Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹26.5 L+₹58,600.80 (2.26%)Rejected-Finance | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹29.1 L+₹3.2 L (12.4%)Rejected-Finance H NO 12 ADRASH SAINIK ENCLAVE HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L3 | Rejected-Finance Being L3 bidder |
Tender Value
₹28.0 L
EMD Value
₹56,000
Closing Date
16 Apr 2024, 6:00 pmClosed
GE (W)
GE (W) HISAR HISAR MIL STN PIN-125006
CA NO GE (W)/HSR-72/2023-24 REPAIR MAINTENANCE REPLACEMENT OF UNSERVICEABLE CI DI GI PIPE LINES AND CONNECTED ALLIED WORKS AT HISAR MIL STN UNDER GE (W) HISAR
2024_MES_642077_2
CA NO. GE (W)/HSR-72/2023-24
Open Tender
Pipe Laying Works
Item Rate
270 days
HISAR
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (W) HISAR
₹56,000
GE (W) HISAR
13 Jun 2024
26 Mar 2024
18 Apr 2024
26 Mar 2024
16 Apr 2024
2 Apr 2024
27 Mar 2024 - 1 Apr 2024
1 Apr 2024
Amount
Attending complaints of no water / leakage of water by removing float valve, water meter, stop cock etc or GI/composite tubing of size 15 mm to 20 mm bore upto 0.3 mtr length including all GI fittings like elbow, socket, Tee, Nipple, bend, union etc and making new threads as required at site including excavation,return refilling and removing soil & making good surface of disturbed foot paths, road cuttings with existig surface complete all as specified and directed.
Description all as per item No 1.00 above but of size 25 mm bore complete all as specified and directed.
Description all as per item No 1.00 above but of size 40 mm bore complete all as specified and directed.
Description all as per item No 1.00 above but of size 50 mm bore complete all as specified and directed.
Description all as per item No 1.00 above but of size 80 mm bore complete all as specified and directed.
Description all as per item No 1.00 above but of size 100 mm bore complete all as specified and directed. NOTE for Ser item No (01 to 6) : - (i) Dewatering of accumulated water using engine driven pump set etc is deemed to be included in quoted rate. (ii) Excavation and earth work includig quoted rate by Cotractor. (iii) Complaints of urgent nature will be attended round the clock including Sunday & holiday to restore the water supply. (iv) Minimum one Skilled pipe fitters and one Semi skilled pipe fitter for helper should be report at water suply service centre daily before 08.00 Hrs and will give feed back daily against that day complaints to JE at 17;00 Hrs. (v) Complaints given to contractor/contractor's rep shall be rectified within 24 hrs. (vi) A penality of Rs 500/- per complaint will be charged for not attending the complaints and completed within 48 hours. (vii) Contractor will arrange all the T&P/Diesel pumps for dewatering where ever required. (viii) Repeated Complaints should not be paid separately and if it will not rectified within during period given by JE, concern amount will be deducted from already paid amount against repeated complaints.
Attending leakage complaints of sluice valve 80 mm to 150 mm bore by opening /removing gland plate and taking out water from water pit , providing gland packings and refitting including replacing new one instead of worn out bolts,nuts,washers as required complete all as specified and directed.
Attending leakage complaints of sluice valve 200 mm to 250 mm bore by opening /removing gland plate and taking out water from water pit , providing gland packings and refitting including replacing new one instead of worn out bolts,nuts,washers as required complete all as specified and directed.
Attending leakage complaints of sluice valve 300 mm to 400 mm bore by opening /removing gland plate and taking out water from water pit , providing gland packings and refitting including replacing new one instead of worn out bolts,nuts,washers as required complete all as specified and directed. NOTE for Ser item No (7 to 9) : - (i) Dewatering of accumulated water using engine driven pump set etc is deemed to be included in quoted rate. (ii) Excavation and earth work required including quoted rate by contractor. (iii) Complaints of urgent nature will be attended round the clock including Sunday & holiday to restore the water supply. (iv) Minimum One Skilled pipe fitters and One Semi skilled pipe fitter for helper should be made available during all week days.. (v) Complaints given to contractor shall be rectified within 24 hrs. (vi) A penality of Rs 500/- per complaint will be charged for not attending the complaints and completed within 48 hours. (vii) Contractor will arrange all the T&P/Diesel pumps for dewatering where ever required. (viii) Repeated Complaints should not be paid separately and if it will not rectified within during period given by JE, concern amount will be deducted from already paid amount against repeated complaints.
Attending leakage complaints of CI/DI pipe lines size 80 to 100 mm bore using lead wool,rope, cocking, rubber gasket joints for DI in situ etc and making new CI/DI fittings as required at site including excavation,return refilling and removing soil & making good surface of disturbed foot paths, road cuttings with existig surface complete all as specified and directed.
Description all as per item No 10.00 above but size of 150 to 200 mm bore complete all as specified and directed.
Description all as per item No 10.00 above but size of 250 to 400 mm bore complete all as specified and directed. NOTE for Ser item No (10 to 12) : - (i) Dewatering of accumulated water using engine driven pump set etc is deemed to be included in quoted rate. (ii) Excavation and earth work required including quoted rate by contractor. (iii) Complaints of urgent nature will be attended round the clock including Sunday & holiday to restore the water supply. (iv) Minimum One Skilled pipe fitters and One Semi skilled pipe fitter for helper should be made available during all week days.. (v) Complaints given to contractor/contractor's rep shall be rectified within 24 hrs. (vi) A penality of Rs 1000/- per complaint will be charged for not attending the complaints and completed within 48 hours. (vii) Contractor will arrange all the T&P/Diesel pumps for dewatering where ever required. (viii) Repeated Complaints should not be paid separately and if it will not rectified within during period given by JE, concern amount will be deducted from already paid amount against repeated complaints.
Taking up or down steel tubing and connections 15 mm bore complete all as specified and directed.
Description all as per item No 13.00 above but of size 20 mm bore complete all as specified and directed.
Description all as per item No 13.00 above but of size 25 mm bore complete all as specified and directed.
Description all as per item No 13.00 above but of size 40 mm bore complete all as specified and directed.
Description all as per item No 13.00 above but of size 50 mm bore complete all as specified and directed.
Description all as per item No 13.00 above but of size 80 mm bore complete all as specified and directed.
Description all as per item No 13.00 above but of size 100 mm bore complete all as specified and directed.
Supply and fixing Steel water tubes, medium grade, ISI marked, galvanised, 15mm bore with all fittings, Tee, Socket, Union, flange and Socket laid in trenches/ on walls and making good surface of disturbed foot paths, road cuttings with existig surface complete all as specified and directed complete all as specified and directed.
Description all as per item No 20.00 above but of size 20 mm bore complete all as specified and directed.
Description all as per item No 20.00 above but of size 25 mm bore complete all as specified and directed.
Description all as per item No 20.00 above but of size 40 mm bore complete all as specified and directed.
Description all as per item No 20.00 above but of size 50 mm bore complete all as specified and directed.
Description all as per item No 20.00 above but of size 80 mm bore complete all as specified and directed.
Description all as per item No 20.00 above but of size 100 mm bore complete all as specified and directed.
Taking up cast iron/Ductile Iron water mains (including all fittings) 80mm bore, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Description all as per item No 27.00 above but of size 100 mm bore complete all as specified and directed.
Description all as per item No 27.00 above but of size 150 mm bore complete all as specified and directed.
Description all as per item No 27.00 above but of size 200 mm bore complete all as specified and directed.
Description all as per item No 27.00 above but of size 250 mm bore complete all as specified and directed.
Description all as per item No 27.00 above but of size 300 mm bore complete all as specified and directed.
Description all as per item No 27.00 above but of size 400 mm bore complete all as specified and directed.
Supply and fixing Cast iron pipes 80mm bore with spigot and socket ends, centrifugally cast, class LA, in any length, laid in trenches and making good surface of disturbed foot paths, road cuttings with existig surface complete all as specified and directed complete all as specified and directed.
Description all as per item No 34.00 above but of size 100 mm bore complete all as specified and directed.
Description all as per item No 34.00 above but of size 150 mm bore complete all as specified and directed.
Description all as per item No 34.00 above but of size 200 mm bore complete all as specified and directed.
Description all as per item No 34.00 above but of size 250 mm bore complete all as specified and directed.
Description all as per item No 34.00 above but of size 300 mm bore complete all as specified and directed.
Description all as per item No 34.00 above but of size 400 mm bore complete all as specified and directed.
Laying only in trenches and making good surface of disturbed foot paths, road cuttings with existig surface of old cast iron pipes with spigot and socket ends centrifugally cast in any length, 80mm bore complete all as specified and directed. Note :- CI pipe shall be issued free for fixing under Schedule 'B'.
Description all as per item No 41.00 above but of size 100 mm bore complete all as specified and directed.
Description all as per item No 41.00 above but of size 150 mm bore complete all as specified and directed.
Description all as per item No 41.00 above but of size 200 mm bore complete all as specified and directed.
Description all as per item No 41.00 above but of size 250 mm bore complete all as specified and directed.
Description all as per item No 41.00 above but of size 300 mm bore complete all as specified and directed.
Description all as per item No 41.00 above but of size 400 mm bore complete all as specified and directed.
Cutting of 80 mm bore existing CI /DI Pipe for taking up of damaged / leakage portion or for insertion of branch T etc complete all as specified and directed. (Both cut shall be measured as one Job)
Description all as per item No 48.00 above but of size 100 mm bore complete all as specified and directed.
Description all as per item No 48.00 above but of size 150 mm bore complete all as specified and directed.
Description all as per item No 48.00 above but of size 200 mm bore complete all as specified and directed.
Description all as per item No 48.00 above but of size 250 mm bore complete all as specified and directed.
Description all as per item No 48.00 above but of size 300 mm bore complete all as specified and directed.
Supply and Fixing Tee,cross,reducer,sockets, spigots, caps, plugs,Bends/duck foot Bends (angle/radius), Bell mouth/Tail pieces pieces, flange, Mechaical Joint collar, detachable Joints, "Y" Junction, Straight, Tappers for spigot socket pipes size of up to 150mm size as required at site complete all as specified and directed.
Supply and Fixing Tee,cross,reducer,sockets, spigots, caps, plugs,Bends/duck foot Bends (angle/radius), Bell mouth/Tail pieces pieces, flange, Mechaical Joint collar, detachable Joints, "Y" Junction, Straight, Tappers for spigot socket pipes size of 200 to 300mm size as required at site complete all as specified and directed.
Burning out lead joint in position for 80 mm bore pipes and fittings complete all as specified and directed. Note :- For old lead will be reuse , if excess qunatites of New lead will be required rate of the same deemed to included in Quoted rate.
Description all as per item No. 56.00 above but of size 100 mm bore complete all as specified and directed.
Description all as per item No. 56.00 above but of size 150 mm bore complete all as specified and directed.
Description all as per item No. 56.00 above but of size 200 mm bore complete all as specified and directed.
Description all as per item No. 56.00 above but of size 250 mm bore complete all as specified and directed.
Description all as per item No. 56.00 above but of size 300 mm bore complete all as specified and directed.
M & L for Run lead joint for cast iron spigot and socket pipes and fitting of 80mm bore complete all as specified and directed.
Description all as per item No. 62.00 above but of size 100 mm bore complete all as specified and directed.
Description all as per item No. 62.00 above but of size 150 mm bore complete all as specified and directed.
Description all as per item No. 62.00 above but of size 200 mm bore complete all as specified and directed.
Description all as per item No. 62.00 above but of size 250 mm bore complete all as specified and directed.
Description all as per item No. 62.00 above but of size 300 mm bore complete all as specified and directed.
Description all as per item No. 62.00 above but of size 400 mm bore complete all as specified and directed.
Supply and fix in repair Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 15 mm bore complete all as specified and directed.
Description all as per item No. 69.00 above but of size 20 mm bore complete all as specified and directed.
Description all as per item No. 69.00 above but of size 25 mm bore complete all as specified and directed.
Description all as per item No. 69.00 above but of size 40 mm bore complete all as specified and directed.
Description all as per item No. 69.00 above but of size 50 mm bore complete all as specified and directed.
Repair to non return valve 80mm to 150mm bore by opening nuts, bolts and washer and replacing flap/gasket with new flap/gasket, refixing the nuts, bolts and washers etc. New Nuts, bolts and washers if required including in this rarte only complete all as specified and directed
Repair to non return valve 200mm to 250mm bore by opening nuts, bolts and washer and replacing flap/gasket with new flap/gasket, refixing the nuts, bolts and washers etc. New Nuts, bolts and washers if required including in this rarte only complete all as specified and directed
Repair to non return valve 300 mm to 400mm bore by opening nuts, bolts and washer and replacing flap/gasket with new flap/gasket, refixing the nuts, bolts and washers etc. New Nuts, bolts and washers if required including in this rarte only complete all as specified and directed
Supply and Fixing Tee,cross,reducer,sockets, spigots, caps, plugs,Bends/duck foot Bends (angle/radius), Bell mouth/Tail pieces pieces, flange, Mechaical Joint collar, detachable Joints, "Y" Junction, Straight, Tappers for spigot socket pipes size of up to 150mm size as required at site complete all as specified and directed.
Supply and Fixing Tee,cross,reducer,sockets, spigots, caps, plugs,Bends/duck foot Bends (angle/radius), Bell mouth/Tail pieces pieces, flange, Mechaical Joint collar, detachable Joints, "Y" Junction, Straight, Tappers for spigot socket pipes size of 200 to 300mm size as required at site complete all as specified and directed.
M&L for flanged joint with rubber or fibre board gasket of CI/DI pipes, sluice valves, non return valves etc of 80mm bore fixed in repair/replacement complete.(Flange and nut,bolts and wsaher will be measured and paid seperately)
All as per item No 79.00 but of 100mm bore complete all as specified and directed.
All as per item No 79.00 but of 150mm bore complete all as specified and directed.
All as per item No 79.00 but of 200mm bore complete all as specified and directed.
All as per item No 79.00 but of 250mm bore complete all as specified and directed.
All as per item No 79.00 but of 300mm bore complete all as specified and directed.
Supply and fixing Sluice valves class P N 1.6 cast iron body with forged steel spindle, non rising type, with cast iron wheel head, both end flanged, ISI marked, 300 mm bore including neoprene rubber gasket, nuts, bolts, washers, etc fixed in repairs/replacement complete all as specified and directed.
Description all as per item No. 85.00 above here-in-before but 250 bore complete all as specified and directed.
Description all as per item No. 85.00 above here-in-before but 200 bore complete all as specified and directed.
Description all as per item No. 85.00 above here-in-before but 150 bore complete all as specified and directed.
Description all as per item No. 85.00 above here-in-before but 100 bore complete all as specified and directed.
Description all as per item No. 85.00 above here-in-before but 80 bore complete all as specified and directed.
M&L SS spindle with check nut of sluice valve 80 mm bore as per existing pattern, fixed in repairs/replacement including nuts, bolts & washers complete all as specified and directed.
Description all as per item No. 91.00 above but for sluice valve 100 mm bore complete all as specified and directed.
Description all as per item No. 91.00 above but for sluice valve 150 mm bore complete all as specified and directed.
Description all as per item No. 91.00 above but for sluice valve 200mm bore complete all as specified and directed.
Description all as per item No. 91.00 above but for sluice valve 250mm bore complete all as specified and directed.
Description all as per item No. 91.00 above but for sluice valve 300mm bore complete all as specified and directed.
Excavating in trenches, not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5mt in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5mtr wide and not exceeding 1.5mt in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5mtr in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5mrt wide and not exceeding 1.5mt in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5mt in depth for shafts, cesspits, manholes, pier holes, etc and getting out in mud complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50mt and depositing where directed at a level not exceeding 1.5mt above the starting point complete all as specified and directed.
S&F in replacement of any size of sluice valve operating rod made of GI pipe heavy duty 20 mm bore, 1.5 mtr to 4 mtr long as per ground requirement duly fixed on sluice valve at one end welded with sluice valve cap , at other end with handle complete all as specified and directed.
S&F MS clamp of any size including drilling holes complete all as specified and directed.
Disconnecting and taking down from 80 mm bore existing unserviceable sluice valves refacing, regrinding and refixing including flanged joints fittings Nut & Bolts and removing from site complete all as specified and directed.
Description all as per item No. 104.00 here-in-before but size of sluice valve 100 mm bore complete all as specified and directed.
Description all as per item No. 104.00 here-in-before but size of sluice valve 150 mm bore complete all as specified and directed.
Description all as per item No. 104.00 here-in-before but size of sluice valve 200 mm bore complete all as specified and directed.
Description all as per item No. 104.00 here-in-before but size of sluice valve 250 mm bore complete all as specified and directed.
Description all as per item No. 104.00 here-in-before but size of sluice valve 300 mm bore complete all as specified and directed.
Demolition of brick work built in cement mortar including all arches, pillars etc and removal of brick bats from site and rubbish to a distance n.exc 100 mtr complete all as specified and directed.
M&L brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius using old size bricks in cement mortar 1:4 for supports to pipes and repair to valve chambers complete all as specified and directed.
Demolition of cement concrete (un reinforced) as in foundation not exc 15cm thick(below or above ground level) of old foundation of valve chambers and coping etc and removal of rubbish to a distance n.exc 100mtre complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B-2 using 40mm graded mechanically crushed stone aggregate 100mm thick as in road cutting including necessary form work & finishing the surface even and smooth without using extra cement complete all as specified and directed .
M&L plain cement concrete 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregate as in foundation including necessary form work complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in coping including necessary form work & finishing the surface even and smooth without using extra cement complete all as specified and directed .
M&L plastering 10mm thick in cement mortar 1:4 on brick or concrete walls of any description, surfaces finishing surfaces even and smooth without using extra cement complete all as specified and directed.
Taking out unserviceable mild steel covers of valve chambers and supply and fixing covers suitable for existing valve chambers duly hinged fabricating the frame by using 3.15mm thick mild steel sheet and angle iron of size 40 mm X 40 mm X 6 mm thick including making locking arrangement and fixing the above cover in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate and providing hold fast of appropriate size made to shape of 50mm x 6mm mild steel flat including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L construction of brick masonry valve pit of size 1500 mm X 1500 mm X 1250 mm (internal dimensions of chamber) depth to be reckoned from the top of PCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 X 40 X 6 mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr 15 cm thick PCC 1:4:8 type D-2 in PCC foundation projected by 15cm all round from the outer face of brick wall PCC 1:2:4 type B-1 in coping complete all as specified and directed.
Description all as per item No. 118.00 here-in-before but internal size of valve pit 1200 mm X 1200mm X 1200 mm complete all as specified and directed.
Description all as per item No. 118.00 here-in-before but internal size of valve pit 900 mm X 900 mm X 900 mm complete all as specified and directed.
YASHU CONTRACTORS
virendra constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .