| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L1 | Accepted-AOC AOC_Issued | |
| 2 | L2₹9.7 L+₹18,332 (1.93%)Rejected-Finance BIDHAN MARKET BARASAT | BARASAT | L2 | Rejected-Finance That the bid is not L1 | |
| 3 | L3₹9.9 L+₹41,096 (4.33%)Rejected-Finance 1260 GANGAPUR GROUND FLOOR MANDIRTALA DUTTAPUKUR NORTH 24 PARGANAS WEST BENGAL 743248 | 24 PARAGANAS NORTH | WEST BENGAL | 743248 | L3 | Rejected-Finance That the bid is not L1 | |
| 4 | L4₹10.9 L+₹1.4 L (14.8%)Rejected-Finance | L4 | Rejected-Finance That the bid is not L1 |
| Sl No | Description | Qty | Unit | TECHNO FAITH L2 | S D ENTERPRISE L3 | R.N.ROY ELECTRICAL CONTRACTOR L4 | M/S R. K. ENTERPRISE L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of depleted electrical installations including VTPNDB, HTPNDBs, SPNDBs and shifting the same to the dedicated section office within range of 5 km. | 1 | Job | 3,000 ₹3,000 | 2,442 ₹2,442 Lowest | 2,886 ₹2,886 | 4,000 ₹4,000 |
| 2.00Supply and installation of CPRI approved Floor Mounted L.T. cubical type fully compartmentalized distribution panel of min. size 1500 x 1000 x 250} mm, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each compartment with 40 x 40x 6 mm angle iron). The base of panel should be made with 75mm x 40mm x 4. 4 mm M.S. channel. Each compartment will be providing with hylum board at back side. |Main LT Panel board}. Construction Details | |||||||
| 2.10All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical tit{s bar chambers is to properly arrange and all electrical equi}iiiients are to be fixed by nuts and bolts on suitable Hylum board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection | |||||||
| 2.20Incoming Arrangement : a) 415 V, 250 A 4(four} pole Open Execution type TPN SFU on flat iron/angle iron frame with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating (Make —ABB / SIEMENS/ L-K )- 1no. Bus bar section : 4 15V, 250 Amp capacity 99.9% — 99.5% electrolytic tinned 4 bar copper bus bar {cross section size of min. 120 sq. mm.] mounted on non-hygroscopic porcelain insulator / hylum sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification | |||||||
| 2.30The busbar is to be rigidly supported on suitable non- hygroscopic Insulating matoTials of robust ration to with stand electromecliariical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications. Bus bar should be distributed in such a way that total loads can be evenly distributed on both sides of LT incomer panels as per direction of EIC. | |||||||
| 2.40Outgoing Arrangement : 415 V, 125 A Open Execution type TPN SFU on flat iron/ angle iron frame with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating (Make -ABB /SIEMENS / Legrand) - 4 nos. 415 V, 63 A Open Execution type TPN SFU on flat iron / angle iron frame with nuts bolts etc incl. S & F 3 nos. DIN type HRC fiise as per rating (Make —ABB /SIEMENS/ Legrand) -2 nos. E.I. Danger Board of suitable size- 1 no. Metering Panel 3 P Ammeter Make- Multispan CI 1 WL13 1010OOOO 3 P Voltmeter Make- Multispan CI 1 WL132010OOOO | |||||||
| 2.50LED Indicating Lamp Set (Red, Yellow, Blue) Make- Gennext EPLR/Y/ B240A CT 415/5 A Make- Secure 250/5 - 3 nos. Interconnection :- All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper & with maintaining Proper color code with proper socketing of the end of each wire leads. Also the main Bus bar to be extended to outgoing feeders on two side of bus coupler panel (as per direction of EIC). | |||||||
| 2.60 | The complete panel Board is to be spray painted after required surface treatment by & tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :-
The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C. | 1 | Ea. | 78,673 ₹78,673 Lowest | 1,25,000 ₹1,25,000 | 1,75,000 ₹1,75,000 | 1,20,000 ₹1,20,000 |
| 3.00 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish
Average run 8 mtr | 156 | Pt. | 849 ₹1,32,444 | 870 ₹1,35,720 | 1,000 ₹1,56,000 | 630 ₹98,280 Lowest |
| 3.10 | Average run 10 mtr | 54 | Pt. | 1,007 ₹54,378 | 950 ₹51,300 | 1,100 ₹59,400 | 745 ₹40,230 Lowest |
Tender Value
₹11.2 L
EMD Value
₹22,360
Closing Date
13 Feb 2026, 1:00 pmClosed
EEI,KNHED, PW Dte
THE EXECUTIVE ENGINEER, P.W.D /KOLKATA NORTH HEALTH ELECTRICAL DIVISION
Renovation and Remodelling of Electrical installations of the Administrative building at J.B.Roy S.A.M.C.H. Shyambazar
2026_WBPWD_991851_1
WBPWD/EE/KNHED/e-NIQ-74/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹22,360
Office of the EE, KNHED,PW Dte
30 Sept 2026
20 Jan 2026
16 Feb 2026
20 Jan 2026
13 Feb 2026
31 Jan 2026
30 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of depleted electrical installations including VTPNDB, HTPNDBs, SPNDBs and shifting the same to the dedicated section office within range of 5 km. | 1 | Job | - | - |
| 2Supply and installation of CPRI approved Floor Mounted L.T. cubical type fully compartmentalized distribution panel of min. size 1500 x 1000 x 250} mm, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each compartment with 40 x 40x 6 mm angle iron). The base of panel should be made with 75mm x 40mm x 4. 4 mm M.S. channel. Each compartment will be providing with hylum board at back side. |Main LT Panel board}. Construction Details | |||||
| 2.1 | All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in
such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical tit{s bar chambers is to properly arrange and all electrical equi}iiiients are to be fixed by nuts and bolts on suitable Hylum board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection | - | - | - | - |
| 2.2 | Incoming Arrangement :
a) 415 V, 250 A 4(four} pole Open Execution type TPN SFU on flat iron/angle iron frame with nuts bolts etc incl. S & F 3 nos. DIN type HRC
fuse as per rating (Make —ABB / SIEMENS/ L-K )- 1no.
Bus bar section :
4 15V, 250 Amp capacity 99.9% — 99.5% electrolytic tinned 4 bar copper bus bar {cross section size of min. 120 sq. mm.] mounted on non-hygroscopic porcelain insulator / hylum sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification | - | - | - | - |
| 2.3 | The busbar is to be rigidly supported on suitable non- hygroscopic Insulating matoTials of robust ration to with stand electromecliariical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications. Bus bar should be distributed in such a way that total loads can be evenly distributed on both sides of LT incomer panels as per direction of EIC. | - | - | - | - |
| 2.4 | Outgoing Arrangement :
415 V, 125 A Open Execution type TPN SFU on flat iron/ angle iron frame with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating (Make -ABB /SIEMENS / Legrand) - 4 nos.
415 V, 63 A Open Execution type TPN SFU on flat iron / angle iron frame with nuts bolts etc incl. S & F 3 nos. DIN type
HRC fiise as per rating (Make —ABB /SIEMENS/ Legrand) -2 nos.
E.I. Danger Board of suitable size- 1 no.
Metering Panel
3 P Ammeter Make- Multispan CI 1 WL13 1010OOOO
3 P Voltmeter Make- Multispan CI 1 WL132010OOOO | - | - | - | - |
| 2.5 | LED Indicating Lamp Set (Red, Yellow, Blue) Make- Gennext EPLR/Y/ B240A
CT 415/5 A Make- Secure 250/5 - 3 nos.
Interconnection :-
All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper & with maintaining Proper color code with proper socketing of the end of each wire leads. Also the main Bus bar to be extended to outgoing feeders on two side of bus coupler panel (as per direction of EIC). | - | - | - | - |
| 2.6 | The complete panel Board is to be spray painted after required surface treatment by & tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :-
The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C. | 1 | Ea. | - | - |
| 3 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish
Average run 8 mtr | 156 | Pt. | - | - |
| 3.1 | Average run 10 mtr | 54 | Pt. | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_2425043.xls
BOQ • 0.43 MB
2911.pdf
Tender Documents • 0.50 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .