General Manager, Zone-7, U.P. Projects Corporation Ltd. Lucknow. Gomti Barrage, Left Bank, Gomti Nagar Lucknow
FIRE FITING WORK OF 100 BEDDED HOSPITAL SIRAULI GAUSPUR, BARBANKI (U.P.)
2026_UPPRC_1210598_1
75/UPPCL/GM-7/E-TENDER/2026-27 Dated-19.11.20266
Open Tender
Civil Works
Percentage
180 days
SIRAULI GAUSPUR, BARBANKI (U.P.)
As per BID Document
2 documents required · 2 mandatory
₹17,700
₹3.3 L
21 Nov 2026
21 Nov 2026
7 Dec 2026
21 Nov 2026
7 Dec 2026
21 Nov 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | FIRE PUMP WORKS FOR HYDRANTS & SPRINKLER SYSTEM | - | - | - | - |
| 2 | FIRE PUMPS - ELECTRICAL Supply, installation, testing and commissioning of electrically driven fire-pump, suitable for automatic operation consisting of the following: Horizontally mounted end suction centrifugal pump, suitable for operation on 415 volts ± 10%, 3 phase, 50 HZ A.C supply, complete with flexible coupling and coupling guard as required. Fire pump having C.I. body, bronze impeller and S.S Shaft with mechanical seal, capable for delivering 2850 LPM of water at 90 mts head to ensure a minimum pressure of 3.5 kg/cm2 at the terrace/farthest hydrant. (The pump should meet the condition of Local fire Authority). Squirrel cage induction motor, TEFC type of suitable rating for operation on 415 volts, 3 phase 50 Hz A.C supply, for the above pump with synchronous speed of 2900 RPM. Common base plate for above pump and motor from M.S. Channel as required size. | - | - | - | - |
| 3 | 2220 lpm at 70 m Head | 1 | Set | 2,71,778.29 | ₹2,71,778.29 |
| 4 | FIRE PUMPS - DIESEL ENGINE DRIVEN Supply, installation, testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following:
Horizontally mounted end suction single/multi stage, single/multi outlet centrifugal pump, suitable for operation on 415 volts ± 10%, 3 phase, 50 HZ A.C supply, complete with flexible coupling and coupling guard as required. Fire pump having C.I. body, bronze impeller and S.S. Shaft with mechanical seal, capable for delivering 2850 LPM of water at 90 mts. head to ensure a minimum pressure of 3.5 kg/cm2 at the terrace/farthest hydrant. The pump should meet the condition of Local fire Authority/NBC). Water/Air Cooled Diesel engine (4 CYLINDER ENGINE) of speed 1800 RPM for the above pump with automatic starting mechanism (AMF autostart panel complete with necessary relays like no volt relay, over voltage and low voltage relays, contactors, timer, pressure switch etc. as required for the auto start of the diesel engine in case of power failure complete with all accessories, wiring & cabling) and other accessories including fuel tank fabricated from 3mm MS sheet painting with two coats of synthetic enamel paint over a coat of primer) capacity 200 Its. Diesel Engine oil and Coolant required for Testing & Commissioning & First Fill of Fuel to be in Contractor's Scope MH with cover drain valve, Air vent hydraulic pumps including structural supports (painted with approved shade), Hard Rubber Tubing of necessary length to connect Diesel Tank with Diesel Pump, necessary Pressure Reducing Valve, 2 Nos. x 12 volt battery, heat exchanger with necessary piping connection. | - | - | - | - |
| 5 | 2280 lpm at 56 m Head | 1 | Set | 4,50,723.93 | ₹4,50,723.93 |
| 6 | JOCKEY PUMP Supply, installation, testing and commissioning of jockey pump comprising of the following:
Horizontally mounted end suction single centrifugal pump, suitable for operation on 415 volts ± 10%, 3 phase, 50 HZ A.C supply, complete with flexible coupling and coupling guard as required. Fire pump having C.I. body, bronze impeller and S.S. Shaft with mechanical seal, capable for delivering 180 LPM of water at 90 mts. head to ensure a minimum pressure of 3.5 kg/cm2 at the terrace/farthest hydrant. The pump should meet the condition of Local fire Authority).
Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase, 50 HZ AC supply for the above pump with a speed of 2900 R.P.M. with flexible coupling and coupling guard etc. as required.
Common base plate for above pump and motor from M.S. channel as required size. | - | - | - | - |
| 7 | 180 LPM 70M HEAD | 1 | Set | 76,072.94 | ₹76,072.94 |
| 8 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out
of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size
copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD
specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : | - | - | - | - |
| 9 | INCOMING
630 A, 50kA 4 pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630A) with selector switch & CTs etc.
LED type RYB phase indicating lamps. ON, OFF, trip indicating lamps.
Set of Copper Bus Bar 800Amps. | - | - | - | - |
| 10 | BUSBAR Electrolytic high conductivity aluminium three phase and neutral busbars rated at 630Amp having a maximum current density of .8 amp per sq.mm suitable to withstand symmetrical fault level of 25 MVA at 415 volts. The neutral busbar is to be of 100% capacity. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.52 MB
BID75.pdf
Tender Documents • 25.80 MB
BOQ_2299883.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .