Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹29.6 L+₹17,605.80 (0.60%)Rejected-Finance AT VINDHANE POST DIGHODE TAL PANVEL DIST RAIGAD | RAIGAD | MAHARASHTRA | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹30.5 L+₹1.1 L (3.82%)Rejected-Finance | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹30.8 L+₹1.4 L (4.76%)Rejected-Finance RIDMALSAR PUROHITAN BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L4 | Rejected-Finance HIGHER | |
| 5 | L5₹32.4 L+₹3.0 L (10.2%)Rejected-Finance | L5 | Rejected-Finance HIGHER |
Tender Value
₹37.9 L
EMD Value
₹75,800
Closing Date
29 Apr 2024, 6:00 pmClosed
GE Amritsar
GE Amritsar pin 143001
SPECIAL REPAIR TO PANTHER COMN COMPLEX LINE BLDG NO P-33 UNDER GARRISON ENGINEER AMRITSAR CANTT
2024_MES_648910_1
GE/ASR-02/2024-25
Open Tender
Civil Works
Works
180 days
GE Amritsar
Class D category a i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹75,800
22 Sept 2024
1 Apr 2024
30 Apr 2024
1 Apr 2024
29 Apr 2024
15 Apr 2024
Amount
Dismantaling of brickwork, built in cement mortar including all quoins, arches, pillars, etc ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:4 ; Complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 2 above but except bricks (old dismantled serviceable bricks obtained from Srl item No 2 shall be reused after necessary cleaning of mortar)
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4 finishing even and smooth without using extra cement taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc; Complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 4 above but in CM 1:6 .
All as per ser item No 4 but 10 mm thick on ceiling surface in CM 1:3.
Material and Labour for preperation of old decorated surfaces of walls by complete removal of existing treatment by scraping and washing down with, removing all acales/dirts and greasy spots and applying two coats of oil bound distemper over and incl average 2mm thick wall putty after ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for preperation of New plastered surfaces of walls and applying two coats of oil bound distemper over a coat of promer over and incl average 2mm thick wall putty complete all as spcified and directed by Engr in Charge .
Material and Labour for applying two coats of whitewash on ceiling including preperation of newly plastered surfaces ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for applying two coats of whitewash on ceiling including preperation of OLD plastered surfaces ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for preparation of NEW plastered surfaces and applying two coats of cement base paint paint over a coat of cement primer on wall surfaces; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Preparing of OLD decorated brick/concrete plastered/un-plastered surfaces including scrapping of old existing treatment of walls pillars cornices applying two coats of cement base paint over coat of 2mm thick average wall care putty as required in depressions and making smooth surface ; Complete all as specified and directed by Engineer-in-charge.
Material and labour for Box type steel ventilator made of ERW tube P-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown on drg No CEJZ/TD-1019/08 dt 01.05.08 incuding cutting holes with and including 3mm thick pin headed type glass sheet glazing with oil putty and Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplesof appropriate size hold fast PCC 1:2:4 type B0 (four No’s for Each window) & around required plaster in CM 1:4 and match with existing finish complete including dismantling and taking down old unserviceable window all as specified and directed by Engineer-in-charge. Painting shall be measured and paid separately.
Supply and Fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
Supply and Fixing factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2,3 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face &2mm plain colour PVC sheet on back face, supplying and fixing in frame by means of three stainless steel hinges min 75mm size at site as per specification and drawing.
Supply and Fixing in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Sheet glass, 3mm thick ordinary quality, in squares, not exceeding 0.50 sqm in each pane including wooden beading or galzing with putty including ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Aluminium, anodised, barrel tower bolts 150mm of extruded section and fixed ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 150mm long Aluminium handles, cast type anodised; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for two coats of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described including prepration of old surfaces ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing non skid ceramic light coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 & including dismantaling of old tiling ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing glazed ceramic coloured tiles 450x300mmx7mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in CM 1:4 on brick surface including dismantaling of old tiling ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Mirror polishing the surface of existing kota stone flooring complete as follows and as directed by the Garrison Engineer. (a). Clean the floor and remove the dirt before polishing . (b). The surface shall be groung evenly via machine fitted with fine grade grit block (No 120). (c). After cleaning the surface grinding the surface should be prepared by thoroughly washing and cleaning for final grinding. (d). Final grinding should be done the day after the first grinding with machine fitted with the finest grade grit blocks (No 320). (e). The polished surface is then rubbed hard with oxalic acid sprinkled with water and spraid at the rate of 33 gms per sqm using pad of woolen regs (f). The mirror polshing shall be done to the entire satisfaction of GE
Material and Labour for Machine cut Kota stone slab flooring 20-25 mm thick (size not less than 0.5 sqm each) over cement screed base of 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including demolition of old stone slabs ; Complete all as specified and directed by Engineer-in-charge.
Demolition of cement Concrete in sunken floors exc 15cm thick ( above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in sides of sunken slab benching etc including necessary form work ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Rendering 15mm thick cement plaster as in sunken portion in cement mortar 1:3 using water proofing compound, finished fair and even without using extra cement complete all as specified. (WPC measured saperatly)
Supply only integral water proofing compound ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 40mm bore steel water tubing grade galvanised inserted at the end of lateral slope projecting atleast 25cm beyond the outermost part of the building below the drain pipe up to two storey construction as spout for sunken, and all joints should be sealed properly by epoxy sealent ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour Water proofing treatment to sunken floor including wall comprising with the following course of treatment/ specification from bottom to top. (a) Applying bituminous primer @ 0.40 ltrs per sqm over plastered surface of floor for treating the sunken floor all as specified & as directed by Engr-in-Charge. (b) Apply a coat of hot bitumen 85/25 penetration grade bitumen @ 1.20 kgs/Sqm. (c) One layer of 3mm thick APP film based poly meric membrance minimum weighing 3Kg per Sqm reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application over entire area, complete all as specified and directed. Note:-(i) After plastering testing tobe carried out by ponding (For 48 Hrs) and any leakage/Seepage observed shall be rectified before water proofing treatment. (ii) Laying of APP membrane shall be done as per manufracturers instructions . (iii) Joints tobe touched hot and Minimum width of overlaps not less than 150mm.
Material and Labour for Plain cement concrete (1:5:10) type D-2 using 40mm graded stone aggregate as in sunken filling as mass concrete or in sub base of floors; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair vitreous China Squatting pan 'Orrisa' pattren size 580x440mm white with integral foot rest and PVC(SWR) 'P' trap 110mm bore ; Complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repairs vitreous china wash down water closet pan (padestal pattern) with flush pipe 32mm dia for low level flushing cistern including plastic water closet seat cover white , closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, PVC trap 110mm bore ,; Complete all as specified and directed by Engineer-in-charge.. (excluding flushing cistern).
Supply and Fixing in repair 10 Ltr capacity PVC valveless symphonic action type flushing cistern white low level with ball valve flote handle including bracket and flush pipe of polythylene of low or high density or PVC,32mm dia ; Complete all as specified and directed by Engineer-in-charge.
Demolition of reinforced cement concrete work as in slab,chajjas and similar suspended work ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in Repair vitreous China wash basin with pedastal white,flat back size550x400mm including CP waste coupling 32mm bore ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing WHB mixer cast copper alloy fancy type with capstan head chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe.
Supply and Fixing PVC connection 15mm size with PTMT nuts of length 600mm ; Complete all as specified and directed by Engineer-in-charge.
Supply & Fixing vitreous china urinal half stall type with CP spreader white with grating and union for discharge pipe, including providing and fixing plug, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement fixing with brackets, flush pipe, grating and union for discharge pipe ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair PVC waste pipe32mm dia fixed to WHB/Sink/urinal ; Complete all as specified and directed by Engineer-in-charge.
Dismantling water tanks Exc 250 Ltr & not exceeding 500Ltr and Supply and Fixing rotational moulded polythene, triple layers, water storage tank 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position including Supply and Fixing 20mm bore PTMT ball valve epoxy coated minium weight 210gms with aluminium rod ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down old tubing ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Galvanised iron steel water tubing, 20mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors including taking down old tubing ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 20mm bore, Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs brass chromium plated angle valve 15mm bore fancy type screwed down for high pressure ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair of brass cromium brass plated fancy type bib taps 15 mm bore long nose screwed down screwed for iron pipe or for brass ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair 15mm bore Stop valves, cast copper alloy, screwed down , high pressure, with crutch or butterfly handles , screwed both ends for iron pipe or for unions, fancy type, chromium plated with long shank and cup ( concealed type) and fixed ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs 125mm CP shower rose fancy type with CP arm ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs 100mm dia CP grating with or without hinge type or hole type ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs CP brass towel rail 600mm long ; Complete all as specified and directed by Engineer-in-charge.
Taking down eaves gutters and rain water pipes ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 110mm bore PVC(SWR) pipes single socketed in any length fixed to walls with dash true nut and bolt at every 2mtr length including) including all fittings complete all as specified and directed by Engineer-in-charge
Supply and Fixing 75mm bore PVC(SWR) pipes single socketed in any length fixed to walls with dash true nut and bolt at every 2mtr length including) including all fittings complete all as specified and directed by Engineer-in-charge
Supply and Fixing 110mm bore PVC (SWR) bends any radius With access door ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement ; Complete all as specified and directed by Engineer-in-charge.
Dismantling Brick tiles or terracing tiles, single layer on roofs ; Complete all as specified and directed by Engineer-in-charge.
Demolition mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed by Engr-in-Charge
Material and Labour for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing (minimum) 3mm thick APP film based poly meric membrance minimum weighing 3Kg per Sqm reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application over entire roof area with over lapping 100mm to either sides and sealed in after cleaning down the roof by brooms ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for 40mm thick brick tiles laid on m ud mortar and jointed grouted, flush pointing in Cement Mortar (1:3) mixed with 5% crude oil by weight of cement on flat roof over and including 20mm thick screed bed in cement mortar 1:6 ; Complete all as specified and directed by Engineer-in-charge.
Ditto all as per item No 60 here-in-before but except brick tile
Material and Labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in padding concrete fair finish avg 30mm thick, roof kerbs or mud stops, rounded or chamfered on edges and like including weathering slight rounded and throating ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for 50mm thick PCC 1:3:6 type C-1 (using 40mm graded stone aggregate as in plinth protection Finishing fair and even ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour PCC 1:1.5:3 type B0 using 12.5 mm graded stone aggregate for repair of Chajja, Fascia, parapets etc using chicken wiremes upto 4 m height including necessary formwork, scaffolding. And applying two coats of cement base paint over coat of primer over cement plaster 1:4 ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour PCC 1:1.5:3 type B0 using 12.5 mm graded stone aggregate for repair of Chajja, Fascia, parapets etc using chicken wiremes height exc 4 m but n.exc 9m including necessary formwork, scaffolding. And applying two coats of cement base paint over coat of primer over cement plaster 1:4 ; Complete all as specified and directed by Engineer-in-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc.; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated unsheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, ISI marked, not less than 20mm bore with conduit accessories concealed in wall, fixing with clamps on ceiling/roof etc., with pressed steel terminal boxes of suitable size & modules, concealed in walls incl plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as directed. One light point/Fan point controlled by one switch NOTE: Pressed steel terminal boxes with a coat of synthetic enamel paint over a coat of red oxide to steel surface to avoid rust incl suitable thick laminated sheet cover plate for mounting switch/sockets/regulator/bell push etc, concealed in wall and Cost of cutting chases & making good to distrubed surface with cement mortar, if required any shall be deemed to be included in the quoted rate
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated unsheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, ISI marked, not less than 20mm bore with conduit accessories concealed in wall, fixing with clamps on ceiling/roof etc., with pressed steel terminal boxes of suitable size & modules, concealed in walls incl plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as directed. One 5 Amps outlet point on same board with other switches/sockets NOTE: Pressed steel terminal boxes with a coat of synthetic enamel paint over a coat of red oxide to steel surface to avoid rust incl suitable thick laminated sheet cover plate for mounting switch/sockets/regulator/bell push etc, concealed in wall and Cost of cutting chases & making good to distrubed surface with cement mortar, if required any shall be deemed to be included in the quoted rate
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated unsheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, ISI marked, not less than 20mm bore with conduit accessories concealed in wall, fixing with clamps on ceiling/roof etc., with pressed steel terminal boxes of suitable size & modules, concealed in walls incl plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as directed. One 3 pin 5 Amps socket outlet on independent board. NOTE: Pressed steel terminal boxes with a coat of synthetic enamel paint over a coat of red oxide to steel surface to avoid rust incl suitable thick laminated sheet cover plate for mounting switch/sockets/regulator/bell push etc, concealed in wall and Cost of cutting chases & making good to distrubed surface with cement mortar, if required any shall be deemed to be included in the quoted rate
All as per ser item here in above but point wiring with 4.0 Sqmm FRLS cable and 4.0 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing switch piano, flush type, single pole, one way 5 Amp, 240 volt, white or ivory ISI marked ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing switch piano, flush type, single pole, one way 15 Amp, 240 volt, white or ivory ISI marked ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing switch socket outlet 5 pin, 2 in 1, 5 Amps, 240 volts ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing switch socket outlet 5 pin, 2 in 1, 5 and 15 Amps, 240 volts ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65x50 mm three terminal ; Complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down carefully existing serviceable switch piano, one way 5 Amp, 240 volt and refixing the same after rewiring ; Complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down carefully existing serviceable switch piano, one way 15 Amp, 240 volt and refixing the same after rewiring ; Complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down carefully existing serviceable socket outlet 5 Amps and refixing the same after rewiring complete all as specified
Dismantling and taking down carefully existing serviceable socket outlet 5/15 Amps and refixing the same after rewiring complete all as specified
Dismantling and taking down carefully existing serviceable fan regulator suitable for ceiling fanand refixing the same after rewiring complete all as specified
Dismantling and taking down carefully existing serviceable LED lights of any wattage or size, light fittings carrying to MES store for keeping in safe custody, refixing the same at its original location after wiring, including making electric connection from connector to light fittings & connecting up ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, double sided connection, holder including LED tube light connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose, including taking down existing unserviceable one and removing from site ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing PLUTO NEO LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Dusk & dawn roadway luminaries 35 Watt, 230 V AC, 6000K outdoor type with epoxy black powder coated sheet, high pressure die-cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete incl connecting wire with flexible PVC insulated copper cables from ceiling rose to fitting including driver, lamp bracket made of 40mm bore galvanised iron light grade pipe made to shape having overall length not exceeding 1.5 mtr, through mild steel clamp of 25mm width and four Nos. nuts, bolts & washers of 12mm dia, 100mm long fixed to wall with all other fittings ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing ceiling fan 1200mm sweep complete with blades, down rod, electronic regulator, accessories (i.e. PVC canopy, rubber bush, split pin, hanging clamp, holdfasteners etc.) 230 Volts, white colour, with min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor (BLDC) technology and connecting up with & including 3 core flexible copper conductor cable from ceiling rose to ceiling fan and writing MES No. ; Complete all as specified and directed by Engineer-in-charge.
Taking down carefully existing serviceable Ceiling fan, ceiling cable end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod after rewiring including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose or connector to fan ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Wall mounted fan of 400mm sweep plastic body and blade including pull cords for speed regulation & wide oscillation control, with 1300 RPM, 60 air delivery, 50 Watt, colour as per the direction of Engr-in-Charge ; Complete all as specified and directed by Engineer-in-charge.
Supply, install & testing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 300mm complete fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable from ceiling rose to exhaust fan and writing MES No. including cutting hole suitable for fixing exhaust fan ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing exhaust fan, heavy duty, steel body AC single Phase, 230V of size 450mm sweep, with blades and frame and louvers complete fixed to wall with suitable MS bolts, grouted to wall including connecting up with & including 3 core flexible copper conductor cable from ceiling rose to exhaust fan ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing storage electric heater (Geyser), flexible mounting of capacity 25 ltrs, single phase, 240 volts, AC, white colour, ISI marked BEE 5 star rated complete with high precision & externally adustable capillary thermostat for temp regulation, backup safety overheating capillary therrmal cut out at 95ºC, temperature display, etc., including provn of new suitable holding clamp, MS bolts, grouted to wall and connecting up including 3 core sheathed multi-stranded flexible copper conductor cable connected with 15/16 Amp plug top and provn of water connections with new PVC steel braided inlet/outlet connection pipe 15mm dia, 450mm long with two numbers brass union, NRV of suitable size, check/end nuts with washers, 15mm dia 100mm long nipples (02 Nos) for hot water and cold water connections including writing MES No. and making good to the disturbed surface in cement morter as required and testing ; Complete all as specified and directed by Engineer-in-charge. NOTE: Cost of flexible copper cable of 3 core, PVC steel braided inlet/outlet pipe of 15mm dia, 450mm long with brass union, NRV, check/end nuts, nipples, MS bolts, etc., and minor parts, if any, other than those are not specified in the schedule and required for smooth functioning of geyser will be deemed to be included in the quoted rate
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, TPN 4 way, 415 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, ; Complete all as specified and directed by Engineer-in-charge. NOTE: Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to included in the quoted rates.
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, SPN 12 way, 240 volts grade with 200 Amps insulated rated busbarwith nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, ; Complete all as specified and directed by Engineer-in-charge. NOTE: Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to included in the quoted rates.
Supply and Fixing MCB of SP 5 to 32 Amps current carrying capacity, 240V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one from the site ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCB SPN 32 Amps current carrying capacity, 240V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one from the site ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCB TP 63 Amps, current carrying capacity, 415V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one from the site ; Complete all as specified and directed by Engineer-in-charge.
Supply and FixingMCB TPN 63 Amps, current carrying capacity, 415V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one from the site ; Complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down carefully existing serviceable MCB single pole 5 to 32 Amps, 240 volt and refixing the same after rewiring ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing sub main wiring with 4 runs of 10.0 sqmm single core, multi-stranded PVC insulated, FRLS unsheathed cable 1100 Volts grade with copper conductor drawn through and including concealed non metalic PVC conduit, medium grade, ISI marked, suitable size with conduit fittings and accessories concealed in wall/ceiling/floor including 2 runs of 10.0 Sqmm multistranded PVC insulated FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly incl taking down old unsv one from site ; Complete all as specified and directed by Engineer-in-charge. NOTE: Four runs of 10.0 sqmm copper cable and two runs of 10.0 sqmm copper cable alongwith non metallic PVC conduit/conduit accessories will be measured as one unit length
All as per ser item here-in above but for sub main wiring with 2 run of 4 sqmm & 1 run of 4 sqmm as earth wire ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for loadline distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, complete incl taking down old unsv one from site ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCCB triple pole and neutral (four pole) 125 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete incl taking down old unsv one from site ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Earthing complete in replacement with galvanised iron mild steel earth plate electrode 60 cm x 60 cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth of not less than 1.5 m below normal ground level, connected to glavanised earth lead of GI wire of size 4mm dia by means of GI Bolts, Nuts, check nuts & washers and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 25mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade from top of the earth electrode raised upto a level of 50cm above ground level, MS funnel with wire mesh embeded in earthing pit of size 30x30x30cm in PCC (1:3:6) type C-1 incl exposed surfaces smoth finished with 15mm thick cement mortar (1:6), RCC pre-cast (1:2:4 type B-1) cover slab of 40mm thick with 2 Nos. MS handles of 12mm dia suitable for carrying of pit cover, Angle iron frame made out of 40x40x4mm angle iron for 30x30mm PCC pit for holding the pit cover including providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance n. exc. 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed. NOTE: (a) Cost of excavation, earth work, watering pipe, test point, MS Funnel with wire mesh and PCC pit with cover will be deemed to be included in the quoted rate. No extra cost shall be paid to the contractor against these items. (b) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor & no extra cost will be given to the contractor.
Sai Construction Co.
J S S BUILDERS & ENGINEERS
S S CONSTRUCTION COMPANY
Munish Kalia
Santokh Singh and Associates
GEE EMM ASSOCIATES
m/s. gopal krishan
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .