Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance BHOTA CHOWK HAMIRPUR H P 177001 | HAMIRPUR | HAMIRPUR | HIMACHAL PRADESH | 177001 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance DHARAMPUR | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance 00 DEHAR VPO DEHAR SUNDER NAGAR MANDI HIMACHAL PRADESH 175030 | MANDI | HIMACHAL PRADESH | 175030 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹11.9 L
EMD Value
₹24,000
Closing Date
17 Aug 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical Division HPPWD Una
Executive Engineer Electrical Division HPPWD Una
Replacement of E.I in CAL Lab for Department of Pharmacology Old MPW School in Dr RKGMC Hamirpur Distt Hamirpur H.P
2020_PWD_39373_1
PW-EDU-CB-TA-Tender-2019-20- 944-1000 Dt-21-07-202
Open Tender
Electrical Works
Item Rate
90 days
Hamirpur
Please refer tender document
6 documents required · 6 mandatory
₹500
EE Electrical
₹24,000
19 Aug 2020
29 Jul 2020
19 Aug 2020
29 Jul 2020
17 Aug 2020
29 Jul 2020
120 days
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group C.
Rewiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Supplying and fixing Computer board comprising 3 nos 5 amp switches , metal box 2 module for jack box and metal box 200 mmx150 mmx75 mm for 5 amp switchs and 5amp sockets comprising sheet cover for each 2module metal box , one no computer jack (RJ-45)with shutter including connections etc as required .
Supplying and fixing power unit 32 AMP with 4 modular G.I box .including testing and commissioningetc as required with all leads and lift.Make- Havell ( code No-AHLO322504, HSN code -8537)/anchor Roma /L&T or its equivalent as approved by Engineer-in-charge .
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-
25 mm. dia
Supplying and fixing D- link DGS-1008A 8 Port 10/100/1000M Base T-unmanaged standalone switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .Make:- D-Link,Cisco,PROLINK or its equivalent as approved by Engineer-in -charge .
Supplying and fixing D- link DGS-1024C 24 Port 10/100/1000M Base T-unmanaged standalone switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required Make:- D-Link,Cisco,PROLINK or its equivalent as approved by Engineer-in -charge .
supplying and fixing 4U wall munting rack ,3socket pdu cable manager mounting hardware 2pair mounting rail for port switch .MAKE:-Dlink,(NWR-4U-5040-GR),DGLink,CISCO or its equivalent .
Supplying and drawing Lan cable Cat -6 solid copper conductor 4 pair protected with PVC Sheathed in existing surface /recessed steel/PVC Conduit as required.Make :Polycab,Finolex ,D-link.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x1.5 Sq. mm.
2x4.0 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.
3x1.5 Sq. mm.
6x1.5 Sq. mm.
3x4.0 Sq. mm.
6x4.0 Sq. mm.
Supplying and fixing of DLP U PVC ofsize 105x50 mm adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap .Make:-Legrand ,MK ,SGI or its equivalent as required complete in all respect .
Providing, laying and fixing of drian condensate drain water pipe with all necessary fitting for alll type A.C as required complete in all respect.
Providing, laying and fixing of interconnecting copper piping with Nitrile tublar insulation AC indoor to outdoor for split type AC 1.5 ton and 1.8 AC as required complete in all respect.
Supplying and fixing 1.5 ton invertor split type air conditioner Hot and Cold, advanced filter ,E saver mode , quit mode, dual display ,auto clean ,anti bacteria filter jet Cool on/off timer sleep mode compressor cord less remote complete in all respect as per comprising to ISI with latest amendment suitable to operate on 230 volt /240 volt +_ 10 % AC supply capable to perform the function of cooling dehumidification air circulation ventilation and fitting in size of nominal cooling capacity and drain pipe 20 mm dia approximately 3mrs long 2 nos copper pipe with insulator for inlet and outlet approximatey 3 mtrs long and M.S power coated frame /stand for erection of out door unit of split type A.,C including carrigae of material with in all leads and lift.Make -Daikin (model:FTHP50/FTHT50), O Genral/Mitsubishi as approoved by the Engineer incharge..
Supplying and fixing 1 ton invertor split type air conditioner Hot and Cold, advanced filter ,E saver mode , quit mode, dual display ,auto clean ,anti bacteria filter jet Cool on/off timer sleep mode compressor cord less remote complete in all respect as per comprising to ISI with latest amendment suitable to operate on 230 volt /240 volt +_ 10 % AC supply capable to perform the function of cooling dehumidification air circulation ventilation and fitting in size of nominal cooling capacity and drain pipe 20 mm dia approximately 3mrs long 2 nos copper pipe with insulator for inlet and outlet approximatey 3 mtrs long and M.S power coated frame /stand for erection of out door unit of split type A.,C including carrigae of material with in all leads and lift.Make -Daikin (model:FTHP35/FTHT35), O Genral/Mitsubishi as approved by the Engg in charge.
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Exhaust Fan, Heavy duty, 300 mm sweep
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- Make :-Usha Technix plus ,Bajaj not less than three star model or its equivalent as approoped by the engineer in charge.
Ceiling Fan 1200 mm sweep, Category-A
Supplying and fixing surface square type LED 18 watt ,6500k (with three year warranty), and it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficiency>70 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.Make -JAQUAR (Model -LNVEO2RO18SC)/Philips/Panasonic or its equivalent as approved by Engineer-in-Charge
Supplying and fixing RECESS ROUND type LED 24 watt ,6500k (with three year warranty) it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficiency>100 Lumens per watt, CRI > 80 suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required.Make :-Jaquar (code:-LARV01R024XC ),Philips ,Tisva,wipro or its equivalent as approved by Engineer-in charge .
Providing and fixing of surface mounted Luminaire LED 25 Watt batten (with three year warranty),having high Quality design aluminium extruded decorative end caps and it should be compatible with specification i.e. Power Factor >.9,Harmonic Distortion <10% and efficiency>100Lumens per watt ,CRI> 80 suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.as required .Make :-Philips(BN021LED25S6500PSU GRS1),Tisva,Panasonic or its equivalent as approved by Engineer-in-charge.
Supplying and fixing surface mounting 1'x4' size LED(with three year warranty) solution for recess/suspended application with the use of the latest LED technology 30 watts(3000 lumens)6500 K , and it should be compatible with specification i.e Power Factor > .95,Harmonic Distortion<10% and efficiency>100 Lumens per watt suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.as required Make :-Philips (Code :-SM270C LED30 S6500PSU WH) )Panasonic ,Tisva,Jaquar or its equivalent as approved by Engineer-in-Charge.
Supplying and fixing 4 pole MCCB 63 Amp to 80Amp Ics = 100% icu, 25KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (CM91612OOJOOG),Schneider, Havell , or its equivalent as approved by Engineer-in -charge.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Make :- L& T,schinder ,ABB or it equivalent asapproved by Engineer - in - charge
Double pole. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make :- L& T,schinder ,ABB or it equivalent asapproved by Engineer - in - charge
63 Amps. Cat-A.
Supplying and fixing of SMDBs for power distribution board 4 way complince with latest standard IEC61 439 -2 DEKRA and ASTA certified rating upto 630 amp short time current with stand current 250 amp and 400 amp SMDB -36 KA ,630 amp SMDB-50 KA wth ingress protection -IP43 with INCOMING MCCB 3 pole 250 amp and outgoing MCCB 4nos 100 amp with metering, bottom cabling ,Monting base , side cbling box ,corner box 4 no phase indicating lamp,voltmeter and ammeter with 3 nos CT coil of 300/5 amp complete as required with all leads and lift . Make :- L& T,schinder ,ABB or it equivalent asapproved by Engineer - in - charge .Dimension H 787 MM, W 670 MM,D 208.5 MM
Supplying and fixing of vertical TPN DB 6 way wth up to 125 amp MCCBas incomer ready to use DB -provided with insulated vertical phase bus bar /neutral bar/with shrouds /stickining shaddle cement spill protector/colour coded interconnecting wire set/cable ties /blankinging plate and circuit indentification level with provision for 3 pole and 4 pole MCCB as incomer and SP MCBs as outgoining conformining to IS 8623-1 &3 ,IEC 61439-1&3 in CRCAsheet, RAL 9003,powder coated 6 way sheet steel MCB distribution board 415 Volt on surface/recess .Make:-L &T (Code-DBTGLO006DD ),Hegar,schinder,ABB or its eqiuivalent as per best satisfaction of Engineer-in-charge.
Supplying and fixing of vertical TPN DB 8 way wth up to 125 amp MCCBas incomer ready to use DB -provided with insulated vertical phase bus bar /neutral bar/with shrouds /stickining shaddle cement spill protector/colour coded interconnecting wire set/cable ties /blankinging plate and circuit indentification level with provision for 3 pole and 4 pole MCCB as incomer and SP/TP MCBs as outgoining conformining to IS 8623-1 &3 ,IEC 61439-1&3 in CRCAsheet, RAL 9003,powder coated 12 way sheet steel MCB distribution board 415 Volt on surface/recess .Make:-L &T (Code-DBPGLOO8DD),Hegar,schinder,ABB or its eqiuivalent as per best satisfaction of Engineer-in-charge.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-4 way
Double door-8 way
Double door-16 way
Supplying and fixing earthing system as per COPPER PIPE 2 meter long and cpper strip 2 meter long size 40 x 6x450 mm with 25 Kg compound including exvation of pit and refiling the same and making earth chamber 320 mm x320 mm x196 mm chamber with cover as required complete in all respect. make :-Earth plus (Cat NO- SMI-250-C-4500),True power,Ashloka or its equivalent as per best satisfaction of Engineer-in -charge.
Providing and fixing 25mm x 5mm copper strip in 40 mm dia. G.I. pipe from earth electrode etc. as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required.
Providing and laying earth connections from earth electrode with 6 SWG (4 mm dia.) copper Wire in 15 mm dia. G.I. pipe from earth electrode etc. as required.
Supplying and fixing of cable end box double door 16 way in CRCA steel RAL 9003 powder coated can be either fitted at top or bottom of distribution board .Make:-L&T(cat No DBSPN016C)Havell/schinder or its equivalent asapprovedby Engineer-in -charge .
Supplying and fixing of cable end box double door 8way in CRCA steel RAL 9003 powder coated can be either fitted at top or bottom of distribution board .Make:-L&T(cat No DBSPN008CB)Havell/schinder or its equivalent asapprovedby Engineer-in -charge .
Supplying and fixing of cable end box for phase vertical TPN DB 6 WAY , in CRCA steel RAL 9003 powder coated can be either fitted at top or bottom of distribution board .Make:-L&T (CAT NO- DBPSG006CB)/Havell/schinder or its equivalent asapprovedby Engineer-in -charge.
Supplying and fixing of cable end box for phase vertical TPN DB 8 WAY , in CRCA steel RAL 9003 powder coated can be either fitted at top or bottom of distribution board .Make:-L&T (CAT NO- DBPSG008CB)/Havell/schinder or its equivalent asapprovedby Engineer-in -charge.
Supplying and fixing exhaust fan lower and shutter for 300/380mm eshoust fan on the existing wall painting with ply board etc. as required.
Supplying and fixing 7.5 KVA on line UPS with 30 minute back up on SMF batteries .7.5 KVA true on line pure sine wave DSP controlled on line UPS with IGBT based technology with inbuilt isolation transformer having 200 VDC with SMF batteries bank and accesories (20 no of 26/28 AH batteries ) with three year warranty on UPS and batteries .Make APC/Emerson/Numeric as approoved by the Engineer incharge.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 35 sq. mm (3.5 core)
Suppling and fixing rubber mat 1x2 mtr long 12 mm thick in the front main panel etc as required including carriage of material all leads and lifts
S/F and fixing shock treatment chart in main panel room on the exiting wall etc as required as approved Engineer-in -charge .
HAMIR ELECTRICAL
Dhiman Elect-
Rajesh Kumar Jaswal
ARUN KUMAR SHARMA
stage.html
html • 0.03 MB
finance_58139.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .