Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance NO 33 NEHRU NAGAR FIRST FLOOR 3RD CROSS THENGAITHITTU ROAD PUDUCHERRY 600108 | 600108 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹40.0 L
EMD Value
₹79,990
Closing Date
21 Nov 2023, 3:00 pmClosed
THE DIRECTOR, CSIR-CECRI,KARAIKUDI
CSIR-CECRI, KARAIKUDI
Renovation of Electrical installation in Western colony staff quarters (Type II-14 Nos and III-10 Nos) at CSIR-CECRI, Karaikudi.
2023_CSIR_173943_1
CSIR CECRI NIT No 17/2023
Open Tender
Electrical Works
Item Rate
120 days
KARAIKUDI
PLEASE REFER NIT
8 documents required · 8 mandatory
₹0
₹79,990
24 Nov 2023
9 Nov 2023
24 Nov 2023
9 Nov 2023
21 Nov 2023
9 Nov 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2 x 2.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
100 mm X 100 mm X 60 mm deep
200 mm X 150 mm X 60 mm deep
250 mm X 300 mm X 60 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and fixing of 32 mm dia X 2.00 metres long GI. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as reauired.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Providing stay wire (Green colour sleeved one) with good quality PVC single phase reels (2 nos/Mtr) housing the existing single phase/ Three Phase submain wiring with Bi-Metallic Clamp for fixing the 7/18VIR wire as required and connecting them at both ends of quarters ie. At metering board and existing TNEB LT post including remiting the necessary charges for Service wire replacement to TNEB and co ordinating with TNEB persons for charging the LT supply satisfactorily and removing the existing stay wire along with the submain wires and handing over the same to department as per Engineer-in -Cahrges instruction as required.
Cast Iron Body Earthing : Providing cast iron pipe earth pit with 2000mm long 100mm dia 7mm thick cast iron pipe including excavation, refilling with salt, charcoal, natural soil and providing masonry cover etc.,complete in all aspects as required.
Removing the existing old type DB's, mainswitch's, fusecarriers, fans, lighting fixtures,GI sercice pipe, all type of wirings, switchboards etc, in each Staff quarters complete in all aspects as required and shifting the same to the department's stores or other places within the institution as per the instruction of the Engineer-in -charge.
Supply of 4 Ft Tube light fitting with Electronic choke and 40W lamp , similar to "Philips TMC 0901x TLD36/TL40W -4 Ft series having resistent to high voltage and high power factor etc as required. Make :Philips or equivalent as approved by the department)
Supply and Fixing of 45 Watts LED/4500 Lumens street light fittings similar to Philips (BRP052series)Smart Brite luminaire having high efficient lighting including making necessary interconnections from the point to the fittings while installing the same etc as required.
" TNEB Metering Board Single Phase Service line : a) Supplying and fixing of suitable size of teakwood plank for fixing of existing meter and other accessories as required. b) Supplying and fixing of 3 nos of 32A porcelin fuse unit. c) Supplying and Fixing of copper earth strip of size 19mm X 3mm thick of 6`` length for earth connections as reqd. d) Supplying and fixing of suitable GI pipe Minimum of ( 1" X 4 Mtrs length size) for receiving the service wires ( 2runs or 3 Runs of 7/18 VIR copper) at site and provision to insert the pipe inside the Metering set as req.The above complete set have to be mounted on wall. The charge including all interconntions and masonry works etc. e) Supplying and fixing FP sheet steel enclosure on board along with 25/32amps 240 volts ""C"" curve DP/SPN MCB complete with connections, testing and commissioning etc. as required. f) Refixing or shifting of Existing Meters with new boards including remitting of necessary charges to TNEB for meter shifting on behalf of CSIR-CECRI and co-ordinating with TNEB officials in all aspects in order to charge the metering panel board complete as required."
Tneb service line: Supplying of 6 sq. mm(7/18) VIR PVC insulated copper conductor, single core cable for TNEB Pole to Existing Meters as required.
Thirumalai Enterprises
POWER TECH ENTEPRISES
Sastha Electrical
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .