Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹29.0 L+₹2.2 L (8.25%)Rejected-Finance | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹39.0 L+₹12.2 L (45.7%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
8 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
PROVN OF DIVERSION OF HT ELECT SUP LINE AT CHANGSARI UNDER GE RANGIYA
2020_MES_401447_1
CWE/TEZ(R)/T-44 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Rangiya
As per tender documents
8 documents required · 8 mandatory
₹500
GE Rangiya
₹76,000
Yes
22 Jan 2021
7 Dec 2020
11 Jan 2021
7 Dec 2020
8 Jan 2021
21 Dec 2020
75 days
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, and getting out soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/loose soil complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soil complete all as specified and as directed.
M & L for sand cushioning (dry) in trenches for protection of UG cables below, above and around the cables laid in trenches) of 230 mm spreading thickness and consolidated upto180 mm thickness complete all as specified and as directed.
Supply and laying in trenches GI Pipe 80 mm bore light grade for prorection of UG cable complete all as specified and as directed.
Supply laying,testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade with fixing all accessories of 120 sq mm 3 core all as specified and directed.
Supply laying ,testing and comissioning XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 300 sqmm 3.5 core including all necessary items as per site requirement complete all as specified and directed.
Supply and laying sub class old size B Bricks, well burnt, laid in breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
Supply, install, testing and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 150 KVAR (6 steps 25 KVAR x 6) complete all as specified and directed.
Supply, installation, testing and commissioning of servo voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 8 Volts per second and of capacity 300 KVA including all accessories as recommended by manufacturer complete all as specified and as directed.
Supply, install, testing and commissioning of HT 11 KV, 3 Phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker having rupturing capacity 250 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 400 Amps complete all as specified and directed.
M &L for Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps for 11000 volts complete all as specified and directed.
Supply, installation, testing and commissioning of out door type, platform mounted step down transformer of capacity 315 KVA, 11/0.433 KVA (at No load), AC 3 phase, 50 Hz, core type double copper wound, oil immersed naturally cooled, Oil natural - Air natural (ON/AN) with external cooling tubes,delta connection on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-II with Neutral brought out secondary side (LV side) and having tapings at (-) 2.5% & (+) 5% on HV side to be changed by means of hand operated OFF load tap changer gear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature of 40 degree celsius as per IS-1180. Transformer shall comprises of the following:-
(a) HT side (Primary side) consisting of three Nos porcelain bushing with copper rods complete with nut & washers, HT bushing suitable for outdoor mounting transformer, 1100 Volts grade.
(b) One cable box LT side (secondary) consisting of four Nos porcelain bushing complete with nut&washers with on No cable gland suitable for reception LT 1100 Volts grade XLPE insulated and PVC sheathed heavy duty armoured cable of suitable size complete.
(c) Oil conservator with filter type drain valve and oil level gauge complete.
(d) De-hydrating breather with first fill of dehydrating agent (Silica gel).
(e) Explosive vent & thermometer pocket on tank cover, oil level gauge, oil drain filter valve, lifting lugs, oil filling hole with cap/plug with connection plate complete, Air release valve plug and four Nos solid cast steel detachable rollers with lock pin.
(f) One 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
(g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm earth strip for earthing of neutral & body.
(h) Rating plate and terminal marking plate.
(j) First filling of transformer oil as per IS-335 (original sealed barrel to be used) filtered and tested upto 40 KV dielectric strength at 2.5mm air gap between testing electrodes.
(k) Including suitable RCC foundation as per the design recommendation of OEM. Top of the foundation room the ground level would be of min 900mm.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth by iron strip 32x6 by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class EHV, Type 1 with peak, size 450mm x 230mm x 50mm complete all as specified and directed.
M&L cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm
M&L cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
M.S. Construction
Jitu Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .