Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.9 LAccepted-AOC | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹22.5 L+₹2.2 L (11.0%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹23.6 L+₹3.4 L (16.6%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹26.0 L+₹5.7 L (28.4%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹26.5 L+₹6.2 L (30.8%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PALAM
GE (AF) PALAM DELHI CANTT-10
REPAIR/ MAINTENANCE OF LT UG CABLES AND CONNECTED ITEMS AT AF STN PALAM UNDER GE (AF) PALAM DELHI CANTT-10
2023_MES_627402_1
GENP-60/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹60,000
Yes
25 Jan 2024
8 Nov 2023
8 Dec 2023
8 Nov 2023
6 Dec 2023
23 Nov 2023
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep or not exc 10 Sqm on plan and getting out for taking out/laying cable etc complete.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid and tested.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and to be achieved 18cm thickness after punning complete.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete.
Laying only old serviceable bricks complete all as specified.
Taking out old unserviceable LT under ground cable any type from trenches, pipes & poles complete all as specified.
Supply, laying and testing for XLPE insulated LT armoured under ground cable 1100 Volt grade with stranded aluminium conductor of size 16 Sqmm 4 Core as in trenches /passing through pipes/ on poles etc complete all as specified.
All as per item No 8 above but 25 Sqmm 3.5 core.
All as per item No 8 above but 35 Sqmm 3.5 core.
All as per item No 8 above but 50 Sqmm 3.5 core.
All as per item No 8 above but 70 Sqmm 3.5 core.
All as per item No 8 above but 95 Sqmm 3.5 core.
All as per item No 8 above but 120 Sqmm 3.5 core.
All as per item No 8 above but 150 Sqmm 3.5 core.
All as per item No 8 above but 185 Sqmm 3.5 core.
All as per item No 8 above but 240 Sqmm 3.5 core.
M&L in repair galvanised steel tubing, light grade with all fittings laid in trenches or laid in floors of 150 mm bore all as specified.
All as per item No 18 above but 100 mm bore
All as per item No 18 above but 80 mm bore
All as per item No 18 above but 50 mm bore
All as per item No 18 above but 40 mm bore
M&L for augering of holes in true horizontal position under road /pavement by means of mechanical rig after doing ultrasound technique to prevent any damage to existing cables/pipe lines coming in route 1.5 Mtr deep and not exceeding 50 Mtrs long including laying HDPE pipe of 150mm dia complete all as specified and as directed by Engr-in-Charge
S&F for MCCB 400 Amps 4 pole 36 KA 415 Volts 50 Hz with thermal and magnetic adjustable settings including taking out old existing unserviceable MCCB from panels etc complete.
All as per item No. 24 here in before but 315/350 Amps 36 KA .
All as per item No. 24 here in before but 250 Amps 36KA.
All as per item No. 24 here in before but 200 Amps 36 KA.
All as per item No. 24 here in before but 160 Amps 36 KA .
All as per item No. 24 here in before but 125 Amps 16 KA .
All as per item No. 24 here in before but 100 Amps 16 KA.
All as per item No. 24 here in before but 63 Amps 16 KA .
Supply & jointing in repair heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 400/500 Sqmm 3.5 core complete with treating of cable to make ready for jointing etc complete. Make : 3M/ Denson/ Reychem.
All as per item No. 32 here in before but suitable for cable size 240 to 300 Sqmm.
All as per item No. 32 here in before but suitable for cable size 150 to 185 Sqmm.
All as per item No. 32 here in before but suitable for cable size 70 to 120 Sqmm.
All as per item No. 32 here in before but suitable for cable size 25 to 50 Sqmm.
Demolition of cement concrete in PCC poles/steel tubular poles, struts etc of any size all as specified.
S&F in repalcement of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.00 meter long complete
S&F in replacement of lugs/thimbles at termination of LT cable by cutting the end portion and removing insulation and fixing new aluminium lugs /thimble properly with crimbing tool of size 185 to 400 Sqmm complete
All as per item No. 39 here in before but for cable size 50 to150 Sqmm
All as per item No. 39 here in before but for cable size upto 35 Sqmm
Cutting and trimming of tree branches on any type of surface and height to clear OH lines in the area of LT OH lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of tree) and removal of the trimmed branches of trees and depositing the same where directed including providing the necessary ropes/cutting tools, safety equipment like helmet etc as per safety norms (IE Rules) all as specified and directed by Engr-in-Charge.
Material and labour for preparation of old painted / rusted surfaces of steel tubular LT pole 9 mtr long inculding cross arms and clamps of any size and applying one coat of aluminum paint (1st quality) including white /blue 30 cm wide strip upto the height of 1.5 mtr above ground level and marking the pole No in 4” dia yellow paint complete all as specified and directed by Engr-in-Charge
M&L for painting to concrete poles of any type and any size with a coat of synthetic enamel paint with white /blue30 cm wide strip upto the height of 1.5 mtr above ground level and marking the pole No in 4” dia yellow paint circle complete all as specified and directed by Engr-in-Charge.
S&F in repair mild steel chequered/ mild steel plates duly painted with two coat of black bituminous paint over one coat of red oxide primer and cut to shape, welding etc for cable duct complete all as specified.
S&F in replacement of old display board for showing details of Power House and Transformer /SOPS/layout of HT , LT UG cables and VCBs/RMUs as per installation duly printed both verison English and Hindi computerized letter Made of PVC sheet of 1.5 Mtr x 1 Mtr including GI angle frame and GI sheet cover to the frame and fixing of 2 Nos LED tube light fittings 20 Watts. connecting electrical supply to the glow sign including grouting in suitable PCC foundation 1:2:4 type B-1 fixed 0.45 mtr below GL and 1.2 Mtr above ground level complete all as specified and directed by Engr-in-Charge. (Note:- Details of each glow sign borad will be provided by Engr-in-Charge).
M&L for defect rectification LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 400 Sq mm 3.5 core. The fault locating equipments will be brought by the contractor to site within the hours of instruction from Engr-in-Charge
S&F in replacement of Vertical type load line distribution board, double door, 8 ways, AC 3 Phase, 415 volts, TPN, bus bar 200 Amps rating and earth bus & din rail suitable for MCCB as incomer complete including cutting chasing the existing wall for fixing the DB and making good the disturbed surface of wall and matching with existing surface of wall and making cable connection with suitable size lugs, making electrical connections of existing submain/circuit wiring, earth wire all as specified and directed by Engr-in-Charge.
Supply and fixing in replacment of MCCB 125 Amp, 3 pole,10KA complete.
Supply and fixing in replacement of MCB TP 63A, 10KA, 415 Volts 50 Hz 'C' series. complete all as specified.
Supply and fixing in replacement of MCB SPN 40A, 10KA, 230 Volts 50 Hz 'C' series. complete all as specified.
Supply and fixing in replacement of MCB SP 6-32A, 10KA, 230 Volts 50 Hz 'B' series. complete all as specified.
M&L in replacement of Junction box outdoor type, 3 phase 415 Volts of size 350x250x150 mm made out of hot press moulded SMC front openable hinged type including 4 Nos. Al bus bars mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmps, nuts, bolts etc of size 25 x 4 mm duly painted with two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed by Engineer-in -charge.
M&L in replacement of Junction box outdoor type, single phase 230 Volts of size 300x200x105 mm made out of hot press moulded SMC front openable hinged type including 2 Nos. Al bus bar mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmp, nuts, bolts etc of size 25 x 4 mm duly painted with two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT panel is deemed to be included in the quoted rate ) INCOMING (i) MCCB 400A 4 pole ,35KA with adjustable thermal & adjustable magnetic setting - 1 No (ii) Digital Multi functional meter VAFPP (voltage , current , frequency,power factor) - 1 No. (iii) Phase indicator lamp (LED type) - 1 Set.(set of three) OUT GOING:- (i) MCCB 250A 4 pole ,25 KA with adjustable thermal & fixed magnetic setting – 02 Nos (ii) MCCB 160A ,4 pole ,16 KA with adjustable thermal & fixed magnetic setting -02 Nos (iii) MCCB 100A ,4 pole ,10 KA with adjustable thermal & fixed magnetic setting -02 Nos Make of MCCB : Havells/ Legrand/ C&S
S&F in replacement of out door type LT feeder pillar box (KIOSK) platform mounted, suitable for 3 phase, 4 wire, 415V, 50 Hz AC supply system, factory made and tested (incl CPRI type test certificate) having bus bar chamber with insulated aluminium busbars 400 Amps rating insulated on porcelain insulators, The panel shall be dut and vermin proof, IP 65 class protection and made out of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (freedom) lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor FRLS cable, IS -694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:- (a) INCOMING (i) MCCB 250A 4 pole ,25 KA with adjustable thermal & fixed magnetic setting – 1 No (ii) Digital Multi functional meter VAFPP (Voltage,current,frequency,power factor,meter)- 01 No (iii) Phase indicator lamp (LED type) - 01 set of three (b) OUT GOING (i) MCCB 160A ,4 pole ,16 KA with adjustable thermal & fixed magnetic setting -02 Nos (ii) MCCB 100 A ,4 pole ,10 KA with adjustable thermal & fixed magnetic setting -02 Nos Make of MCCB : Havells/ Standard/ C&S
Supply and fixing in replacement of outdoor type cubical Feeder pillar box 1000x800x500mm size suitable for 3 phase, 4 wire, 415Volt, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof IP 65 class protection and the panel should have 800 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame 40mmx40mmx6mm (angles duly painted with two coats of synthetic enamel paint with one coat of red oxide primer) and front opening type, with aprons for cable entry, with double door shutter and locking arrangement with MCCB 400 Amp 4 pole 36 KA as incoming including terminating the existing incoming and outgoing cables etc including PCC foundation in 1:2:4 type B-1 complete all as specified and directed by Engineer -in-charge.
Supply and fixing in replacement of outdoor type cubical Feeder pillar box 750mmx500mmx450mm size suitable for 3 phase, 4 wire, 415Volt, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof IP 65 class protection and the panel should have 400 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame 40mmx40mmx6mm (angles duly painted with two coats of synthetic enamel paint with one coat of red oxide primer) and front opening type, with aprons for cable entry, with double door shutter and locking arrangement with MCCB 250 Amp 4 pole 36 KA as incoming including terminating the existing incoming and outgoing cables etc including PCC foundation in 1:2:4 type B-1 complete all as specified and directed by Engineer -in-charge.
Supply and fixing in replacement of outdoor type cubical Feeder pillar box 600x500mmx450mm size suitable for 3 phase, 4 wire, 415Volt, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof IP 65 class protection and the panel should have 300 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame 40mmx40mmx6mm (angles duly painted with two coats of synthetic enamel paint with one coat of red oxide primer) and front opening type, with aprons for cable entry, with double door shutter and locking arrangement with MCCB 160 Amp 4 pole 25/36 KA as incoming including terminating the existing incoming and outgoing cables etc including PCC foundation in 1:2:4 type B-1 complete all as specified and directed by Engineer -in-charge.
M&L in repair earthing with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 25mm x 6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel including concrete chamber with PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish internal surface of concrete chamberwith 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete.
M&L in replacement of earthing with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel including concrete chamber with PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish internal surface of concrete chamberwith 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete.
Supply and fixing for ACB 1000 A, 4 Pole, LT 415 V, 65 KA breaking capacity with Electrical draw out, Micro processor release (IPR2 05 Pole) fixed type with auxiliary switch 6NO+6NC, Main CTs, safety shutters, 36 way auxiliary isolating contacts and horizontal terminal type complete including disconnecting and taking down the existing unserviceable ACB any type and making necessary electrical connections including making necessary fixing arrangements in the existing panel complete all as specified and directed by Engr-in-Charge.
Supply and fixing for ACB 800 A, 4 Pole, LT 415 V, 65 KA breaking capacity with Electrical draw out, Micro processor release (IPR2 05 Pole) fixed type with auxiliary switch 6NO+6NC, Main CTs, safety shutters, 36 way auxiliary isolating contacts and horizontal terminal type complete including disconnecting and taking down the existing unserviceable ACB any type and making necessary electrical connections including making necessary fixing arrangements in the existing panel complete all as specified and directed by Engr-in-Charge.
M&L in repair hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified.
M&L in repair framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing and similar work conforming to Fe-290 Gde E-165 complete all as specified.
Supply only chain link mild steel galvanisd fencing, any size or type medium coated as per IS 4826 of 40mm x 40mm mesh & 2 mm dia of wire complete all as specified.
Fixing only in repair chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provn of binding wire complete all as specified.
S&F in repair 3.15 mm dia plain mild steel wire, galvanised class 3, in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) complete all as specified.
M&L in repair 5 to 10 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long all as specified.
M&L for preparation of newly steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation of poles/struts with necessary form work complete.
M&L for cement concrete 1:3:6,type C-2 using 40 mm graded stone aggregate for foundation of pole/ stay assembly including frame work with necessary form work complete.
M&L for cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in padestal/coping of poles finished even and fair with necessary form work complete.
M&L for welding hinges to existing panel board with existing shutters and fixing to panel board complete all as specified.
M&L for replacement of shutter of panel with 3 mm thick CRCA sheet as per exisitng size to match with the existing panel and welding hinges and fixing complete all as specified.
M&L for painting of existing LT panel board with spray gun with synthetic enamel paint to match with the existing colour/surface complete.
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in pole coping including demolition of damaged coping complete all as specified.
M&L for preparation of old painted chain link/barbed wire fencing/gate/angle iron/post of sub station (outer exposed surface) and GI bracket/clamps with bolts, nuts and applying two coats of aluminium paint including writing substation details with black colur of existing size letters all as specified and as directed.
M&L for cutting existing road / foot path of bituminous macadam /PCC on foot path for laying protection pipe for cable and making good the disturbed surfaces in cement concrete 1:2:4 type B-1 all as required and directed by Engr-in-charge.
M&L for spreading stone agregate 40mm size for transformer yard/ HT 2 poe/4 pole stucture after preparing the surrounding by brick work and removing the vegetation and making brick work in CM 1:4 and necessary surface excevation and spreading of layer of sand all as specified and as directed. (Note:- (a) Earth work; brick work, sand etc shall be measured and paid seperately (b) Stack measurement shall be taken of stone aggregate before spreading)
Repairs to the existing earthing complete by replacing the unserviceable GI strip, bolt, nut, check nut and washer, earthing test point all as specified including testing on completion including making PCC chambers, RCC cover, GI funnel for watering, GI funnel, earth strip protection pipe including 10 kgs of salt and watering, testing of earth result by megger and submitting the report etc all as specified and as directed including writting and painting of earthing details (Note: The rate for excevation and all materials is inclussive in the quoted rate of item except Earth strip and protection pipe will be measured and paid seperately )
S&F in repair GI strip 32 x 6 mm as in earth continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc as required and all as directed.
S&F in repair GI strip 25 x 4 mm as in earth continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc as required and all as directed.
S&F in repair GI strip 25 x 3 mm as in earth continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc as required and all as directed.
S&F in replacement of RYB indicator LED type capacity complete campus complete all as specified. Make: HPL/ Indoasian/ L&T
M&L in replacement of PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 16 Sq mm 2 core complete all as specified.
M&L in replacement of PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 10 Sq mm 2 core complete all as specified.
S&F in replacement of Euro load change over switch with advance neutral of capacity 200 Amps , 415 Volts complete Make : Havells / HPL/ Indoasian
S&F in replacement of Euro load change over switch with advance neutral of capacity 400 Amps , 415 Volts complete Make : Havells / HPL/ Indoasian
Supply only in repair digital type voltmeter 0 to 500 volts suitable to operate with 415 volts AC 50Hz all as directed.
Supply only in repair digital type ammeter with suitable ratio to operate with CTs all as directed.
S&F in replacement of 2.5 mm thick insulated synthetic mat conforming to IS 15652 : 2006 and meeting the requirements of IS : 5216 (Part 1.2 & 3), IS 8437, IFC-479 Pub-1, alongwith suitable adhesive/chemical bound, PU resin, waterproofing compound and sealing material as per in service recommendation of IS : 15652 Class-B suitable for working voltage up to 11 KV with trolley movement complete all as specified and as directed by Engineer-in-charge.
Commercial Traders
DHARAMRAJ BUILDERS & ENGINEERS
DHAIRYAE ENTERPRISES
M/S Anand Enterprises
KISHORE ENTERPRISES
H.B. Traders
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .