| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 CrAdmitted-Finance | ₹10.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹11.8 CrAdmitted-Finance GUWAHATI | KAMRUP | ASSAM | 781030 | ₹11.8 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| 4 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| Sl No | Description | Qty | Unit | Meetei Construction Private Limited L2 | K. Santabiren Singh L1 |
|---|---|---|---|---|---|
| 1.00SH: (1) Administrative Building | |||||
| 2.00 | Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. | 164.67 | cum. | 352 ₹57,963.84 | 411.74 ₹67,801.23 |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. | 109.78 | cum. | 183 ₹20,089.74 | 173.05 ₹18,997.43 |
| 4.00 | Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete. | 99.15 | cum. | 995 ₹98,654.25 | 794.51 ₹78,775.67 |
| 5.00 | Boulder with minimum size of 300mm for pitching at Site | 28.51 | cum. | 1,239 ₹35,323.89 | 1,313.68 ₹37,453.02 |
| 6.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size. | 25.37 | cum. | 8,176 ₹2.1 L | 7,869.04 ₹2.0 L |
| 7.00 | Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering (a) 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size) | 20.51 | cum. | 10,301 ₹2.1 L | 9,511.93 ₹2.0 L |
| 8.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) RCC Grade M25 | 43 | cum. | 13,047 ₹5.6 L | 10,979.13 ₹4.7 L |
| 9.00 | Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) RCC Grade M25. | 93.89 | cum. | 14,207 ₹13.3 L | 12,663.05 ₹11.9 L |
| 10.00 | Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) RCC Grade M25 | 14.42 | cum. | 14,207 ₹2.0 L | 12,196.22 ₹1.8 L |
Tender Value
₹13.1 Cr
EMD Value
₹26.1 L
Closing Date
22 Dec 2025, 5:00 pmClosed
Executive Engineer Div I
Education Engineering Wing, Education(S), Babupara, Near D.C. Office (Old), Imphal West
Construction of New Model Degree College at Kamjong District Head Quarters under PM-USHA 2025-26
2025_DoEs_3082_1
EEW/T-14/E-TENDER/2025-26/20 (2nd Call)
Open Tender
Civil Works - Buildings
Kamjong
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Chief Finance Officer
₹26.1 L
Office of Chief Engineer EEW
2 Jan 2026
1 Dec 2025
23 Dec 2025
2 Dec 2025
22 Dec 2025
2 Dec 2025
8 Dec 2025
Amount
SH: (1) Administrative Building
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering (a) 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) RCC Grade M25
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) RCC Grade M25.
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) RCC Grade M25
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Column, Pillars, Piers, Abutments, Post and Struts.
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
d) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness.
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : Local best quality Teak wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Teak wood: 35 mm thick shutters
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing ISI marked oxidised M.S.sliding door bolts with screws etc. complete 250x16 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade using 50% white cement 50% Grey cement.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. (i) Electric resistance or induction butt welded tubes.
Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00mm thick with zinc coating not less than 275gm/m2
Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 0.80mm thick with zinc coating not less than 275gm/m2.
P/F at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm
at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I,
12 mm cement plaster of mix 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
SH: IEI for Administrative Building
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
c) Group C
Suitable size GI box with modular plate and in front on surface or in recess i/c p/f 6 pin 16/15 amp modular socket outlet 15/16 amp modular switch, connection painting etc as required
S/F suitable size G.l box with modular plate and cover infront on surface or recess i/c p/f 3pin 5/6 amp modular socket outlet 5/6 amp modular switch connection painting etc as reqd.
(1.7) Wiring for circuit/sub-main wiring along with earth wire with the (following size of ) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc. as reqd.
1)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
2)2 x 2.5mm2 + 1 x 2.5mm2 Earthwire
3)2 x 4mm2 + 1 x 4mm2 Earthwire
4)2 x 6mm2 + 1 x 6mm2 Earthwire
5)2 x 10mm2 + 1 x 10mm2 Earthwire
(1.87) S/F (following way) single pole and neutral, sheet steel MCCB DB 240v on surface/recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connection, pho phatised and power painted including earthing etc. as required (but without MCB/ RCCB/ isolator)
(1.107) S/F 5amp t.o32 amp rating 230V "B" series for lighting and other purposes, load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as required.
(2) Single pole and neutral
(1.109) S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required.
(1.84) P/f (following capacity TP&N) disconnector fuse switch unit inside the exiting cubicle panel board with I.S.l mark HRC fuses i/c drilling holes in the cubicle panel board making connection as reqd.
(2) 400 Amp TP&N
(2) 200 Amp TP&N
P/F 400Amp TPN stand ground on load on load change own switch (compact design) 415/500v including connection to as required.
S/F Busbar chamber with 4 strips copper busbar of length 600mm sujtable for 200 amps capacity complete with all accessories i/c connection earthing the body as required.
(8.01) S/F 48" sweep (1200mm)a.c ceiling fan complete with down rod canopy, 3 Blades but without regulator etc. as reqd. (Havells or similar 5 star)
305mm sweep exhaust fan complete with all accessories connection etc as required
l.62) S/F stepped type electronic fan regulator on the modular plate witch box i/c connection but excluding modular plate as reqd.
P/F swing wall fan
(1.7 I) S/F brass batten holder i/c connection etc. as reqd.
LED white lamp l 8w
S/F rece s mounting LED down lighter BGSL 0301WH 220225 Cast allumfoiu.m housing fixed with collinated lens 3x I W white lens mounted on MCPCB extruded alluminium heat sink spring loaded mounting clip ,complete with connection etc as reqd.
P/F lighting conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc. Complete as reqd
P/F copper tape in horizontal nm p copper tape 2ommxJmm thick on parapet or surface of wall for lightning conductor as reqd(for horizontal run)
P/F copper tape 20mmx3mm thick on parapet or surface of waU for lightning conductor as reqd(for vertical run)
(3.05) Earthing with copper earth plate 600 mmx 600mmx6mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) as reqd.
(3.06) Extra for using Salt & Charcoal for copper plate with electrode as reqd.
Earth connection from earth electrod with 4mm dia in 15mm GI pipe as required
Fabrication of controlled panel board by 16 guage steels sheet along with componets mounting making strip wiring auxiliary components wiring all over the panel i/c fixing charge painting etc as reqd.
SH: WS & SI for Administrative Building
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 50 mm nominal outer dia Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall: 32 mm nominal outer dia Pipes.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass
Providing and fixing wh.ite vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm dia
Providing and fixing 8 mm dia C.P/S.S. Jet with flexible tube upto I metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. Pan
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge
Providing and fixing CP Brass ingle lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia
Providing and fixing C.P. Brass extension nipple (size l5mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing toilet paper holder: C.P. brass
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm. 78 mm wide and elfeclive height of88 mm, weighing not less than I 70 gms.
Providing and fixing PTMT liquid soap container I09 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing and fixing mirror of superior glass (of approved quality) and of requiied shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing ; Rectangular shape 1500x450 mm
Providing and fixing P.V.C. waste pipe for sink or wash. basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing UPVC soil waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cernenl, trenching, refilling & testing of joints complete as per direction of Engineer in charge.
a) 110mm dia
b) 75mm dia
19 Providing and fixing G.L. pipes complete with G.I. fittings and clamps. i/c cutting and making good the walls elc.lntemal work - Exposed on wall
a) 25mm dia
b) 32mm dia
Providing and fixing (G.I Pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc.external work - Exposed on wall
Making connection of G.I. Distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc.complete ; 50 to 80 mm nominal bore
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
Providing and fixing C.P. brass slop cock (concealed) of standard design and of approved make conforming to IS:893 I. : 15 mm Nominal bore
Providing and fixing ball valve (brass) of approved quality High or low pressure with plastic floats complete :
a) 15 mm nominal bore
a) 20 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Supply and fixing self priming single phase (TEXMO or similar brand) of 1HP water pump of approved qualilty.
WATER RESERVOIR
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) RCC Grade M25
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) RCC Grade M25
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) RCC Grade M25.
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm thick.
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
SEPTIC TANK
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm thick.
c) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Providing and fixing C.I Cover frame (for manhole and chambers). (a) 600 mm x 450 mm (heavy duty).
SH: Fire Fighting for Administrative Building
FIRE ALARM SYSTEM
Supply,installation, testing and commissioning of intelligent Addressable ionisation type photoelectric & Smoke Detectors with dual chamber solid state design, indicating lamp, mounting base etc. as per detailed specification.
Suppling, installing, testing and commissioning of intelligent Addressible manual pull station with necessary accessories, etc.
Supplying, installing, testing and commissioning of intelligent Addressible Hooter with necessary accessories etc.
Supplying, installing, testing and commissioning of 2 core x 1.5 sq. mm, Armoured cables FRLS type confirming to IS standards and specifications.
HAND APPLIANCES
Supply of 4.5 KG. Capacity C02 Type Fire Extinguishers.
Supply of 6 KG Capacity ABC Type Fire Extinguishers.
Supply of 09 Ltr. Capacity AFFF Type Fire Extinguishers.
SH: Land Development for Administrative Building
Construction of embankment with material obtained from borrow pits (Construction of embankment with approved materials obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
SH: (2) Staff Quarter
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:3:6 ( 1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size).
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering (a) 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Column, Pillars, Piers, Abutments, Post and Struts.
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
d) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : Local best quality Teak wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Teak wood: 35 mm thick shutters
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing ISI marked oxidised M.S.sliding door bolts with screws etc. complete 250x16 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1 : 4 ( 1 cement: 4 coarse sand ) laid and pointing with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer -in - Charge. Polished Granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
12 mm cement plaster of mix 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats
Finishing walls with Acrylic Smooth exterior paint of required shade : — New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
SH: IEI for Staff Quarter
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
Suitable size GI box with modular plate and in front on surface or in recess i/c p/f 6 pin 16/15 amp modular socket outlet 15/16 amp modular switch, connection painting etc as required
S/F suitable size G.l box with modular plate and cover infront on surface or recess i/c p/f 3pin 5/6 amp modular socket outlet 5/6 amp modular switch connection painting etc as required.
(1.7) Wiring for circuit/sub-main wiring along with earth wire with the (following size of ) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc. as required.
1)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
3)2 x 4mm2 + 1 x 4mm2 Earthwire
4)2 x 6mm2 + 1 x 6mm2 Earthwire
(1.87) S/F (following way) single pole and neutral, sheet steel MCCB DB 240v on surface/recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connection, pho phatised and power painted including earthing etc. as required (but without MCB/ RCCB/ isolator)
(1.107) S/F 5amp t.o32 amp rating 230V "B" series for lighting and other purposes, load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as required.
(2) Single pole and neutral
(1.109) S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required.
(1.84) P/f (following capacity TP&N) disconnector fuse switch unit inside the exiting cubicle panel board with I.S.l mark HRC fuses i/c drilling holes in the cubicle panel board making connection as reqd.
(3) 100 Amp TP&N
(2.02) P/F 125Amp TPN stand ground on load change own switch (compact design) 415/500v including connection to as required
(8.01) S/F 48" sweep (1200mm)a.c ceiling fan complete with down rod canopy, 3 Blades but without regulator etc. as reqd. (Havells or similar 5 star)
l.62) S/F stepped type electronic fan regulator on the modular plate witch box i/c connection but excluding modular plate as required.
Lighter BGSL 0301WH 220225 Cast alluminium housing, fixed with collinated lens 3XIW white Led mounted on MCPCB, extruded alluminium heat sink, spring loaded mounting clips, complete with connection etc. as required.
SH: WS & SI for Staff Quarter
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof 12mm thick.
c) Edges of slabs and breaks in floors and walls: Under 20 cm wide.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. 8 mm thick.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (a) Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with utomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board: 510x1040 mm bowl depth 225 mm.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour: 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (a) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: 15 mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet : 250x130x30 mm
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe- 40 mm dia
White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap
Providing and fixing lead caulked joints to 100 mm HCI pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work:
a) 100mm nominal outer dia Pipes
b) 50 mm nominal outer dia Pipes
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15 mm nominal bore.
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. Concealed work, including cutting chases and making good the wall etc.
a) 1216 (16 mm OD) pipe
b) 1620 (20 mm OD) pipe
c) 2025 (25 mm OD) pipe
d) 2532 (32 mm OD) pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work: 50 mm nominal outer dia Pipes
Making connection of G.I. Distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc.complete ; 25 to 40 mm nominal bore
Providing and fixing brass bib cock of approved quality : 20 mm nominal bore code
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 32 mm nominal bore: Horizontal
SH: Land Development for Staff Quarter
Construction of embankment with material obtained from borrow pits (Construction of embankment with approved materials obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
SH: Fire Fighting for Staff Quarter
FIRE ALARM SYSTEM
Supply,installation, testing and commissioning of intelligent Addressable ionisation type photoelectric & Smoke Detectors with dual chamber solid state design, indicating lamp, mounting base etc. as per detailed specification.
Suppling, installing, testing and commissioning of intelligent Addressible manual pull station with necessary accessories, etc.
Supplying, installing, testing and commissioning of intelligent Addressible Hooter with necessary accessories etc.
Supplying, installing, testing and commissioning of 2 core x 1.5 sq. mm, Armoured cables FRLS type confirming to IS standards and specifications.
HAND APPLIANCES
Supply of 4.5 KG. Capacity C02 Type Fire Extinguishers.
Supply of 6 KG Capacity ABC Type Fire Extinguishers.
Supply of 09 Ltr. Capacity AFFF Type Fire Extinguishers.
SH: (3) Hostel Building
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering (a) 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Column, Pillars, Piers, Abutments, Post and Struts.
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
d) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : Local best quality Teak wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Teak wood: 35 mm thick shutters
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing ISI marked oxidised M.S.sliding door bolts with screws etc. complete 250x16 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1 : 4 ( 1 cement: 4 coarse sand ) laid and pointing with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer -in - Charge. Polished Granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. (i) Electric resistance or induction butt welded tubes.
Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275gm/m2
Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete.: 0.80mm thick with zinc coating not less than 275gm/m2
P/F at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to
a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I,
12 mm cement plaster of mix 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
SH: IEI for Hostel Building
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
c) Group C
Suitable size GI box with modular plate and in front on surface or in recess i/c p/f 6 pin 16/15 amp modular socket outlet 15/16 amp modular switch, connection painting etc as required
S/F suitable size G.l box with modular plate and cover infront on surface or recess i/c p/f 3pin 5/6 amp modular socket outlet 5/6 amp modular switch connection painting etc as reqd.
(1.7) Wiring for circuit/sub-main wiring along with earth wire with the (following size of ) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc. as reqd.
1)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
2)2 x 2.5mm2 + 1 x 2.5mm2 Earthwire
3)2 x 4mm2 + 1 x 4mm2 Earthwire
4)2 x 6mm2 + 1 x 6mm2 Earthwire
(1.87) S/F (following way) single pole and neutral, sheet steel MCCB DB 240v on surface/recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connection, pho phatised and power painted including earthing etc. as required (but without MCB/ RCCB/ isolator)
(1.107) S/F 5amp t.o32 amp rating 230V "B" series for lighting and other purposes, load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as required.
(2) Single pole and neutral
(1.109) S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required.
(1.84) P/f (following capacity TP&N) disconnector fuse switch unit inside the exiting cubicle panel board with I.S.l mark HRC fuses i/c drilling holes in the cubicle panel board making connection as reqd.
(2) 400 Amp TP&N
(2) 200 Amp TP&N
P/F 400Amp TPN stand ground on load on load change own switch (compact design) 415/500v including connection to as required.
S/F Busbar chamber with 4 strips copper busbar of length 600mm sujtable for 200 amps capacity complete with all accessories i/c connection earthing the body as required.
(8.01) S/F 48" sweep (1200mm)a.c ceiling fan complete with down rod canopy, 3 Blades but without regulator etc. as reqd. (Havells or similar 5 star)
305mm sweep exhaust fan complete with all accessories connection etc as required
l.62) S/F stepped type electronic fan regulator on the modular plate witch box i/c connection but excluding modular plate as reqd.
P/F swing wall fan
(1.7 I) S/F brass batten holder i/c connection etc. as reqd.
LED white lamp l 8w
S/F rece s mounting LED down lighter BGSL 0301WH 220225 Cast allumfoiu.m housing fixed with collinated lens 3x I W white lens mounted on MCPCB extruded alluminium heat sink spring loaded mounting clip ,complete with connection etc as reqd.
P/F lighting conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc. Complete as reqd
P/F copper tape in horizontal nm p copper tape 2ommxJmm thick on parapet or surface of wall for lightning conductor as reqd(for horizontal run)
P/F copper tape 20mmx3mm thick on parapet or surface of waU for lightning conductor as reqd(for vertical run)
(3.05) Earthing with copper earth plate 600 mmx 600mmx6mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) as reqd.
(3.06) Extra for using Salt & Charcoal for copper plate with electrode as reqd.
Earth connection from earth electrod with 4mm dia in 15mm GI pipe as required
SH: WS & SI for Hostel Building
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 50 mm nominal outer dia Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32mm nominal outer dia Pipes
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass
Providing and fixing wh.ite vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm dia
Providing and fixing 8 mm dia C.P. I S.S. Jet with flexible tube upto I metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. Pan
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge
Providing and fixing CP Brass angle lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia
Providing and fixing C.P. Brass extension nipple (size l 5mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing toilet paper holder: C.P. brass
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm. 78 mm wide and elfeclive height of88 mm, weighing not less than I 70 gms.
Providing and fixing PTMT liquid soap container I09 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing and fixing mirror of superior glass (of approved quality) and of requiied shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing ; Rectangular shape I 500x450 mm
Providing and fixing P.V.C. waste pipe for sink or wash. basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
18 Providing and fixing UPVC soil waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cernenl, trenching, refilling & testing of joints complete as per direction of Engineer in charge.
a) 110mm dia
b) 75mm dia
Providing and fixing G.L. pipes complete with G.I. fittings and clamps. i/c cutting and making good the walls elc.lntemal work - Exposed on wall
a) 25mm dia
b) 32mm dia
Providing and fixing (G.I Pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc.external work - Exposed on wall
Making connection of G.I. Distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc.complete ; 50 to 80 mm nominal bore
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
Providing and fixing C.P. brass slop cock (concealed) of standard design and of approved make conforming to IS:893 I. : 15 mm Nominal bore
Providing and fixing ball valve (brass) of approved quality High or low pressure with plastic floats complete :
a) 15 mm nominal bore
a) 20 mm nominal bore
Providing and fixing Waler Storage Tanks with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlel and 15 mm nominal G.I. outlet tube i/c hoisting a height of IO m above ground level. a) 2000 litres net capacity storage tanks
Supply and fixing self priming single phase (TEXMO or similar brand) of 1HP water pump of approved qualilty.
WATER RESERVOIR
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) RCC Grade M25
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) RCC Grade M25
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) RCC Grade M25.
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof 12mm thick
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof 12mm thick
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
SEPTIC TANK
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof 12mm thick.
c) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Providing and fixing C.I Cover frame (for manhole and chambers). (a) 600 mm x 450 mm (heavy duty).
SH: Land Development for Hostel Building
Construction of embankment with material obtained from borrow pits (Construction of embankment with approved materials obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
SH: Fire Fighting for Hostel Building
FIRE ALARM SYSTEM
Supply,installation, testing and commissioning of intelligent Addressable ionisation type photoelectric & Smoke Detectors with dual chamber solid state design, indicating lamp, mounting base etc. as per detailed specification.
Suppling, installing, testing and commissioning of intelligent Addressible manual pull station with necessary accessories, etc.
Supplying, installing, testing and commissioning of intelligent Addressible Hooter with necessary accessories etc.
Supplying, installing, testing and commissioning of 2 core x 1.5 sq. mm, Armoured cables FRLS type confirming to IS standards and specifications.
HAND APPLIANCES
Supply of 4.5 KG. Capacity C02 Type Fire Extinguishers.
Supply of 6 KG Capacity ABC Type Fire Extinguishers.
Supply of 09 Ltr. Capacity AFFF Type Fire Extinguishers.
SH: (4) Multi-purpose Hall
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering (a) 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Column, Pillars, Piers, Abutments, Post and Struts.
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
d) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : Local best quality Teak wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Teak wood: 35 mm thick shutters
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing ISI marked oxidised M.S.sliding door bolts with screws etc. complete 250x16 mm
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. (i) Electric resistance or induction butt welded tubes.
Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00mm thick with zinc coating not less than 275gm/m2
Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 0.80mm thick with zinc coating not less than 275gm/m2.
12 mm cement plaster of mix 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
SH: IEI for Multi-purpose Hall
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
Suitable size GI box with modular plate and in front on surface or in recess i/c p/f 6 pin 16/15 amp modular socket outlet 15/16 amp modular switch, connection painting etc as required
S/F suitable size G.l box with modular plate and cover infront on surface or recess i/c p/f 3pin 5/6 amp modular socket outlet 5/6 amp modular switch connection painting etc as reqd.
(1.7) Wiring for circuit/sub-main wiring along with earth wire with the (following size of ) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc. as reqd.
1)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
2)2 x 2.5mm2 + 1 x 2.5mm2 Earthwire
3)2 x 4mm2 + 1 x 4mm2 Earthwire
(1.87) S/F (following way) single pole and neutral, sheet steel MCCB DB 240v on surface/recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connection, pho phatised and power painted including earthing etc. as required (but without MCB/ RCCB/ isolator)
(1.107) S/F 5amp t.o32 amp rating 230V "B" series for lighting and other purposes, load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as required.
(2) Single pole and neutral
(1.109) S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required.
(1.84) P/f (following capacity TP&N) disconnector fuse switch unit inside the exiting cubicle panel board with I.S.l mark HRC fuses i/c drilling holes in the cubicle panel board making connection as reqd.
(2) 400 Amp TP&N
P/F 400Amp TPN stand ground on load on load change own switch (compact design) 415/500v including connection to as required.
S/F Busbar chamber with 4 strips copper busbar of length 600mm sujtable for 200 amps capacity complete with all accessories i/c connection earthing the body as required.
(8.01) S/F 48" sweep (1200mm)a.c ceiling fan complete with down rod canopy, 3 Blades but without regulator etc. as reqd. (Havells or similar 5 star)
305mm sweep exhaust fan complete with all accessories connection etc as required
l.62) S/F stepped type electronic fan regulator on the modular plate witch box i/c connection but excluding modular plate as reqd.
P/F swing wall fan
(1.7 I) S/F brass batten holder i/c connection etc. as reqd.
LED white lamp l 8w
S/F rece s mounting LED down lighter BGSL 0301WH 220225 Cast allumfoiu.m housing fixed with collinated lens 3x I W white lens mounted on MCPCB extruded alluminium heat sink spring loaded mounting clip ,complete with connection etc as reqd.
P/F lighting conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc. Complete as reqd
P/F copper tape 20mmx3mm thick on parapet or surface of waU for lightning conductor as reqd(for vertical run)
SH: WS & SI for Multi-purpose Hall
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm thick.
c) Edges of slabs and breaks in floors and walls: Under 20 cm wide.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (a) Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with utomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board: 510x1040 mm bowl depth 225 mm.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour: 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (a) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: 15 mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet : 250x130x30 mm
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe- 40 mm dia
White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap
Providing and fixing lead caulked joints to 100 mm HCI pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work:
a) 100mm nominal outer dia Pipes
b) 50 mm nominal outer dia Pipes
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15 mm nominal bore.
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. Concealed work, including cutting chases and making good the wall etc.
a) 1216 (16 mm OD) pipe
b) 1620 (20 mm OD) pipe
c) 2025 (25 mm OD) pipe
d) 2532 (32 mm OD) pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work: 50 mm nominal outer dia Pipes
Making connection of G.I. Distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc.complete ; 25 to 40 mm nominal bore
Providing and fixing brass bib cock of approved quality : 20 mm nominal bore code
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 32 mm nominal bore: Horizontal
SH: Land Development for Staff Quarter
Construction of embankment with material obtained from borrow pits (Construction of embankment with approved materials obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
SH: (5) Academic Building
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering (a) 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) RCC Grade M25
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) RCC Grade M25.
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) RCC Grade M25
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Column, Pillars, Piers, Abutments, Post and Struts.
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
d) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness.
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : Local best quality Teak wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Teak wood: 35 mm thick shutters
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing ISI marked oxidised M.S.sliding door bolts with screws etc. complete 250x16 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 1200 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1 : 4 ( 1 cement: 4 coarse sand ) laid and pointing with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer -in - Charge. Polished Granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade using 50% white cement 50% Grey cement.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. (i) Electric resistance or induction butt welded tubes.
Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00mm thick with zinc coating not less than 275gm/m2
Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 0.80mm thick with zinc coating not less than 275gm/m2.
P/F at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at
230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I,
12 mm cement plaster of mix 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats
Finishing walls with Acrylic Smooth exterior paint of required shade : — New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
SH: IEI for Academic Building
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
c) Group C
Suitable size GI box with modular plate and in front on surface or in recess i/c p/f 6 pin 16/15 amp modular socket outlet 15/16 amp modular switch, connection painting etc as required
S/F suitable size G.l box with modular plate and cover infront on surface or recess i/c p/f 3pin 5/6 amp modular socket outlet 5/6 amp modular switch connection painting etc as reqd.
(1.7) Wiring for circuit/sub-main wiring along with earth wire with the (following size of ) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc. as reqd.
1)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
2)2 x 2.5mm2 + 1 x 2.5mm2 Earthwire
3)2 x 4mm2 + 1 x 4mm2 Earthwire
4)2 x 6mm2 + 1 x 6mm2 Earthwire
(1.87) S/F (following way) single pole and neutral, sheet steel MCCB DB 240v on surface/recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connection, pho phatised and power painted including earthing etc. as required (but without MCB/ RCCB/ isolator)
(1.107) S/F 5amp t.o32 amp rating 230V "B" series for lighting and other purposes, load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as required.
(2) Single pole and neutral
(1.109) S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required.
(1.84) P/f (following capacity TP&N) disconnector fuse switch unit inside the exiting cubicle panel board with I.S.l mark HRC fuses i/c drilling holes in the cubicle panel board making connection as reqd.
(2) 400 Amp TP&N
(2) 200 Amp TP&N
P/F 400Amp TPN stand ground on load on load change own switch (compact design) 415/500v including connection to as required.
S/F Busbar chamber with 4 strips copper busbar of length 600mm sujtable for 200 amps capacity complete with all accessories i/c connection earthing the body as required.
(8.01) S/F 48" sweep (1200mm)a.c ceiling fan complete with down rod canopy, 3 Blades but without regulator etc. as reqd. (Havells or similar 5 star)
305mm sweep exhaust fan complete with all accessories connection etc as required
l.62) S/F stepped type electronic fan regulator on the modular plate witch box i/c connection but excluding modular plate as reqd.
P/F swing wall fan
(1.7 I) S/F brass batten holder i/c connection etc. as reqd.
LED white lamp l 8w
S/F rece s mounting LED down lighter BGSL 0301WH 220225 Cast allumfoiu.m housing fixed with collinated lens 3x I W white lens mounted on MCPCB extruded alluminium heat sink spring loaded mounting clip ,complete with connection etc as reqd.
P/F lighting conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc. Complete as reqd
P/F copper tape in horizontal nm p copper tape 2ommxJmm thick on parapet or surface of wall for lightning conductor as reqd(for horizontal run)
P/F copper tape 20mmx3mm thick on parapet or surface of waU for lightning conductor as reqd(for vertical run)
(3.05) Earthing with copper earth plate 600 mmx 600mmx6mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) as reqd.
(3.06) Extra for using Salt & Charcoal for copper plate with electrode as reqd.
Earth connection from earth electrod with 4mm dia in 15mm GI pipe as required
SH: WS & SI for Academic Building
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 50 mm nominal outer dia Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32mm nominal outer dia Pipes
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass
Providing and fixing wh.ite vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 32 mm dia
Providing and fixing 8 mm dia C.P. I S.S. Jet with flexible tube upto I metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. Pan
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge
Providing and fixing CP Brass ingle lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia
Providing and fixing C.P. Brass extension nipple (size l 5mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing toilet paper holder: C.P. brass
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm. 78 mm wide and elfeclive height of88 mm, weighing not less than I 70 gms.
Providing and fixing PTMT liquid soap container I09 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing and fixing mirror of superior glass (of approved quality) and of requiied shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing ; Rectangular shape I 500x450 mm
Providing and fixing P.V.C. waste pipe for sink or wash. basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing UPVC soil waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cernenl, trenching, refilling & testing of joints complete as per direction of Engineer in charge.
a) 110mm dia
b) 75mm dia
Providing and fixing G.L. pipes complete with G.I. fittings and clamps. i/c cutting and making good the walls elc.lntemal work - Exposed on wall
a) 25mm dia
b) 32mm dia
Providing and fixing (G.I Pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc.external work - Exposed on wall
Making connection of G.I. Distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc.complete ; 50 to 80 mm nominal bore
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
Providing and fixing C.P. brass slop cock (concealed) of standard design and of approved make conforming to IS:893 I. : 15 mm Nominal bore
Providing and fixing ball valve (brass) of approved quality High or low pressure with plastic floats complete :
a) 15 mm nominal bore
a) 20 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Supply and fixing self priming single phase (TEXMO or similar brand) of 1HP water pump of approved qualilty.
WATER RESERVOIR
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) RCC Grade M25
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a) RCC Grade M25
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) RCC Grade M25.
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof pl 12mm thick.
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof pl 12mm thick.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
SEPTIC TANK
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Boulder with minimum size of 300mm for pitching at Site
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : (a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof pl 12mm thick.
c) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Providing and fixing C.I Cover frame (for manhole and chambers). (a) 600 mm x 450 mm (heavy duty).
SH: Fire Fighting for Academic Building
FIRE ALARM SYSTEM
Supply,installation, testing and commissioning of intelligent Addressable ionisation type photoelectric & Smoke Detectors with dual chamber solid state design, indicating lamp, mounting base etc. as per detailed specification.
Suppling, installing, testing and commissioning of intelligent Addressible manual pull station with necessary accessories, etc.
Supplying, installing, testing and commissioning of intelligent Addressible Hooter with necessary accessories etc.
Supplying, installing, testing and commissioning of 2 core x 1.5 sq. mm, Armoured cables FRLS type confirming to IS standards and specifications.
HAND APPLIANCES
Supply of 4.5 KG. Capacity C02 Type Fire Extinguishers.
Supply of 6 KG Capacity ABC Type Fire Extinguishers.
Supply of 09 Ltr. Capacity AFFF Type Fire Extinguishers.
SH: Land Development for Academic Building
Construction of embankment with material obtained from borrow pits (Construction of embankment with approved materials obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
SH: (6) Internal Road
SUB-BASE, BASES (NON-BITUMENNOUS) :
By Mix in Place Method: Construction of granular sub-ba e by providing close graded material. spreading in unifonn layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clau e 401. For Grading-I Material.
Wet Mix Macadam: Providing, laying spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- ba e / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
BASE SURFACE COURSE (BITUMINOUS)
Prime Coat: Providing and applying primer coat with bitumen emulsion on prepared urface of granular Ba e including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means.
Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/ granular surface cleaned with mechanical broom.
(a) On granular surface treated with primer and dry & hungry bituminous surface.
(b) On Bituminous surface.
Providing and laying bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared urface with paver finisher to the required grade, level and alignment and rolled as per clauses 50 I .6 and 50l. 7 to achieve the desired compaction. Grading I ( 40 mm nominal size) using VG-30.
Providing and laying bituminous concrete with I 00-120 TPH batch type hot mix plant producing an average output of 75 tonne per hour u ing crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects. Grading - T-19 mm (Nominal Size). - using VG-30.
TRAFFIC SIGNS MARKING AND OTHER APPURTENANCES
Pavement marking with hot applied thermoplastic paints conforming to ASTM D36/BS-3262 (Part - I) as per drawing & Technical Specifications Clause 803. A) Lane/centre line/edge line/ transverse marking and Sqm any other markings
FOOTPATHS AND SEPARATORS
Construction of footpath/separator by providing a 150 mm compacted granular sub base as per clau e 40I and 25 mm thick cement concrete grade Ml 5, over laid with pre-cast concrete tiles in cement mortar I :3 including provi ion of all drainage arrangements but excluding kerb channel.
Meetei Construction Private Limited (BID ID -10531)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Document
0.61 MB
Document
0.49 MB
Document
7.80 MB
Tendernotice_1.pdf
PDF • 0.61 MB
Tendernotice_3.pdf
PDF • 7.80 MB
Tendernotice_2.pdf
PDF • 0.49 MB
Tender Documents
Tender Documents • 0.47 MB
Additional Documents
Additional Documents • 7.78 MB
BOQ_3361.xls
BOQ • 0.67 MB
Additional Documents
Additional Documents • 0.60 MB
Tenderdocument.pdf
Tender Documents • 0.47 MB
NITNotice.pdf
Tender Documents • 0.60 MB
Download all tender documents and submit your bid