Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 CrAccepted-AOC | ₹12.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹12.9 CrRejected-Finance | ₹12.9 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹14.0 CrRejected-Finance CANADA BUILDING 224 DR D N ROAD MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹14.0 Cr | L3 | Rejected-Finance L3 |
Tender Value
₹14.8 Cr
EMD Value
₹29.5 L
Closing Date
10 Jun 2022, 5:00 pmClosed
Executive Engineer Elect. Divn. PWD B and R Hisar
Executive Engineer Elect. Divn. PWD B and R Hisar
CONSTRUCTION OF RUNWAY, TAXIWAYS AND APRONS AT HISAR AIRPORT (PDG. CAT-2 APPROACH LIGHTING SYSTEM).
2022_HRY_219047_1
Elect-GGN/Elect-HSR/100316
Open Tender
Electrical Works
120 days
Hisar
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,000
₹29.5 L
Hisar
30 Jul 2022
2 May 2022
13 Jun 2022
2 May 2022
10 Jun 2022
2 May 2022
12 May 2022
Amount
Subhead I Supply items:- Supply of Inset type fittings suitable for Bi directional, High Intensity Runway CENTRE LINE lighting for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with 2 x 45/48 Watts, 6.6 amps pre-focused reflector halogen lamp of 6.6 amps current with connected heat resistant accessories, prism assesembly, optical assembly, "0" ring seal, pressure relief test plug, hardware, lenses and all standard accessories complete and ready for site installation as required and as per the enclosed specifications. clear / clear lenses (FAA/ICAO compliance)
Subhead I Supply items:- Supply of Inset type fittings suitable for Bi directional,High Intensity Runway CENTRE LINE lighting for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with 2 x 45/48 Watts, 6.6 amps pre-focused reflector halogen lamp of 6.6 amps current with connected heat resistant accessories, prism assesembly, optical assembly, "0" ring seal, pressure relief test plug, hardware, lenses and all standard accessories complete and ready for site installation as required and as per the enclosed specifications. clear / red lenses (FAA/ICAO compliance)
Subhead I Supply items:- Supply of inset type fittings suitable for uni directional. High intensity touch down zone (TDZ) lighting for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with 1 x 45/48 watts, 6.6 amps pre-focused reflector halogem lamp of 6.6 amps current with connected heat resistant accessories, prism assesembly, optical assembly, "O" ring seal, pressure relief test plug, hardware, clear/ yellow lenses and all standard accessories and ready for site installation as required and as per the enclosed specifications. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of inset type fittings suitable for uni directional, high intensity approach lighting for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with 3 x 105 watts, 6.6 amps pre-focused reflector halogen lamp of 6.6 amps current with connented heat resistant accessories, prism assesembly, optical assembly, "O" ring seal, pressure relief test plug, hardware, clear/yellow lenses and all standard accessories and ready for site installation as required and as per the enclosed particular specifications. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of inset type fittings suitable for uni directional, high intensity side row approach lighting for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with 3x 105 watts, 6.6 amps pre focused reflector halogen lamp of 6.6 amps current with connected heat resistant accessories, prism assesembly, optical assembly, "O" ring seal, pressure relief test plug, hardware, clear/yellow lenses and all standard accessories and ready for site installation as required and as per the enclosede specifications. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of inset type fittings unidirectional, suitable for high intensity runway threshold lighting for aviation visual aids requirements and outer cover made of die cast aluminium complete with 2 x 105 watts, 6.6 amps pre focused reflector halogen lamp of 6.6 amps current with connected heat resistant accessories, prism assesembly, optical assembly, "0" ring seal, pressure relief test plug, hardware, green prism / lenses and all standard accessories and ready for site installation as required and as per the enclosed specifications. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of inset type fittings, bi-directional, suitable for High instensity Runway END lighting for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner bosy and outer cover made of die cast aluminium complete with and outer cover made of die cast aluminium complete with 1 x 105 Watts,6.6 amps pre focused reflector halogen lamp of 6.6 amps current with connected heat resistant accessories, prism assesembly, optical assembly, "0" ring seal, pressure relief test plug, hardware, green prism / lenses and all standard accessories and ready for site installation as required and as per the enclosed specifications. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of Bi-directional Inset type High Intensity Runway Edge light fitting for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with 2 x 105 Watts, 6.6 amps pre-focused reflector halogen lamp of 6.6 amps current with connected heat resistant accessories, prism assesembly, optical assembly, "0" ring seal, pressure relief test plug, hardware, clear / yellow lenses and all standard accessories and ready for site Installation as required and as per the enclosed specifications, clear /clear lenses (FAA/ICAO compliance)
Subhead I Supply items:- Supply of Bi-directional Inset type High Intensity Runway Edge light fitting for aviation visual aids requirements complete with shallow base and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with 2 x 105 Watts, 6.6 amps pre-focused reflector halogen lamp of 6.6 amps current with connected heat resistant accessories, prism assesembly, optical assembly, "0" ring seal, pressure relief test plug, hardware, clear / yellow lenses and all standard accessories and ready for site installation as required and as per the enclosed specifications. clear / yellow (Amber) lenses. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of inset type Uni directional STOP BAR light fixture with 40/48 W halogen reflector lamp,red interference filter, with shallow base and matching body of the fitting, inner body and outer cover made of die cast aluminium complete with pre-focused reflector halogen lamp of 6.6 amps current with connected heat resistant accessories, prism assesembly, optical assembly, "0" ring seal, pressure relief test plug. hardware, lense and all standard accessories and ready for site installation as required and as per the enclosed part icular specifications. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of LED type elevated MIRL fittings suitable for Turning Pad lighting/Taxi edge lighting/ Apron edge lighting use with complete with lens support mechanism, prefocus lamp holder, lens clamping mechanism, central column assembly, breakable coupling , gasket, two pin secondry base plate with 6 nos. M-10 stainless steel bolts, spring washer and other accessories with Omni directional Blue lens, 7.5 watt or of suitable for watts, 6.6 Amps etc. and confirming to ICAO requirements and as per , the enclosed specification. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of Uni-directional threshold wingbar light fittings elevated type fixed focus High Intensity complete with prefocus lamp holder, lens/spreader glass, lens holding mechanism, reflector assembly elevation & horizontal adjustment mechanism, breakable coupling, mounting assembly, gaskets and two pin secondary lead plug 2.5 Sq.mm. suitable for connection with isolating transformer, base plate with 6 Each stainless steel bolts, spring and plain washers and with 200Watts, 6.6 amps, halogen lamps and confirming to particular specifications enclosed. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of Uni-directional approach light fittings elevated type fixed focus High Intensity complete with prefocus lamp holder, lens/spreader glass, lens holding mechanism, reflector assembly elevation & horizontal adjustment mechanism, breakable coupling, mounting assembly, gaskets and two pin secondary lead plug 2.5 Sq.mm. suitable for connection with isolating transformer, base plate with 6 Each stainless steel bolts, spring and plain washers and with 200Watts, 6.6 amps, halogen lamps and confirming to particular specifications enclosed. (FAA/ICAO compliance)
Subhead I Supply items:- Supply of elevated type high intensity runway light fitting suitable for Runway edge lights use with Halogen lamp, complete with lens support mechanism, prefocus lamp holder, lens clamping mechanism, central column assembly, breakable coupling, gaskets and two pin secondary lead, base plate with 6 Each M-10 stainless steel bolts, spring and plain washers and other accessories with outer dome glass and 2 x 180 degree CLEAR/YELLOW/RED inner lens/filter, 150 Watts, 6.6 amps, halogen lamps etc., complete as required and confirming to ICAO requirements and particular specifications enclosed. a) Clear/clear (FAA/ICAO compliance)
Clear/Yellow
Subhead I Supply items:- Supply, Installation, Testing & commissioning of PAPI (SET OF 4 ) with associated hardware and calibration kit (clinometer & checking stick), foundation, grouding etc etc, compliant to ICAO Annex 14 &complete as required. (FAA/ICAO compliance)
Subhead I Supply items:- Supply, Installation, Testing & commissioning of ROTATING BEACON with associated lamps, hardware foundation grouding etc , compliant to ICAO Annex 14 complete as required. (FAA/ICAO compliance)
Subhead I Supply items:- Supply, Installation, Testing & commissioning of Landing 'H' indicator with associated LED fittings, hardware etc , compliant to ICAO Annex 14 complete as required. (FAA/ICAO compliance)
Subhead I Supply items:- Supply, Installation, Testing & commissioning of illuminated Wind direaction Indicator (WDI) with associated lamps, hardware foundation, grouding etc and compliant to FAA/ ICAO Annex 14 complete as required.
Subhead I Supply items:- SITC of LED type Elevated Runway Guard light which includes two set of flashing light fixture installed at both side of taxiway with black independent visors, 6.6A current driven input power supply, two lamps 150 W -6.6 A, flashinbg rates 45-50 per mintues, frangible support, high strength base plate for runway guard light two resist wind speed (300 mph). complete as required. (2 set for each runway/taxiway intersection)
Subhead I Supply items:- Supply of Indoor type air cooled constant current regulator of micro processor controlled, thyristor type suitable for operation on 230 Volts +/-10%, 50 Hz input AC supply with 5 steps variation of current output( 6.6, 5.2, 4.1, 3.4 and 2.8 Amp) and able to communicate with PC or PLC controlled system, with digital output ammeter(0-10 Amps), over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, LCD display, complete as required for the following rating and conforming to specifications enclosed. 2.5 KW CCR
Subhead I Supply items:- Supply of Indoor type air cooled constant current regulator of micro processor controlled, thyristor type suitable for operation on 230 Volts + 10%, 50 Hz input AC supply with 5 steps variation of current output( 6.6, 5.2, 4.1, 3.4 and 2.8 Amp) and able to communicate with PC or PLC controlled system, with digital output ammeter(0-10 Amps), over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, LCD display, complete as required for the following rating and conforming to specifications enclosed. 4 KW CCR
Subhead I Supply items:- Supply of Indoor type air cooled constant current regulator of micro processor controlled, thyristor type suitable for operation on 230 Volts + 10%, 50 Hz input AC supply with 5 steps variation of current output( 6.6, 5.2, 4.1, 3.4 and 2.8 Amp) and able to communicate with PC or PLC controlled system, with digital output ammeter(0-10 Amps), over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, LCD display, complete as required for the following rating and conforming to specifications enclosed. 7.5 KW CCR.
Subhead I Supply items:- Supply of Indoor type air cooled constant current regulator of micro processor controlled, thyristor type suitable for operation on 415 Volts +/-10%, 50 Hz input AC supply with 5 steps variation of current output( 6.6, 5.2, 4.1, 3.4 and 2.8 Amp) and able to communicate with PC or PLC controlled system, with digital output ammeter(0-10 Amps), over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, LCD display, complete as required for the following rating and conforming to specifications enclosed. 15 kW CCR
Subhead I Supply items:- Supply of Indoor type air cooled constant current regualator of micro processor controlled, thyristor type suitable for operation on 415 Volts +/- 10%, 50 Hz input AC supply with 5 steps variation of current output( 6.6, 5.2, 4.1, 3.4 and 2.8 Amp) and able to communicate with PC or PLC controlled system, with digital output ammeter(0-10 Amps), over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, LCD display, complete as required for the following rating and conforming to specifications enclosed. 20 KW CCR
Subhead I Supply items:- Supply of Indoor type air cooled constant current regulator of micro processor controlled, thyristor type suitable for operation on 415 Volts +/- 10%, 50 Hz input AC supply with 5 steps variation of current output (20,15.8,12.4,10.3,8.5 Amp) and able to communicate with PC or PLC controlled system, with digital output ammeter(0-10 Amps), over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, LCD display, complete as required for the following rating and conforming to specifications enclosed. 30 KW CCR
Subhead I Supply items:- Supply of 5 KV grade, 16 sqmm single core copper conductor XLPE insulated, PVC sheathed, AFL cable as specified in technical specifications complete as required.
Subhead I Supply items:- Supply of 5 KV grade, 6 sqmm single core copper conductor XLPE insulated, PVC sheathed , AFL cable, as specified in techincal specifications complete as required.
Subhead I Supply items:- Supply of 12 pairs Fibre Optic RC cable for laying from CCR hall to ATC Tower.
Subhead I Supply items:- Supply of 2 x 4 sqmm secondary lead made out of multi stranded annealed copper conductor EPR insulated & PCP sheathed, 1.1 KV grade underground cable as specified in techincal specification complete as required.
Subhead I Supply items:- Supply of 2 x 4 sqmm, 600 V grage plug & receptacle of type II, class 'B' connector and suitable field attachment for EPR insulated, PCP sheathed, two core copper conductor secondary cable as required.
Subhead I Supply items:- Supply of 6 sqmm size 5 KV grade plug and receptacle of type I, class 'B' connector and suitable field attachment with 5 KV grade PVC insulated, PVC sheathed, single core copper conductor cable as required and confirming to the specifications.
Subhead I Supply items:- Supply of 16 sqmm size 5 KV grade plug and receptacle of type I, class B' connector and suitable field attachment with 5 KV grade PVC insulated, PVC sheathed, single core copper conductor cable as required and confirming to the specifications.
Subhead I Supply items:- Supply of 3.5C x 300 Sq.mm 1.1 KV grade cable XLPE insulated, PVC sheathed, armoured alunimum conductor cable conforming to IS 7098 (Part 1) amended upto date.
Subhead I Supply items:- Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured alunimum conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5 x 35 sqmm
3.5 x 70 sqmm
4 x 16 sqmm
Subhead I Supply items:- Supply of following rating 5 KV grade, 50 Hz series isolating transformers encapsulated in polyster resin, finally moulded in neoprene type rubber and with primary and secondry connections confirming to specification as required suitable for above mentioned fittings for following applications. 15 watt, 6.6A/6.6A
Subhead I Supply items:- Supply of following rating 5 KV grade, 50 Hz series isolating transformers encapsulated in polyster resin, finally moulded in neoprene type rubber and with primary and secondry connections confirming to specification as required suitable for above mentioned fittings for following applications. 15 watt, 20A/6.6A
Subhead I Supply items:- Supply of following rating 5 KV grade, 50 Hz series isolating transformers encapsulated in polyster resin, finally moulded in neoprene type rubber and with primary and secondry connections confirming to specification as required suitable for above mentioned fittings for following applications. 45 watt, 6.6A/6.6A
Subhead I Supply items:- Supply of following rating 5 KV grade, 50 Hz series isolating transformers encapsulated in polyster resin, finally moulded in neoprene type rubber and with primary and secondry connections confirming to specificatior as required suitable for above mentioned fittings for following applications. 65 watt, 6.6A/6.6A
Subhead I Supply items:- Supply of following rating 5 KV grade, 50 Hz series isolating transformers encapsulated in polyster resin, finally moulded in neoprene type rubber and with primary and secondry connections confirming to specification as required suitable for above mentioned fittings for following applications. 100 watt, 6.6A/6.6A
Subhead I Supply items:- Supply of following rating 5 KV grade, 50 Hz series isolating transformers encapsulated in polyster resin, finally moulded in neoprene type rubber T and with primary and secondry connections confirming to specification R as required suitable for above mentioned fittings for following applications. 150 watt, 6.6A/6.6A
Subhead I Supply items:- Supply of following rating 5 KV grade, 50 Hz series isolating transformers encapsulated in polyster resin, finally moulded in neoprene type rubber and with primary and secondry connections confirming to specification as required suitable for above mentioned fittings for following applications. 200 watt, 6.6A/6.6A
Subhead I Supply items:- Supply of following rating 5 KV grade, 50 Hz series isolating transformers encapsulated in polyster resin, finally moulded in neoprene type rubber and with primary and secondry connections confirming to specification as required suitable for above mentioned fittings for following applications. 200 watt, 20A/6.6A
Subhead I Supply items:- Supply of following rating 5 KV grade, 50 Hz series isolating transformers encapsulated in polyster resin, finally moulded in neoprene type rubber and with primary and secondry connections confirming to specification as required suitable for above mentioned fittings for following applications. 300 watt, 6.6A/6.6A
Subhead I Supply items:- Supply of Cast iron Isolating Transformer housing box, water tight round type, metal container of outside dia 330 mm, height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having three/two/one nos holes as per site requirement on the periphery centre, 75 mm above bottom surface suitable to receive 50 mm HDPE pipes as required. The box should have two SS earth bolts of M10 x 40 mm tapped inside near the hole (4" away from the hole centre) and having a drain hole at the bottom suitably tapped to receive 15 mm dia, 'B' class GI pipe and having clear opening of 220 mm at the top surface and 6 Nos. M10 tapped hole having centre to center distance of 260 mm alongwith bolts as required as per the drawings
Subhead I Supply items:- Supply of rectangular C.I. IsolatingTransformer housing box of Size 600mm (1)x 350mm(w) X 450mm(h),made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding having 2 no. equidistant holes of 90mm,100mm above the bottom of one side surface(600X 450mm); also a suitable hole of 50mm, from 75mm above the bottom centre at both side surface(350X 450mm) The box should have one each SS earth bolts of M10 x 40 mm tapped inside on both side surface(350X 450mm) and having two drain hole at the bottom suitably tapped to receive 2 no 15 mm dia, 'B' class GI pipe The CI top cover of size 600X350 mm with suitable rubber gasket and 8 Nos. M10 tapped hole and bolts as required as per the drawings and specifications.The housing box should have detachable stand of size 500mm (1)x 125mm(w) X100mm(h),made of 6 mm MS rod & legs made of 8 mm MS rod, suitable for keeping the isolating Transformers on the top surface of this stand etc as per the drawing.
Subhead- II SITC and ITC items:- Supply & installation of Guidance Sign Board of various sizes made out of anodized 2 mm thick Aluminium frame with suitable angle support with 1.5 MM thick Al. backcover of 4mm thick polycarbonate sheet with glare free face, the letter & symbol should be screen printed/ on inside of sign face made of self adhesive film of 3M applied on the inside face with required colouring, suitable arrangement shall be made for water tighness & locking arrangement, signboard shall be uniformly inernally illuminated with required LEDs to achieve illumination level operated on without flickering including supporting frangible legs & frame etc. complete as required and as specifiedas per ICAO Annex.14 Vol.I (legends as appoved by Engineer-in-Incharge).
Subhead- II SITC and ITC items:- SITC of all the equipment required to provide Airfield Lighting Control and Monitoring System (ALCMS) with future possibility of Individual Lamp Control and Monitoring (ILCMS) upgrade with ICAO/FAA compliance, including all hardware and software, licenses & other items as required for successful operation of the system in line with the scope of work, details of equipment, equipment specification, performance criteria i/c supply of Jn box containing 50 nos. terminals each copper conductor 2.5 sqmm size in MS cubical duly painted etc. Two Vault processor will be provided both running in parallel for redundancy in operation. Event logging & fault annunciation of all CCRs shall be provided as per enclosed specifications for following facilities. a) Runway circuit b) PAPI c) Approach Lights CAT II at approach of runway 30 d) Approach Lights CAT I at approach of runway 30 e) Approach Lights (SAPL) at approach of runway 12 f) Taxi, Apron, Isolating Bay & Link Taxi g) Threshold Lights 30/12 side circuit h) Illuminated Landing Direction Indicator i) Illuminated Wind Cone j) AAI Apron Flood Light Towers k) TDZ and RCL light l) Isolating Bay Lighting m) Runway Gaurd light n) Stop bar lights etc. o) Spares - 06 nos
Design, Supply, Installation, Testing & Commissioning of Main LT panel ,cubicle type, made out of 2 mm thick CRCA sheet, totally enclosed, IP 42, free standing, Floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50 Hz AC system with busbars extensible on both sides, making interlocking arrangement between incomers & buscoupler breakers, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc., including supply & installation of following switchgears, metering instruments and accessories in the LT Panel confirming to IS: 61439 specifications. (only TTA type of LT panel is acceptable.) INCOMERS 800 A, FP, 50 kA(Ics = 100% of Icu ), electrically operated drawout type ACB with Microprocessor based release having short circuit, over current, earth fault protection and having breaker control switch with inbuilt RS 485 communication port etc. - 02 sets. INSTRUMENTS Multi function meter - 02 sets 800/5 A, 15 KVA, CL-1 cast resin CTs - 06 Nos. R-Y-B phase indicating lamps, LED type - 02 sets Control MCBs. - 06 sets BUSBARS 1000 Amp, 415 V, TPN busbars of high conductivity electrolytic quality aluminium alloy duly insulated with coloured heat shrinkable sleeve and supported by FRP insulator - 01 set BUS COUPLER 800 A, FP, 50 kA(Ics = 100% of Icu ), electrically operated drawout type ACB with Microprocessor based release having short circuit, over current, earth fault protection and having breaker control switch with inbuilt RS 485 communication port etc. - 01 sets. ON indicating lamps(Red) LED type with control MCBs - 03 Nos. OUTGOINGS 400 A, TPN, 50 kA(Ics = 100% of Icu ), MCCB with thermal magnetic release having adjustable thermal & adjustable magnetic setting, spreader links, extened rotory handle etc. - 04 sets 125 A, TPN, 25 kA(Ics = 100% of Icu ), MCCB with thermal magnetic release having adjustable thermal & adjustable magnetic setting, spreader links, extened rotory handle etc. - 02 sets 100 A, TPN, 25 kA(Ics = 100% of Icu ), MCCB with thermal magnetic release having adjustable thermal & adjustable magnetic setting, spreader links, extened rotory handle etc. - 04 sets ON indicating lamps(Red) LED type - 10 Nos. Control MCBs. - 10 Nos.
Supply, installation, testing and commissioning of 2 nos. 200 KVA online UPS, microprocessor based double conversion type, indoor type, 3 phase input, 3 phase output, IGBT based PWM technology online double conversion type with in-built isolation transformer , suitable to drive constant current regulators (CCR) with following features: Designed output PF 0.9 at 40deg C THD<5% input Power factor 0.95 at 50% loading efficiency >=95% at 50 % load suitable for 3 phase AC input voltage 340V to 460 V, 50 Hz+3%/-3% pure sine wave output, compatibility of generator supply LCD/LED DISPLAY provision of UPS to run in load sharing mode, battery management features integrated with main UPS controller IGBT based, rectifier cum charger and inverter 100% rated inbuilt static switch at inverter output + 2 nos. 100% rated inbuilt static switches at static bypass line static bypass, maintenance bypass active input power factor correction Web-enabled monitoring and management through SNMP protocol for multi OS environment Inbuilt feature required for input phase sequence protection and automatic change. UPS should work on mains and should not go to battery mode in case of input phase sequence changed. Battery confuguration: Supply installation testing and commissioning of 02 nos. battery bank (one for each UPS), 12 V and sufficient VAH rating (as per approved design and calculation) for minimum 30 minute backup time to each 200 KVA UPS for full load , suitable rating circuit breakers, interconnection of batteries with cabling by copper conductor, connection with UPS to battery bank, glanding, terminations etc. SITC of matching cabinet / open racks to house above mentioned batteries alongwith suitable size cable etc. complete as required. SITC of transient voltage surge suppressors of suitable rating for high surge suppression - 02 nos.
Supplying and laying of following sizes PN 6, PE 80 rating HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. a) 50 mm dia (OD)
63 mm dia (OD)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ X 35 sq. mm
3½ X 70 sq. mm
3½ X 300 sq. mm
4 x 16 sqmm
Supplying and making end termination with brass compression gland and copper lugs for following size of airfiled copeer cable of 5 KV grade as required. 1 X 6 sq. mm / 1 x 16 Sq.mm
Installation, testing and commissioning of all types of inset fitting with core drilling, aligning and setting i/c installation of Isolating Transformer, Crimping / Jointing of secondary connectors, and other accessories required for commissioning i/c supply of all materials except lighting fixture, secondary lead, plug & receptacles, lamp & isolating transformer etc. as required.
Installation, testing & commissioning of all types of elevated fittings i/c installation of isolating transformer, crimping/jointing of plug & receptacles, i/c supply of all materials excluding fixture, secondary lead, plug & receptacles, Lamp & isolating transformer etc. as required.
Installation, testing & commissioning of 2.5/ 4 /7.5 KW rating of CCR i/c required foundation, grouting etc. complete as required.
Installation, testing & commissioning of 15/20/30 KW rating of CCR i/c required foundation, grouting etc. complete as required.
Installation of CI housing box round type, of size 330 mm dia and 450 mm deep inside bitumen macadum/PQC surface of runway/shoulder/taxiway i/c cutting of surface, providing 250 mm long 15 mm dia 'B' class GI pipe in the bottom surface for drainage of water etc., cutting & suitable threading of pipe and housing box ,i/c adjustment of housing with the dolite etc, refilling the surface and making good the same as original as required.
Installation of CI housing box of size rectangular C.I. Transformer housing box of Size 600mm x 350mm X450mm height inside bitumen macadum/PQC surface of runway/shoulder/taxiway i/c cutting of surface, providing two no, 250 mm long 15 mm dia 'B' class GI pipe in the bottom surface for drainage of water etc., cutting & suitable threading of pipe and housing box ,i/c adjustment of housing with theodolite etc, refilling the surface and making good the same as original as required.
Installation of CI housing box round type of size 330mm dia and 450mm deep in open unpaved area providing 250mm long 15 mm dia 'B' class GI pipe in the bottom surface for drainage of water etc., cutting & suitable threading of pipe and housing box, excavation of surface, cement concrete all round (1:2:4) of 100 mm thick CC inculding bottom, refilling the surface and making good the same as original as required.
Installation of CI housing box of size 600 x 350mm x 450mm deep in open unpaved area surface i/c providing 250mm long 15 mm dia 'B' class GI pipe in the bottom surface for drainage of water etc., cutting & suibtale threading of pipe and housing box , excavation of surface, cement concrete all round (1:2:4) of 100 mm thick CC inculding bottom, refilling the surface and making good the same as original as required.
Numbering of GLF fittings by synthetic enamil paint complete as per instruction of engineer-in-charge.
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5 %, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. a) 300mm width X 50mm depthX 1.6mm thickness
150mm width X 50mm depth X 1.60mm thickness
Laying of one number Airfiled ground lighting cable of 5 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. Size 6/16 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Laying of one number PVC insulated secondary lead in the existing RCC/ HUME/ METAL/ HDPE pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number Optic fibre cable in the existing masonary trench/HDPE pipe etc. as required.
Kerf cutting of suitable size i/c chipping, hammering, cleaning, & drying etc. and refilling the kerf with sealant materials including primer etc. in bitumin/PQC surfaces laying of following numbers of secondary leads:- a) Upto 1 No. Secondary lead of size 2x4 sq.mm.
Upto 2 No. Secondary lead of size 2x4 sq.mm.
Upto 3/4 No. Secondary lead of size 2x4 sq.mm.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
TARMAT LIMITED
AMA Private Limited
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid