| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.4 LAccepted-AOC DR SEWALIYE SIVAJI GANESAN NAGAR 3RD STREET DINDIGUL 642 001 | COIMBATORE | TAMIL NADU | 642001 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹1.0 Cr+₹3.6 L (3.60%)Rejected-Finance C 150 ADG P CHENNAI | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹1.0 Cr+₹5.3 L (5.41%)Rejected-Finance 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹1.1 Cr+₹8.2 L (8.30%)Rejected-Finance NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹1.1 Cr+₹8.2 L (8.31%)Rejected-Finance 7 345 C 1 AERO NAGAR KANGEYAMPALAYAM KADAMPADI SULUR COIMBATORE TAMIL NADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
16 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF CERTAIN WORKS SERVICES FOR INDUCTION OF TESTERS INCLUDING CERTAIN SANCTIONED WORKS AND MINOR WORKS IN TECHNICAL AREA AT AF STN SULUR
2023_MES_576310_1
8545/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹1.5 L
Yes
20 Feb 2023
20 Jan 2023
17 Feb 2023
20 Jan 2023
16 Feb 2023
10 Feb 2023
20 Jan 2023 - 6 Feb 2023
Amount
SCHEDULE A BOQ
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., including removing debris material to out side MD land complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar and removal of debris complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Note for Item No 4 :- The material obtained from demolition shall be disposed outside MD land and the unit rate is deemed to be inclusive for this provision
M & L brickwork with fly ash’ bricks using with old size bricks, straight or curved on plan exc 6m mean radius built in cm 1:4 , complete all as specified and as directed
M&L Rendering 15 mm thick in two layers on brick or concrete surfaces,first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:6 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete complete all as specified and directed.
Note for Item No 7 :- Water proofing compound shall be measured and paid seperately. However, labour aspect for Mixing water proofing compound is deemed to be included in this item
Supply Only integral water proofing compound complete all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6 complete including dismantling of existing tile and disposal off to outside MD land all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 complete including dismantling of existing tile and disposal of to outside MD land all as specified and as directed.
Note for item No 10 & 11 :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm.
(ii) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
M&L Preparation of new plastered surfaces wall/ ceiling and applying two coat of white wasing on ceiling/ walls surfaces complete all as specified and directed.
M&L Preparation of new plastered surfaces wall applying two coat of OBD over a coat of alkali resistant priming paint complete all as specified and directed.
M&L False ceiling using GI snap grid size 60x60cm with main runner 38x24,wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with 4mm thick designer ceiling board Including taking down existing one complete all as specified and as directed by Engineer-in-Charge
M&L Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , treading, oil, greasy spots and applying one coat oil bound distemper complete all as specified and as directed.
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for laying XLPE cable, foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and getting out in hard/ dense soil complete all as specified
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and as directed.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and as directed.
Note for Item No 21 :- In case sufficient sand not obtained from excavation, the required additional qty shall be obtained from out side MD land as directed by the Engineer-in-Charge and the rate is deemed to be included the above provision also.
Supply and lay fly ash old size brick for cable protection of size 23x11.5 x7.5cm with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
M&L XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 185 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, etc all as specified and directed.
M&L XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 50 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, etc all as specified and directed.
Note for Item No 24 & 25 :- Excavation and earth work riddling sand, bricks etc shall be measured and paid seperately under relevent items here-in-above
M & L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed.
Notes for item No 27:- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge user and proper record shall be mainted duly signed by all concerned.
(e) After testing if desired earth resistance of less than 3 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Supply, insallation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3 mm thick MS sheet duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and shall be CPRI approved and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted including excavation and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in foundation as per as site requirement. The minimum claerance to the bottom of the panel from the ground level is 450 mm complete all as specified and directed and comprising of following :-
(a) TPN Aluminium bus bar 315 Amps, 35 KA - 01 set (b) MCCB 150 Amps, 4 pole, 25 KA - 01 Nos (c) MCCB 100 Amps, 4 pole, 25 KA - 02 Nos (d) Digital Multifunction Meter to measure Volt, Amps, PF etc. for three phase, with CT-1 sets (e) LED indication lamps with backup MCB for 3 phase supply –1 set. (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge).
Supply and fix IP 65 polycarbonate MCCB distribution board of size 680X420x160mm with polycarbonate hinges, complete with 4 pole, 100 Amp, 25 KA, 415 V MCCB conforming to IS :8623 fitted with color coded sheathed bus bars RYB & Neutral bar, earth bar,DIN channel with IP 65 polycarbonate window for operation of MCCB without opening the enclosure. The enclosure should be dust & water proof with anti cracking, high temp resistant silicon sealing gaskets for weather proof outside mounting. It should be CE for safety of retardant UL 94 VO, UV resistant, Impact conforming to IEC60529, the enclosure should be suitable for wall/flush mounting. All hardware used should be made of SS304
Supply and fix IP 65 polycarbonate MCCB distribution board of size 680X420x160mm with polycarbonate hinges, complete with 4 pole, 63 Amp, 25 KA, 415 V MCCB conforming to IS :8623 fitted with color coded sheathed bus bars RYB & Neutral bar, earth bar,DIN channel with IP 65 polycarbonate window for operation of MCCB without opening the enclosure. The enclosure should be dust & water proof with anti cracking, high temp resistant silicon sealing gaskets for weather proof outside mounting. It should be CE for safety of retardant UL 94 VO, UV resistant, Impact conforming to IEC60529, the enclosure should be suitable for wall/flush mounting. All hardware used should be made of SS304
Supply, install, test and commissiong on-line UPS (Uninterrupltible Power supply ) of 120 KVA having system with input voltage 415 volts, Three phase and output voltage 415 volts three phase with automatic static switch and manual bypass arrangement including battery bank comprising 12 V, 120 AH, SMF Batteries -64 Nos having minimum 30 minutes back up at full load having IGBT sine weighted PWM technology, forced cooling type internally prewired complete with all accessoreis and including digital type multifunction meter for battery ON/ Off switch, manual bypass switch for servicing purpose static switch for automatic transfer to mains in case of inverter failure, LED indicating lamps for mains and for output U,V,W. The UPS shall have protection against output under/over voltage over load/shoart circuit, input over/under voltage, input phase fail/reversal, low battery over temperture, IGBT fuse protection, and the system shall be housed in MS sheet steel cabinet having wheels with IP-21 protection and duly painted with powder coated paint. The UPS shall be an upright, free standing with removable side covers hinge mounting front and back doors. AC filter chokes & transformers are mounted on the bottom plate of the cabinet. Cable entry holes shall be provisioned at bottom side of the cabinet. Battery stand alongwith necessary battery interconnection by providing copper cables. The UPS shall meet the techncial parameters such as input voltage 415 volts (+/-) 1% : Frequency 50 HZ (+/-) 6%. Power factor 0.8 lag to unity at output, voltage output 230 voltage phase to neutral, voltage adjustment (+/-) 10% of normal voltage, Regulation (+/-) 1% for 10 % to 100 % load variation area and (+/-) 1% for (+/-) 15 % input supply variation, voltage balance (+/-) 2% for balanced load and (+/-) 3% for 50 % unbalanced load , over load at 125 % for 5 minutes and 150 % for 10 second complete all as specified and directed.
Note for Item 37:- (i) The equipment shall be identified by printing or fixing stickers duly mentioned the CA number and date of commissioning
(ii) The Warranty period for equipment shall be 5 Years from the date of commissioning.
(iii) Contractor shall provide Warranty for 24 months from the date of commissioning of Batteries.
(iv)A security deposit of value equal to 2.5 % of the rate quoted shall be retained from payment due to the contractor for the warranty period.
Supply installation, testing & commissioning of maintenance free chemical earthing consisting of copper bounded pre-welded electrode of 10 feet length, 17.2 mm dia made of high tensile low carbon steel rod with 250 micron (average) molecularly bounded copper on the outer surface confirming requirements of UL- 467 with exothermically joint together should be tested on 25 KA fault current with provision for connection clamp of size 150 mm long, 5 mm thickness with 12 mm dia hole of 4 numbers for termination on top of copper bonded rod along with 50 Kg eco friendly Back Fill compound with each earth rod including taking down old unserviceable earthing materials. The Back Fill compound should be tested to achieve 0.02ohms. The Back fill Compound should comply to IEC 62561-7 having passed leaching, corrosion, sulphur and resistivity test as per IEC-62561-7 by NABL accredited Lab, size of bore 6-8 inch, 11 feet depth, distance between each bore shall be 3 mtrs long the above installation shall be completed with 10 liters of Super Charger Earthing liquid tested by any NABL agreated laboratory tested as per IEC-62561-7, read with ASTM G57-06, CI 3.4.A.
Note for Item No 42 :- The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (copper strip shall be measured and pair seperately) .
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
M&L Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed.
Supply and fixing copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc complete all as specified and directed.
Note for Item No 62:- All Joints should be joined by Exothermic Welding or Brazing.
S&F epoxy base insulators of suitable size 40mm height for fixing copper earth strip on wall/ceiling/floor/poles etc complete all as specified and directed.
Note for Item No 64:- Quoted Unit Rate deemed to be included for drilling holes per Metre as specified on GI/Aluminium/Copper Strip of any type and size.
Supply and laying Single Core Cable with copper conductor PVC round sheathed (flexible) industrial cable 1100 volts grade with multi stranded conductor of size 10 sqmm including necessary thimble, lugs and clips complete all as specified and directed
Supply, install, testing and commissioning Static Frequency converter 3 KVA, IP 42 Enclosure, having input Voltage 415 Volt AC 3 Phase 4 Wire + 10%, - 20% Frequency 50 Hz, Frequency variation 10% variation in between 45 to 55 HZ , Output supply of 3 Phase 4 wire +/- 1% 115 V AC L-N supply frequency 400 Hz +/- 0.5%, Harmonic Distortion < 3% on linear load and the equipment shall be capable to withstand over load rating 100% to 110% for 30 Minute, 111% to 125% for 5 minute and 170% overload for 30 Seconds and load power factor 0.8 lag to unity within KW rating, operating temperature 0 to 45 Deg C complete.The efficiency of the Invertor shall be at 100% load > 85%.
The equipment shall consist of protection devices having, input AC Over Voltage / under voltage, DC Over Voltage Battery charging / over current / reverse phase sequency, MCBs for input , Battery & output,. Output over voltage / under voltage , output over load / DC under voltage temperature, Phase fail, Mains fail, forced air cooling, Battery low pre alarm & system trip complete. The Equipment shall consist Scanning facility to monitor all parameters, microprocessor based digital display ,metering device consists of LCD display with scroll, button to read various inputs & out put parameters system status will display on LCD meter as precondition such as Out put low / output high / output overload, under frequency / over frequency SFC ON / SFC OFF and alarm reset complete.. The SFC shall have LED indications for analog version 3 Phase output, alonwith wall mounted MDP & SDP and cable from MDP to equipment & from equipment to SDP complete all as directed.
Note for Item No 67:- (i) All other specifications & testing as per DGQA and latest relevant IS as applicable.
(ii) The equipment shall be identified by printing or fixing stickers duly mentioned the CA number and date of commissioning
(iii) The Warranty period for equipment shall be 5 Years from the date of commissioning.
(iv) Contractor shall provide Warranty for 24 months from the date of commissioning of Batteries
(v) A security deposit of value equal to 2.5 % of the rate quoted shall be retained from payment due to the contractor for the guarantee period.
Supply, install, testing and commissioning, of DC power supply (rectifier) 3 KW, capacity having 28 Volt +/- 1% DC power supply, IP 42 Protection, with input three phase 4 wire , 400 volts AC + / - 20% , Frequency 50 Hz +/- 10% and DC out put 28 Volts and line ripple less than 1 V RMS at 28 Volts DC voltage.The DC power supply shall be able of sudden application or removal of 100% of full load at base load of 0% or viceversa the voltage dip / rise shall not exceed 10% of nominal voltage recover to regulation band within 10 cycle. The equipment shall be capable to withstand 110% overload for 30 minute, 125% overload for 5 minutes and 150% overload for 1 minute. The efficiency of DC power supply equipment shall be.> 89%. The high reliability fans are to be used for spot cooling and failure of fan should not offer the system performance.
The equipment shall be provided with MCB for AC input, Fast acting Semiconductor Fuse for Rectifier Bridge, Current limit protection, Thermal overload protection , Forced Air cooling, Programmable relay for input O / U Voltage, over heat and phase fail, Snubber circuit for power rectifier and operating temperature 0 to 45 degree centigrade. The equipment shall be provided with a microprocessor based display having scanning facility to monitor all parameters having LCD for monitoring output voltage and current,LCD for monitoring input voltage indication through LED, AC mains ON (R,Y,B), DC ON, Output ON, Over load, Mains over / under voltage and over heat indications, complete. The Rectifier shall have special features such as soft start on DC side, Class - F insulation for all magnetics and automatic voltage regulation and current limiting ,alonwith wall mounted MDP & SDP and cable from MDP to equipment & from equipment to SDP complete all as directied.
NOTE for Item No 74:- (i) All other specifications & testing as per DGQA and latest relevant IS.
(ii) The equipment shall be identified by printing or fixing stickers duly mentioned the CA number and date of commissioning
(III) The Warranty period for equipment shall be 5 Years from the date of commissioning.
(v) A security deposit of value equal to 2.5 % of the rate quoted shall be retained from payment due to the contractor for the guarantee period
M&L point wiring using approved colour coding as per IS with PVC insulated, unsheathed FRLS multi stranded copper conductor 4 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through and including stove enamelled steel Conduit, ISI marked including 4 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly for One 3 pin socket outlet. 15 amps, independent, complete all as specified and as directed.
Supply and fix modular socket multipurpose 2-in-1, 6/16 Amps, 2/3 pin combined 2 module all as specified and as directed.
Supply and Fix modular switch 1 way 16 amp.1 module all as specified and as directed.
Supply and fix modular metal flush box 3 module all as specified and as directed.
Supply and fix modular white cover plate with frame 3 module all as specified and as directed.
S&F factory made powder coated distribution board SPN, 4 way single door, including bus bar rating 200 Amp, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
Supply & fix single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified
S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Supply & laying synthetic Rubber insulated mats of size 2.0 m X 1.0 m with thickness 2.5 mm suitable for voltage upto 11 KV as per IS 15652-2006 suitable for electrical shock safety complete all as specified and directed.
M & L Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl Stove enemelled steel conduit with accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with plastic laminated top cover 2.8mm fixed with cadmium plated iron screws etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for one flame proof light point controlled by one switch complete all as specified and directed.
S&F Switch flame proof rotary type with termination box in LM6, 16A, double pole 250V complete all as specified and directed. Make:- M/s Sudhir, Baliga or equivalent
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size stove enamelled steel conduit and all accessories fixed to wall/floors along with 2 runs of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed
Note for Item No 92:- (a) 4 runs of 6 sqmm cable along with 2 runs of 6 sqmm cable for earth conductor and one run of stove enamelled steel conduit shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amp, 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete all as specified and directed.
Supply and fix of high power LED street light fittings energy saving luminaire with lens , capacity 70 watt with system efficacy (lm/w) shall be >140 lumen per watt or more lumens per watt, Beam angle - Road Optic, total system lumen not less than 9800 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5700K, surge protection not less than 4 KV, high pressure die cast aluminium alloy LM6 housing IP-65 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50/60 Hz ( + 5%), THD< 10% including taking down existing street lights complete all as specified. Make : Philips cat pat No. BRP501 LED078 CW R5C PSU S1 or Equivalent of Havells/Wipro.
Note for Item No 96 :- Old street lights obtained shall be fixed at locations as directed by the Engineer-in-Charge and the fixing charge shall be measured and paid seperately under relevent item here-in-after.
Supply and fixing of IP 66 Polycarbonate weather proof Pole Junction Box, Dim:- 255L x 205B x 112D MM with plain walls for cable entries to be drilled individually, system voltage : 415V, 50hz, The plain side walls on the four sides can be drilled and customized for cable entries from any direction. Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. The juction box shall be facilitate the followings:- (i)Cable terminal :- 25 Sq mm- 4 Nos (ii)10A SP MCB- 1 No (iii)6sq mm disconnected terminal- 1 No
Note for Item No 98 :- The junction box shall fulfill the following standards:- Weatherproof : UV resistant due to solar radiation, Rainwater proof, temperature resistant.Salt water proof & shall be suitable for off-shore applications. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C. IEC 60529 : IP 66 / IP 67 / IP 69 degree of protection.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 1.5 sqmm drawn through in and incl suitable size non metallic PVC conduit and all accessories fixed to wall/floors along with 1 run of 1.5 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed
Note for Item No 100:- (a) 2 runs of 1.5 sqmm cable along with 1 run of 1.5 sqmm cable for earth conductor and one run of non metallic PVC conduit shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Supply and fix PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed.
Supply and fix PVC insulated Copper Conductor Cable 2.5 Sqmm, 3 Core Round Flexible for connection of flood Light Fitting, complete all as specified and as directed.
Supply and fix GI tubing 40/50 mm bore light grade 1.2 mtr long bent to shape as required with clamps for fixing of street light on poles/ walls including nuts, bolts, washers clamps of suitable size complete all as specified and as directed.
Supply and fixing GI tubing 25 mm bore light grade of length 1.8 mtr bent to shape of "Y" for fixing two street lights in one bracket on wall in the area of low level lighting as required with clamps for fixing of street light on poles/ walls including nuts, bolts, washers clamps of suitable size complete all as specified and as directed.
Fixing only street lights received from item No 96 at post,wall, or any other positions including neccessory connections such as wires. Thimbles, nut, bolt etc all as specifed and directed by Engr In Charge.
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for laying XLPE cable, foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and getting out in soft/loose soil complete all as specified and directed
All as per item No 108 above, but exc 1.5m deep but not exceeding 3.0m deep and getting out in soft/ loose soil complete all as specified and directed
Supply and lay LT XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed.
Supply and lay LT XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed.
Supply and lay LT XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including all as specified and directed.
Supply and lay LT XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 6 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed.
Note for Item No 110 to 113 :- Excavation and earth work riddling sand, bricks etc shall be measured and paid seperately under relevent items here-in-above
Supply, transporting to site, errecting and fixing in position, steel tubular swaged poles of 9 mtr long type 410 SP- 31, IS-2713 marked complete with CI/ MS base plate, finial taper plug, bolts, nuts, washers and screws as specified, drilling of necessary holes including painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and black bituminous paint on steel surface embeded in conrete externally and throughout internally and painting 03 nos of band /strips with fluorescent , PO box red synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and number of poles etc all as specified & directed by Engineer-in-Charge.
Supply, transporting to site, errecting and fixing in position, steel tubular swaged poles of 11 mtr long type 410 SP- 55, IS-2713 marked complete with CI/ MS base plate, finial taper plug, bolts, nuts, washers and screws as specified, drilling of necessary holes including painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and black bituminous paint on steel surface embeded in conrete externally and throughout internally and painting 03 nos of band /strips with fluorescent , PO box red synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and number of poles etc all as specified & directed by Engineer-in-Charge.
Note for Item No 115 & 116 :- Earth work excavation, PCC foundation, coping will be measured and paid separately.
Supply and fix cross arm using standard mild steel sections like angle iron / MS pipe / flat iron / nut bolt and washers etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to fixing of flood lights on pole complete all as specified and directed by Engr in charge.
M&L Plain Cement Concrete (1:4:8) type D2 (using 40 mm graded stone aggregate)as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for providing cement concrete 1:3:6, type C2(using 40mm graded stone aggregates) including necessary form work for pole foundation complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4 ,Type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Supply and fix Synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controling street lights/ flood lights etc all as directed. Make:- Cat Part No : 4126 41 of Legrand L&T, ABB or equivalent.
Supply and fix Power contactors 63 Amps, 4 pole, 415V etc all as directed Make : Cat No 4125 57 of Legrand / L&T/ Siemans or equivalent
Supply and lay GI pipe 40 mm bore light grade for cable protection complete all as specified and as dierced by Engr-in-Charge.
Supply and fixing LED flood light fitting 75 Watts 240 Volts, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 8200lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 5700K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as directed. Make : Philips Cat No BVP192 LED 82 CW HO NB FG GR PSU or Havells/Wipro or equivalent.
Supply and fixing LED flood light fitting 100 Watts 240 Volts, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 11000lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 6500K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as directed. Make : Philips Cat No BVP192 LED 110 CW HO NB FG GR PSU or Havells/Wipro or equivalent.
Supply and fixing LED flood light fitting 160 Watts 240 Volts, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 17600lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 6500K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as directed. Make : Philips Cat No BVP192 LED 172 CW HO NB FG A1 GR PSU or Havells/Wipro or equivalent.
Supply and fixing LED flood light fitting 210 Watts 240 Volts, System wattage 195 W, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 23500lm, operating voltage range from 120V to 277V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 5700K to 6500K, Surge protection from overvoltages 5kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-160lm/w complete all as directed. Make : Philips Cat No BVP483 LED 235 CW AMB PSU GR or Havells/Wipro Equivalent.
Supply and fixing convetional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground complete all as specified and as directed. Make : CG Cat No. LPTO-40-CDL/Bajaj Cat Part No. BRIL 45 W LED NW or philips or equivalent approved make.
Supply and fixing ALCOR LED flood light, 50 watts RGB colour changing light, 240 Volt, with high quality lenses & reflector, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-66 class of protection, complete with control gear and all accessories including necessory PCC foundation for placing of flood light complete all as specified and directed by Engr in charge. Make : Luker cat pat No. LFLR 50 or Havells/Wipro or Equivalent.
Supply and fixing pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MD land complete all as specified and directed by Engineer-in-Charge. Make / Model of Light fitting : Athena 3 (MOON) of Havells Cat Part No : LHDC11126099 or Wipro / CG or equivalent.
Supply and fixing convetional type bollard fitting with LED light fittings suitable for 1x9 watt LED bollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make /cat part No. CG cat no.LBLSN-10-CDL or Wipro / CG or equivalent approved make.
Taking down carefully stand alone solar LED street light 44 W with maintenance free battery including decorative light of lux- 6000 lumen, pole with solar panel RAL-black, shifting up to a distance of 5 Km and fixing/errecting by providing necessary excavation, earth work, PCC foundation and foundation bolts complete all as specified and directed.
Note for Item No 133 :- (i) The quoted rate deemed to be inclusive for necessary Earth work excavation, PCC for foundation and foundation bolts & nuts.
(ii) No T&P shall be issued by the department. Necessary T & P and vehile for shifting the street light shall be arraged by the contractor at own cost and the quoted rate is demmed to be included for the same.
(iii) If any damages happened to street light during lifting/ shifting/ installation work, the same will be rectified by the contractor without any extra cost to the Govt, or otherwise, suitable recovery shall be affected from the contractor’s bill for which decision of Accepting Officer will be final and binding on the contractor
Supply and fixing Revolving search light 300 W LED High intensity, long range, weather proof, energy saving, instant glow, LED search light, beam range 700 meters (as per model), Single LED light, Efficiency >140 lm/w, PF >0.95, CCT ~ 6000K, Optical grade PMMA-PC lens, narrow beam 8 degree, die cast LM6 body with air fins, toughened front glass sealed with silicon gasket, fully powder coated, wide range of working voltage 90 - 300 AC, protection against over volt & under volts, reflector lens efficiency >90%, average lux level at 10 meter is approx. 2000 - 6000 lux (as per model) with circle of approx 1meter, confirming to LM79 & LM80. This search-light is ready to installed on rotating disc of auto revolving mechanism. Degree of protection : IP65 and the stand would be suitable for mounting of search lights on its rotating disk on top side. It is made of iron/steel with epoxy powder coating weather proof paint on surface. The stand has designed so that the search light can be rotate one full round horizontally and 30 degree vertically & can be locked at any position at any time. It would be 4 nos. high grade PVC castor wheels at bottom for easy movement on the platform with wheel locking arrangement. The height of tripod stand is generally 1 Meter above from the bottom.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size non metallic PVC conduit and all accessories fixed to wall/floors along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed
Note for Item No 138:- (a) 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of non metallic PVC conduit shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Supply and fix White cover plate with frame, 1 module complete all as specified and as directed.
Supply and fix Metal flush box 1/2 module complete all as specified and as directed.
Supply and fix Modular Bell push 6A 1 module complete all as specified and as directed.
Supply and fix Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and as directed.
Supply and fix ceiling rose, surface type Bakelite 65x55mm 3 terminal complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Taking down ceiling fan carefully along with hanging rod and clamps and deposite the fan to MES store duly removing the leafs, hanging rod etc and refixing the ceiling fan by providing new down rod of 15mm dia (length not less than 60cm and not more than 90 cm) with hanging clamps all as specified and directed.
S.RAMACHANDRAN
S KUMARAN
shalom constructions
p.chinnasamy
KRISHNA ENTERPRISES
KSR AND COMPANY
M/s.Sai Agency
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .