Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.9 CrAdmitted-Finance H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | L1 | Admitted-Finance | ||
| 2 | L2₹10.0 Cr−₹1.9 Cr (15.9%)Admitted-Finance 14 CHAHAR CONSTRUCTION CO ADARSH NAGAR NEAR ROHILLA COMMUNICAION 124103 | JHAJJAR | HARYANA | 124103 | L2 | Admitted-Finance | ||
| 3 | L3₹10.3 Cr−₹1.5 Cr (12.8%)Admitted-Finance HOUSE NO 953 SECTOR 23 HUDA BHIWANI 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | L3 | Admitted-Finance | ||
| 4 | Rejected-Technical 28 29 GALI NO 05 MAHABIR PARK 124507 | BAHADURGARH | JHAJJAR | HARYANA | 124507 | - | Rejected-Technical Non responsive as per Clause 4.7 of the CBD |
Tender Value
₹14.1 Cr
EMD Value
₹28.2 L
Closing Date
8 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AMAN Mor
Bahadurgarh PHED
Mandothi, Const. of 1No. STP of 2.5 MLD based on SBR at, MPS consisting of RCC Coll. tank, Screening Chamber of suitable size for 2.5 MLD Capacity, B.Wall 320M, Devp. of STP Site, road, Staff Qtr. of 40.88Sqm, Const. of HT,LT Panel room, PLC room, Ce
2025_HRY_483862_1
2025B89E0CE9 70D6 4BC2 9B2F 11D2C948371B593PUH
Open Tender
Civil Works
Works
730 days
MANDOTHI
Eligibility Criteria as per approved DNIT
3 documents required · 3 mandatory
₹20,000
₹28.2 L
Yes
4 May 2026
17 Nov 2025
8 Dec 2025
17 Nov 2025
8 Dec 2025
17 Nov 2025
HSR Itmes
BoQ_Ver3.0
NAME OF ESTIMATE:- MANDOTHI:- CONSTRUCTION OF 1 NO. STP, 2 NOS. IPS and PROVIDING SEWERAGE SYSTGEM IN VILLAGE MANDOTHI DISTT. JHAJJAR (UNDER SWARAN JAYANTI MAHAGRAM YOJNA) Name of DNIT:- Mandothi: Const. of 1No. STP of 2.5 MLD based on SBR at, MPS consisting of RCC Coll. tank, Screening Chamber of suitable size for 2.5 MLD Capacity, B/Wall 320M, Devp. of STP Site, road, Staff Qtr. of 40.88Sqm, Const. of HT/LT Panel room, PLC room, Centrifuge house, blower room and Lab-cum-office building, P/Machinery, CCTV camera at STP/MPS, lighting, 300mm i/d RCC pipe for effluent from STP to Drain, P/Machinery, 1 No. P.C of 3.66x3.05M, RCC collecting tank of size of 3.50x2.50x1.83M., B/wall 60M, road, 200mm i/d D.I Pipe, lighting, Screening chamber at IPS No.1, P/Machinery, Const. of RCC collecting tank of size 3.25x2.25x1.83M, 1 No. PC of 3.66x3.05M., B/wall 60M, road, 200mm i/d D.I. Pipe,lighting,Screening chamber at IPS No.2, Laying of Sew. Network of 200 to 500mm i/d, Const. of Manhole of various sizes, Intercepting chamber of various sizes, restoration of damaged water connections OandM for 6 years including 1 year defect liability period and all other works contingent thereto” -[DNIT No.-138767]
Contact No: 01276-242976
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
MS Grating Cover of 450 x 450 mm size
Construction of HT/LT Panel room, PLC room, Centrifuge house, blower room and lab cum office building including doors, windows and fitting etc. at STP site covered area with RCC framed structures of brick work vitrified glzed tiles flooring, powder coated aluminium frame of size 100 x 45mm of 10 guage for door frame, 45mm x 45mm of 10 guage for window frame with 5mm thick glass AIS/Saint Gobin/Modi Float...
Providing and installation of 6 No. CCTV cameras (2 at MPS and 4 at STP ) including cost of Wiring DVR, cable, lens etc. complete in all respects....
MAIN PUMPING STATIONS:- Design, construction, erection, testing and commissioning of MPS and following components. i) Panel room of 30 sqm. covered area, Pump Chamber of 8.53 x 3.96 Mtrs., HT Metering Panel Room of 4.50 x 3.66 Mtrs and PLC room including toilet block of 20 Sqmtr. covered area with RCC framed structure of brick work vitrified glazed tiles flooring, Powder coated aluminium frame of size 100mm x 45mm of 10 gauge for chowkhat, 75mm x 45mm of 10 gauge for door frame, 45mm x 45mm of 10 gauge for window frame, 5mm thick glass AIS/Saint Gobin / Modi Float, The toilet block shall be with one half staff urinal and One European W/C, one wash hand basin as per approved drawings. ii) RCC Inlet chamber, Screen Chamber, rectangular collecting tank suitable for 2.50 MLD average flow with peak factor of 3.00, land scaping of the campus complete in all respect. Providing and installing 1 No motor of 3DWF,2 Nos. of 1DWF and 2 Nos. 0.50 DWF with 15 Mtr Head each with suitable LT Panel equipped with all safety devices, automative capacitor bank and submersible cable from LT panel to pump set complete in all respect. iii) K9 DI pipe of suitable Dia at MPS Including welding and screwing of flanges, ISI marked D.I. fittings, Sluice valve, non return valves as per requirements even for bye-pass arrangements complete in all respect. iv) 3 nos. CI Gear Operated Sluice Gate with SS Spindle (SS 410) and seats (SS 304) (2 nos. for screen and 1 no. for partition of collecting tank) as per design. v) Supply and installation of 2 nos. mechanical course screens of minimum length 6 mtrs. for 2.50 MLD average flow with peak factor of 3.0. 1. The connecting sewer of same diameter and material of construction, laid at adequate depth between existing sewers to newly constructed structures is included in scope of work. 2. All the infrastructure except construction of Staff quarter ,Boundary wall (except Main Gate) and path ways/ roads required to be executed at site to make the MPS functional is included in the scope of work for lump-sump job. 3. All the pumping machinery, panel board, Level sensor etc. shall be controlled by PLC and SCADA and shall be synchronized with PLC panels at MPS and STP site through broadband internet facility. 4. The size and quantities of all the above components will be as per approved structural /Hydraulic /Mechanical /Electric design to be approved by Department before actual execution of work.
SEWAGE TREATMENT PLANT :- Design, construction, erection, testing and commissioning of 2.50 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including Landscaping MCC Panel room and all other contingent Electrical, Mechanical, Electromagnetic Flow Measurement Device, Real Time Water Quality Monitoring with Data Collection System (Online analyzer), Piping and Instrumentation works with PLC and SCADA Arrangement for STP and MPS along with Synchronizing it with each other including furniture and laboratory equipments as per detail given in the bid document and including following components . i) 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED energy outdoor suitable size reputed make efficient lamps on each pole, including 20 no. LED outdoor lights with GI poles 7 mtr high including all accessories along the road and path complete in all respect. ii) Supply and installation of 1 No. Main Gate of (SS) 12 ft. wide main gate and 4 ft. wide wicket gate (total weight not less than 500 kg) at STP site. as per satisfaction of Engineer-incharge. iii) Providing and installing 2 No. centrifuges (1 Working plus 1 Stand bye) including centrifuge feed pump, all fittings, instrumentations, electric panel board etc. as per design complete in all respect of the NIT, including packing dry sludge in 20Kg Bag and supplying the same Market Kisan Sewa Kendra or as directed by Engineer-in-charge within lead as pointed at clause 4.4.5 of NIT. iv) Providing and installation of 2 nos. pumping sets of suitable size (1 working and 1 standby) with head 15 mtrs. in chlorination tank to disposed off the treated effluent including all fittings, instrumentations, electric panel board etc. as per design complete in all respect v) Supply, Installation, Testing, Commissioning, operation and Comprehensive Annual Maintenance of effluent quality monitoring system at 2.50 MLD STP at Village for Online (Continuous) measuring of PH, total Suspended Solids (TSS) Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cable, local data acquisition and display the data of continuous basis for up linking the data of CPCB, HSPCB and PHED, TUV Board approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents and as contained in scope of work in the notice inviting tender: Multi-parameter measuring converter, for connecting up to 18 intelligent seniors Scope including 8 analog inputs/Outputs(4 Inputs and 4 outputs) (o/4- 20Ma), wide range power supply optical COD/BOD and TSS probe with spectral processing of the UV-VIS range for measurement plant of 3.00 MLDSTP at with integrated with automatic cleaning. Robust digital pH/ORP sensor for pH/ORP electrodes, with built-in pre-amplifier and temperature sensor with Automatic Temperature Compensation (ATC) Cable length 100 Meter (minimum).Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to intelligent sensors net system cable length 100 Meter (Minimum) Data Transfer to CPCB, HSPCB and PHED Servers. Providing GSM 3G, 4G Modem with mobile network connectivity including network charges.
Operation and Maintenance of Sewerage Network, STP ,MPS, IPS complete scope of work mentioned in the DNIT Disinfection material supplied by the PHED as per schedule-IV for a period of 5 years after 12 months during defect liability period and 3 months trial run period. (will be charged to the A/mtc estimate). complete in all respects as per approved NIT. 1) Operation and maintenance during defect liability period after 3 month trial run period ( operation only)
1st year Operation and maintenance after defect liability period
2nd year Operation and maintenance
3rd year Operation and maintenance
4th year Operation and maintenance
5th year Operation and maintenance
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_561874.xls
BOQ • 0.34 MB
778775Z138767.pdf
Additional Documents • 5.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .