Directorate of Municipal Administration
S N Ganachari
conversion of LT overhead line to underground cable from unkal cross to sai nagar cross of ward no 37 and 38 of hubballi division.
DMA/2024-25/EL/WORK_INDENT22874
DMA/2024-25/EL/WORK_INDENT22874
Open
Electrical
Two Tender Document System(Two Cover)
DMA City Corporation Hubballi-Dharawada
16 documents required · 16 mandatory
Work Done Certificates for the Work performed as Prime Contractor (in the same name) on works of similar nature over during the five years specified (Similar nature of Work done certificate 50 percent of amount put to tender) Each tenderer in its name should have in the last five years from 2019-20 to 2023-24 Satisfactory completed at least one similar Retaining wall work of value not less than Rs.91.93 Lakhs as prime contractor
Valid appropriate Class 1 and above license certificate issued by Electrical Inspectorate.
The Work Done Certificates for the Quantities of work executed as prime contractor (in the same name) during the last five years specified along with the details in the format as in the bid document.Executed in any one year in the last five years from 2019-20 to 2023-24 the following minimum quantities of work CABLE 95 Sq.mm and above 5.6km.Feeder piller box 14 no.
List of existing commitments and ongoing works
List of works for which tenders already submitted
The Work Done Certificates for the Quantities of work executed as prime contractor (in the same name) during the last five years specified along with the details in the format as in the bid document
Financial Turnover certificate obtained and certified by the Registered Valid Chartered Accountant indicating the Registration no of chartered accountant with UDIN Number Details. Tenderer in his name should have in the last five years from 2019-20 to 2023-24 achieved in at least two financial years minimum annual financial turnover (in all classes of civil engineering construction works only) of Rs 367.72Lakhs.
Line of Credit 30 percent of amount put to tender obtained from Nationalized / Scheduled Banks in Given Pro forma in the bid document Liquid assets and or availability of credit facilities of not less than Rs.55.16Lakhs Line of Credit
profit and loss statement in the name of the participating bidder
ITR Returns filed Copy in the name of the participating bidder
balance sheet tallying the Annual Turn Over during the previous five years in the name of the participating bidder
Self Attestation regarding Agreed to Terms and Conditions as per (bid document) kw4 on face value of Stamp Paper Rs 20 engineering works executed and payments received in the last five years (year-wise)
Valid GST Registration Certificate
Declaration that the bidder has not been blacklisted on Stamp paper of Face Value Rs 20
Valid PAN Card of the Participating Bidder
Signed Copy by the Participating Agency on the Letter head containing the Address and Contact Details indication Contact Person & Designation, Contact Number Office Landline / Mobile, and valid email ID.
₹3,900
₹2.8 L
4 Aug 2024
4 Aug 2024
20 Aug 2024
12 Aug 2024
7 Aug 2024
conversion of LT overhead line to underground cable from unkal cross to sai nagar cross of ward no 37 and 38 of hubballi division.
Spun Pole Pre-Stressed Tubular Spun Pole - 11 Mtr Long, 500 Kg WL (Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158: 1991
Erection Of Spun Pole Erection of 11 Mtr long Concrete Spun Pole in a pit of 2.5 Mtr depth (Mechnised Labour)
Three H Frame Three H Frame with Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole up to and including 250 kVA (UG Cable) - MS
Fixing Three H Frame For Three H Frame with Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole up to and including 250 kVA (UG Cable) (excluding erection of Pole)
11 kV, Horizontal Cross Arm - Mild Steel (MS) page no 3
Fixing of HT/LT Single Top Support
11 kV, 5 kN Composite Polymeric Pin Insulator (24 mm dia FRP Rod)
Rabbit ACSR Conductor
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM ESCOMs
Stringing of Conductor do - for Rabbit ACSR
Alkathine Tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr
Base concreting For 11 M Spun Pole (1000x1000x150 mm)
Pole concreting For 11 M Spun Pole (1000x1000x2500 mm)
Coping for Poles 390 mm all around the pole for an height of 300 mm for Spun Pole(1130x1130x300 mm)
(3.251 mm Dia), Std Wt: 82 Kg/KM
7/10 SWG GI Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM
GI Pipe Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, ...
Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary
Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint...
Pipe Grounding GI grounding Pipe,B-class,42mm dia,2.5mtr long 3.2mm thick with bolt,nut,GI strips and washer compleete.Minimum weight of GI pipe:7.3kg.
Good Quality well burnt charcoal for grounding purposes packed in non returnable gunny bag of 30 kg each .
Good Quality salt for grounding purposes packed in 50kg gunny bag .
Digging of pit for providing GI Pipe type Earthing.
Caution/Danger Board
Fixing Danger Board
GI Barbed wire (12 Mtr/Kg) wire
Fixing ChargesGI Barbed wire
11 kV, Horizontal Cross Arm - Mild Steel (MS)
Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace
and Insulator fixing
PVC Insulation Tapes 19 mm wide and in rolls of 10 Mtr
11 kV, HG Fuse Unit with Solid Core Insulator
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring
11 kV, 200 Amps Single Break GOS
Fixing of GOS including wiring (11 kV Single Break 200 Amps)
H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - MS
Erection of H-Frame.
LT Distribution Box for 250 kVA DTC with MCCB's
Fixing LT Distribution box for 100/250/500 kVA DTC (Excluding wiring)
PVC Wire -240 Sqmm
Al Wt: 63.5 Kg, Total Wt: 87 Kg/100 Mtr Coil
Heavy Duty Copper Terminal Long Barrel 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm
PG Clamp Rabbit to Insulated Wire 240 Sqmm
LT Line Spacer For TC Wiring
For Distribution Transformer Centre (DTC) MS Box for housing the ETV Meter 3 Phase 4 Wire 5 Amps, with associated LT CT 0.5 Accuracy Class, ring type, with wiring Clamps, B&N and all other accessories...
Fixing LT Distribution box for 100/250/500 kVA DTC (Excluding wiring)
LT 3 Phase, 4 Wire, CT Operated DLMS Complaint ETV Meter-5A, class 0.5s Accuracy (Used for 25 HP/18KW & Above Installations, DTC Metering)
Fixing of LT Metering Box with clamping arrangement for mounting on the Transformer structure with necessary terminal strip and CT mounting arrangement for housing the ETV Meters and connecting to the...
10 kV, 5 kA Lightning Arrester Polymeric type with GROUND DISCONNECTOR
11 kV Lightning Arrester, Metal oxide,10 kV, 5 kA Polymeric Type with ground disconnector
11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 400 Sqmm, (51 GI Wires - 4 mm Dia)
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 3x300 to 3x500 Sqmm
Heat Shrinkable Straight Through Jointing Kit for
XLPE Cable with Copper Lug & Al Ferrule 3x400 Sqmm
cable Joint and wiring Heat shrinkable Straight Through Joint 3x300 to 3x400 Sqmm
UG Cable Termination Kit Heat Shrinkable Indoor Type Cable Termination Kit
for XLPE Cable 3x400 Sqmm
Making and Fixing pot head for HT Cable only Heat shrinkable Type Terminations 3x300 to 3x400 Sqmm
11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95sqmm ESCOMs SR 2023-24 Page No 351
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 3x300 to 3x500 Sqmm
Heat Shrinkable Straight Through Jointing Kit for
XLPE Cable with Copper Lug & Al Ferrule 3x95 Sqmm
cable Joint and wiring Heat shrinkable Straight Through Joint 3x95 to 3x150 Sqmm
Heat Shrinkable Indoor Type Cable Termination Kit
for XLPE Cable 3x95 Sqmm
Making and Fixing pot head for HT Cable only Heat shrinkable Type Terminations 3x95 to 3x150 Sqmm
1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975 240 ...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 to 240 Sqmm
Heat Shrinkable Straight Through Jointing Kit for XLPE Cable with Copper Lug & Al Ferrule 3x240 Sqmm
Heat shrinkable Straight Through Joint 3x185 to 3x240 Sqmm
LT Feeder Piller Box with Poreclain
Rewireable Cutout and & 1 No of 630 Amps
Load Break Switch with Copper Busbar as
per IS-13947 Part-1&2 12 Way
Fixing LT Feeder piller box (MS & Thermoset Plastic Enclosure) including necessary civil works like soil excavation & concreting etc. complete above 8 Ways (MS Enclosure)
Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment
Cable Covering Tile 125x250x40 mm
Joining with mud mortor complete Covering cable with Tiles
Sand Artificial/Manufacture Sand
Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. (Does not include cost of sand)
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm,...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm,...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm,...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 95 Sqmm,...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 Sqmm
HDPE/PLB Pipe 50/42 mm
RCC Hume Pipe 2000 mm long 150 mm Dia
Laying RCC Hume Pipe and Jointing the pipes (100-150 mm Dia) including lowering in Position: Fixing Collars etc., Joining with mud mortor complete
Collars for RCC Hume Pipe 150 mm Dia
Gi Pipe 100 MM Dia GI Heavy Duty pipes 100mm dia
Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.
Route & Joint indicating slab with MS Anchor rod
Fixing of Route Joint Indicating Slab
Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricadin...
Refilling available earth around trenches pipelines, cables in layers not exceeding 20 cm in depth compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5m....
Releasing RCC/PSC Pole 9 Mtrs, 8 Mtrs Dismanting of Steel/I- Beam
Releasing of 2 Pin cross arm with Insulator and Braces fixing
Releasing of 4 Pin cross arm with Insulator and Braces fixing
Releasing of V-Shape/Horizontal cross arm including Single Top Support Brace
and Insulator fixing
Releasing of Conductor Weasel/Rabbit
Releasing GOS Fixing of GOS including wiring (11 kV Single Break 200 Amps)
Releasing of H-Frame for mounting GOS
Releasing LT Distribution box for 100/250/500 kVA DTC (Excluding wiring)
Releasing 1 Circuit of LT Wiring for 250/500 kVA Transformers via metering box.
(includes fixing of necessary supports like 2 Pin cross arm, Spacer etc)
Releasing Wiring of 1 Circuit of LT Wiring for for 25/63/100 kVA DTC to the existing LT protection Kit/ Distribution Box via metering box. (includes fixing of necessary supports like 2 Pin cross arm, ...
Releasing 9 Mtrs RCC Transformer Structure DP 100 KVA 3.01
Releasing 9 Mtrs RCC Transformer Structure DP for 100-250KVA 3.02
LT Feeder Piller Box with Poreclain
Rewireable Cutout and & 1 No of 630 Amps
Load Break Switch with Copper Busbar as
per IS-13947 Part1&2 8Way
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
kw4 final1 -INDENT22874.docx
Tender Document • 1.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .