Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.7 L+₹71,149.90 (2.97%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹26.8 L+₹2.9 L (11.9%)Rejected-Finance 70 SUBHASH ROAD HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹27.5 L+₹3.5 L (14.7%)Rejected-Finance NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹27.6 L+₹3.6 L (14.9%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L5 | Rejected-Finance Being L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
6 Jan 2024, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/REPLACEMENT AND MAINT OF LT PANEL OF VARIOUS CAPACITIES AND OTHER MISC WORKS AT DIFFERENT PUMP HOUSE IN THE AREA OF AGE E/M EXT(W/S) UNDER GE E/M LUCKNOW
2023_MES_623061_2
GE/EM/LKO/EXT(WS)/T-47 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹70,000
Yes
29 Jan 2024
14 Dec 2023
8 Jan 2024
14 Dec 2023
6 Jan 2024
21 Dec 2023
Amount
Dismantling and taking out faulty analog type Ammeter from LT panel and supply and fixing three phase Ammeter digital type upto 0 to 100 Amps with suitable CT's ratio of size 96 mm x 96 mm of any range as required at site including necessary control wire connection and testing complete all as specified and directed.
Dismantling and taking out faulty analog type voltmeter from LT panel /feeder pillar box and S&F three phase power voltmeter digital type suitable for ( 0-500 volts) range, size 96mmx96mm size including necessary control wire connection and testing complete all as specified and directed.
Supply and fix in repairs MCCB 160 Amps, 415 volts AC 50Hz, 3 pole, bracking capacity 36 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified.
Supply and fixed in repairs MCCB 100 Amps, 415 volts AC 50Hz, 3 pole, bracking capacity 16 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified.
Supply & fix in repairs electronic control timer type ET-100 of suitable capacity as required at site.
Supplying, laying or fixing, in repairs, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 70 sqmm cross sectional area, 3.5 core, complete all as specified laid in trenches / laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items.
All as per item here in above but size of 50 sqmm 3.5 core.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm using excavated suitable soil complete all as specified.
Removing excavated soil not exc 50 m and depositing where directed at a level not exc .5m above the starting point complete all as specified and directed by Engr-in-charge.
M&L for providing dry river sand as in sand cushioning to under ground cable of any descreption including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose any punned thickness of sand will be considered.)
M&L for laying well burnt old size bricks, sub class "B" bricks, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
Supply, installation, testing and commissioning indoor type LT cubical panel size not less than 1.5 Mtrx 1.2 Mtr x 0.40Mtr depth shall be factory fabricated as per IS-375 powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 2.00 mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators size not less than 50x50x conical type at a maximum interval of 500mm ). The incomer and outgoing shall have extension link two times the rating of individual feeder. The length of extension should not be less than 200mm long copper strip. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs.
INCOMING
a) Changeover switch on load in open execution 4 pole 415 V, 50 cycles-160 Amp -02 Nos( One for commercial & DG Set Supply & other for phase changing.
b) Busbar 4 pole (three phase and one for neutral) made out of laminated copper size 40mmx6mm
c) MCCB Cap 160 Amp, 4 pole, 415V, 50 c/s 36 KA-01 No.
OUTGOING
a) MCCB Cap 100 Amp, 4 pole, 415V, 50 c/s 36 KA-01 No.
b)MCB TPN capacity 32 Amps, 415V, 50 c/s 16 KA-01 No.
c) MCB SPN capacity 32 amp, 'C' series-02 Nos.
d) Star delta soft starter suitable for 36 KW / 50HP 3 phase, 415V, 50 c/s induction motor including protection against over voltage, under voltage, over current under current reverse phasing, single phasing, earth fault with required PLC.
e) DOL starter suitable for 3 phase 50 Hz 400V, not less than 5 HP induction motor.-01 No.
METERING & MISC
e) Set of indicating lamp LED type-01 Set.
f) Civil work PCC 1:2:4 for grouting of panel complete including excavation, earth work.
g) Disconnecting of existing LT UG cable from old panel and connecting in new panel including connected work.
h) Digital Multi function meter for Ammeter, Volt, KWH, PF, frequency etc 3 phase 4 wire of suitable capacity.-01 No.
Supply, installation, testing & commissioning electrically connected feeder pillar outdoor type single door compartmenttized with locking arrangements canopy at top weather proof vermin/dust proof of suitable size cubical type factory made of CRCA MS Sheet 3.15mm thick machine pressed of size 60x60x40cm & angle iron frame 40x40x6mm for legs & incl grouted in PCC 1:2:4 type B1 (using 20mm graded stone aggregate) suitable 440 volts, AC, 3 phase, 4 wire busbar 4 pole made out of suitable size copper strip capacity 200 Amps fully mounted on procelain insulator enclosed chamber with openable shutter both sides complete all as specified & directed
M&L for earthing complete for electrical equipments with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to earth lead of GI strip of size 32x6mm by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soilcomplete all other accessories as shown on electrical plate No 3 of MES SSR Part I including 40mm bore light grade GI pipe 1.8 mtr length with top end covered with plug or cap for watering and 30x30x30cm size PCC 1:3:6 block around watering pipe, excluding 20mm dia watering pipe, PCC, watering pit, funnel, pit cover complete all as specified and directed by Engr-in-charge.
S&F in repair LED aviation obstruction Light fitting, double dome type, 2 x 5 Watt 230 Volts 50 Hz, yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories fixed over O/H Tank at height 21 Mtrs to 26 mtrs.
S&F in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240V,of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete without MCB and with enclosure blank plates for unused way suitable for 02 way complete all as specified and directed by Engr-in-charge.
S&F in repair MCB single pole & neutral 20 Amp rating 'C' Series 240 Volt complete all as specified and directed by Engr-in-charge.
S&F PVC insulated & PVC sheathed, heavy duty electric cable with Copper conductor, multi stranded 1100 volts grade round, 3 core, 1.5 Sqmm fixed on RCC Piller / Dome of over head tank at hight of 26 meter approximatelly from normal ground level incluiding fixing arrangement and taking out of existing unserviceable cable complete all as specified and directed by Engr-in-charge.
S&F cable joint kit suitable for 0.5 Sqmm 10 pairs of copper wire cable of water level indicator complete all as specified and directed.
Supplying, laying or fixing, jointing and testing solid PVC insulated , 10 pairs, individual shielded for interference rejection, armoured PVC sheathed 1100 Volts garde 0.5 sqmm instruemental cable ISI-5608 marked , complete all as specified laid in trenches / laid under floor or fixed naked on walls / on poles/ in ducts / in GI pipes etc. including taking out unserviceable cable complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items.
Supply and fix in repair wall / surface mounting luminaires integrated LED Batten (4 feet) 20 W, 6500 K, 230V , system efficiency not less than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge.
Taking down carefully aluminum point wiring complete of any type (batten / surface conduit for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces complete all as specified and directed.
Material & Labour for point wiring for one light / Fan point / bell point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including 20 mm dia heavy duety PVC conduite including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick all as specified and directed by Engineer-in-Charge.
All as per item No 24 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch.
All as per item No 24 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch.
All as per item No 24 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
S&F switch piano flush type, single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F switch piano flush type, single pole, one way 15 /16 Amps, 240 Volts complete all as specified and as directed.
S&F socket outlet flush type multipurpose 2 in 1, 5 pin 6 Amp, 230 volts complete as directed.
S&F socket outlet, 2 in 1, 3 / 5 pin, 6 / 16 Amp, piano flush type complete all as specified and as directed
Supply & fix step type fan regulator 120 Watt, 240 Volt AC, flush type complete all as specified and directed.
S&F ceiling rose, surface type polycarbonate body, 65mm x 17 mm, three terminals complete all as specified and as directed.
Sanjai sales and services
M/S SHIVA CONSTRUCTION
NEXT POWER ENTERPRISES
M/S S.B. Singh and Sons
Eco Creations
SAKSHAM SUPPLIERS BUILDERS
Unnati Engineers
OM NAMAH SHIVAY ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .