| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC | ₹34.7 L Quoted ₹37.1 L | L1 | Accepted-AOC Lowest bid. |
| 2 | L2₹38.1 L+₹1.0 L (2.71%)Rejected-Finance | ₹38.1 L+₹1.0 L (2.71%) | L2 | Rejected-Finance Other than lowest bid. |
| 3 | L3₹38.8 L+₹1.7 L (4.64%)Rejected-Finance | ₹38.8 L+₹1.7 L (4.64%) | L3 | Rejected-Finance Other than lowest bid. |
| 4 | L4₹38.9 L+₹1.8 L (4.83%)Rejected-Finance | ₹38.9 L+₹1.8 L (4.83%) | L4 | Rejected-Finance Other than lowest bid. |
| 5 | L5₹39.5 L+₹2.4 L (6.39%)Rejected-Finance | ₹39.5 L+₹2.4 L (6.39%) | L5 | Rejected-Finance Other than lowest bid. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Sept 2024, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT-145001
CERTAIN REPAIR TO ROOFS, PARAPETS ROOF SHEET AND FALSE CEILING ETC IN AOR UNDER AGE B/R II OF GE (S) MAMUN
2024_MES_664591_1
GE(S)/M-33/2024-25
Open Tender
Miscellaneous Works
Item Rate
270 days
GE SOUTH MAMUN
AS PER NIT
10 documents required · 10 mandatory
₹500
GE SOUTH MAMUN
₹90,000
Yes
14 Nov 2024
9 Jul 2024
11 Sept 2024
9 Jul 2024
4 Sept 2024
23 Jul 2024
Amount
S&F in repairs pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including dismantling of existing asbestos sheets of any type and any description, complete all as specified and directed.
S&F in repairs pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick and 600mm width of an ecofriendly colour having tensile strength of 550 Mpa as in ridge/vally, fixed with self tapping screws as specified including dismantling of existing asbestos sheets of any type and any description, complete all as specified and directed..
M&L in repairs for false ceiling of 7 to 8 mm thick gypsum tiles (600x600mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or coloured) fixed using T grid/Cross-T/Wall angle/level clip & suspenders / hangers 4.00 mm dia GI wire (upto 120mm length) adjusting level fixed to roof slabs/ trusses of standard galvanised sections in a grid size of 600x600mm, including taking down existing ceiling board & grid work etc of any type/pattern complete all as specified and directed.
S&F tubular framed steel trusses (all as per pattern of existing dismantled trusses) made out of MS medium grade tube (ERW or induction butt welded ) conforming to I. S.1161-1979 grade St.-240 quality 'A', including welding of distance pieces, cleats, special shaped washer etc. and applying two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) for fixing to trusses, as in coping, benching, slope including demolition of existing pcc etc., complete all as specified and directed.
M&L for brick work with old size fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 including demolition of existing brick work complete all as specified and directed.
M&L for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint , complete all as specified and directed.
M&L for preparation of newly or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L for preparation of old wood & wooden based surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
S&F for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with 'L' or 'J' hooks, including dismantling of existing asbestos sheets of any type and any description, complete all as specified and directed..
M&L for plain cement concrete 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregate), as in roof kerbs, mud stops, rounded or chamfered on edge at the junction of roofing to verticle surface including demolition of existing concreteurfaces, complete all as specified and directed.
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe 290 Gde-E-165 (Brackets over 10 kg each, complete all as specified and directed.
S&F in repairs 4 to 6mm thick non asbestos fibre cement building boards fixed or laid on GI frame work comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centr/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspeneded from soofit at approx 900mm centre to centre with GI cleat and steel expansion fastenerswith and including ceiling section(not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips accross the intemediate channel at 457mm centre to centre fixed with hangers 6mm dia.GI(upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flate 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L for rendering 10mm thick plaster on faces of brick work or concrete surfaces of walls in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick plaster on faces of brick work or concrete surfaces of walls in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick plaster work in CM 1:3 on fascia or edging of chajjas, ceiling and roof projections etc. including taking out peeled off existing plaster / concrete including roughening old concrete surface and making the line in true shape and finishing the surface without using extra cement, complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oilbound distemper over one coat of chalk whiting, complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall and applying two coats of cement base paint over a coat of alkali resistant primer including curing, complete all as specified and directed.
M&L for preparation of newly plastered surface of fascia/edging/ceiling of chajjas, roof projection and applying two coats of cement base paint over a coat of alkali resistant primer on including curing, complete all as specified and directed.
Taking down roof trusses,exc 4mtr but n.exc 8mtr coupled rafters or trussed beams complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Removing existing existing roof treatment (any type) roughening the surface of old concrete by picking, sweeping/brushing clean and washing down with water to remove dust and applying neat cement slurry with 3.0 Kg of cement per Sqm, including removal of debris in low laying area exc 1.0 KM but not exc 2.0 KM from starting point, complete all as specified and directed.
M&L for 20mm thick cement plaster on concrete surfaces of roof top in cement mortar 1:4 finished even and smooth without using extra cement mixed with and including WPC liquid @ 0.200ltr/ 50 Kg bag of cement, complete all as specified and directed.
M&L for APP modified roof treatment over existing non-accessible RCC roof slab / chajjas / canopy / parapet wall, to be executed through approved applicator of the membrane manufactured with following specifications, complete all as specified and directed :- (a) Cleaning the top surface of RCC roofing properly with water. (b) Applying oil bound bitumen primer @ 0.30 Litre / Sqm, manufactured by the same agency as that of APP with a density 0.87-0.89 KG / Litre at 25 degree centigrade on prepared surface. (c) Laying of membrane not less than 3.0mm thick APP modified water proofing membrane weighing not less than 3.60 KG/Sqm reinforced with non woven polyster fiber weight not less than 160 Gms/Sqm using butane torch by torch application with 10cm overlap and 15cm end lap. (d) Top of membrane shall be provided with solar reflective bituminous aluminum paint @ 0.10 KG / Sqm as prescribed by manufacturer of membrane. (e) APP Membrane shall be stick inside parapet where available by chase cutting and sealed with PCC 1:2:4, type B-0. (f) Top of membrane shall be provided with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
S&F in repairs 20 mm thick brick tiles laid on 15 mm thick cement morter (1:6) and joints grouted flush in cement morter (1:3) mixed with 5% of crude oil by weight of cement over APP membrane incl dismantling of existing bricks / tiles etc. complete all as specified and directed.
D S INFRASTRUCTURE AND DEVELOPERS (BID ID -3077522)
M/S NARESH KUMAR SHARMA (BID ID -3081717)
Abrol construction co (BID ID -3083121)
dadwal engineers (BID ID -3082641)
Bidder Name
dadwal engineers
Abrol construction co
M/S TARA CHAND CONSTRUCTION CO.
D S INFRASTRUCTURE AND DEVELOPERS
M/S NARESH KUMAR SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .