Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bideer | |
| 2 | L2₹34.7 L+₹57,419.80 (1.68%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹34.9 L+₹77,393.67 (2.27%)Rejected-Finance BAGGU NALLAH CHAMPA NEAR CHINAR MARKET BATOTE DISTT RAMBAN 182204 J K | BATOTE | RAMBAN | JAMMU AND KASHMIR | 182204 | L3 | Rejected-Finance Being other than L1 bidder |
| Sl No | Description | Qty | Unit | VIJAY KUMAR SURI AND SONS L2 | M/S IMRAN MAJID L3 | KANWAL KUMAR GUPTA L1 |
|---|---|---|---|---|---|---|
| 1.00 | Sch 'A' Part-I (B/R works)
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area outside MOD land as own arrangement by contractor and providing following :-
(a) Rendering 10mm thick in cement mortar 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement.
(b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried.
(c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface.
(d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm & minimum 3mm thick reinforced with polyster non wove fabric, APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. APP membrane shall be laid by auth applicator only
(e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat.
Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed. | 390.8 | Sqm | 580 ₹2,26,664 Lowest | 600 ₹2,34,480 | 850 ₹3,32,180 |
| 2.00 | M&L for PCC (1:2:4) type B-O (using 12.5mm graded aggregate stone aggregate) as in roof kerbs or mud stops,levelling course,pedding rounded or chamfered on edges including demolitin of existing and removing outside the MOD land, complete all as specified and directed. | 18 | Cum | 4,500 ₹81,000 | 4,500 ₹81,000 | 2,000 ₹36,000 Lowest |
| 3.00 | Demolition of Brickwork or stone/ boulder masonry, for portions ordered to be dismantled , built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removing materials outside the MOD land, complete all as specified and directed. | 45.1 | Cum | 20 ₹902 Lowest | 100 ₹4,510 | 100 ₹4,510 |
| 4.00 | M&L for Walling of Random rubble uncoursed well bonded, bedded and solidly hearted built CM 1:6, complete all as specified and directed. | 37 | Cum | 2,000 ₹74,000 Lowest | 2,500 ₹92,500 | 2,000 ₹74,000 Lowest |
| 5.00 | All as per Item No 4.00 here-in-before but except Stone. | 10 | Cum | 1,500 ₹15,000 Lowest | 2,500 ₹25,000 | 1,500 ₹15,000 Lowest |
| 6.00 | M&L for PCC (1:2:4) type B-O (using 12.5mm graded aggregate stone aggregate) in cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates,including weathering, slightly rounded or chamfered angles, throating and hold fast, complete all as specified and directed. | 3.9 | Cum | 5,000 ₹19,500 | 5,000 ₹19,500 | 4,500 ₹17,550 Lowest |
| 7.00 | M&L for Brick work with sub class 'B' old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6, complete all as specified and directed. | 2.6 | Cum | 7,000 ₹18,200 | 6,500 ₹16,900 | 5,500 ₹14,300 Lowest |
| 8.00 | All as per Item No 7.00 here-in-before but except bricks. | 1 | Cum | 2,500 ₹2,500 Lowest | 4,500 ₹4,500 | 3,500 ₹3,500 |
| 9.00 | Taking down cement plaster on brick/stone or conc surfaces including racking out joints hacking for key to any thickness scrubbing down with water including removing materials outside the MOD land, complete all as specified and directed. | 1,450.27 | Sqm | 50 ₹72,513.5 | 1 ₹1,450.27 Lowest | 10 ₹14,502.7 |
| 10.00 | M&L for 15 mm thick rendering in cement mortar (1:6) on faces of stone wall/ concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified and directed. | 320 | Sqm | 100 ₹32,000 Lowest | 180 ₹57,600 | 200 ₹64,000 |
Tender Value
₹43.3 L
EMD Value
₹86,600
Closing Date
11 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-914862 c/o 56 APO
SPL REPAIR TO BLDG NO P-13 (ESH-11) AT AP-252 OF 25 INF DOU AND BLDG NO T-24 AND P-05 AT 41 FD REGT AT RAJOURI UNDER AGE BR DETT-III OF GE 862 EWS
2026_MES_749447_1
GER-91/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per NIT
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹86,600
Yes
23 Mar 2026
21 Jan 2026
14 Feb 2026
21 Jan 2026
11 Feb 2026
5 Feb 2026
Sch 'A' Part-I (B/R works) Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area outside MOD land as own arrangement by contractor and providing following :- (a) Rendering 10mm thick in cement mortar 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm & minimum 3mm thick reinforced with polyster non wove fabric, APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. APP membrane shall be laid by auth applicator only (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat. Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed.
M&L for PCC (1:2:4) type B-O (using 12.5mm graded aggregate stone aggregate) as in roof kerbs or mud stops,levelling course,pedding rounded or chamfered on edges including demolitin of existing and removing outside the MOD land, complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, for portions ordered to be dismantled , built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removing materials outside the MOD land, complete all as specified and directed.
M&L for Walling of Random rubble uncoursed well bonded, bedded and solidly hearted built CM 1:6, complete all as specified and directed.
All as per Item No 4.00 here-in-before but except Stone.
M&L for PCC (1:2:4) type B-O (using 12.5mm graded aggregate stone aggregate) in cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates,including weathering, slightly rounded or chamfered angles, throating and hold fast, complete all as specified and directed.
M&L for Brick work with sub class 'B' old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6, complete all as specified and directed.
All as per Item No 7.00 here-in-before but except bricks.
Taking down cement plaster on brick/stone or conc surfaces including racking out joints hacking for key to any thickness scrubbing down with water including removing materials outside the MOD land, complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar (1:6) on faces of stone wall/ concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar (1:4) on faces of stone wall/ concrete surfaces of walls, finished even & smooth without using extra cement with using water proofing compound, complete all as specified and directed. Note- Water Proofing Compound measured separately.
Supply only liquid water proofing compound conforming to IS, complete all as specified and directed.
M&L for rendering 5 mm thick in cm 1:3 over/soffit of chajja, ceilings etc finished surface even and smooth with out using extra cement, complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying 3 coats of white wash on walls, complete all as specified and directed.
M & L for applying two or more coats of100% premium acrylic emulsion paint having VOC less than 50 gm /litre and UV resistance as per IS 15489:2004 alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces, complete all as specified and directed.
M&L for white washing 3 coats on newly plastered surface of ceiling including preperation of surface, complete all as specified and directed.
M&L for complete removal of existing treatment on wall/roof surface including preparation cornices and chajjas etc and applying two coats of white wash, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thick and removal of debris from site including removing materials outside the MOD land, complete all as specified and directed.
M&L for cement concrete work (PQC) in pavement/hard standing of flexural strength 40 kg/sqcm in field using 400 kg of cement per cum, complete all as specified and directed.
M&L for Forming 12 mm thick Expansion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ in 200 mm thick Concrete Slab, complete all as specified and directed.
M&L for Forming Contraction (Dummy) joints 30mm deep x 10mm wide, filled with sealing compound, complete all as specified and directed.
M&L for 75 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring, finished even and fair without using extra cement, complete all as specified and directed.
M & L for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of primer red oxide primer including preparation of surfaces, complete all as specified and directed.
Providing and injecting chemical emulsion for post constructional Anti Termite Treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 liters per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed.
M& L for providing kota stone slab flooring 18-20 mm thick over and including 20 mm thick screed in cement mortar 1:3 and jointed with grey cement slurry mixed with pigment including cutting, complete all as specified and directed.
M& L for providing kota stone slab 18 -20 mm thick in riser of steps, skirting, dado and pillar including 15 mm thick screed in cm 1:3 and jointed with grey cement slurry mixed with pigment including cutting, complete all as specified and directed.
M&L for providing and injecting chemical emulsion for post constructional Anti Termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors, complete all as specified and directed.
Taking down chowkhat with shutter (without taking off shutter from the frame) n. exc 1.5 sqm, complete all as specified and directed.
S & F steel ventilator with top hung shutter including hinges and steel peg stay, complete all as specified and directed.
Dismantling structural steel work including welded fabricks frames, doors, gates and frame truss etc, complete all as specified and directed.
S&F framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc., complete, by using Fe 410-W (Gde E-250) quality a drilled for mixing of steel sheetion or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (including 1.6 mm th MS plain back steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing, complete all as specified and directed.
S &F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
M & L for Cutting holes in brick walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1, complete all as specified and directed.
Taking down steel door of any size and refixing in the same opening after minor repairing, complete all as specified and directed.
Extra over stone walling(40 MM) for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses, complete all as specified and directed.
M&L for raised pointing (CM 1:3) to random or polygonal rubble, uncoursed or brought upto courses, complete all as specified and directed.
Taking down chowkhats or frame exc 1.50 and not exc 4 sqm each with shutter (without taking off shutters from the frame), complete all as specified and directed.
M&L for 20mm thick rendering in cement mortar (1:6) in two coats (1st coat shall be 15mm thick and 2nd coat shall be 5mm thick) on new faces of brick/ concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified and directed.
M&L 20 mm thick rendering in cement mortar (1:4) in two coats (1st coat shall be 15mm thick and 2nd coat shall be 5mm thick) on new faces of stone wall/ concrete surfaces of walls, finished even & smooth without using extra cement and using water proofing compound, complete all as specified and directed. Note- Water Proofing Compound shall be measured separately.
M&L for preparation of New plastered surface of walls and applying two coats of oil bound distemper. complete all as specified and directed.
M&L for Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) 75 mm thick as in plinth protection, finished even and fair ,laid in alternate bays including providing 6 mm wide joints through out the thickness of plinth protection in concrete bays and in between walling and plinth protection,joint filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and directed.
M&L for providing & fixing of 4mm thick designer ceiling board (Make : Everest/Ramco/Everest) in ceiling fixed with screw as per manufactures instructions, laid on hot dipped galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick galvanized steel sheet & of size 24x32x300mm and spaced at 12mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 3 mm dia to be fixed by approved rowl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200 long cross tee with (double stitching) to be inter locked between main runners at 600mm centre to from 1200x600mm modules cross tee longer than 600mm modules to be formed by fitting 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanized steel of size 19x19mm and 300mm long of white colour all as per instruction, complete all as specified and directed.
M&L for steel as in Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
M&L for factory made 100% Solid WPC Door Frame 90mm x 45mm Single Rebated made from Wood Polymer Composite ( Single Extruded Section Process) Material comparising of virgin PVC polymer of K value 57-60 ( suspension Grade), Calcium Carbonate and Natural Fibres ( Wood Powder/Rice Husk/Wheat husk) and Non toxic additive fabricated with frame density of 780 Kg/cbm & manufactured by "RAJSHRI" an ISO 9001-2015 Certified Company, having good screw holding capacity ( Screw Withdrawl Strength of Min. 900N),Minium Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of required dia and length, all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company, complete all as specified and directed.
M&L for Factory made 30mm thick 100% Solid WPC Laminated Moulded Door Shutter of required size comprising of virgin PVC resin of K value 57-60 (Suspension Grade), Calcium Carbonate and Natural Fibres ( Wood Powder/Rice Husk/Wheat husk) and Non toxic additive, made from Extrusion process WPC foam sheet Single Extruded (inner) with having minium density not less than 650 Kg/cbm manufactured by "RAJSHRI" an ISO 9001-2015 Certified Company,having good screw holding capacity ( Screw Withdrawl Strength of 2000N(face) & 1100N (Edge), Minium Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof & Fire retardant. WPC to be laminated with PVC foil of minium 14 micron thick of approved design pasted on both faces of shutter & Fixing Stainless Steel Butt Hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company, complete all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification & drawing, complete all as specified and directed.
S&F for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified and directed.
S & F 100 mm long stainless steel butt hinges, medium weight cold rolled, complete all as specified and directed.
S & F 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm long Extruded Aluminium anodised alloy handles, fabricated type, complete all as specified and directed.
S&F aluminium alloy anodised sliding door bolt with fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed of size 200 mm, complete all as specified and directed.
S&F Factory made MS tubular Box type window/ventilator of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer, openable frames shall be fabricated of sections as approved by Engr-in-Charge corner welded to form a solid fused welded joint handles shall be of z section welded with openable frame box steel section(Consisting of both shutter glazed shutter and gauge shutter complete) used in outer frame shutter frame and central frame shall be ERW section of 16 gauge with fixing lugs to be fixed as per provision of IS-1038 except that top lugs shall not be provided , all shutters of windows shall be provided with 4 Nos friction free hinges, 2 Nos 75 mm tower bolts to each leaf of window one at top and one at bottom welded on 3 mm thick steel sheet piece of suitable size which shall be in turn welded to z section f steel window to provide suitable arrangement of using tower bolt and 1 nos bow handle in each shutter. Glazed shutter and , gauged shutter of window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures without glazing bars, 3mm sheet glass in glazed shutter and , GI wire mesh,of 0.56 nominal dia and average width of aperature 1.18 mm in gauged shutter, complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding ( but not backing ), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450 x 350 x 7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and incluidng 15mm thick rendering in CM (1:4), complete all as specified and directed.
M&L for 25mm thick PCC type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in subbase/ levelling course, complete all as specified and directed.
M&L for Non-skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings sheets in roof, complete all as specified and directed.
S&F of Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour (multi colour pattern as approved by GE) having tensile strength of 550 Mpa as in roof covering/ cladding to wall and curved roof surfaces fixed with self tapping screws, complete all as specified and directed.
S&F of Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour (multi colour pattern as approved by GE) having tensile strength of 550 Mpa as in ridge fixed with self tapping screws, complete all as specified and directed.
S & F Rolled mild steel in Roof trusses (framed), trussed, purlins,(Fe crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of grade Fe 410-W (Gde-E-250) quality-A, complete all as specified and directed.
Dismantling of mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F in repair Vitreous China Wash hand basin white, flat back of size 630 x 450mm size including pedastal pattern screwed for iron pipe and Waste fitting coupling 32mm dia brass chromium plated and 750mm long 32mm dia PVC waste pipe, complete all as specified and directed.
S&F in repair for brass CP soap dish incl brass CP screws and wooden cleats, complete all as specified and directed.
Supply only 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed.
S & F in repair vitreous china squatting pan, orissa pattern size 680 x 470 mm white/colour with integral foot rest (excluding flushing cistern and flush pipe) including provison of lime concrete, complete all as specified and directed.
S&F in repair for vitreous china urinals, half stall type Premium quality including flush pipe including PVC waste pipe, speader, grating and outlet, complete all as specified and directed.
S & F in repair for 15mm bore chromium plated bib tap, cast coper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F rotational moulded polythene water storage tank (Cylindrical vertical withclosed top)hoisted and fixed in position of 1000 ltrs capacity fixed with PVC tank nipples, complete all as specified in SSR Part I including dismantling of existing tank and removing to store, complete all as specified and directed.
S&F in repair CP grating suitable for 100 mm bore floor trap and fixed with white cement, complete all as specified and directed.
S & F in repair for of 15 mm bore fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
S&F in repair for 15mm bore Angle Stop valve, fancy type, heavy duty, cast copper alloy, chromium plated, screwed down and screwed for iron pipe, complete all as specified and directed.
S&F in repair for 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
S&F in repair for 110mm PVC (SWR) bends any radius, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers notexceeding 25 cm in soft/ loose soil, complete all as specified and directed.
M&L for PCC type B-2 (1:2:4) (using 40 mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
M & L for Hardcore of guage exc 63 mm but n exc 100 mm,(broken stone or boulders) deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled/rammed to a true surface, complete all as specified and directed.
M&L for pre polished coloured chequred cement concrete tiles of size 30 cm X 30 cm x 25 mm thick set,jointed in neat cement slurry in floor and pointed with grey cement and no pigment laid over and including 15 mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials for taking credit (credit for above items should be amde as per conditions seperately) and making good the disturbed surface of walls, floor or ceiling etc to match the existing specification, complete all as specified and directed.
M&L for point wiring with two single core 1.5 sqmm (nominal cross section area FRLS PVC insulated unsheathed copper conductor cable and one single core 1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed 1100 Volts, grade multi stranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including medium grade rigid non metalic PVC concealed conduit in wall after cutting chases in wall including cast iron or pressed steel terminal box covered with and including 3mm thick bakelite sheet top cover fixed flush with wall using brass screws, washers and all requisite accessories such as PVC elbow, Tee, collars, bends etc for mounting switches, socket, fan regulators etc for one light/ fan exhaust fan point controlled by one way switch 6 Amp, complete all as specified and directed. Note: The colour coding of wiring to be followed as Red/ Yellow/ Blue Phase/ Neutral/ Earth respectively.
All as per Item No 81.00 here-in-before but for socket outlet 5 Amp on same board.
All as per Item No 81.00 here-in-before but for socket outlet 5 Amp on independent board.
All as per item No 81.00 here-in-before, but for one 3 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistranded copper cable with 2.5 sqmm single core multistranded FRLS copper cable as earthling lead, complete all as specified and directed.
M&L for switch piano flush type 5 Amps SP one way 230 volts, complete all as specified and directed.
M&L for socket outlet 2 in 1, 5 Amps, 5 Pin, flush type, 230 volts, complete all as specified and directed.
S&F for switch socket combination 2 in 1, 15 Amps, 5 Pin, flush type, 230 volts, complete all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
M&L in replacement for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height, complete all as specified and directed.
S&F in replacement LED luminaire 600 x 600 mm, 36 watt, 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivber, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed.
Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod and electronic regulator alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable, complete all as specified and directed.
M&L for sheet metal enclosure MCB distribution board, double door SPN with IP-66 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete, including removing old/unsv MCB DB, complete all as specified and directed. Note:- MCBs shall be measured separately.
M&L for sheet metal enclosure MCB distribution board, double door SPN with IP-66 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete, including removing old/unsv MCB DB, complete all as specified and directed. Note:- MCBs shall be measured separately.
M&L for MCB single pole and neutral 240 volts any rating upto 32 Amps, with rupturing capacity 10 KA,including providing thimble for out going cables, including removing old/unsv, complete all as specified and directed.
S&F for MCB single pole 240 volts any rating upto 5 to 32 Amps, with rupturing capacity 10 KA, 'B' curve in the DB, including providing thimble for out going cables, including removing old/unsv, complete all as specified and directed.
Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft/ loose soil, complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm, complete all as specified and directed.
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for paymeny purpose.
M&L for sub class 'B' bricks old size, laid dry flat over the cable abutting each other, length of cable equal to width of brick, complete all as specified and directed.
M&L for air termination, single pointed copper rod, 12mm dia, 300mm long fixing over the GI tube with the clamps after taking out old/ unserviceable one, complete all as specified and directed.
S&F or embeded in to the PCC, Tubes medium grade galvanised, with all fittings 25mm dia after taking out old/ unserviceable one, complete all as specified and directed.
M&L for Cement Concrete 1:3:6 type C1 (using 20mm grade curshed stone aggregate) as in bed blocks for holding GI pipe on roof top surface etc including necessary formwork, complete all as specified and directed.
M&L for MS clamps made out of 25x6mm flat orn for holding/ supporting of pipe for cable on poles, including bolts, nuts and washers, MS plates minimum 3mm thick drilling holes and painting with two coats of synthetic enamel bituminus paint over a coat of red oxide primer, complete all as specified and directed.
M&L for Test point terminal block made of gun metal/ phosphorus bronze of size 75 x 75 x 25mm drilled and screwed including 3 Nos, 8mm dia, 25mm long hex head screw fixed, complete all as specified and directed.
M&L for copper strip of size 20x3.15mm burried in ground or fixed on walls/ floor with suitable saddles and screws beyond 7.5mtr of each lead connecting with test point after taking out old/ unserviceable one, complete all as specified and directed.
M & L for earthing with copper earth plate electrode 600mm x 600mm x 3.15 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to connected to the connecting copper strip 20 x 3.15mm and inclding GI pipe 40mm dia light grade for protection to the extend of 7.5mtr as earthing lead by means of copper nuts, bolths as per connecting to equipment with provn charcol and salt complete all as per electric plate No 3 of SSR Part-I including PCC chamber with RCC cover watering arrangement with GI pipe 20mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion, complete all as specified and directed.
M & L in replacement for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 including GI pipe 15 mm dia light grade for protection to the extend of 7.5 mtr as earthing lead connecting to equipment with provn charcol and salt complete including PCC chamber with RCC cover watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion complete.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
TD.pdf
Tender Documents • 1.02 MB
BOQ_839339.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .