, Make - Voltamp
500 KVA, Make - Voltamp
350 KVA, Make - Pactil
Preventive Maintenance and Servicing of 22/0.415 KV Power Transformer outdoor type by disconnecting carefully electric connection on primary & secondary side by disconnecting incoming and outgoing HT/LT cables/sandwitch duct connection and remove the transformer tank top cover/lid, draining out the transformer oil and keeping in safe custody in clean and dry containers for reuse. and carrying out the maintenance work by experienced and qualified Engineer, dismantling the OLTC, dismantling HT/LT bushings from core winding and lifting the core assy carefully without damaging by using the tripod/ chainpully/crane etc, cleaning / removing the sludge from the transformer tank, cleaning the OLTC and checking the serviceability of the coil / core winding, checking the condition of the body, cleaning the coil/core assy, refixing of core/core assy, OLTC, HT/LT winding connection, connection of protective devices like buckholz relay connection, winding temperature indicator ,oil temperature indicator including fixing new gaskets to transformer top and all other places gaskets/washer, terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil incl improvement of insulation resistance value within desired level by heating or any other method to required level complete all as directed to the entire satisfaction of Engr in Charge. (Note- Filteration of oil will be measured and paid separately)
2000 KVA, Make - Voltamp
500 KVA, Make - Voltamp
350 KVA, Make - Pactil
S&F HT bushing suitable for 22/0.415 KV Transformers of following capacity and Make including dismantling old one :-
2000 KVA, Make - Voltamp
500 KVA, Make - Voltamp
350 KVA, Make - Pactil
S&F LT bushing suitable for 22/0.415 KV Transformers of following capacity and Make including dismantling old one :-
2000 KVA, Make - Voltamp
500 KVA, Make - Voltamp
350 KVA, Make - Pactil
S&F copper terminal stud, both end threaded complete with double nuts and washers with heat resistant gasket suitable for LV side of 22/0.415 KV transformer including dismantling existing one complete all as directed for following
2000 KVA, Make - Voltamp
500 KVA, Make - Voltamp
350 KVA, Make - Pactil
S&F copper terminal stud, both end threaded complete with double nuts and washers with heat resistant gasket suitable for HV side of 22/0.415 KV transformer including dismantling existing one complete all as directed for following
2000 KVA, Make - Voltamp
500 KVA, Make - Voltamp
350 KVA, Make - Pactil
S&F Silica gel breather suitable/compatible to 22/0.415 KV transformer including taking down existing one complete all as specified and directed.
Repair to transformer to arrest oil leakage by removing transformer oil , dismantling the top cover alongwith conservator tank/ OLTC, replacing the top gasket washer etc replacement of HT/LT bushes complete dismantling the cooling fins and welding where leakage to arrest oil leakage and reassembling the transformer, refilling filtered oil testing complete for transformer of following capacity :-
2000 KVA, Make - Voltamp
500 KVA, Make - Voltamp
350 KVA, Make - Pactil
S&F in repair Oil Temperature Indicator (OTI), suitable/compatible to 22/0.415 KV Transformers of following capacity/make including modification required of any type and dismantling old one :-
2000 KVA, Make - Voltamp
500 KVA, Make - Voltamp
350 KVA, Make - Pactil
S&F in repair winding Temperature Indicator (WTI), suitable/compatible to 22/0.415 KV Transformers of following capacity/make including modification required of any type and dismantling old one :-
2000 KVA, Make - Voltamp
500 KVA, Make - Voltamp
350 KVA, Make - Pactil
Supply and topping up of transformer oil with di-electric strength not less than 45 KV for 1 minute at 2.5mm gap in to the conservator tank / body tank of the transformer at various Sub Stations including maintaining and sumitting the test results to Engr-in-charge. Note : (i) New Transformer oil will be filled in the transformer only after filteration and de-hydration of existing transformer oil of the transformer. (ii) Transformer oil shall be supplied in sealed container /barrel with test result and test certificate etc.
Preventive Maintenance and Servicing of Automatic Voltage Regulator and OLTC for healthy functioning of voltage tap required for LT switchgears installed for each transformer of 2000 KVA by taking shutdown of each transformer. Checking for operating mechanism, inspection of control wiring, tap changer meter, relay wiring for AVR, greasing of all moving parts of OLTC mechanism, checking and realignment of mechanism for its proper functioning and operation, re-assembling of OLTC and AVR, fixed in its original position, testing for functions, and commissioning complete all as directed by Engr in charge.
Preventive Maintenance and Servicing of Automatic Voltage Regulator and OLTC for healthy functioning of voltage tap required for LT switchgears installed for each transformer of 500 KVA by taking shutdown of each transformer. Checking for operating mechanism, inspection of control wiring, tap changer meter, relay wiring for AVR, greasing of all moving parts of OLTC mechanism, checking and realignment of mechanism for its proper functioning and operation, re-assembling of OLTC and AVR, fixed in its original position, testing for functions, and commissioning complete all as directed by Engr in charge.
Preventive Maintenance and Servicing of Automatic Voltage Regulator and OLTC for healthy functioning of voltage tap required for LT switchgears installed for each transformer of 350 KVA by taking shutdown of each transformer. Checking for operating mechanism, inspection of control wiring, tap changer meter, relay wiring for AVR, greasing of all moving parts of OLTC mechanism, checking and realignment of mechanism for its proper functioning and operation, re-assembling of OLTC and AVR, fixed in its original position, testing for functions, and commissioning complete all as directed by Engr in charge.
S&F in replacement Main Moving Contact as per existing size and specifications required for repair of 22/0.415 KV transformer's OLTC including testing and commissioning of the transformer complete all as specified and directed.
S&F in replacement Resistance Moving Contact as per existing size and specifications required for repair of 22/0.415 KV transformer's OLTC including testing and commissioning of the transformer complete all as specified and directed.
S&F in replacement Fixed Contact as per existing size and specifications required for repair of 22/0.415 KV transformer's OLTC including testing and commissioning of the transformer complete all as specified and directed.
S&F in replacement Oil Seal as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.
S&F in replacement Top Cover Gasket as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.
S&F in replacement Main Flange Gasket as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.
S&F in replacement Bushing Board Gasket as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.
S&F in replacement Bushing Board as per existing size and specifications required for repair of 22/0.415 KV transformer including testing and commissioning of the transformer complete all as specified and directed.
S&F in replacement Automatic Voltage Regulating Relay as per existing size and specifications required for repair of RTCC of 22/0.415 KV transformer including testing and commissioning complete all as specified and directed.
S&F in replacement Tap Position Indicator as per existing size and specifications required for repair of RTCC of 22/0.415 KV transformer including testing and commissioning complete all as specified and directed.
Taking out HT VCB, 22 KV grade 1250 Amps rating from HT panel for servicing / repairs by dismantling the HT VCB operating mechamism, inspection of control wiring realignment of moving contacts with fixed contacts assy, vaccum interrupter ,checking of relays for protection. greasing of all moving parts of mechanism, checking and realignment of mechanism for its proper functioning and operation, re-assembling of HT VCB , fixed in its original position, testing for functions, and commissioning complete all as directed by Engr in charge.
M&L for Calibration of 22 KV grade HT VCB relays of various types by OEM or OEM authorised dealer through primary & Secondary injection method by bringing relay test kit and other required measuring equipments to the site, after testing refixing to VCB 22 KV panel all as directed. Note- Certificate of this test will be provided by the contractor free of cost.
Supply and fix in repair HT bushing spout of fibre or as per existing for 22 KV HT VCB 1250 Amp rating and removing the unsv spout complete all as directed by Engr in charge.
S&F Spring charging Handle suitable for 22 KV HT VCB panel complete all as directed by Engr in charge.
S&F in repair spring charging motor suitable for 22 KV HT VCB panel complete all as directed by Engr in charge.
Testing of HT current transformer (set of three) through primary current injection method and also checking the connected panel wiring by bringing required test kit and other required testing equipment and also checking tripping and closing operation complete all as directed.
Supply, install, test, commissioning of 22 KV grade HT VCB current transformer with CT ratio 200/15 or 100/5 fixed with HT VCB 22 KV including necessary cable connection etc suitable for fixing in HT panel board of Make: Schneider including modification required at site to be carried to fix CT upto recess/coils including removing the burnt CTs complete all as directed.
M & L for checking of Potential Transformer by conducting ratio test/meggering for IR values, provided in VCBs 22 KV feeders checking of control wiring meters, relay and tripping system.complete all as directed.
S & F in repair PT for HT VCB 22 KV/415 volts, 100 VA burden, resincast epoxy moulded with metal enclosure as per site requirement and connecting bus bar including providing fuse links complete all as directed.
S&F in replacement Indicating lamp (Red/Yellow/Blue/white) LED type including taking down existing one complete all as specified and directed.
S & F in replacement emergency stop button push and turn type all as specified and directed.
S & F in replacement breaker control switch Trip-Neutral-Close type as per site requirement including taking down existing one all as specified and directed.
S & F in replacement local remote switch suitable for HT 22 KV VCB Panel all as specified and directed.
S&F in replacement digital voltmeter 3-phase suitable for fixing with existing HT VCB 22 KV panel complete all as directed.
S&F in replacement digital Ammeter 3-phase suitable for fixing with existing HT VCB 22 KV panel complete all as directed.
S&F in replacement of Digital Multifunction Meter LED, Accuracy Class 1, with RS 485 Parameters V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours etc. without disturbing other accessories and taking down old unsv meters etc complete all as specified and directed at site.
S&F in replacement numerical type relay, 3 O/C+1 E/F with RS 485 Port suitable for fixing in existing HT VCB 22 KV panel complete all as directed.
S&F in replacement Master trip relay, coil voltage 24 V DC suitable for fixing in existing HT VCB 22 KV panel complete all as directed.
S&F in replacement Plug in type relay for Breaker contact multiplication, Aux contacts 2NO+2NC, coil voltage 24 V DC suitable for fixing in existing HT VCB 22 KV panel complete all as directed.
S&F in replacement Test terminal block suitable for fixing in existing HT VCB 22 KV panel complete all as directed.
S&F in replacement 8 window annunciator with hooter suitable for fixing in existing HT VCB 22 KV panel complete all as directed.
S & F control wiring of 1.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters etc. including suitable size of copper lugs, PVC CABLE ducts, suitable size of galvanised or cadmium plated high tensile nuts, bolts and washers etc for 22 KV VCB Panel all as specified and directed.
S & F control wiring of 2.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc for 22 KV VCB Panel all as specified and directed.
S & F control wiring of 4 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc for 22 KV VCB Panel all as specified and directed.
S & F control wiring of 6 Sqmm Four core stranded FRLS PVC insulated copper conductor cables of including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc for transformer, RTCC and OLTC all as specified and directed.
Supply only hand gloves HT for operating / handling sub station 22 KV ISI Marked.complete all as directed.
M&L for Servicing /Caliberation / Repairs to Air Circuit Breaker 800 to 3200 Amps by OEM of ACB only for EDO (Electrically Draw Out) type/ MDO tpe(Mannually Draw out type). Taking out ACB for servicing / repair and checking / caliberation of microprocessor release,Earth fault protection of 4 pole, 50 KA breaking capacity 415 volts with all draw out type mechanism, advanced self powered electronic protection units, neutral overload protection, automatic earth fault relay / over current relay , automatic safety shutter, inbuilt temperature protection, icu=ics=icw(1s)=50 KA fixed in panel complete including relay wiring checking ,LT UG cable connection with main incoming ACB complete connection for its healthy functioning all as directed by Engr in charge. Note- Certificate of Servicing /Caliberation will be provided by the contractor free of cost.
S&F in repair shunt realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.
S&F in repair under voltage realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.
S&F in repair earth fault realease for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.
S&F in repair lockable trip push button for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.
S&F in repair Racking padlock assemby for air circuit breakers microprocessor based type suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed.
S & F in replacement of cylindrical panel locks of suitable size or as per sample including drilling, cutting and welding etc in panel sheets without disturbing to other existing fitments including taking down old one complete all as specified and directed.
S&F in repair APFC controller 8 step for automatic correction of power factor suiable for 415 volt, 3 phase power supply complete with necessary fixing complete all as specified and directed. Make : Lauritz Knudson Cat Part No. etaSMART 8R or equivalent in ABB / Siemens
S&F in repair APFC controller 14 step for automatic correction of power factor suiable for 415 volt, 3 phase power supply complete with necessary fixing complete all as specified and directed. Make : Lauritz Knudson Cat Part No. etaSMART 14R or equivalent in ABB / Siemens
S&F in repair ultra heavy duty capacitor bank cylindrical series 5KVAR for automatic correction of power factor suitable for 415 volt 3 Phase power supply complete with necessary connection and replacing the Old unserviceable capacitor bank of any type and description complete all as specified and directed. (Make : Lauritz Knudsen cat Part No. LTCCU or equivalent in ABB / Epcos
S&F in repair ultra heavy duty capacitor bank 10KVAR for automatic correction of power factor suitable for 415 volt 3 Phase power supply complete with necessary connection and replacing the Old unserviceable capacitor bank of any type and description complete all as specified and directed. (Make : Lauritz Knudsen cat Part No. LTBCU or equivalent in ABB / Epcos)
S&F in repair ultra heavy duty capacitor bank cylindrical series 25KVAR for automatic correction of power factor suitable for 415 volt 3 Phase power supply complete with necessary connection and replacing the Old unserviceable capacitor bank of any type and description complete all as specified and directed. (Make : Lauritz Knudsen cat Part No. LTCCU or equivalent in ABB / Epcos)
S&F in repair ultra heavy duty capacitor bank 50KVAR for automatic correction of power factor suitable for 415 volt 3 Phase power supply complete with necessary connection and replacing the Old unserviceable capacitor bank of any type and description complete all as specified and directed. (Make : Lauritz Knudsen cat Part No. LTBCU or equivalent in ABB / Epcos)
S&F repair Capacitor duty contactors suitable for 5 KVAR capacitor bank complete all as specified and directed. Make : Lauritz Knudsen / Siemens /Schneider
S&F repair Capacitor duty contactors suitable for 10 KVAR capacitor bank complete all as specified and directed. Make : Lauritz Knudsen / Siemens /Schneider
S&F repair Capacitor duty contactors suitable for 25 KVAR capacitor bank complete all as specified and directed. Make : Lauritz Knudsen / Siemens /Schneider
S&F repair Capacitor duty contactors suitable for 50 KVAR capacitor bank complete all as specified and directed. Make : Lauritz Knudsen / Siemens /Schneider
Supply, fix, test and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich busduct, in repair of IP54, IEC 61439-6, copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for indoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM complete all as specified and as directed.
Supply, fix, test and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich busduct, in repair of IP54, IEC 61439-6, copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for outdoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM complete all as specified and as directed.
Supply, fix, test and commissioning of aluminium enclosure of 2500 Amps ratings, TPN, aluminium sandwich busduct, in repair of IP54, IEC 61439-6, copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for indoor installation including connection with terminal with all accessores as required complete, copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, busbar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM complete all as specified and as directed.
Supply, Fix, Test and Commissioning of copper flexible suitbale for existing busbar trunking system for connection of BBT to Panel / transformer complete all as specified and directed.
Supply, Installation, Testing & Commissioning of Expansion Joint as per existing for BBT complete all as specified and directed.
Preventive maintenance/testing of 2500 Amps rating TPN aluminium sandwich busduct through OEM (L&T) or OEM authorised dealer only for detection of weak insulation and continuity etc. as per the procedure laid down by OEM complete all as specified and directed by Engr-in charge Note: (a) Testing will be carried out for the whole length of bus duct from Sub station No 1 to AC Plant (b) Dismantling and reassembling of Cable tray required at site is deemed to be included in the quoted rate.
Preventive maintenance/testing of 3200 Amps rating TPN aluminium sandwich busduct through OEM (L&T) or OEM authorised dealer only for detection of weak insulation and continuity etc. as per the procedure laid down by OEM complete all as specified and directed by Engr-in charge Note: (a) Testing will be carried out for the whole length of bus duct from Sub station No 1 to LT Panel (b) Dismantling and reassembling of Cable tray required at site is deemed to be included in the quoted rate.
M&L for bringing Cable testing van (Fault Finder) for detecting the location of fault in the HT UG cable of any size complete all as specified and as directed.
Supply,laying, testing and commissionnig of HT cables 22 KV grade (Earthed), XLPE insulated and PVC bedded galvanized steel strip armoured electric power cable (heavy duty) with aluminum conductor, conforming to IS - 7098 part-II, including removing unsv cable complete of sizes 185 Sqmm 3 core.
S & Laying in replacement of Synthetic Rubber Insulated Matt 2.5mm Thick and of size 2m X 1m suitable for Voltage upto 11KV working pressuter confirms to IS 15652-2006 and applying adhesive to fix before laying the new one complete all as specified and directed.
Supply and fix in repair indoor type HT 22 KV end termination Kit cold shrinkable type suitable for XLPE cable of size 3 core 185 Sqmm by removing burnt / unsv joints from VCB complete all as directed by Engr in charge.
Supply and fix in repair outdoor type HT 22 KV end termination Kit cold shrinkable type suitable for XLPE cable of size 3 core 185 Sqmm by removing burnt / unsv joints from transformer complete all as directed by Engr in charge.
Supply and fix in repair HT 22 KV straight through jointing Kit cold shrinkable type suitable for XLPE cable of size 3 core 185 Sqmm by removing burnt / unsv complete all as directed by Engr in charge.
Material and labour for cutting of existing road/ hard standing by providing suitable T&P to make suitable size bore for fixing 50 mm dia pipe in road crossing etc. including the cost of making good the disturbed surface and matching with existing (Chequered tiles/Road/PCC) complete all as specified and directed
Supply and laying 100 mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etc for fixing on walls, poles etc. complete all as specified and directed.
Excavation in trenches in hard/dense soil not exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and directed
Excavation in trenches in soft/disintegrated rock not exc 1.5m wide and not exc 1.5m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated material [soil] to a distance not Exc 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and as directed.
Supply and Laying 90mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6mm galvanized iron strip, complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6mm Copper strip, complete all as specified and directed.
M&L for testing of earthing of transformer / VCB Panel etc. with the help of digital earth tester duly disconnecting the terminals as per site requirement and submitting the test results complete all as specified and directed.
Supplying and laying synthetic rubber insulated mats 3 mm thick for voltage upto 33 KV (size 2 m x 1 mtr) for electrical purpose as per IS 15652-2006 suitable for electrical shock safety complete all as directed by Engr in charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.56 MB
85973TenderDocs.pdf
Tender Documents • 4.99 MB
BOQ_846605.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .