Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹9.9 L+₹1.5 L (18.4%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹10.1 L+₹1.7 L (20.3%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹10.5 L+₹2.1 L (25.0%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L4 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
3 Oct 2020, 6:00 pmClosed
Lt Col Sidhartha Singhal
GE (P) Dappar
Repair/Replacement of Distributions boards/ meter boxes / submain wiring and connected items at adm area at Mil Stn Dappar under GE (P) Dappar
2020_MES_375057_1
GE (P) DPR-15/2020-21
Open Tender
Miscellaneous Goods
Works
180 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) Dappar
₹25,000
Yes
21 Dec 2020
5 Sept 2020
5 Oct 2020
5 Sept 2020
3 Oct 2020
18 Sept 2020
5 Sept 2020 - 18 Sept 2020
Amount
Taking out existing sub main wiring of any description and size including earth wire incld wooden battens/ conduits/quities from stone/brick masonry walls, roofs, floors, etc. all as directed by Engr-In- Charge.
M&L Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable size of cable 2x4 sqmm (line conductor) & 1x2.5 sq mm (earth conductor). 1100 V grade drawing in & includingheavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core copper conductor cable, green in colour as in earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note : (i) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
S&F Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V,8 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. Make : Legrand/ABB/Schenider
Re-fiixing Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V,8 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
Removing existing unserviceable Multi-meter box along with its enclosure, old wiring in between DB's/main switch/meter and S & F anti corrosive, dust proof, vermin and water proof, factory fabricated sheet metal wall flush mounted type Multi-meter box of size not less than 1.0m x 1.0m x 0.25m with 2mm thick CRCA sheet and including applying of two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer of colour as approved by Engr-in-Charge suitable to accommodate and comprising of following :- (a). Removing and re-fixing electric energy meter - 4 Nos. (b). Wiring with PVC insulated unsheathed ISI marked 2 runs of 6 sqmm and single run of 4.0 sqmm, as earth continuity, single core multi stranded copper conductor cable fixed to meter box with PVC tag connected in between incoming DB and electric meters etc complete all as specified and directed. (c). Space for accomodation of MCCB TPN DB 6 way - 01 No. NOTE - (a). The metering box must have 1 No. Dia. 32 mm incoming Cable entry hole with Gland provided at base and 4 Nos. Dia. 16 mm Outgoing cable entry holes with Gland. (b). The Multi-Meter Box should have 04 Nos. viewing windows made out of toughened glass of 5 mm thickness strategically placed so as to view the energy meter readings without opeing the door of the meter box and shall be fixed from inside of the cover of Multi-meter box with stainless steel frame (glass holder)with suitable rubber gasket from inside the cover, so that it can withstand weather effect. (c). The system shall be A.C or three phase, four wires, 433 V, 50 Hz with effectively grounded neutral. (d). The box must include of accessories like hinges, clamp, handles etc. (e). Multi-Meter box shall be so constructed so as to have roof tapering down for easy flow of rain water.(F). Cost of cutting chases in wall for flush fitting of Meter box and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. (g). It should have locking arrangement by way of sealing and cann't be opened without breaking seal. Locking arrangement shall be such that a Lock with Key for locking of Multi-Meter Box to be provided. (h). The door in closed position should be overlapped on base such that direct entry of screwdriver, tool or film is not possible. (i). The contractor has to furnish a detailed dimensional drawing showing clearly the dimensions and material of Multi-Meter Box and its constructional features for approval of Engr-in-Charge prior to manufacturing the same. (j). Sign of danger shall be clearly and indelibly embossed (not printed) on the cover of the Multi-meter box.
S&F LED building security light, pressure die cast aluminum housing, 15 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 6 mtr from ground with MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge of make Crompton Greaves cat part no - LSTS-15-CDL OR Equivalent in Philips/Wipro. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
Supply and fixing in replacement MCB SP 6 -32 Amps,10 KA, 'C' series 240 V ISI marked complete all as specified and directed by Engineer-in-charge. MAKE : Legrand/ABB/Schenider
Supply and fixing in replacement MCB SPN 06-32 Amps,10 KA 'C' series 240 V ISI marked.complete all as specified and directed by Engineer-in-charge. Make: Legrand/ABB/Schenider
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.
M& L Point wiring complete with 1.5 sqmm (nominal area) PVC insulated unsheathed multistranded copper condutor single core cable 1100 volts grade FRLSH ISI marked drawn through and including heavy duty non metalic PVC conduit, ISI marked of not less than 20 mm dia, thickness 1.8 mm, concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes, etc. suitable for mounting modular switches, sockets etc and including FRLSH PVC insulated unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following (a) One light / fan / Bell point controlled by one switch
All as per item no :11 but One light point controlled by two way switch all as specified and directed by Engineer-in-charge.
All as per item no :11 but One 5 pin socket outlet independent 5 Amps all as specified and directed by Engineer-in-charge.
Supply and fixing in replacenment ceiling rose bakelite, 63.5mm 3 terminals with base plate ISI marked, complete all as specified and directed by Engr-in-Charge.
S&F Modular socket 6 Amps 2/3 pin combined 3module 240 Volts complete all as specified and directed by the Engr-in-charge .
Supply and fixing in replacenment Modular Angle holder Cat Pat NO 33958 of Anchor Equivalent/Havells/SSK with insulated body with back plate for LED lamps all as specified and directed by the Engr-in-charge .
Supply and fixing in replacement Bulk Head LED 10W, 230 V, 2ft all as per Crompton Make Cat No. - LBHE-10-CDL or equivalent in Philips/Wipro complete all as specified and directed by Engr-in-Charge.
S&F Modular Metal Box 3 module and complete all as specified and directed by the Engr-in-charge .
Fixing only in replacement LED tube light fittings 1 x 20 W, 230V, complete with all accessories internally prewired and including connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as directed by Engr-In- Charge. NOTE : Stores will be issued under Sch ''B". Rate quoted by the contractor is deemed to be inclusive of cost of collection of stores from MES Yard to the site. Rate quoted shall also be inclusive of any minor items like 2 Mtr long PVC insulated copper conductor 1.5 Sqmm wire, suitable size screws etc.
Fixing in replacement mirror light fitting LED 10W, 230 V, 2ft all as per complete all as specified and directed by Engr-in-Charge. NOTE : Stores will be issued under Sch ''B". Rate quoted by the contractor is deemed to be inclusive of cost of collection of stores from MES Yard to the site. Rate quoted shall also be inclusive of any minor items like 2 Mtr long PVC insulated copper conductor 1.5 Sqmm wire, suitable size screws etc.
M& L Earthing complete by using GI wire as earthing lead and MS galvanized earth plate of size 60 cm x 60 cm x 6.3 mm as earth electrode surrounded by charcoal and salt, buried directly in ground vertically in pit of depth not less than 2.25 meter below the ground with top edge of the earth plate at a depth of less than 1.5 mtr below ground level surounded from all sides with mixture of charcoal dust and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron connected iron connected to main switch board or main control board all as shown in electrical plate No 3 of SSR 1991. Pt I and including necessary exc. and earth work. The rate also include testing, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC chambers in cement concrete (1:3:6) type CI 40 mm thick RCC(1:2:4) type B-1 cover and CI frame etc.complete all as specified and directed by Engr-in-Charge.
Taking down existing unsv cable and Material & Laying XLPE insulated UG, armoured heavy duty electric cable in repair with aluminium conductor, 1100 volts , 3.5core 35 Sq mm .Make-Havells/Polycab/Nicco
Taking down existing unsv cable and Material & Laying XLPE insulated UG, armoured heavy duty electric cable in repair with aluminium conductor, 1100 volts , 3.5core 50 Sq mm .Make-Havells/Polycab/Nicco
Excavation in trenches in soft/loose soil n exc 1.5m wide andn. Exc1.5m deep and getting out includingforming bottom surfaces to required level or slope for taking out embeded cables,brick/pcc protective tiles and relaying new/old cable complete all specified and all as directed by engineer incharge.
M&L sand cushioningng (drysand) to under ground cable for cable protection provided with layers 8cm deep before laying and 15 cm after laying the cable complete all as specified and directed.Note :- Punned thickness will be measured only.
M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm.
Removal of surplus excavated soil to a distance exc 50 m but not exc in 100 m and deposited where directed at a level n'exc 50 m above the starting point complete all as specified and directed.
Returning filling in soft/ loose soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer complete all as specified and as specified.
HARISH SALES CORPORATION
M/S Sonu Traders
SUN MANN ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .