| 1 | L1₹40.4 LAccepted-AOC SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.5 L+₹1.2 L (2.80%)Rejected-Finance HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹51.5 L+₹10.2 L (24.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
11 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Utilities) Udhampur
GE (Utilities) Udhampur, PO-Garhi, Pin-182121
Repair/Maint of LT network and security lights at CHNC and other areas under GE (Utilities) Udhampur
2025_MES_714423_1
GE/U-40/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹1 L
1 Aug 2025
13 Jun 2025
14 Jul 2025
13 Jun 2025
11 Jul 2025
27 Jun 2025
Amount
Taking out old defective LT UG cable from trenches /floors/ road/wall/pole/pipe of any size descripitonincluding disconnecting the connection from OH lines and main DB ,complete all as specified and directed by Engineer-in-charge
S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 240 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge
S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 185 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge
S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 150 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge
S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 70 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge
S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 35 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge
S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 25 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge
S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 16 sqmm 2 core, complete all as specified and directed by Engineer-in-charge
Supply and fixing GI pipe light grade 80 mm bore for cable protection fixed to poles with clamps/along wall/floor/under road/across the drain or nallah , complete all as specified and directed by Engineer-in-charge (M S Clamps ,bolts, nuts,shall be measured and paid seperatly)
Material and labour for making the hole under road and hard standing suitable for laying and inserting pipe upto 100 mm dia any length by mechanical drill system or Auger system and making the surface good as existing surface, complete all as specified and directed by Engineer-in-charge.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for taking out of unserviceble /laying new LT under ground cable, complete all as specified and directed by Engineer-in-charge
Returning, filling in,including spreding ,levelling ,watering and well ramming in layers not exceeding 25 cm thick , complete all as specified and directed by Engineer-in-charge
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point c, complete all as specified and directed by Engineer-in-charge
S&F double walled corrugated (DWC) pipe of size 90/76 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as spd and directed, complete all as specified and directed by Engineer-in-charge
S&F double walled corrugated (DWC) pipe of size 77/63 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground , complete all as specified and directed by Engineer-in-charge
Opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size 2 to 4 core from main switch/DB/Junction boxes LT OH Line,taking out the required length of cable from existing loop,cutting the defective portion of cable, providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junction boxes LT/OH Line etc all as directed. Note (i) The cost of required earth work ie excavation,returning filling relaying of sand and bricks and cost of drawing the required length from protection pipe breaking of required brick work/plaster/concrete and redoing the required work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account (ii) Additional cable/protection pipe required at stie if any shall be measured and paid separately.
Supply and fixing in replacement of MCCB, 4 pole, 415 volt of capacity 630 amp,Ics=50%Icu short circuit, breaking capacity not less than 50 KA , thermal setting 80 to 100 % confirming to IEC-947, IS-13947 , including thimbles, nuts, bolts ,washers etc disconnecting and making incoming , out going connections , complte all as specified and directed by Engineer-in-charge Make:- HPL,Havells,Legrand
Supply and fixing in replacement of MCCB, 3 phase, 4 pole, 415 volts of capacity 400 Amps, breaking capacity not less than 35/36 KA, thermal setting 80-100%, Ics=100% Icu conforming to IEC-947, IS-13947 including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and directed by Engr-in-Charge. Make:- HPL,Havells,Legrand
Description all as per item No 18 here-in-before but capacity of MCCB 250 Amps 25 KA Make:- HPL,Havells,Legrand
Description all as per item No 18 here-in-before but capacity of MCCB 200 Amps 25 KA Make:-HPL,Havells,Legrand
Description all as per item No 18 here-in-before but capacity of MCCB 160 Amps 25 KA Make:- HPL,Havells,Legrand
Description all as per item No 18 here-in-before but capacity of MCCB 100 Amps 25 KA Make:-HPL,Havells,Legrand
Description all as per item No 18 here-in-before but capacity of MCCB 63 Amps 25 KA Make:- HPL,Havells,Legrand
Supply and fix MCB TPN 415 volts 63 amps with 10KA breaking capacity, complete all as specified and directed by Engr-in-Charge. Make:- HPL,Havells,Legrand
Supply and fixing in replacement of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 2000 Amps complete all as specified & Directed by Engr-in-Charge. Make:- HPL,Havells,Legrand
Supply and installation including testing and commissioning of SMF Battery 2 Volts, 28 AH with battery copper terminals / thimples, battery inter-connection copper cable 16 Sqmm etc, complete all as specified and directed by Engr-in-Charge. Note:- Minimum Replacement manufacture warranty for 2 years.
M&L in replacement of Copper lugs suitable for 300 Sqmm Copper cable including taking down the existing unserviceable one complete all as specified and directed by Engr-in-Charge.
Description all as per item No 27 here-in-before but for 240 SQMM
Description all as per item No 27 here-in-before but for 185 SQMM
Description all as per item No 27 here-in-before but for 120 SQMM
Description all as per item No 27 here-in-before but for 95 SQMM
Description all as per item No 27 here-in-before but for 70 SQMM
Description all as per item No 27 here-in-before but for 50 SQMM
Material and Labour for earthing complete with galvanized iron of street or earth plate of size 60cmx60cmx6 mm thick buried directly in ground. Vertically total depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 32x6 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer ( including making of test point with GI strip of size 32x6 mm) including GI protection pipe 40 mm light grade dia for protection of strip upto test point all as directed GI pipe medium grade 20 mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40 mm graded stone aggredates complete including excavation and earth work, all as specified and show in plate No 3 of SRR-2009 Part-1, PCC pit shall be provided at least 50cm away from the earth pit and not just on earth pit including testing on completion, complete all as specified and directed by Engr-in-Charge.
M&L in replacement of PVC insulation tape roll 25 mm X 25 Mtr (LT) including taking down the existing unserviceable one complete all as specified and directed by Engr-in-Charge.
M & L in replacement for heat shrinkable straight through joint for PVC/XLPE insulated armoured cable of size upto 90 Sqmm 3.5/4 core complete all as specified and directed by Engr-in-Charge.
Opening, maintenance and general servicing of servo voltage stabilizer of capacity 1250 kVA incuding removal of sludge from disserstate coils, buck boost transfomers, tightening of all nuts and bolts, cleaning of stabilzer coils, checking and servicing of servo mechanisam, gear, syncronising system, automatic voltage regulator circuits and other allied electrical components complete all as specefied and directed by Engr-in-charge. Note : (a) The entire work shall be got executed through OEM i.e. M/s Electric Instrumentation only. The contractor shall submit the record of cleaning/services carried out by M/s Electric Instrumentation.complete all as directed. (b) Voltage stabilizer must be repaired by original manufacturer or by authorised service provider of the company. (c) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item (d) All T & P and transportaion arrangement are deemed to be included in the rates quoted.
Supply only following parts suitable for three phase servo voltage stabilizer 1250 kVA capacity as per existing make or as recommanded by original stabilizer manufacturer ie M/s Electric Instrumentation only complete all as specified and directed.
Control card H-999
Control card J-1195
THH Transformer T-HH
Step Syn Motor 20kg SS-202
RFP Card REP-301
Pot meter 5k 1W
Carbon Brush
Tension spring
E-Wire 200 AMPS
Carbon brush holder
M&L for Dehydration including filtration and cleaning of Servo Voltage Stabilizer oil by dehydrating machine incl testing of sample before and after dehydration and filtration all as specified and directed NOTE:- dehydration machine and testing kit will be provided by the Cont.Sample testing will be carried out in the presence of Engr-in-Charge on site.
Supply & Filling /pouring of up to the appropriate level Servo Voltage Stabilizer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed NOTE:- Dielectric strength test shall be carried out at site before poring/filling in Servo Voltage Stabilizer in the presence of Engr-in-Charge on the site
M & L Preparing surfaces of Servo Voltage Stabilizercomplete body and applying painting two coats of superior quality synthetic enamel paint using spray gun including sticker work and writing of MES/SM Nos etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LT junction box cubical type of size 60x40x30 cm,415 volts for outdoor use made out of CRCA sheet 3.15 mm thick powder coated ,machine pressed front opening with single door with provision of rubber beading and locking system including aluminium bus bar 4 strip of size 30 mm wide and 6 mm thick with provision of hole on bus bar fixing of cable mounted on PVC / epoxy insulators, mounted on angle legs of size 25x25x5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer ,legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete including all provision of opening for incomming/outgoing cables and testing complete all as directed by Engineer-in Charge.
M&L for reparing/servicing of APFC panel board of Cap 300 KVAr by replacing the all defective components with new components, rewiring, cleaning, testing, reconnecting, reinstalling and commisssioning the APFC panel boad complete all as direcetd by Engineer-in-Charge. Note : a) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item (b) All T & P and transportaion arrangement are deemed to be included in the rates quoted.
S&F in replacement of VIFmeter, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB TP 63A 10kA , complete all as specified and directed by Engr-in-Charge.
S&F in existing panel of Capacitors mixed dielectric type 3Ph 440v AC 12.5 KVAR, complete all as specified and directed by Engr-in-Charge.
S&F in existing panel of LED indication lamps 230VAC SP R Phase, complete all as specified and directed by Engr-in-Charge.
S&F in existing panel of LED indication lamps 230VAC SP Y Phase, complete all as specified and directed by Engr-in-Charge.
S&F in existing panel of LED indication lamps 230VAC SP B Phase, complete all as specified and directed by Engr-in-Charge.
S&F in existing panel of APFC Relay 12 Stage , complete all as specified and directed by Engr-in-Charge.
Calliberation of APFC Relay , complete all as specified and directed by Engr-in-Charge.
S&F in existing panel of capacitor switching duty contactor suitable for 12.5 KVAR , complete all as specified and directed by Engr-in-Charge.
S&F new 2 HP monoblock pump set drip proof, capacitor start, continuous duty rated, thermally protectd fluid temp to 220 degree F (104 Degree C), Body/Impellers - Noryl, 230 Vots, 50 Hz Flow rate Range to 40 gpm Maximum head 50 feet , complete all as specified and directed by Engr-in-Charge. Make : Kirlosker/Crompton/Mather & Plantt/KSB.
S&F new 0.5 HP monoblock pump set drip proof, capacitor start, continuous duty rated, thermally protectd fluid temp to 220 degree F (104 Degree C), Body/Impellers - Noryl, 230 Vots, 50 Hz Flow rate Range to 40 gpm Maximum head 50 feet , complete all as specified and directed by Engr-in-Charge. Make : Kirlosker/Crompton/Mather & Plantt/KSB.
Supply, Installation and commissioning of Air Compressor (7.5 HP) Double Stage Tank Cap 220 liter 8 Kg/cm2. All performance parameters are as per JIS standards - Duplex compressor mount on base frame- Low noise and vibration levels- Easy installation- Continuous and heavy duty operation- cost efficiency, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of pump/motor bearing No. 6317.ZZ series as per existing specification including taking down the old existing bearing, complete all as specified and directed by Engr-in-Charge. Make:-SKF/NBC or equivalent make
Supply and fixing in replacement of pump/motor bearing No. 6318.ZZ series as per existing specification including taking down the old existing bearing. Make:-SKF/NBC or equivalent make
Supply and fixing in replecement of 12 Amp,4pole, 415 Volts, 50 Hz Power contactor (MO12) auxilary contact 2 NO + 2 NC, of coil voltage 240 Volts, complete all as specified and directed. Make:Model No MO 12 of L&T/Schineider/Havells
Supply and fixing in replecement of 110 Amp,4pole, 415 Volts, 50 Hz Power contactor (MO110) auxilary contact 2 NO + 2 NC, of coil voltage 415 Volts, complete all as specified and directed. Make:Model No MO110 of L&T/Schineider/Havells
S&F in replacement LED building security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant completewith driver, lamp, clamps, suitable bracket with impact and corrosion resitant including thermal management in multiple optics complete with IP 65/66 protection , complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings , complete all as specified and directed by Engr-in-Charge. Make: Havells/Phillips/Bajaj/CG
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size , complete all as specified and directed by Engr-in-Charge. Make: Havells/Phillips/Bajaj/CG
Supply and fixing in replacement round shape LED luminaire 15 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size , complete all as specified and directed by Engr-in-Charge. Make: Havells/Phillips/Bajaj/CG
slathia construction works (BID ID -3347138)
PREM NATH KHAJURIA AND SONS (BID ID -3345421)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .