| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.0 L+₹4.0 L (21.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹23.0 L+₹4.0 L (21.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
COMPREHENSIVE MAINT TO SCC 7 GARHWAL RIF AND OTHER MINOR UNITS IN SI LINES UNDER GE BHOPAL
2024_MES_665906_1
8306/E8
Open Tender
Civil Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹60,000
Yes
19 Oct 2024
13 Jul 2024
14 Sept 2024
13 Jul 2024
12 Sept 2024
27 Jul 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/ blankets, any thickness including cover filles complete all as specified and directed.
S&F for 605mm x 605mm anodised aluminium snap grid frame work for false ceiling including providing and fixing 600mm x 600mm X 6mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre complete all as specified and directed.
S&F of GI frame work size of grid 605 mm x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylone sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
M&L for providing and fixing 12mm gypsum board ceiling fixed with screws and applying two coats of oil bound distemper complete all as specified and directed.
S&F in repair PVC wall lining consisting of 5mm thick wood grain printed PVC sheet colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets including ridges in roof covering complete all as specified and directed.
Dismantling timber in fillets rails, posts, rafters, purlins etc under 40 Sqcm in section framed work complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges and similar work fixed with self tapping screws complete all as specified and directed.
M&L for 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations sid lap fixed with L type or J type or cranked hook bolts complete all as specified and directed.
S&F of steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of concrete in ground floors and pavings (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in cills, ceismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in sub base for floors and paving complete all as specified and directed.
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc including brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed.
M&L for virified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick in cement mortar 1: 6 complete all as specified and directed
M&L for virified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick in cement mortar 1: 4 complete all as specified and directed
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick in cement mortar 1:6 complete all as specified and as directed
M&L for coloured glazed ceramic tiles in vertical surface of 300X200X7 to 8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in vertical surface skirting/dedos etc over and including 10mm thick in cement mortar back coat 1: 4 complete all as specified and directed
M & L for glazed ceramic tiles in vertical surface of 300X 600X 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in vertical surface skirting / dedos etc over and including 10mm thick in cement mortar back coat 1: 4 complete all as specified and directed
M&L for taking down and refixing in same opening size of shutter exc 1sqm and not exc 2 sqm complete all as specified and directed.
Demolition of stone slabs of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing to give high gloss finish over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing to give high gloss finish over and including 10mm thick backing coat in CM 1:4 complete all as specified and as directed
M&L for 600mmx600mm acid resistant tiles of 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors complete all as specified and directed.
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Disimantling and relaying of old servicable machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 30mm thick sand bed complete all as specified and directed.
M&L for mirror polishing on marble/ granite/ kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar complete all as specified and directed.
M&L for fly ash brick work, straight or curved on plan of any radius in half brick thick walls using modular bricks built in CM 1:4 complete all as specified and directed.
M&L for fly ash brick work, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in 1:6 cement mortar and finished even and smooth without using extra cement including preparing new plastered surface of wall and applying complete all as specified and as directed.
Material & labour for rendering 15mm thick in cement mortar 1:4 mixed with waterproofing compound @ 3% by weight of cement on fair faces of brick work or concrete surfaces of wall and finished even and smooth without using extra cement complete all as specified and directed.
Supply and fixing GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, stone wall etc. including all laps, cutting and waste complete all as specified and directed.
Supply only integral waterproofing compound complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar 1:3 in concrete surface of ceiling finished even and smooth without using extra cement including preparing to new plastered surface and applying three coat of white wash complete all as specified and directed
M&L for applying 1mm thick (average) putty for smooth finish on prepared surface complete all as specified and directed
S&F in repair 12mm thick and 7-ply(no of Ply), veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces fixed with screws to timber frame work complete all as specified and directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each and removing from site complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exc 1.5 Sqm and not exc. 4 sqm each and removing from site complete all as specified and directed.
Taking down shutter exc 1 sqm and not exc 2 sqm complete all as specified and directed.
Easing of door shutters any type wooden/PVC/aluminium type for easy closing / opening tightening of hinges or changing the position of hinges adjustment of tower bolts, sliding bolts with new screws etc complete all as specified and directed.
Easing of window shutters, kitchen cupboard shutters, show case shutter drawers including fixing of screws adjusting handles, knobs tightening piano hinges including misc small adjustments complete all as specified and directed.
Supply and fixing pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of priming complete all as specified and directed.
Material and labour for PCC 1:3:6, type C-0 (using 12.5 mm graded stone aggregate) as in filling of pressed steel frame complete all as specified and directed.
S&F for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall beacceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed.
Supply and fixing 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, covered with decorative face veneers with lipping/ frame to match on both sides complete all as specified and directed.
Supply and fixing 35 mm thick, 2nd class hard wood, glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sashbars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified and directed.
S&F for factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/Sqmm, modulus of elasticity 850 N/Sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and provision and fixing with and including stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.
S&F of factory made solid PVC moulded door shutter with particle board core 28mm to 30mm thick (style) with 2, 4 or 6 raised panel design with 2mm thick 3D plain colour PVC sheet on the front face and 2mm plain colour PC sheet on back face complete all as specified and directed.
S&F anodised aluminium door frame/shutter/partitian frame for doors, windows, ventilators with one or more rebates including joining cleat grill for fixing etc. complete all as specified and directed.
M&L for repairs existing aluminium door/window shutter including frame with completely/partially taking down door shutter and tightening of all screws, replacing including provision of unservicable hinge, handle, lock, aluminium plate & floor door stopper complete all as specified and directed.
Supply and fixing aluminium handles extruded type of size 125mm, complete all as specified and directed.
Supply and fixing 150 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed.
Supply and fixing 250 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cost or extruded sections or cast alumminium alloy complete all as specified and directed.
Supply and fixing 140mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wireand average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wireand average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F for 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S & F in repair 3mm thick plain sheet glass, ordinary quality in square n. exc. 0.5 sqm in each pane glazing with oil putty complete all as specified and directed.
Material and labour for painting to new wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, priming with pink primer (one coat) finished with two coats of synthetic enamel paint complete all as specified and directed.
S & F 10mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed.
Supply& fixing heavy duty hydraulic door spring door closer fixed to floor for heavy toughned glass door including top SS bracket with heavy duty pivot for for fixing of glass door with glass partition complete all as specified and directed. Make Godrej (Product code:- D-150 size 308mm x 108mm x 40mm) or equivalent
Supply & fix fancy type stainless steel body (St-304) lock for toughned glass door with two set of keys complete all as specified and directed. Make Godrej (Kurve) (Product Code 5752 size 179.5mm x 52mm ) or equivalent
S & F 300mm long fancy H-type stainless steel handle made out of 25mm dia stainless steel pipe fixed to toughned glass door complete all as specified and directed. Make Godrej (Product code 2807) or equivalent
S & F in repair aluminium die cast door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
Supply and fixing light coloured vitreous china wash hand basin, available shape as approved of 550mmx400mm (minimun) on new pre-painted brackets excluding taps but including 32 mm bore waste fittings, brass, chromium plated etc complete all as specified and directed.
Supply & fixing in repair vitreous china squatting pan “Orissa pattern” size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with CI ‘P’ trap of long arm of suitable size including connection to flush pipe, anti symphonic pipes and bed concrete etc complete all as specified and directed.
Supply & fixing in repair vitreous china wash down water closet pan (Pedestal Pattern) and trap (standard pattern) coloured as approved including connection to drain (or outgoing pipe) and to flushing pipe anti symphonize pipe etc. including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and jointing complete with fixing bolts complete all as specified and directed.
S&F in repair vitreous china premium /1st quality wash down water closet wall hung EWC white /ivory/off white closed pattern including all necessary accessories like rag bolts, gel galskets etc. (excluding flushing cistern and flush pipe but including provision of lastic water closet seat, white/black, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminium hinging device and jointingcomplete with fixing bolts complete in all respect complete all as specified and directed
Supply & fixing in repair vitreous china half stall, urinal flat back, with grating and union for discharge pipe fixed in repairs (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
Supply and fixing PVC valveless, syphonic action type, flushing cistern of 10 Ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
Supply only flush pipe of polyethylene of low or high density or PVC, 32 mm dia, for low level cistern complete all as specified and directed.
Supply & fixing in repair plastic water closet seat, any colour as available, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and jointing complete all as specified and as directed.
Supply & fixing in repair urinal spreader of chromium plated for fixing with 15mm dia pipe complete all as specified and as directed.
Supply and fixing in repair of fancy type, pillar taps, cast copper alloy with capstan heads, chromium plated screwed, down high pressure with or without lettered Hot or Cold with long screwed shank supply and fixing ly nuts for iron pipe of 15mm bore fancy type complete all as specified and directed.
Supply and fixing in repair of fancy type, chromium plated, bib tap, 15mm bore complete all as specified and directed.
Supply and fixing in repair of CP brass, fancy type, stop cock with long shank & as concealed type angular type complete all as specified and directed.
S & F in repair 15mm dia, brass CP for mixing hot & cold water, fancy type, screwed down for iron pipe and fixed with wash hand basin all sink complete all as specified and as directed.
S & F in repair 15mm bore, bib cock two way with flange cast copper alloy, fancy type, chromium plated screwed down for iron pipe and fixed complete all as specified and as directed.
Supply and fixing PVC connection 15 mm size, of length 450 mm, with PTMT nuts complete all as specified and directed.
Supply and fixing PVC connection 15 mm size, of length 600 mm, with brass nuts complete all as specified and directed.
Supply and fixing in repair toilet paper holder with flat recessed type stainless steel complete all as specified and directed.
Supply and fixing in repair soap dish, vitreous china white, approximate size 160x 160x90mm complete all as specified and directed.
Supply and fixing in repair sheet glass shelf assembly consisting of 5.5mm thick, sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repair 20mm dia tubular towel rail including a pair of bracket with matching specification and size complete all as specified and directed.
Supplying and laying in repair of 16mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down old pipes complete all as specified and directed.
Supplying and laying in repair of 20mm bore CPVC pipes SDR 11 & CPVC SDR 11 brass fittings on walls/ceiling or laying in floors including taking down old pipes complete all as specified and directed.
S & F in repair 15mm dia, GI water tubes, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F in repair 20mm dia, GI water tubes, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs stainless steel sink, 1.00mm thick for kitchen, with plug, washers, waste coupling, waste pipe including bedding in cement mortar to dwarf wall or fixing with cantilever brackets and connecting union to pipe, overall size 495mm x 420mm with bowl size 410mmx330mm x160mm complete all as specified and directed.
S&F in repairs CP health faucet suitable for 15mm bore with 1.2m flexible pipe and connecting pieces including all necessary accessories complete all as specified and directed.
Petty repairs to servicable sensor & fancy plumbing fittings by authorised agent including providing & replacing genuine company manufactured spare parts if required at site complete all as specified and as directed.
S&F in repairs, urinal sensor fitting accessories including removal of old unservicable sensor fitting from urinal of branded manufacturer's matching to existing urinal complete all as specified and as directed
S & F in repair 15mm ball valves, high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed.
S & F in repair 20mm ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed.
S & F for PP-R gate valve 20mm outer dia and brass insert as per requirement of the site fixed to CPVC pipe line complete all as specified and as directed
Supply and fix in repair vitreous china table top wash hand basin of size 550x400x160mm fixed to grenite counter complete all as specified and as directed. Make Cera (Campa) Cat. No. S2020102 or equivalent in Hindware/ parryware as approved by GE.
Supply and fix in repair snow white colour square shaped vitrious china one piece cascade type EWC with attached Flushing cistern and concealed S Trap of size 655 x 345 x 750mm & flushing cistern of size 325mm x 345mm x 150mm including soft closing PVC seat and cover complete all as specified and as directed. Make Cera (Captor) Cat. No. S1013205 or equivalent in Hindware/ parryware as approved by GE.
S & F in repair 15mm inlet dia prayag ABS body hand shower of size 75mm including PVC connection 1m long complete all as specified and as directed Make :- Prayag cat No BHS-85 equivalent in Jaquare/ plumber as approved by GE.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Refixing of GI tubing, medium grade, 15 mm dia after cleaning of pipe with all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and as directed.
Refixing of GI tubing, medium grade, 20 mm dia after cleaning of pipe with all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and as directed.
Refixing of GI tubing, medium grade, 25 mm dia after cleaning of pipe with all fittings and fixed complete to walls and ceiling or laid on floors complete all as specified and as directed.
S&F 15 mm bore GI tubing, medium grade, galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls and ceilings or laid in floors complete all as specified and directed.
S&F 20 mm bore GI tubing, medium grade, galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 25 mm bore GI tubing, medium grade, galvanised with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Dismantling water tanks of capacity exc 250 litres but nexc 500 litres and removing to store complete all as specied and directed.
Dismantling water tanks of capacity exc 500 litres but nexc 1000 litres and removing to store complete all as specied and directed.
S&F for 500 ltrs capacity, rotational moulded 3 layer HDPE water storage tanks (Cylindrical vertical with closed top) Dimen hoisted and fixed in position all as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed.
S&F 1000 ltrs capacity, rotational moulded 3 layer HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed.
S&F of 20 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) complete all as specified and directed.
S&F of gunmental, globe or gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair to 25 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F in repair to 20 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F in repair to 15 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F in repair to gunmental, globe or gate valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair to gunmental, globe or gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair to gunmental, globe or gate valves 15 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair to PVC tank lid (Cover) for tank of 500 Ltr capacity including locking arrangement with pad lock if required of Godrej size 50 mm (steel) comlete all as specified and directed.
S&F in repair to PVC tank lid (Cover) for tank of 1000 Ltr capacity including locking arrangement with pad lock of Godrej size 50 mm (steel) if required comlete all as specified and directed.
M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity not exceeding 500 Ltr of any description and in any position comprising following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using Trebac G5/Inchlor-5/NB-10, Terbac G65/Inoxi-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) First stage is to drain out the water by using exit valve or our own high capacity dewareing systems or any other suitable method approved by Engr-in-Charge. (b) Second stage is cleaning all the algae formation inside the tank by using Terbac G 10/ Inchlor-5/NB-10, a laboratory tested barnded chemical of the company and scrubbing the walls of the tanks. (c) Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSL. (d) Fourth stage first bacteria screening and Sterilization by using Terbac G5/Inchor-5/ NB-10, a Laboratory certified branded halogen compound, test certificate of Terbac G5/Inchor-5/ NB-10, from government laboratory mentioning suitability for sterilization. (e) Fifth stage is cleaning the floors of the water tank by heavy duty industrial vaccum cleaner. (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria. g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TerbacG65/Inoxi-60/NB-69. Note:- (i) Test certificate of Terbac G65/Inoxi-60/NB-69 from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (iii) Contractor will be responsible for rectification of complaints occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/blockage of Outlet lines due to silt and rectification cost will be deemed to be included in quoted rate.
M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity exceeding 500 Ltr but not exceeding 1000 ltrs of any description and in any position comprising following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using Trebac G5/Inchlor-5/NB-10, Terbac G65/Inoxi-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) First stage is to drain out the water by using exit valve or our own high capacity dewareing systems or any other suitable method approved by Engr-in-Charge. (b) Second stage is cleaning all the algae formation inside the tank by using Terbac G 10/ Inchlor-5/NB-10, a laboratory tested barnded chemical of the company and scrubbing the walls of the tanks. (c) Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSL. (d) Fourth stage first bacteria screening and Sterilization by using Terbac G5/Inchor-5/ NB-10, a Laboratory certified branded halogen compound, test certificate of TerbacG5/Inchor-5/ NB-10, from government laboratory mentioning suitability for sterilization. (e) Fifth stage is cleaning the floors of the water tank by heavy duty industrial vaccum cleaner. (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria. g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TerbacG65/Inoxi-60/NB-69. Note:- (i) Test certificate of Terbac G65/Inoxi-60/NB-69 from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (iii) Contractor will be responsible for rectification of complaints occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/blockage of Outlet lines due to silt and rectification cost will be deemed to be included in quoted rate.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconneting and refixing in position capacity exc 250 and n exc 500 ltr. including cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipes etc complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconneting and refixing in position capacity exc 500 and n exc 1000 ltr. including cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipes etc complete all as specified and directed.
Taking down carefully existing point wiring (any type, aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
M&L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FRLS cables 1.5 sqmm as per IS 694:2010, ISI marked, annealed multistranded copper conductor drawn through and including, medium grade, machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting/metal flush box/ cover plate/junctiion boxes/inspection cover etc, ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FRLS cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1:3 including necessary plaster and pointing in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed (Note cost of cutting chase and making good shall be included in the quated rates & wiring to be done as per approved colour code in IE rule complete all as specified and directed.
All as per ser item No 138.00 here-in-before but for one switch socket combination 5/6 amp on independent board
All as per Srl item No 138.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches
All as per Srl item No 138.00 here-in-before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.
All as per Srl item No. 138.00 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire
M&L for casing caping/conduit point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FRLS cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LS cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed (Note cost of cutting chase and making good shall be included in the quated rates & Wiring to be done as per approved colour code in IE rule complete all as specified and directed.
All as per Srl item No 143.00 here in before but for one light point controlled by 5/6 A two 2-way switches
All as per Srl item No 143.00 here in before but for one switch socket combination 5/6 amp on independent board
All as per Srl item No 143.00 here in before but for one three pin socket outlet 5 Amp on same board with other switches
All as per Srl item No. 143.00 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.
All as per Srl item No. 143.00 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire.
S&F in repairs switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F in repairs switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F in repairs Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F in repair switch piano, one way, single pole, 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 3 pin 5 and 15 Amp, flush type, 240 volt AC complete all as specified and as directed.
S&F in repairs socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed.
S&F in repairs switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC with PVC Back Cover ISI marked complete all as specified and as directed.
S&F in repairs ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed.
S&F in repairs Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed.
Supply and fixing angle holder, PVC/Poly carbonate type with back plate suitable for batten fittings complete all as spcified and directed.
Supply and fixing in replacement of dismantling and removing of 36/40W tube light fitting patty/box/decorative/any type and replacement with LED type tube light fitting, surface mounted lumanaires, decorative ultra slim round /square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps,connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible 3 core copper conductor cable of suitable size complete all as specified and directed. Note :- Contractor will produce manufacturer test certificate & min 2 year warrenty from date of fixing.
S&F in replacement warm white in colour LED tube light complete fitting, surface mounted luminanaires, 18 watt, 240V, decorative ultra slim round/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with bipin holders, LED Lamps, connector block, etc complete with all accessories internally prewired and including connecting up with flexible 3 core copper conductor cable with suitable size complete all as specified and directed. Note :- Contractor will produce manufacturer test certificate & min two year warrenty from date of fixing.
S&F in replacement of white LED tube light fitting two feet 10 watt, slim design, 230 volts, including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed. Note :- Contractor will produce manufacturer test certificate & min two year warrenty from date of fixing.
S&F in replacement of warm white LED tube light fitting two feet 10 watt, slim design, 230 volts, including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Note :- Contractor will produce manufacturer test certificate & min two year warrenty from date of fixing.
S&F in repairs ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush/socket type complete all as specified and as directed.
S&F PVC insulated unsheathed, ISI marked FRLS copper cable, 1.5 Sqmm AC 230 V complete all as specified and directed.
S&F PVC insulated unsheathed, ISI marked FRLS copper cable, 2.5 Sqmm AC 230 V complete all as specified and directed.
S & F modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S & F modular switch, one way, 16 Amp, one module, 240 volts complete all as specified and directed.
S & F modular Bell Push switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F modular socket outlet 2-in-1, 5pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed.
Supply and fixing modular switch socket combination, multipurpose 6 pin, 16 amp, 3 module complete all as specified and directed.
Supply and fixing modular fan regulator, 5 stepped, high speed complete all as specified and directed.
S & F modular metal flush box of 6 module complete all as specified and directed.
S & F modular metal flush box of 4 module complete all as specified and directed.
S & F modular metal flush box of 3 module complete all as specified and directed.
S & F modular white cover plate with frame of 6 module complete all as specified and directed.
S & F modular white cover plate with frame of 4 module complete all as specified and directed.
S & F modular white cover plate with frame of 3 module complete all as specified and directed.
Taking down unserviceable sub main wiring including service connections, of any size and any description including conduit pipe and making good disturbed surface of walls/ ceiling to match with existing surface after necessary rewiring complete all as specified and directed .
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including MCCB/MCB and wooden boards complete all as specified and directed.
S&F sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 amps rated busbar, 4 way, double door, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP-43 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. NOTE:- MCB shall be measured and paid seperatly.
Supply and fixing factory made epoxy powder coated distribution board TPN, 4 ways (VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated neutral bar, insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed. NOTE:- MCCB shall be measured and paid seperatly.
S&F sheet metal enclosure double door type surface mounted concealed in wall 8 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. NOTE:- MCB shall be measured and paid separately.
S&F sheet metal enclosure double door type, surface mounted concealed in wall 12 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. NOTE:- MCB shall be measured and paid separately.
S&F MCCB 160 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed.
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 6 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 40 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCB SPN suitable for 240 volts, 'B' curve, AC supply 6 to 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed.
S & F in repairs MCB SPN suitable for 240 volts, 'B' curve, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F in repairs MCB TPN suitable for 240 volts, 'B' curve, AC supply 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F in repairs MCB TPN suitable for 240 volts, 'B' curve, AC supply 100 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F in replacement 3 pin plug, AC-230 V, 5 Amp, complete all as specified and directed.
S&F in replacement 3 pin plug top, AC-230 V, 15 Amp complete all as specified and directed.
S&F in replacement sheet metal earth plug & socket, single pole and neutral with and including 1no. single pole MCB 20 Amps 240 volts complete all as specified and directed.
S&F in replacement PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC,
S&F non metallic rigid PVC casing and caping ISI marked of 20mm size complete all as specified and directed.
S&F non metalic PVC conduit ISI marked of size 20mm dia complete all as specified and directed.
S&F in replacement LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt white in colour with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core complete all as specified & directed.
S&F in replacement LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt Warm white in colour with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core complete all as specified & directed.
Supply and fix in repairs coral post top lantern fitting 25 Watt ( for Gate light), energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories and with PVC insulated multistranded copper flexible cable 0.5 sqmm three core all as specified and directed by Engineer in charge.
S&F in replacement building security light fitting made up of pressure die cast alluminium housing with high efficient 30 Watt LED as lighting source and pc over having top opening separate driver compartment with IP-66 Protection and including IK-07 protection suitable galvanized iron pipe ,light grade, brackets 1 mtr length bent to shape to obtain required shape including clamps, nuts/bolts/washers etc connecting with with PVC insulated multistranded copper flexible cable 0.5 sqmm three core copper wire complete all as specified and directed.
S&F in replacement flexible wire three core copper conductor of size 23/0.0076 for ceiling fans ,light fittings etc complete all as specified and directed.
Supply and fix in replacement of LED slim square/circular panel light fitting for surface ceiling light 12 watt, colour warm white including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
Supply & fixing in replacement recess mounting spot LED light round downlighter designed with excellent thermally managed luminaire 12 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible coppder conductor cases of suitable size complete all as specified and directed by Engineer in charge
Supply & fixing flexible LED strip uses high brightness SMD LED as the light source for indoor application only, luminaire 24 watt, 220V AC with high efficiency light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with three core flexible coppder conductor cases of suitable size (Flexion Neo Led Strip 24 W of any colour) complete all as specified and directed by Engineer in charge
M&L in replacement for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe, medium grade, for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S&F in repairs 11 x 13 inches laminated hylem sheet cover, ISI marked of Make" Hylem" including cutting grooves for mounting of fittings like switches, sockets, fan regulators etc; including fixing in location with new galvanised screws and cup washer complete all as specified and directed
All as per item No. 209.00 here-in-before but of size 9 x 11 inches
All as per item No. 209.00 here-in-before but of size 5 x 8 inches
All as per item No. 209.00 here-in-before but of size 5 x 5 inches
Dismantling of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm (collected from MES fan store ) any make / model except old vintage, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES fan store after testing complete all as specified and directed.
All as per item No. 213.00 here-in-before but exhaust fan, 400/450 mm sweep, AC single phase, 230/240 volts complete all as specified and directed.
All as per item No. 213.00 here-in-before but exhaust fan, 300/380 mm sweep, AC single phase, 230/240 volts complete all as specified and directed.
All as per item No. 213.00 here-in-before but exhaust fan, 230/250 mm sweep, AC single phase, 230/240 volts complete all as specified and directed.
All as per item No. 213.00 here-in-before but wall / pedestal fan, of any sweep and capacity complete all as specified and directed.
S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of clips for down rod with rubber bush (Garari) including set of nut bolts and washer, pin complete all as specified and directed.
S&F in replacement rubber bush (Garari) for mounting at upper side of down rod clip complete all as specified and directed
S&F in replacement gun metal bush self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed
S&F in replacement Fan condenser 2.5 mfd, 230 volts complete all as specified and directed.
S&F in replacement Fan condenser 3.15 mfd, 230 volts complete all as specified and directed.
S&F in replacement Fan condenser 4.0 mfd, 230 volts complete all as specified and directed.
Supply only bearing No 6201'ZZ' for fixing against defective bearing of fan taking down complete all as specified and directed.
All as per item No. 225.00 here-in-before but bearing No 6202'ZZ'
All as per item No. 225.00 here-in-before but bearing No 6203'ZZ'
All as per item No. 225.00 here-in-before but bearing No 6204'ZZ'
Taking down ceiling/wall fan from fan hook and disconnection from ceiling rose, dismantling of fan parts i e. down rod and connector/condenser, nut bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting/reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
Taking down exhaust fan and disconnection from ceiling rose, dismantling of fan parts i e. connector/ condenser, nut bolts, condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting/reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 450 mm /380 mm sweep exhaust fans complete all as specified and directed.
S&F in repairs top and bottom canopy of ceiling fan (any sweep) of make , colour and pattern as per existing model all as specified and directed
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 230 mm /300 mm sweep exhaust fans complete all as specified and directed.
M&L for painting of ceiling fan upto 1200/1400mm sweep with two coats of DUCO paint (ISI grade) white using spray machine. Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES No in all ceiling and Exhaust fan complete all as specified and directed. Note:- Taking down and fixing of fan will be measured under relevent item.
All as per item No. 234.00 here-in-before but for exhaust fan upto 280/300/380/450 mm sweep with smoke grey paint
Dismantling geyser of 25 ltrs capacity and of any description and M&L for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/scale is removed and approved by the Engineer-in-Charge, brazing for stopping the leakage of copper inner tank/ gas welding for stopping the leakage of inner steel tanks, fixing the serviceable parts in position, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing and painting, fixing & installation of the geyser in position and its testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. NOTE:- (i) De-scaling chemical shall be concentrated HCL of make as approved by GE. (ii) Painting of Geysers shall be on requirement basis and shall be measured and paid for separately under appropriate item of schedule. (iv) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool and additional quantity of glass wool for insulation, if any required, is deemed to be included in the quoted unit rate. (v) Spares parts as required shall be measured and paid seperately.
All as per Item Sl No. 236.00 here-in-before but geyser of capacity 50 Ltrs complete all as specified and directed.
S&F 1.5 KW capacity Heating Element (ISI marked) round type/thread/triangle / Push/ Screw base type with ‘O’ ring including making electrical connection complete all as specified and directed.
S&F 2.0 KW capacity Heating Element (ISI marked) round type/thread/triangle/ Push/ Screw base type with ‘O’ ring including making electrical connection complete all as specified and directed.
S&F electronic Heating Element (ISI marked) fitted with auto cut thermostat 1.5/2.0 KW suitable for 25/50 ltr geyser including making electrical connection complete all as specified and directed.
S&F in replacement Geyser assembly suitable for 25 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement Geyser assembly suitable for 50 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement thermostat suitable for 25/50 Ltr Geyser ISI marked with setting range 30 C to 80 C suitable for 230 volts AC electric supply complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geyser complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement indicating lamp (set of two) 230 volts 50 HZ AC suitable for geyser any type (round, square or rectangular type) any capacity complete all as specified and as directed.
M&L for painting of geyser, 25 ltr capacity with two coats of DUCO paint (ISI grade) white using spray machine, spray painting including cleaning, washing and preparation of old painted surfaces including writing MES No. complete all as specified and directed.
All as per item No. 251.00 here-in-before but of 50 ltr capacity.
S&F in replacement PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in replacemnt PVC connections 15 mm size nylon braided, heavy duty, 450mm long including rubber washers (suitable for hot water) complete all as specified and directed.
S&F in replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 47198.00
M/s H V Infra Projects (BID ID -3086511)
MS MOHD RIZWAN KHAN (BID ID -3094217)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .