| 1 | L1₹10.7 LAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.8 L+₹1.5 L (13.7%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹13.3 L+₹2.0 L (18.1%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L3 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | PSK Enterprises L3 | muthu constructions L1 | RK ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Servicing/ Inspection of water cooler of any cap/type/make installed at different units at DGQA area Avadi on site including disconnecting electric and water connection of water cooler finding of defect including dismantling of compressor, relay, capacitor, thermostat, motor, PVC hose pipe, condensing coil including fixing new spares complete as required all as specified and directed by Engineer -in-charge.
Note
(i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items.
(ii) All T&P charges for carrying the water cooler from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates.
(iii) Repair/Replacement of minor items whose cost are less than 100/- Rupees is deemed to be included in the quoted rate.
(iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring, ,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.
(v) All the material will be procured by the contractor in advance and deposite in MES store for replacement. material directly replaced by the contractor will not be paid. | 20 | Each Job | 980 ₹19,600 | 800 ₹16,000 | 500 ₹10,000 Lowest |
| 2.00 | Supply and fixing Hermetic compressor unit for water cooler of 40/80 ltr Complete all as specified and as directed by Engr-in-Charge. | 1 | Each | 7,100 ₹7,100 | 7,000 ₹7,000 Lowest | 10,000 ₹10,000 |
| 3.00 | Supply and fixing Hermetic compressor unit for water cooler of 60/120 ltr cap Complete all as specified and as directed by Engr-in-Charge. | 2 | Each | 10,700 ₹21,400 | 8,000 ₹16,000 Lowest | 12,000 ₹24,000 |
| 4.00 | Supply and fixing Hermetic compressor unit for water cooler of 150 ltr cap Complete all as specified and as directed by Engr-in-Charge. | 2 | Each | 13,400 ₹26,800 | 9,000 ₹18,000 Lowest | 15,000 ₹30,000 |
| 5.00 | Supply and fixing starting relay CAJ-2612 Complete all as specified and as directed by Engr-in-Charge. | 3 | Each | 440 ₹1,320 | 350 ₹1,050 Lowest | 500 ₹1,500 |
| 6.00 | Supply and fixing over load protection relay suitable for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge. | 6 | Each | 440 ₹2,640 | 300 ₹1,800 Lowest | 500 ₹3,000 |
| 7.00 | Supply and fixing starting capacitor 40-80 Mfd for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge. | 4 | Each | 180 ₹720 Lowest | 500 ₹2,000 | 500 ₹2,000 |
| 8.00 | Supply and fixing starting capacitor 100-120 Mfd for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge. | 4 | Each | 206 ₹824 Lowest | 500 ₹2,000 | 500 ₹2,000 |
| 9.00 | Supply and fixing thermostat suitable for any cap water cooler Complete all as specified and as directed by Engr-in-Charge. | 8 | Each | 260 ₹2,080 Lowest | 400 ₹3,200 | 500 ₹4,000 |
| 10.00 | Supply and fixing fan motor of capacity 1/10 to 1/35 HP 50c/s, 230 volts Complete all as specified and as directed by Engr-in-Charge. | 6 | Each | 3,800 ₹22,800 | 2,500 ₹15,000 Lowest | 4,000 ₹24,000 |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
26 Jan 2026, 6:00 pmClosed
Garrison Engineer, Avadi
GE Avadi
REPAIR / MAINT OF WINDOW / SPLIT AC AND COOLING APPLIANCE FOR BLDG NO P1, P8, P12 AND P20 AT DGQA AREA UNDER GE AVADI
2026_MES_748440_1
8366/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Avadi
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Avadi
₹15,000
Yes
11 Mar 2026
14 Jan 2026
28 Jan 2026
14 Jan 2026
26 Jan 2026
20 Jan 2026
14 Jan 2026 - 18 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Servicing/ Inspection of water cooler of any cap/type/make installed at different units at DGQA area Avadi on site including disconnecting electric and water connection of water cooler finding of defect including dismantling of compressor, relay, capacitor, thermostat, motor, PVC hose pipe, condensing coil including fixing new spares complete as required all as specified and directed by Engineer -in-charge.
Note
(i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items.
(ii) All T&P charges for carrying the water cooler from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates.
(iii) Repair/Replacement of minor items whose cost are less than 100/- Rupees is deemed to be included in the quoted rate.
(iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring, ,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.
(v) All the material will be procured by the contractor in advance and deposite in MES store for replacement. material directly replaced by the contractor will not be paid. | 20 | Each Job | - | - |
| 2 | Supply and fixing Hermetic compressor unit for water cooler of 40/80 ltr Complete all as specified and as directed by Engr-in-Charge. | 1 | Each | - | - |
| 3 | Supply and fixing Hermetic compressor unit for water cooler of 60/120 ltr cap Complete all as specified and as directed by Engr-in-Charge. | 2 | Each | - | - |
| 4 | Supply and fixing Hermetic compressor unit for water cooler of 150 ltr cap Complete all as specified and as directed by Engr-in-Charge. | 2 | Each | - | - |
| 5 | Supply and fixing starting relay CAJ-2612 Complete all as specified and as directed by Engr-in-Charge. | 3 | Each | - | - |
| 6 | Supply and fixing over load protection relay suitable for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge. | 6 | Each | - | - |
| 7 | Supply and fixing starting capacitor 40-80 Mfd for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge. | 4 | Each | - | - |
| 8 | Supply and fixing starting capacitor 100-120 Mfd for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge. | 4 | Each | - | - |
| 9 | Supply and fixing thermostat suitable for any cap water cooler Complete all as specified and as directed by Engr-in-Charge. | 8 | Each | - | - |
| 10 | Supply and fixing fan motor of capacity 1/10 to 1/35 HP 50c/s, 230 volts Complete all as specified and as directed by Engr-in-Charge. | 6 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
8366Tenderdocument.pdf
Tender Documents • 0.77 MB
BOQ_838172.xls
BOQ • 1.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .