Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹46.5 L+₹3.2 L (7.34%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹64.5 L+₹21.2 L (49.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹64.7 L+₹21.4 L (49.5%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹67.9 L+₹24.7 L (56.9%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹58.2 L
EMD Value
₹1.1 L
Closing Date
3 Sept 2024, 6:00 pmClosed
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
SPECIAL REPAIR/REPLACEMENT OF HT LINES, GOD, HT POLES, DEFECTIVE LT CABLES, LT PANELS AND ALLIED WORKS AT SECTOR C AND D UNDER GE 865 EWS LEH
2024_MES_660550_1
138WE/L-35/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹1.1 L
Yes
7 Oct 2024
19 Jun 2024
10 Sept 2024
19 Jun 2024
3 Sept 2024
10 Jul 2024
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 3.0 m in depth and getting it out for pole erection in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed.
M&L for Sand cushioning to UG cable, provide with the layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable complete all as specified and directed. NOTE : Punned down thickness shall be measured.
Supplying and laying unreinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x180mm x 40mm placed perpendicular to the cable complete all as specified and directed.
Supply and fixing GI Pipe Light grade with all connected accessories of size 100 mm bore dia complete all as specified and directed.
Cutting of existing road not exc 1.5 m in depth and not exceeding 1.5 m wide including black top, sub base and WBM, well ramming in layers with watering after laying of RCC /GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge.
Supplying laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 95 Sq mm complete all as specified and directed.
S&F in repairs cable end joint boxes 95 Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor type, complete all as specified and directed.
S&F in repairs cable straight through joint 95 Sqmm, 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work complete all as specified and directed.
Supply and fixing in replacement of gang operated air break switches HT 11KV grade outdoor type, triple pole of capacity 200 amps rating mounted on polymer based 09 insulators fitted on steel frame horizontally, mechanically operated mechanism from ground level including GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangements complete all as specified and directed.
Supply, fixing and connecting HT 11 KV outdoor expulsion type lightning arrestors with mounting accessories complete fixed on cross arms of 2 pole structur and connected with same size of ACSR conductor as O/H HT conductor with 11 KV KT empire tape insulation with all fittings, transmission class, having discharged capacity of 65 kilo amps and suitable for working pressure of HT 11 KV complete all as specified and directed.
S&F in repair disc insulator porcelain vitreous brown 145mm high and 255mm dia ball and socket type single disc assembly for tension with tension clampstor conductors working pressure 11000 volts complete all as specified and directed.
S&F in repair pin/post type polymer based insulator 150mm height and 150mm dia suitable for 11 KV grade insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut,complete all as specified and directed.
M&L for stay assembly complete with 30x30x6mm thick plate and 20mm dia stay rod and stay insulators all as shown in electrical plate No. 1 including necessary excavation, earthwork stay bow, stay wire and PCC complete all as specified and directed.
Supply & erecting in position steel tubular swaged poles complete with cast iron base plate, final taper plug bolts, nuts and screws as specified type 410 SP-55 (11.0 meters long) complete all as specified and directed by Engr-in-Charge
M&L for cement concrete 1:4:8 type D-2 in foundation filing and mass concrete using 40 mm graded crushed stone aggregate for pole/stay foundation etc complete all as specified and directed by Engr-in-Charge
M&L for cement concrete 1:3:6 type C-2 in foundation filling and mass concrete using 40 mm graded crushed stone aggregate for pole/stay foundation etc complete all as specified and directed by Engr-in-Charge
Materials and labour in replacement for mild steel work in cross arms, bracings supports clamps and back plates fabricated from structural steel section including nuts bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of two quotes of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for fixing in replacement of ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etc complete all as specified.
M&L in replacement for Galvanised steel wire 3.15 or 4.00 dia complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in groungd vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, checknuts and washers etc made of GI and connected earthing test points all as shown in electrical plate no. 5 of SSR Part-1 of 2009 and as specified or indicated and testing on completion including exaction/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm) funnel with grade and lugs, including galvanised iron strip 32 X 6 m with GI protection pipe of 40 mm medium grade 7.5 meter long,etc complete all as specified and directed.
M&L for HT jumper with the help of Aluminium Conductor Steel Re-inforcement covered with insulating material/sleeve and including lugs at both ends at suitable at site. The length of jumper shall not be less that 2.5 meter including connection with the help of connector on the HT pole complete all as specified and directed.
Disconnecting the transformer any type situated at various locations 11/ 0.433 KV of any make and transporting to new location including installation, connection and ,testing complete all as directed. Note : Transportation cost is deemed to be included in the quoted rate.
S&F in replacement of ON Load change over switch (front handle) 415 volt in sheet metal enclosure, 4 pole, 1000 Amps capacity complete all as directed by Engr-in-charge.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 500 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified. (Earth work, cable protection and sand cushioning shall be measured and paid for seperately)
All as per srl item No. 27 here in before but of size 240 Sqmm 3.5 core all as specified .
All as per srl item No. 27 here in before but of size 185 Sqmm 3.5 core all as specified .
All as per srl item No. 27 here in before but of size 150 Sqmm 3.5 core all as specified .
All as per srl item No. 27 here in before but of size 120 Sqmm 3.5 core all as specified .
All as per srl item No. 27 here in before but of size 95 Sqmm 3.5 core all as specified .
All as per srl item No. 27 here in before but of size 70 Sqmm 3.5 core all as specified .
All as per srl item No. 27 here in before but of size 50 Sqmm 3.5 core all as specified .
All as per srl item No. 27 here in before but of size 35 sqmm, 3.5 core all as specified .
All as per srl item No. 27 here in before but of size 25 sqmm, 3.5 core all as specified .
All as per srl item No. 27 here in before but of size 16 Sqmm, 2 core all as specified .
All as per srl item No. 27 here in before but of size 10 Sqmm, 2 core all as specified .
Material and labour for preparation of size 3 mtr x 3 mtr x1.5 mtr Platform for installation of 500 KVA Transformer with base of PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) including chain link fencing around the platform of min weight 4 kg/Sqm and entrance gate as per deisgn approved by GE complete all as directed.
Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-2 flate size 250 mm x 150 mm x 40mm , complete all as specified and directed
Supply & fixing in replacement of tubes light grade of size 50 mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified.
Supply & Installation ,testing and Commissioning in replacement of LT Panel cubical type out door floor mounted weather proof totally enclosed, (CPRI approved) factory made and made out of 3 mm thick CRCA powder coated sheet and angle iron complete with bus bar of Aluminium of suitable size for capacity 1000 Amps 3 Phase and Neutral 415 Volts 50 Hz mounted on epoxy type insulators with PCC flooring and angle iron base frame complete all as directed by the Engr-in-charge including fallowing accessories:- a) MCCB 630 Amps Cap 4 Pole 50 KA 415 -1 No for( I/C) b) MCCB 200 Amp cap 4 pole 36 KA 415 Volts - 2 Nos c) MCCB 160 Amp cap 4 pole 36 KA 415 Volts - 3 Nos d) Digital Volt meter with sellector switch(0-500V) - 02 Set e) Digital Amp meter with sellector switch with necessary CT (0-500A) - 02 Set f) LED indicating lamp - 02 Set Note : (i) The rates deemed to be inclusive of suitable size copper wirinng/copper strips from Main I/C MCCBs to Channge over switch, Change over switch to Main Bus bar and Bus Bar to Outgoing MCCBs complete all as specified and directed. (ii) The design of Panel, Make of complete accessories and drawing of the LT Panel should be submitted by the contractor for pre-approval from the GE before placing order and execution at site.
Supply & Installation ,testing and Commissioning in replacement of LT Panel cubical type out door floor mounted weather proof totally enclosed, (CPRI approved) factory made and made out of 3 mm thick CRCA powder coated sheet and angle iron complete with bus bar of Aluminium of suitable size for capacity 600 Amps 3 Phase and Neutral 415 Volts 50 Hz mounted on epoxy type insulators with PCC flooring and angle iron base frame complete all as directed by the Engr-in-charge including fallowing accessories:- a) MCCB 400 Amps Cap 4 Pole 25 KA 415 -1 No for( I/C) b) MCCB 160 Amp cap 4pole 16 KA 415 Volts - 1 Nos c) MCCB 125 Amp cap 4 pole 16 KA 415 Volts - 2 Nos d) Digital Volt meter with sellector switch(0-500V) - 02 Set e) Digital Amp meter with sellector switch with necessary CT (0-500A) - 02 Set f) LED indicating lamp - 02 Set Note : (i) The rates deemed to be inclusive of suitable size copper wirinng/copper strips from Main I/C MCCBs to Channge over switch, Change over switch to Main Bus bar and Bus Bar to Outgoing MCCBs complete all as specified and directed. (ii) The design of Panel, Make of complete accessories and drawing of the LT Panel should be submitted by the contractor for pre-approval from the GE before placing order and execution at site.
Supply, Fixing, connecting and testing and Commissioning of Factory made out door Street light Panel cubical type Pole / floor mounted totally enclosed made out of 2.16 mm thick CRCA powder coated sheet and angle iron base frame of height 2' occompanied with 65 Amp contactor ,TPN MCB 63 Amp, Max capacity12 KW, with digital type timmer switch internaly pre wired suitable for 3 Ph power supply complete all as specified and directed.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 630 Amps, 50 KA, 415 Volts four pole complete all as specified and as directed.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 400 Amps, 36 KA, 415 Volts four pole complete all as specified and directed.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 250 Amps, 36 KA, 415 Volts four pole complete all as specified and directed.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 200 Amps, 36 KA, 415 Volts three pole complete all as specified and directed.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 160 Amps, 25 KA, 415 Volts three pole complete all as specified and directed.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 125 Amps, 25 KA, 415 Volts three pole complete all as specified and directed.
Supply and errect steel tublar swaged poles complete with MS sheet welded on base , finial taper plug, bolts, nuts and screws as specified type 410 SP -31 (9 meters long) including painting with two coats of synthetic enamel paint complete all as specified and directed.
M&L for Cement concrete in filling and mass concrete/Coping of Poles and PCC for road crossings etc all as directed , type C-1 1:3:6 (20 mm graded crushed stone aggregate) complete all as specified and directed.
M&L for fixing in replacement of shackle insulator porcelain white, brown or green 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and as directed.
M&L for fixing in replacement of pin insulator porcelain white, brown or green 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and as directed.
M/S SHEYSHAN ENTERPRISES (BID ID -3058383)
darshan kumar gandhi (BID ID -3073396)
EESSI (BID ID -3062079)
SUMEET TRADING CORPORATION (BID ID -3065318)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .