Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAdmitted-Finance | ₹1.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 Cr+₹34.8 L (33.2%)Admitted-Finance | ₹1.4 Cr+₹34.8 L (33.2%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/s Shri Balaji Traders L2 | HS Associates L1 |
|---|---|---|---|---|---|
| 1.00fo|qr forj.k [k.M & nknjh ds {ks=kUrxZr iqjkuh ,.M ttZj ,oa vR;f/kd [kjkc 11 ds0oh0 ykbu xzke Åapk vehjiqj [kxkSMk ,oa esgjkt x<h ds d.MDVj dks cnyus ,oa I;koyh midsUnz mDr xzkeksa dk tksMus dk dk;ZA | |||||
| 2.00Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 3 to 23 | |||||
| 3.00 | PCC Pole 8.5 mtr. Long | 1 | No. | 1,000 ₹85,000 | 600 ₹51,000 Lowest |
| 4.00 | PCC Pole 11 mtr. Long | 1 | No. | 1,000 ₹25,000 | 600 ₹15,000 Lowest |
| 5.00 | ACSR Rabbit Conductor | 1 | Mtr | 5 ₹76,100 | 2 ₹30,440 Lowest |
| 6.00 | ACSR Dog Conductor | 1 | Mtr | 5 ₹24,700 | 2 ₹9,880 Lowest |
| 7.00 | Insulated Dog Conductor | 1 | Mtr | 5 ₹21,100 | 2 ₹8,440 Lowest |
| 8.00 | T off Channel For 11 KV | 1 | No. | 80 ₹1,760 | 50 ₹1,100 Lowest |
| 9.00 | 11 KV Dropper Channel | 1 | No. | 80 ₹1,600 | 50 ₹1,000 Lowest |
| 10.00 | 11 KV Top Channel | 1 | No. | 80 ₹800 | 50 ₹500 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
3 Oct 2025, 12:00 pmClosed
Superintending Engineer
Office of the S.E., EUDC-II, Sec-18 (Ansal) Noida
11 KV Line Strenthing Work in BP 2025-26 Under EUDC-2, Noida.
2025_PVVNL_1073221_1
E-Tender No. 34/2025-26, EUDC-II, Noida
Open Tender
Electrical Works
Item Rate
30 days
Office of the S.E., EUDC-II, Sec-18 (Ansal) Noida
Attached in DOC
2 documents required · 2 mandatory
₹5,900
S.E., EUDC-II, Noida.
₹1.1 L
8 Oct 2025
11 Sept 2025
3 Oct 2025
11 Sept 2025
3 Oct 2025
11 Sept 2025
Amount
fo|qr forj.k [k.M & nknjh ds {ks=kUrxZr iqjkuh ,.M ttZj ,oa vR;f/kd [kjkc 11 ds0oh0 ykbu xzke Åapk vehjiqj [kxkSMk ,oa esgjkt x<h ds d.MDVj dks cnyus ,oa I;koyh midsUnz mDr xzkeksa dk tksMus dk dk;ZA
Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 3 to 23
PCC Pole 8.5 mtr. Long
PCC Pole 11 mtr. Long
ACSR Rabbit Conductor
ACSR Dog Conductor
Insulated Dog Conductor
T off Channel For 11 KV
11 KV Dropper Channel
11 KV Top Channel
Bracing Angel 65x65x6 mm
11 KV V Type Cross Arm
Pin Insulator 11 KV
Disc Insulator 11 KV
Stay Complete
Garding Angle
Distribution Box
LT ABC 3x35 sqmm
LT ABC 3x120 sqmm
11 KV XLPE Cable 3x185 sqmm J/C
11 KV XLPE Cable 3x185 mm
11 KV XLPE Cable 1x400 sqmm
TF Fuse set
Errection of above Centralised material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) ST - 11 Mtr Lone Pole, PCC 8.5 Mtr Long Pole and PCC 11 Mtr Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per RESPO. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole and Single Pole Structures (a) ST - 11 Mtr Lone Pole, PCC 8.5 Mtr Long Pole and PCC 11 Mtr Pole
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Road Restoration charges shall be inclusive in quoted rates. Single Pole and Double Pole (a) ST - 11 Mtr Lone Pole, PCC 8.5 Mtr Long Pole and PCC 11 Mtr Pole
Laying, Strenthging of ACSR Rabbit Conductor in 3or 4 parallel ways as per site requirement.
Laying and strengthing of ACSR Dog Conductor as per site requirement.
Laying and Sagging of Insulated Dog Conductor as per site requirement.
Fixing of T off Channel For 11 KV as per site requirement.
Fixing of 11 KV Dropper Channel as per site requirement.
Fixing of 11 KV Top Channel as per site requirement.
Fixing of Bracing Angel 65x65x6 mm as per site requirement.
Fixing of 11 KV V Type Cross Arm as per site requirement.
Fixing of Pin Insulator 11 KV as per site requirement.
Fixing of Disc Insulator 11 KV as per site requirement.
Fixing and proper grouting of Stay Complete as per site requirement.
Fixing of Garding Angle as per site requirement.
Fixing of three phase Distribution Box as per site requirement.
Laying and Sagging of LT ABC 3x35 sqmm as per site requirement.
Laying and Sagging of LT ABC 3x120 sqmm as per site requirement.
Making and Fixing of 11 KV XLPE Cable 3x185 sqmm J/C by Jointer as per site requirement.
Laying of 11 KV XLPE Cable 3x185 mm by manual trenchmethod with one side of sand and three side of bricks as per RESPO.
Fixing of 11 KV XLPE Cable 1x400 sqmm as per site requirement.
Fixing of 11 KV TF Fuse set as per site requirement.
Dismentaling and Removal of Old & Jarjar Conductor and Cable from work Site and Safe Carriage of its from work site to any store of PVVNL Discom including loading and unloading both ends.
Supply and Errection of below De-Centralised/Market material for completing the works as per RESPO. (Contractor will provide the material at his own cost.)
Supply and Fixing of Stone Pad as per site requirement.
Supply and Fixing of F Bracket as per site requirement.
Supply and Fixing of Holding Clamp For PCC Pole 8.5 mtr long as per site requirement.
Supply and Fixing of MS Nut and Bold size 4x3'' as per site requirement.
Supply and Fixing of Danger Board as per site requirement.
Supply and Fixing of GI Wire 4 mm 8 SWG as per site requirement.
Supply and Fixing of EYE Bolt as per site requirement.
Supply and Fixing of Suspension Clamp as per site requirement.
Supply and Fixing of Piercing Clamp as per site requirement.
Supply and Fixing of Al. Lugs 35 sqmm as per site requirement.
Supply and Fixing of Pad Lock as per site requirement.
Supply and Fixing of Lock as per site requirement.
Supply and Fixing of Dead End Clamp as per site requirement.
fo|qr forj.k [k.M & nknjh ds {ks=kUrxZr 11 ds0oh0 jkex< QhMj ds vksYM ,.M ttZj ,oa vR;f/kd [kjkc 11 ds0oh0 ykbu xzke chy vdcjiqj ls nrkoyh rd ds d.MDVj dks cnyus dk dk;ZA
Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 65 to 81
PCC Pole 11 Mtr Long
PCC Pole 8.5 Mtr Long
Stone Pad
Acsr Dog Conductor
11KV Cross Arm
11 KV Pin Insulator with pin
Earthing Complete
Errection of above Centralised material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) ST - 11 Mtr Lone Pole, PCC 8.5 Mtr Long Pole and PCC 11 Mtr Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per RESPO. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole and Single Pole Structures (a) ST - 11 Mtr Lone Pole, PCC 8.5 Mtr Long Pole and PCC 11 Mtr Pole
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Road Restoration charges shall be inclusive in quoted rates. Single Pole and Double Pole (a) ST - 11 Mtr Lone Pole, PCC 8.5 Mtr Long Pole and PCC 11 Mtr Pole
Laying, Sagging strengthning and Re-Sagging of ACSR Dog Conductor with 3 or 4 parallel ways as per site requirement.
Fixing of Stone Pad as per site requirement.
Fixing of 11KV Cross Arm as per site requirement.
Fixing of 11 KV Pin Insulator with pin as per site requirement.
Fixing of Earthing Complete as per site requirement.
Supply and Errection of below De-Centralised/Market material for completing the works as per RESPO. (Contractor will provide the material at his own cost.)
Supply and Fixing of E Bracket as per site requirement.
Supply and Fixing of Number Plate as per site requirement.
Supply and Fixing of G I Barbed wire as per site requirement.
Suppy amd Fixing of Nut Bolt and Washers as per site requirement.
Supply and Fixing of Holding Clamps as per site requirement.
Supply and Fixing of Danger Board as per site requirement.
Dismentaling and Removal of Old & Jarjar Conductor and Cable from work Site and Safe Carriage of its from work site to any store of PVVNL Discom including loading and unloading both ends.
fo|qr forj.k [k.M & tsoj ds {ks=kUrxZr 23 ua0 fofHkUu LFkkuksa ij ttZj ,oa vR;f/kd [kjkc 11 ds0oh0 ykbu ds d.MDVj@dsfcy dks cnyus dk dk;ZA dk;Z LFky dk fooj.k fufonk izi= esa lyXu gSA
Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 65 to 81
ACSR Rabbit Conductor
PCC Pole 8.5 mtr long
ACSR Weasel Conductor
Ms Channel (Dropper)100x50x2028mm
Ms Top Channel (125x65x2240mm)
11 Kv Disc Insulator T&C type 4500KN
11 KV Disc fitting
Ms Channel 125x65x1300mm (T-Off)
11 Kv Pin Insulator
11 Kv Pin with Nut
Stay Set Complete
Earthing of Pole By MS earthing Rod of 20x2500mm & 6swg earthing wire. Etc
LT ABC 3cx95 sqmm
11 Kv Fuse Set with Clamp
MS angle 75x75x6x2028mm with clamp & bolt and nut
11kv V-Type Cross arm
MS Angle Iron 65x65x6mm2700mm long
11KV XLPE Cable 3cx185sqmm
11KV OIT Door Jointing Kit 3cx185sqmm
Errection of above Centralised material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) ST - 11 Mtr Lone Pole, PCC 8.5 Mtr Long Pole and PCC 11 Mtr Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per RESPO. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole and Single Pole Structures (a) ST - 11 Mtr Lone Pole, PCC 8.5 Mtr Long Pole and PCC 11 Mtr Pole
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Road Restoration charges shall be inclusive in quoted rates. Single Pole and Double Pole (a) ST - 11 Mtr Lone Pole, PCC 8.5 Mtr Long Pole and PCC 11 Mtr Pole
Laying, Sagging strengthning and Re-Sagging of ACSR Rabbit Conductor with 3 or 4 parallel ways as per site requirement.
Laying and Fixing of ACSR Weasel Conductor for Jumpering as per site requirement.
Fixing of Ms Channel (Dropper)100x50x2028mm as per site requirement.
Fixing of Ms Top Channel (125x65x2240mm) as per site requirement.
Fixing of 11 Kv Disc Insulator T&C type 4500KN as per site requirement.
Fixing of 11 KV Disc fitting as per site requirement.
Fixing of Ms Channel 125x65x1300mm (T-Off) as per site requirement.
Fixing of 11 Kv Pin Insulator as per site requirement.
Fixing of 11 Kv Pin with Nut as per site requirement.
Fixing and Proper Grouting of Stay Set Complete as per site requirement.
Fixing of Earthing of Pole By MS earthing Rod of 20x2500mm & 6swg earthing wire. Etc as per site requirement.
Laying and Sagging of LT ABC 3cx95 sqmm as per site requirement.
Fixing of 11 Kv Fuse Set with Clamp as per site requirement.
Fixing of MS angle 75x75x6x2028mm with clamp & bolt and nut as per site requirement.
Fixing of 11kv V-Type Cross arm as per site requirement.
Fixing of MS Angle Iron 65x65x6mm2700mm long as per site requirement.
Laying of Fixing of 11KV XLPE Cable 3cx185sqmm as per site requirement.
Fixing and Making of 11KV OIT Door Jointing Kit 3cx185sqmm as per site requirement.
Dismentaling and Removal of Old & Jarjar Conductor and Cable from 23 Nos. Different work Site and Safe Carriage of its from work site to any store of PVVNL Discom including loading and unloading both ends.
Supply and Errection of below De-Centralised/Market material for completing the works as per RESPO. (Contractor will provide the material at his own cost.)
Supply and Fixing of Clamp With Nut & Bolt as per site requirement.
Supply and Fixing of Stone pad 300x300x75mm as per site requirement.
Supply and Fixing of Holding clamps for top channel Tpmo & fuse set etc with bolts & nuts as per site requirement.
Supply and Fixing of Danger Board Barbed wire G.I including Jumper as per site requirement.
Supply and Fixing of Dead End Clamp with I hook as per site requirement.
Supply and Fixing of Suspention Clamp with I hook as per site requirement.
Supply and Fixing of LT Piercing connector 95 Sq.mm as per site requirement.
Supply and Fixing of E-Bracket for 11kv as per site requirement.
Supply and Fixing of G.I Wire 6 SWG as per site requirement.
Supply and Fixing of G.I Wire 10 SWG for brasing as per site requirement.
Supply and Fixing of EYE Bolt as per site requirement.
Supply and Fixing of F Bracket for Fitting Top Insulator with Bolt & Nut as per site requirement.
Supply and Fixing of Danger Plate with clamp nut bolt as per site requirement.
Supply and Fixing of G.I Pipe6; Dia as per site requirement.
System Strengthing work in Block ABCGF in Sector 44, Noida (990 KVA Distribution Transformer Overhauling, Maintenance under EUDD - 3 Noida
Supply and Errection of below De-Centralised/Market material for completing the works as per RESPO. (Contractor will provide the material at his own cost.)
System Strengthing work in Block ABCGF in Sector 44, Noida under EUDD - III Noida 24 Nos. 990 KVA Distribution Transformer Overhauling, Maintenance, Replacement of Missing Parts, Paint of Pannel also Testing of 44 Nos. Distribution Syntax box, 18 Nos. Replacement damaged parts of LT HT Switchgears and other maintenance as per site requirement with complete work in all respect. Road Restoration work also done by the contractor. Safe Carriage of scrap material from work site to any store of PVVNL Discom including loading and unloading both ends. (All work in the scope of Contractor, work will be carried as per estimate, New Material shall be GTP Approved/Best quality ISI Marked)
M/s Shri Balaji Traders (BID ID -5574168)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .