| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.1 L+₹76,620 (7.41%)Rejected-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-AOC L2 | |
| 3 | L3₹11.8 L+₹1.5 L (14.2%)Rejected-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L3 | Rejected-AOC L3 | |
| 4 | L4₹12.5 L+₹2.1 L (20.7%)Rejected-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-AOC L4 | |
| 5 | L5₹12.8 L+₹2.5 L (23.9%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹15.0 L
EMD Value
₹29,960
Closing Date
4 Dec 2023, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore-63
REPAIR/MAINTENANCE OF INTERNAL WIRING, LIGHT FITTINGS AND CONNECTED WORKS AT CQAE (WE) UNDER GE (AF) YELAHANKA
2023_MES_627046_1
8221/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹29,960
Yes
11 Jan 2024
6 Nov 2023
11 Dec 2023
6 Nov 2023
4 Dec 2023
20 Nov 2023
Amount
Taking down unserviceable wire carefully copper/ aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., and making good the disturbed surfaces of walls, ceiling etc., including painting with same colour of the background, complete all as specified and as directed.
Taking down carefully Unserviceable Sub main wiring of any size and type batten or conduit, surface or concelaed including removing material from site and making good the disturbed surfaces of walls, roofs etc to match the existing complete all as specified and as directed. Note: 1. Taking down of Fittings and Fixtures shall be measured under respective Items Separately. 2. 3 run of wire and 1 run of conduit shall be measured as one unit.
M & L for Point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit incl accessories surface type run on walls/ ceiling including MS terminal boxes mounted concealed on walls with suitable size moduler cover plate inner and outer fixed with machin screws for housing the moduler switches, switch socket , fan regulators etc., including provision of 1.5 Sqmm FRLS PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following:
(a) One Light point controlled by one switch
(b) One fan/Ex. fan point controlled by one switch.
(c) One 5A 2pin/3pin switch socket out let multipurpose on independent Board.
(d) One call bell point controlled by one bell push
All as per item No -03 above but wiring complete with 2.5 Sqmm for 5 pin 5/15A socket multipurpose on independent board all as specified and directed. Note :- item No 03 to 04 (i) The earth wire for the points shall be laid from the respective switch board only . (ii) Earth wire shall be taken inside the conduit (iii) Cost of MS terminal box and moduler cover inner and outer are deemed to be included in the item rate quoted for point wiring
M & L for Point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through existing conduit run on walls/ ceiling , incl provision of 1.5 Sqmm FRLS PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
(a) One Light point controlled by one switch
(b) One fan/Ex. fan point controlled by one switch.
(c) One 5A 2pin/3pin switch socket out let multipurpose on independent Board.
(d) One call bell point controlled by one bell push
All as per item No -05 above but wiring complete with 2.5 Sqmm for 5 pin 5/15A socket multipurpose on independent board all as specified and directed.
S & F in repair Modular Switch 1 way 6 Amps 1 Module complete all as specified and directed.
S & F in repair Modular Socket,6 Amps- 2/3 pin combined 2 Moduler complete all as specified and directed.
S & F in repair Modular Switch 1 way 16 Amps 1 Moduler complete all as specified and directed.
S & F in repair Modular Socket,6 A/16A,2 Moduler complete all as specified and directed.
S & Fin repair Modular bell push 6A,1 Module complete all as specified and directed.
S & F in repair Modular type Fan step regulator 120W type 2 moduler complete all as specified and directed.
S & F in repair Switch piano flush type, single pole, one way 5 Amps complete all as specified and directed.
S & F in repair Switch socket combination 2 -in-1, 3 pin/5 pin, 5 Amps 230 volts complete all as specified and directed.
S & F in repair Switch Socket Combination 2 in 1, 3 pin 5 Amps and 15 Amps flush type , 230 volts complete all as specified and directed.
S & F in repair step type electronic fan regulator, - 2 module complete all as specified and directed.
S & F in repair PVC ceiling rose two to three terminals all as specified and directed
S & F in repair ding dong bell AC, 230 volts, single pole complete all as specified and directed.
S & F in repair PVC Gang box 4" x4" suitable for 5 Amp S/S combination complete all as specified and directed.
S & F in repair PVC Gang box 6" x 4" suitable for 15 Amp S/S combination complete all as specified and directed.
S&F in repair Angle holder PVC/polycarbonate type all as specified and as directed
Supply and fixing in repair 600x600mm surface/ recessed mounted LED Light fitting 36 W,glare free uniform illumination acrylic diffuser,connector block etc., complete with all accessories and including connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed.
Supply and Fixing in repairs LED Tube light fitting 1 x20 W, 6500K 220V ( 4 feet long ) Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient box type with driver,holder including LED tube light connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed.
Supply and Fixing in repairs LED Tube light fitting 1 x10 W, 6500K 220V ( 2 feet long ) Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use box type with driver,holder including LED tube light connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed.
Supply and Fixing in repairs MCB DB SPN 8 way, Double door, 240 V, AC, 50 Hz, with 200Amp rated bus bar complete all as specified and directed.
Supply and Fixing in repairs Metal clad switch socket Single pole and neutral enclosure with a two pin and earth plug and socket complete with One single pole MCB SP 20 Amps and fixed in walls Complete all as specified and as directed.
Supply and Fixing in repairs MCB DB TPN 4 way, double door,415 V, AC, 50 Hz complete all as specified and directed.
Supply and Fixing in repairs MCB SP 5 to 32 Amps rating, 10 KA Ç 'curve 240V, 50 Hz AC Complete all as specified and as directed.
Supply and Fixing in repairs MCB SPN 32 Amps rating, 10 KA 'C 'curve, 240V, 50 Hz AC Complete all as specified and as directed.
Supply and Fixing in repairs MCB TP 25- 63 Amps rating, , 10 KA Ç' crve 415V, 50 Hz AC complete all as specified.
Supply and Fixing in repairs MCB TPN 63 Amps rating,, 10 KA Çcurve , 415V, 50 Hz AC Complete all as specified and as directed.
Material and Labour for sub main wiring 1100 volts grade PVC insulated FRLS multistranded copper conductors, two runs of single core 4 Sqmm along with one run 4 Sqmm PVC insulated single core FRLS multistranded copper conductor cable as earth continuity conductor along with one run of PVC medium grade conduit all as specified and as directed
Material and Labour for sub main wiring 1100 volts grade PVC insulated FRLS multistranded copper conductors, two runs of single core 2.5 Sqmm along with one run 2.5 Sqmm PVC insulated single core FRLS multistranded copper conductor cable as earth continuity conductor along with one run of PVC medium grade conduit all as specified and as directed. Note :- item No- 32 and 33 - 3 run of multistranded copper conductor and 1 run of PVC conduit shall be measured as one unit complete all as specified and direced.
Disconnecting the powersupply and taking down Ceiling fan ,Dismantling the defective Ceiling fans motor 1200mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material and other petty items required for making motor functional Complete all as specified and as directed.
Disconnecting the power supply and taking down the exhaust fan , dismantling the defective Exhaust fans motor 250mm to 300 mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, and other petty items required for making motor functional Complete all as specified and as directed.
Disconnecting the power supply and taking down the exhaust fan dismantling the defective Exhaust fans motor up 450 mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, and other petty items required for making motor functional Complete all as specified and as directed.
Disconnecting the power supply and taking down the wall mounting fan 600mm , taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, and other petty items required for making motor functional Complete all as specified and as directed. Note: item No -34 to 37 - Spares will be measured and paid separately as supply only under relevant items of this schedule.
Material and Labour for Painting of Ceiling fan 1200mm sweep,exhaust fan any size and wall mounting fan any size complete, at site with synthetic enamel paint by spraying painting including filling cavities with filler,one coat after cleaning including writing MES Nos Complete all as specified and as directed.
Hanging Only Ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost Complete all as specified and as directed.
Fixing only Exhaust fan any sweep and connecting up including nuts and bolts if required and provison of cable from ceiling rose /connector to fan complete all as specified and directed.
Supply Only GM bush suitable for Ceiling fan 1200 Sweep Complete all as specified and as directed.
Supply Only Ball bearings suitable for Ceiling fans / Exhaust fans / Wall mounting fans upto 1200 Sweep Complete all as specified and as directed.
Supply Only 2.5 MFD Capacitors for the fan in position Complete all as specified and as directed.
Supply Only 4 MFD Capacitors of the fan in position Complete all as specified and as directed.
Material and labour for repairing /replacing the perished door hinges, rubber beeding of existingdistribution board with meter box at various building approx 1.2Mx .75Mx 0.5M, scraping and removing the old paint , rust and dust ,painting two coat of red oxide over a coat of synthatic smoke gray enamel paint and writting the distribution area of qtr no all as directed at site.
Taking out unserviceable geyser element Supply and fixing heating element suitable to existing model and make 2 KW Dual clip type/tri angle type / round type with rubber gasket suitable for geysers up to 50 Ltr capacity all as specfied and directed
Taking out unserviceable thermostat Supply and fixing thermostat clip type (Range 30 C° to 80 C and acting at 70 C°) for geysers up to 50 Lts all as specified and directed.
Taking out un serviceable PVC connection Supply and fixing 15mm borePVC connections with brass nuts 650 mm in length suitable to connect GI pipe 15 mm dia to hot /Cold water outlet of geyser. Complete all as specified and directed by Engr-in- charge
Taking out unservice pressure release valve Supply and fixing pressure release valves suitable for geyser up to 50 ltrs capacity type asper existing PR valve complete allas specified and directed by Engr-in- charge
Taking out unservice indication lamp Supply and fixing indicating lamps green / red suitable for geysers up to 50 Ltrs complete all specified and directed by Engr-in- chrge
Supply and Fixing in repairs MCCB Triple pole 415 volts 50 HZ AC suitable for current carrying capacity 25 to 100 Amps rating, fixed type with rupturing capacity 16 KA all as specified and directed.
M&L for earthing complete with galvanised iron earth plate electrode of size 600mm X 6oomm X 6mm thick buried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including galvanised earth wire 4mm dia (up to 7.5 m length) as earthing lead fixed by means of bolts nuts check nuts washers of galvanised iron and connect to main switch and including GI pipe light grade 15mm bore protection pipes necessary excavation and earth work in any strita pcc chamber in PCC 1:3:6 type CI PCC 1:2:4 type B1 cover slab 50mm thick width 8mm dia TMT bars @ 100mm c/c both ways with lifting handle watering pipe of GI medium grade 20mm dia, wire mesh funnel lugs charcoal, salt etc all as applicable and as per plate N0 3 of SSR part-1 connected to earthing test point including taking out old earthing materials and all as specified and directed .
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type (Bldg security light) with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing PVC insulated flexible copper cable 3 core 2.5 sqmm complete all as specified and directed.
Supply and fixing round shape 12 watt 220 volts AC recesse cum surface panel solution type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Material and Labour for complete servicing after pumping down Indoor/outdoor units of split AC complete by cleaning condenser/ Evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, cleaning the air filter, connecting up all connections and testing after gas charging if required all as directed for Split type Air Conditioner up to 1.5 Ton all as specified and directed. Notes :- (i) The rate deemed includes for minor spares. However, spares like capacitor, thermostat, fan blades, bower bush, relays shall be measured as supplied only under relevant items of schedule. (ii) Gas shall be measured and paid separately under relevant item.
All as per item No.57 here in before but for Split type Air Conditioner 2.0 Ton all as specified and directed.
Taking out burnt/ unserviceable sealed compressor Unit from split type air conditioner, Supply & replacement factory sealed compressor unit, connecting refrigeration system after thorough flushing out the system with dry nitrogen, leak testing with nitrogen, vaccumising and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit all as directed for Split type Air Conditioner 1.5 Ton. Notes:- (i) Factory sealed compressor unit shall be of existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separately under relavent item
All as per item No 59 here in before but Split type Air Conditioner 2.0 Ton
Material and Labour for removing the Split type Air conditioner outdoor unit/indoor unit from installed position leak testing & arresting the leakages in condenser coil by brazing etc complete for Split type AC 1.5 ton / 2.0 ton / 2.5 ton. Note :- Gas Charging shall be mesasured and paid separately under relavent item
Taking down the Unserviceable IDU blower motor and Supplying and Fixing IDU blower motor capacity as per existing make all as directed for 1.5 Tr split AC complete all as specified and directed.
Taking down the Unserviceable IDU blower motor and Supplying and Fixing IDU blower motor capacity as per existing make all as directed for 2.0 Tr split AC complete all as specified and directed.
Taking down the Unserviceable Condenser fan blade of split AC and Supplying and Fixing as per existing make all as directed for Condenser fan blade 1.5 Tr complete all as specified and directed.
Taking down the Unserviceable Condenser fan blade and Supplying and Fixing as per existing make all as directed for Condenser fan blade 2.0 TR complete all as specified and directed.
Taking down the Unserviceable Condenser fan motor and Supplying and Fixing as per existing make all as directed for 1.5 TR split AC complete all as specified and directed.
Taking down the Unserviceable Condenser fan motor and Supplying and Fixing as per existing make all as directed for 2.0 TR split AC complete all as specified and directed.
Supply only Starting Capacitor of 80 / 100 mfd for AC complete all as specified and directed.
Supply only Running Capacitor 36 / 45 mfd for AC complete all as specified and directed.
Supply only Thermostat complete all as specified and directed.
Supply only capacitor 1.5 mfd to 4 mfd for blower motor complete all as specified and directed.
supply only swing blade opertated motor for indoor split unit up to 2 ton complete all as specified and directed.
Supply only Blower bush for indoor split unit up to 2 ton capacity
Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 1/2 " x 1/4" complete all as specified and directed.
Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 5/8 " x 1/4" complete all as specified and directed.
Taking down perished Unserviceable insulation cover of refrigerent piping and Supplying & Fixing brutile rubber insulation for refrigerent pipings of suitable size complete all as specified and directed.
Taking out existing Unserviceable Remote Control and Supplying & Fixing Remote Control for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as directed.
Taking out existing Unserviceable Air Filter and Supplying & Fixing Air filter for Split type 1.5 ton / 2 ton complete all as directed.
Supplying and Fixing PVC flexible Conduit pipe 20mm dia medium grade including all accessories for drain out pipe all as directed.
Supply Only Relays for Split type AC 1.5 ton / 2.0 ton complete all as directed.
Pumping down the AC Compressor before dismantling inner and outer units disconnecting electric connections also without any damage to existing system, reinstalling of inner and outer units in new locations Complete with brackets and civil works (making holes in wall) complete finishing as required, assembling of inner & outer units including connection of suction and discharge pipes, testing connection etc with topping up refrigerant gas as required to maintaining pressure all as specified and directed.
Material and Labour for charging of refrigerant gas R-32 / R-134A to Split type air conditioner after vaccumising the complete system & pressure test with nitrogen to ensure complete system leak proof, testing of air conditioners for proper functioning & cooling effect to the entire satisfaction of Engineer in Charge
Supply and fix XLPE insulated, armoured heavy duty electric cable with aluminium onductor, 1100 volts grade, cross-sectional area 4 sq. mm 2 core including taking out existing old complete all as specified and directed.
Supply and fix in repairs of non rigid PVC conduit of size 20mm complete all as specified and directed.
Supply and fixing post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including taking out unserviceable one complete all as specified and directed.
Supply and fixing LED bollard fitting 10 W , IP-65 230 Volts including taking out unserviceable one all as specified and directed.
Disconnecting the power supply and taking down the wall mounting fan dismantling the defective Wall mounting fan motor 450 mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, and other petty items required for making motor functional Complete all as specified and as directed.
M/S SRI BALAJI ENTERPRISES
Shiva Shakthi Electrical Enterprises
ANAND REFRIGERATION
M/S Sneha Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .