Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L1₹24.6 LRejected-Finance | L1 | Rejected-Finance Other Than Lowest | |
| 3 | L3₹24.7 LRejected-Finance | L3 | Rejected-Finance Other Than Lowest | |
| 4 | L4₹24.7 LRejected-Finance | L4 | Rejected-Finance Other Than Lowest | |
| 5 | L5₹24.8 LRejected-Finance | L5 | Rejected-Finance Other Than Lowest |
| Sl No | Description | Qty | Unit | GEE EMM ASSOCIATES L3 | M/s. M Company L6 | ESS KAY BUILDER L2 | RAJ KAMAL BUILDERS L5 | J S S BUILDERS & ENGINEERS L1 | m/s inder construction co L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of roof brick tiles fixed in cement mortar in single layer ; Complete all as specified and directed. | 1,625 | Square Metre | 25 ₹40,625 | 10 ₹16,250 Lowest | 30 ₹48,750 | 10 ₹16,250 Lowest | 35 ₹56,875 | 20 ₹32,500 |
| 2.00 | Demolition mud phuska in roofs any thickness including plastering and leeping, removing debris and rubbish from the site Complete all as specified and directed. | 130 | Cubic Metre | 280 ₹36,400 | 300 ₹39,000 | 100 ₹13,000 Lowest | 100 ₹13,000 Lowest | 250 ₹32,500 | 200 ₹26,000 |
| 3.00 | Material and Labour for Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in roof padding (average 40mm thick), roof kerbs or mud stops, rounded or chamfered on edge ; Complete all as specified and directed. | 81.25 | Cubic Metre | 5,300 ₹4,30,625 | 5,000 ₹4,06,250 | 6,000 ₹4,87,500 | 4,500 ₹3,65,625 | 4,000 ₹3,25,000 Lowest | 4,800 ₹3,90,000 |
| 4.00 | Material and labour for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application over a tack coat of industrial bitumen 85/25 at the rate of 1.6 kg per sq.m including cleaning surfaces and including 10 mm thick 1: 4 cement plaster on padding surface ; Complete all as specified and directed. | 1,645 | Square Metre | 380 ₹6,25,100 | 400 ₹6,58,000 | 400 ₹6,58,000 | 425 ₹6,99,125 | 330 ₹5,42,850 Lowest | 425 ₹6,99,125 |
| 5.00 | Material and labour for 40 mm thick brick tiles laid over and including 15mm thick bedding layer in cement mortar 1:6 and jointed, grouted and flush pointing as work proceed in CM 1:3 complete all as specified. | 280 | sqm | 300 ₹84,000 Lowest | 390 ₹1,09,200 | 370 ₹1,03,600 | 550 ₹1,54,000 | 475 ₹1,33,000 | 300 ₹84,000 Lowest |
| 6.00 | All as per Srl item above here-in-before but except tiles.Note : (i) Serviceable brick tiles obtained from shall be reused. | 1,345 | sqm | 300 ₹4,03,500 | 370 ₹4,97,650 | 210 ₹2,82,450 Lowest | 270 ₹3,63,150 | 260 ₹3,49,700 | 260 ₹3,49,700 |
| 7.00 | Taking down cement plaster on brick, concrete or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. of any description , removing debris and rubbish from the site ; Complete all as specified and directed. | 880 | Square Metre | 25 ₹22,000 | 20 ₹17,600 Lowest | 45 ₹39,600 | 50 ₹44,000 | 20 ₹17,600 Lowest | 25 ₹22,000 |
| 8.00 | Material and Labour for 12mm thick cement plastering in cm 1:6 on brick or concrete surfaces other than fair surface, finished the surfaces even and fair without using extra cement ; Complete all as specified and directed. | 280 | Square Metre | 230 ₹64,400 | 200 ₹56,000 | 260 ₹72,800 | 175 ₹49,000 Lowest | 200 ₹56,000 | 200 ₹56,000 |
| 9.00 | Material and Labour for 5 mm thick cement plastering in CM 1:3 on ceiling surfaces other than fair surface, finished the surfaces even and fair without using extra cement ; Complete all as specified and directed. | 150 | Square Metre | 220 ₹33,000 | 200 ₹30,000 | 300 ₹45,000 | 175 ₹26,250 Lowest | 180 ₹27,000 | 200 ₹30,000 |
| 10.00 | Material and Labour for Rendering 15 mm thick on fair/unfair faces of brick work or concrete surfaces in CM 1:4 and to be finished even and smooth ( without using extra lime or cement) Complete all as specified | 450 | Square Metre | 240 ₹1,08,000 | 200 ₹90,000 | 270 ₹1,21,500 | 180 ₹81,000 Lowest | 200 ₹90,000 | 220 ₹99,000 |
Tender Value
₹35.0 L
EMD Value
₹70,060
Closing Date
28 Aug 2025, 6:00 pmClosed
GE Amritsar
GARRISON ENGINEER AMRITSAR CANTT PIN 143001
SPL REPAIR TO ROOF TREATMENT OF BLDG NO P-23 MT OFFICE GD ROOM P-27 MT SHED AND P34 QTR GD OTM ACCN OF 908 MED REGT AT OLD AMRITSAR CANTT
2025_MES_723611_1
GE/ASR-46/2025-26
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS D CATEGORY a i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹70,060
1 Jan 2026
31 Jul 2025
4 Sept 2025
31 Jul 2025
28 Aug 2025
14 Aug 2025
31 Jul 2025 - 7 Aug 2025
Amount
Dismantling of roof brick tiles fixed in cement mortar in single layer ; Complete all as specified and directed.
Demolition mud phuska in roofs any thickness including plastering and leeping, removing debris and rubbish from the site Complete all as specified and directed.
Material and Labour for Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in roof padding (average 40mm thick), roof kerbs or mud stops, rounded or chamfered on edge ; Complete all as specified and directed.
Material and labour for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application over a tack coat of industrial bitumen 85/25 at the rate of 1.6 kg per sq.m including cleaning surfaces and including 10 mm thick 1: 4 cement plaster on padding surface ; Complete all as specified and directed.
Material and labour for 40 mm thick brick tiles laid over and including 15mm thick bedding layer in cement mortar 1:6 and jointed, grouted and flush pointing as work proceed in CM 1:3 complete all as specified.
All as per Srl item above here-in-before but except tiles.Note : (i) Serviceable brick tiles obtained from shall be reused.
Taking down cement plaster on brick, concrete or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. of any description , removing debris and rubbish from the site ; Complete all as specified and directed.
Material and Labour for 12mm thick cement plastering in cm 1:6 on brick or concrete surfaces other than fair surface, finished the surfaces even and fair without using extra cement ; Complete all as specified and directed.
Material and Labour for 5 mm thick cement plastering in CM 1:3 on ceiling surfaces other than fair surface, finished the surfaces even and fair without using extra cement ; Complete all as specified and directed.
Material and Labour for Rendering 15 mm thick on fair/unfair faces of brick work or concrete surfaces in CM 1:4 and to be finished even and smooth ( without using extra lime or cement) Complete all as specified
M&L for Preparing of new plastered surface and applying two coats cement base paints on walls complete as specified
M&L for preparation of old decorated brick/ concrete plastered or unplastered surfaces of walls, pillars,cornices by Brooming down etc and applying one coats of cement base paint on walls, pillars, cornices etc complete all as specified & directed.
M&L for Preparing of new plastered surface and applying two coats white wash on walls complete as specified
M&L for Preparing of Old plastered surface and applying one coats white wash on walls complete as specified
Material and Labour for preparation of new plaster surface and applying two coat of white wash on ceiling ; Complete all as specified and directed.
Material and Labour for one coat of white wash on old treated plastered surface on ceiling of undecorated surfaces ; Complete all as specified and directed.
Demolition of cement concrete in ground floor & paving n.exc 15cm above ground level ; Complete all as specified and directed.
Material and Labour 75mm thick PCC 1:3:6 type C 2 as in plinth protection finishing the surface even and fair with out using extra cement laid to a slope of 1 to 20. It shall be laid in alternate bays, each bay not exceeding 3 m in length with joint to be filled with bituminous mastic filling comprising of misture of one part of heated not blown bitumen 85/25 penetration and three parts of heated sand all as directed by Engineer-In-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc.complete all as directed NOTE: Cost of unserviceable materials will be charged from the contractor against Schedule of Credit.
Taking down carefully existing serviceable Ceiling fan/Wall mounted fan, ceiling cable,exhaust fan, ceiling end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose or connector to fan complete all as directed
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through existing metallic/rigid PVC concealed conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as directed
(a) Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push.
(b) One socket outet point 5 amps on the same board.
(c) One socket outet point 5 amps on the independent board.
All as Ser item 3 here in before but with 2.5 sq mm wire and earth wire of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet.
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid new PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as directed
(a) One light point/Bell/Fan point controlled by one switch.
(b) One 3 pin 5 Amps socket outlet on independent board.
(c) One 5 Amps outlet point on same board with other switches/sockets
All as per ser item No 5 here in above but point wiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board.(i) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for nuetral and green for earth wire.(ii) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates.(iii) Modular fittings/fixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item.
Supply and fixing modular switch 1 way 6A, 240 volts, 1 module complete all as specified and directed
Supply and fixing modular socket, 6A, 240 volts, 2/3 pin combined 2 module, flush type all as specified and directed
Supply and fixing modular switch 1 way 16A, 240 volts, 1 module complete all as specified and directed
Supply and fixing modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type all as specified and directed
Supply and fixing modular fan step regulator, 2 module, 240 Volts, 50 Hz, suitable for ceiling fan all as directed
Supply and fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65 x 50 mm three terminal, 240 volts, AC single phase complete all as specified
Supply and fixing LED lights fitting 1x 20W, 220V, AC, 6500K, decorative box type with driver, double sided connection, LED tube light connecting up with 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose complete all as specified and directed.
Supply and fixing Air fresh fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 300 mm complete fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to exhaust fan and writing MES No. including cutting hole suitable for fixing exhaust fan complete all as specified and directed
Supply and fixing heavy duty exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 350 mm complete fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to exhaust fan and writing MES No. including cutting hole suitable for fixing exhaust fan complete all as specified and directed
Supply and fixing lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed.
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, SPN 8 way, 240 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, including dismantling of old UNSV one of any size/type from site and making good to disturbe surface wall complete all as directed NOTE: Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to included in the quoted rates.
Supply and fixing MCB of SP 5 to 32 Amps current carrying capacity, 240 V, 10KA 'C' curve fixed in the MCB DB complete with connection testing & commissioning complete all as directed
All as per ser item No. 18 above but for MCB SPN 40 to 63 Amps, 415 V grade
Supply and fixing in replacement, Sub main wiring with two single pole 6 sqmm (nominal area) stranded copper conductor FRLS PVC insulated and unsheathed cable drawn in and including non metalic PVC rigid conduit medium grade of suitable size with all standared fitting, on surface including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 6 sqmm (nominal area for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed Note:- 1 Two runs of 6 sqmm main cable one run of 6 sqmm for earth cable & conduit shall be measured as one unit one running meter.
Supply and fixing in replacement, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductor FRLS PVC insulated and unsheathed cable drawn in and including non metalic PVC rigid conduit medium grade of suitable size with all standared fitting, on surface including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cable & conduit shall be measured as one unit one running meter.
S&F ceiling fan 1200mm sweep complete with blades, down rod as per site requirement, electronic regulator & accessories (i.e. PVC canopy, rubber bush, split pin, hanging clamp, hold fasteners etc.) 230 Volts, white colour, with min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor (BLDC) technology and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to ceiling fan and complete all as specified and directed.
Material and Labour for distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way , 3 phase , 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, including dismantling of old UNSV one of any type/size from site and making good to disturbe surface wall complete all as directed (1.) MCCB 100 Amps , 25 KA, TP 415 Volts
Material & Labour in replacement Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 mr deep below normal ground level) with top edge of the plate not less than 1.5 mr below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and Gl washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.3 of SSR Part-l and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade Gl pipe, funnel, wire mesh. Concrete 1:3:6 type C-1 for pit and RCC pit cover. The extra cost of the water- ing pipe,bends, elbows shall be included in the unit rate. Note: RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm.
Supply and fixing Dusk & dawn roadway luminaries 45 Watt, 230 V AC, 5700K outdoor type with epoxy black powder coated sheet, high pressure die-cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics, PF>95%, THD<10%, Lumen>4500 lm with IP 65/66 protection complete incl connecting wire with flexible PVC insulated copper cables from ceiling rose to fitting including driver, lamp bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length not exceeding 1.5 mtr, through mild steel clamp of 25mm width and four Nos. nuts, bolts & washers of 12mm dia, 100mm long fixed to wall with all other fittings complete and testing all as specified and directed.
S&F 100W LED floodlight fitting typically features a rectangular or square shape, with a die-cast aluminum housing and a tempered glass or polycarbonate diffuser. It is designed for outdoor use, with an IP65 or higher rating for dust and water protection and an IK08 or higher rating for impact protection. The fitting includes a high-efficiency LED module, an integral complete all as specified
ESS KAY BUILDER (BID ID -3407533)
GEE EMM ASSOCIATES (BID ID -3407190)
m/s inder construction co (BID ID -3408999)
RAJ KAMAL BUILDERS (BID ID -3408697)
M/s. M Company (BID ID -3407523)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .