| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.8 LAccepted-AOC | ₹50.8 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹54.6 L+₹3.8 L (7.58%)Rejected-Finance XEN ADAMPUR W S DIVISION HISAR | HISAR | HARYANA | 125001 | ₹54.6 L+₹3.8 L (7.58%) | L2 | Rejected-Finance Higher rate to the Contractor |
Tender Value
₹51.5 L
EMD Value
₹1.0 L
Closing Date
17 Jan 2022, 5:00 pmClosed
Executive Engineer (M)
CCS HAU, Hisar
Repair/renovation in Biogas Lab. situated at second floor in the premises of College of Basic Sciences and Humanities for the department of Microbiology at CCSHAU, Hisar. (including public health and electrical works) (re-invited)
2022_HRY_202578_1
3257-C (re-invited)
Open Tender
Civil Works
Works
150 days
CCS HAU
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
₹1.0 L
Yes
15 Apr 2022
4 Jan 2022
18 Jan 2022
4 Jan 2022
17 Jan 2022
4 Jan 2022
Amount
Civil work 1 to 70:- Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (HSR 4.14.1)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. (HSR 4.32)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In cement mortar (HSR 5.7.4)
Demolishing cement concrete manually/ by mechanical means direction of Engineer - in - charge. Nominal concrete 1 :2:4 or leaner mix (i/c equivalent cum design mix) (HSR 5.23.2)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area 3 sq. metres and below each (HSR 5.29.1)
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead Of area 3 sq. metres and below (HSR 5.30.1)
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 sqm mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. (HSR 5.42)
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm (HSR 5.43.2)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (HSR 5.70)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size) (HSR 6.1.6)
20 mm thick cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded Vertical (HSR 6.12.1)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (HSR 6.30.1)
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (HSR 6.30.5)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in (HSR 7.20.1) Cement mortar 1:4 (1 cement: 4 coarse sand)
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : (HSR 7.22.2) Cement mortar 1:6 (1 cement: 6 coarse sand)
Half brick masonry with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level. (HSR 7 .28.2) Cement mortar 1 :4 ( 1 cement :4 coarse sand)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platfonns, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm (HSR 8.26.2.2)
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10 (HSR 9.11.1)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (HSR 9.46.1)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3): 1996 (Boards with BIS certification marks) (HSR 9.46.2)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diaMeter (HSR 9.57.2)
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (HSR 10.60)
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.62)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)
Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (HSR 10.70.2)
Providing and fixing ceramic & Glazed tiles/ vitrified tiles/ of any size of approved make in floors / dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands as per IS specification 15477-2004 using 5 Kg. adhesive per sqm area of tiles and jointed with white cement slurry mixed with pigment to match the shade of tiles excluding cost of tiles. (HSR 10.73)
Providing and laying 60mm thick factory made cement concrete inter1ocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over (BIS 15658:2006) and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (HSR 10.76)
Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)
12 mm cement plaster of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.5.4)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.6.1)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.6.2)
18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1 :5 (1 cement : 5 coarse sand) top layer 6 mm thick with cement mortar 1 :4 (1 cement : 4 fine sand). (HSR 11.19)
Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand): Raised and cut pointing (HSR 11.25.2)
Pointing on tile brick work with cement mortar 1 :3 (1 cement : 3 fine sand): Flush/ Ruled/ Struck or weathered pointing (HSR 11.26.1 )
Cement rendering on plaster 1 mm thick (HSR 11.52)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)
Distempering with 1st quality acrylic distemper (ready mixed) having voe content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work (HSR 11.65.1)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately} Kiln seasoned and chemically treated Hollock wood 35 mm thick shutters (HSR 12.7.2.1)
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm). (HSR 12.9.7.1)
Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Marine plywood conforming to IS: 710 (HSR 12.11.1)
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated Hollock wood (HSR 12.19.1.2.2)
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws 30 mm thick shutters with ISi marked M.S. pressed butt hinges bright Kiln seasoned and chemically treated Hollock wood (HSR 12.19.2.1.2)
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws (HSR 12.36.1)
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 25 mm thick (for cupboard) including ISi marked nickel plated bright finished M.S. Piano hinges IS 3818 marked with necessary screws (HSR 12.36.3)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (HSR 12.157.2.1)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side (HSR 12.158.1)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (HSR 12.159.2 )
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness (HSR 12.160.1)
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge Powder coated minimum thickness 50 micron aluminium (HSR 12.167.2)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate andshock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.1.1)
Profile C Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.2.1)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (HSR 13.29.1)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1 .25 mm M.S. laths with 1.25 mm thick top cover (HSR 13.37.1)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work (HSR 30.28.1)
Replacing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete (HSR 30.64)
Champhering of Granite stone fixed on worktop to requird shape, complete in all respect as directed by Engineer-in-charge. (NS)
Providing and fixing IRC fabric of any size made of 3.15 mm diameter wire, in steel frame with 3 mm thick MS flat iron cover moulding of 12.5 mm width fixed with machine screws, welded, complete in all respects as per architectural drawing & design., complete. (excluding cost of steel frame and MS flat). (NS)
Providing and fixing 45 mm wide solid and 30 mm wide jali Zebra type (PCL rainbow or any other equivalent make as approved by Engineer In charge) horizontal venetian blinds of required size and shape, fixed in position including rawl plugs and screws etc. complete in all respect. (NS)
Providing and fixing 12 mm thick toughened glass ( Saint Gobin make) for door shutter including making holes for fixing accessories such as handles, L-connectors and cut out for floor machine etc., complete in all respect as directed by the Engineer In Charge. (excluding cost of handles, connectors and floor machine). (NS)
Providing and fixing Glass Accessories i.e. handle of size 600 mm x 30 mm of DORMA make (Model XL-C-3004 ) including cost of stainless steel screws etc. complete in all respect as directed by Engineer-In-charge. (NS)
Providing and fixing Glass Accessories i.e. glass door package with lock (floor machine) of DORMA make (Model XL-C-4001) including cost of stainless steel screws etc. complete in all respect as directed by Engineer-In-charge. (NS)
Tacking (making rough) the exposed reinforced cement concrete surface for cement plaster (horizontal and vertical surface) including removing of loose concrete, disposing of the malba and cleaning the surface etc., complete in all respect as directed by Engineer-in-Charge. (NS)
PVC wall paneling consisting of 7mm thick cactus make hollow PVC section, PVC U section beading of size 25mmx8mmx12mm and PVC angle nosing of size 25mmx25mmx1.5mm including cost of PVC gutties, screws, jointed with polyfix (instant glue), complete in all respect as per drawing or as directed by Engineer-in-Charge. (NS)
Public Health work 71 to 106:- Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc. not exceeding 80 mm dia. (HSR 4.16.1.1)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (HSR 4.16.1.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies. (HSR 6.30.3)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado/worktop/risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. (HSR 10.51)
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.62)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)
12 mm cement plaster of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.5.4)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (HSR 13.27)
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 32 mm internal diameter (HSR 20.23.4)
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required 22.86 cm thick wall (HSR 20.26.2)
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside buildings, including cartage from divisional stores or nearest railway station to site of works 32 mm internal diametre (HSR 20.31.4)
Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. (HSR 20.36)
Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benchingb 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. Size 600 mm X 900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) (HSR 21.84.3)
Extra for every 0.30 metre depth of Inspection chamber 600 mm x 900 mm inside (HSR 21.85.3)
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia (HSR 22.14.1.2)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15)
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (HSR 22.26.1)
Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (HSR 22.34)
Providing and fixing 8 mm dia C.P.S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)
Providing and fixing toilet paper holder C.P. brass (HSR 22.42.1)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes (HSR 22.86.2)
25 mm nominal outer dia Pipes (HSR 22.86.3)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal outer dia Pipes (HSR 22.87.4)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (HSR 22.103.3)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore (HSR 22.104.1)
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (HSR 22.108.1)
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR 22.109)
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design 150 mm diameter S.W. pipe (HSR 22.164.2)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181)
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. C.P Brass Two Way (HSR 22.212.1.2)
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B 110 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.2)
90 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.3)
Providing and fixing in position chinaware wash Hand Basin (Avior-R Model) of Hindware Make Cat no.91207, Star white size 59.50 x 42 x 15.5 cm (NS)
Providing and fixing in position C.P brass piller cock Jaquar Make- Model KUP-35021 PM with 190mm extension body. (NS)
Supply and fixing of PVC floor traps (Heavy duty) of 90 mm o/dia outlet of Prince /Supreme/Skipper make, complete in all respect. (NS)
Supply and fixing of PVC gully traps (Heavy duty) of 100 mm dia size ( 4") with cover and frame of Prince/Supreme/skipper make complete in all respect. (NS)
Supply of CPVC Union Couplings with brass internals of Prince/Supreme/Skipper make . (NS) (a) 32 mm dia
Supply of CPVC Control valves with brass internals of Prince/Supreme/Skipper make . (NS) (a) 32 mm dia
Providing and fixing UPVC elbows of Prince/Supreme/Skipper make. (NS) (a) 110 mm (4" i/dia)
Providing and fixing looking mirror 5.0 mm thikc of size 2'-0" x 3'-0" x 2'-6" mounted on asbestos sheet ground fixed in position by means of 4 Nos. C.P. brass screws and washers on rubber washers and rawl plugs embeded in wall or CP brass clamps with CP brass screws etc. complete in all respect. Make:- Saint Gobin/MODI/ATUL (NS)
Electrical work 117 to 168:- Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.1.2)
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B (HSR 23.4.3.2)
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B (HSR 23.4.4.2)
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B (HSR 23.4.5.2)
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1)
1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.5.6.3)
Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2)
Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm each 106long M.S. Road made into suitable suspension hook and erected in R.C.C.slab for the erection of fan complete with all labour and material required tocomplete the job. (HSR 23.8.4)
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules (HSR 23.8.10.1)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7)
Blanking plate (HSR 23.8.11.10)
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9)
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) (HSR 23.22.4.5)
TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) (HSR 23.22.4.7)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1)
40 amp to 63 amp. MCB's FOUR POLE (HSR 23.22.5.8)
Supply and erection of blanking sheet in existing distribution board. (HSR 23.22.7)
Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia (HSR 23.23.2.1)
EARTHING AND LIGHTENING ARRESTOR Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. (HSR 24.1.1)
Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2)
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. (HSR 24.1.13)
Laying of underground cable 0. 75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 50 Sq mm to 150 sqmm 2 to 4 Core (HSR 24.2.2.3)
Laying of underground cable in pipe /existing open/closed trench etc as 50 Sq mm to 150s qmm 2 to 4 Core (HSR 24.2.4.3)
Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50s qmm Cable 2 to 4 Core (HSR 24.2.7.3)
70s qmm to 95s qmm Cable 3 to 3½ Core (HSR 24.2.7.4)
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work . 25sqmm (HSR 24.2.8.5)
50sqmm (HSR 24.2.8.7)
70sqmm (HSR 24.2.8.8)
Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. (HSR 24.4.3)
S/E of underground cable XLPE LT CABLE aluminium conductor armoured .(NS) 25 sqmm 4 core cable (armoured)
50 sqmm 4 core cable (armoured)
70 sqmm 3.5 core cable (armoured)
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe (NS) (i) Size 1.5 sqmm(3/0.81mm)
(ii) Size 2.5 sqmm(3/1.05mm)
(iii) Size 4 sqmm(7/0.85mm)
Supply, installation testing and commissioning of wall/free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware 3mm thick Bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar Bakelite sheet 3mm thick for separately cable alley to BBC from switch chamber extended solid copper bars upto cable alleys shall provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection (Only outer area on all sides shall be measured) (NS)
Supplying and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect. (NS)
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator . {NS} i) 1200mm sweep. Make: Usha, Orient, Crompton.
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator {NS} i) 1400mm sweep. Make: Usha, Orient, Crompton.
S/E of surface/wall mounted ≤20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 2000 or above in cool day light (5700K to 6500K), Power factor >0.95, CRI >80, Average life >50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial) Make: Philips, Havells, Wipro, Bajaj. (NS)
S/E of LED Street Light of system voltage < 70/72watt IP66 Multiple LED with Lens optics and pressure die-cast aluminium housing for effective thermal management. Total system lumen < 72watt LED should be 7700 or above in cool day light 5700K Lumen efficency > 110lm/w. Power Factor >.95 with connections street light / PCC Poles with Bracket i/c 3 year defect liability period and free replacement in case of non functioning of the light fixture. (NS) Make Philiphs , Havell's , Wipro,Bajaj ,
Supply of propeller type AC ventilating fan (exhaust fan) with necessary earthing arrangements of fan with shutter complete in all respects Size 300mm(12”) sweep Make: Orient, Usha, orient, Havells. (NS)
S/E of recessed type 42 Watt full window glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 4600 or above in cool day light (5600K to 6500K), Power factor >0.95, CRI (Ra) >80, LED Lamp efficiency ≥ 140 lm/w, Average life > 50000 hours, complete with all accessories as required with connections (Industrial) Make: Havells (NS)
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Schneider/Crabtree/Athena
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-32 suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:-(i) Cooling coil row -3 Nos.(ii) Air flow (CMH) -800 to 1450 cum/ hr.(iii) Sound level (H/M/L)- 41/38/34/25(silent mode)(iv) Louvers swing- 3D + 3D Auto etc. complete in all respect. (NS) MAKE :- O General/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge ofV-Guard make ISI marked complete in all respect. (N.S.)
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit.
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)
Supply, erection of 0.51 mm jelly filled armored telephone cable laid one mtr. below ground level including the cost of digging, bricks, rawl & laying charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (NS) (i) 20 Pair Make:- DELTON/ FINOLEX/ HAVELLES
Supply, erection of 0.51 mm jelly filled armored telephone cable loose in existing pipe/tranches including testing & commissing charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (NS) (i) 20 Pair Make:- DELTON/ FINOLEX/ HAVELLES
Supply, erection, laying and testing of D.P. including the cost of krones, base plate, 40mm dia G.I. pipe for incoming and outgoing cable and main box having locking arrangement. (NS) (i) 20 Pair DP Make:- DELTON/ FINOLEX/ HAVELLES
Rajender Godara
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .