Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.1 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹25.9 L+₹2.5 L (10.6%)Rejected-Finance | L-2 | Rejected-Finance NOT BEING A LOWEST BIDDER | |
| 3 | L-3₹26.7 L+₹3.3 L (14.0%)Rejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L-3 | Rejected-Finance NOT BEING A LOWEST BIDDER | |
| 4 | L-4₹28.8 L+₹5.3 L (22.8%)Rejected-Finance R O RAWALPORA WANBAL YAIYAL TEH DISTT SRINAGAR J K PIN 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-4 | Rejected-Finance NOT BEING A LOWEST BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
27 Jul 2022, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 apo
REPAIR MAINTENANCE OF INTERNAL WIRING FITTING FIXTURES AND EXTERNAL ELECTRIC LT DISTRIBUTION SYSTEM AT KHREUH AND SHER E SHALI UNDER GE 861 EWS
2022_MES_533248_1
GE 861EWS-23/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹70,000
Yes
21 Sept 2022
23 Jun 2022
3 Aug 2022
23 Jun 2022
27 Jul 2022
8 Jul 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable maintaining colour coding (Phase- Red/yellow/Blue, Neutral- Black) and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-2 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-2 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No 2 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
Switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
Switch piano flush button types 16 Amp, single pole, one way complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 Amp flush type, universal, complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
Socket outlet, 3 pin, 6 Amps flush type, complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type, complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required at site or directed.
Bell push, flush type, 5 Amp, complete all as specified and directed.
Bell, AC, 240 Volts, single pole, complete all as specified and directed.
Supply and fix in repair 9 watt LED light fitting mirror type with high out put diffuser, 220 V AC decorative type with inbuilt electronic driver complete with all accessories prewired and connecting electrically to ceiling rose using PVC FRLS insulated and overall sheated flexible copper conductor cable of suitable size complete, complete all as specified and directed. Make Havells Cat Part No LIMILINEBS9WLED830SPCWH or equivalent in Crompton Greaves/ GE/Philips/Bajaj.
Supply and fix in repair wall mounted LED Batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver of Lamp type: 18W LED life time of 30000* hours including lamp and connecting electrically to ceiling rose using PVC FRLS insulated and overall sheated flexible copper conductor cable of suitable size, complete all as specified and as directed. Make Havells Cat Part No LIMILINEBS18WLED830SPCWH or equivalent in Crompton Greaves/ GE/Philips/Bajaj.
Supply and fix in repair LED luminaire new generation recessed mounted ultra slim panel 2x2 feet 28 watt 220 volts AC, CRCA powder coated body and high translucent diffuser provides high quality economic energy saving lighting to modern offices suitable for 600x600mm modular/POP/gypsum ceiling complete with drivers, holders, LED lamp including connecting electrically to ceiling rose using PVC FRLS insulated and overall sheated flexible copper conductor cable of suitable size, complete all as specified and directed. Make Havells Cat Part No PLAN02X2PLR28WLED857S or equivalent in Crompton Greaves/ GE/Philips/Bajaj.
Supply and fix in repair LED luminaire new generation surface mounted ultra slim panel 2x2 feet 28 watt 220 volts AC, CRCA powder coated body and high translucent diffuser provides high quality economic energy saving lighting to modern offices suitable for 600x600mm modular/POP/gypsum ceiling complete with drivers, holders, LED lamp including connecting electrically to ceiling rose using PVC FRLS insulated and overall sheated flexible copper conductor cable of suitable size, complete all as specified and directed. Make Havells Cat Part No PLAN0SURFACE2X2PLR28WLED857S or equivalent in Crompton Greaves/ GE/Philips/Bajaj.
LED light fitting 6W-10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking out old, complete all as specified and directed. Make Havells Cat Part No RUGBYNEONFT10WLED760SSYMBOPC or Philips Cat Part No WT202WLED6SNWPSUS2PC equivalent in Crompton Greaves/ GE/Bajaj.
Supply and fixing in repair LED 7 watt pin type bulb, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 12 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in replacement of MCB distribution board TPN, vertical type 4 way, 240V wirh 200 Amps rated copper busbar with neutral links double door sheet steel enclosure powder coated, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB single pole 240 volts 6 to 32 amps as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed.
MCB single pole and neutral 240 volts 6 to 32 amps 'C' Curve as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed.
Supply & fixing in replacement of for MCB single pole neutral 240 volts 40 to 63 amps as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification, complete all as specified and directed.
Supply & fixing in replacement of MCB TPN 415 volts, 40 Amps 'C' Curve 10 kA capacity, complete all as specified and directed.
MCCB four pole , 415 Volt, 63 Amps, 10 KA , adjustable thermal & fixed magnetic setting complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 4.0 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4.0 sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked incl taking down old unsv, complete all as required at site or directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 6.0 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6.0 sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked incl taking down old unsv, complete all as required at site or directed.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 1.50 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted, complete all as specified & directed.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 2.50 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted, complete all as specified & directed.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 4.0 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted, complete all as specified & directed.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 6.0 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted, complete all as specified & directed.
Supplying and fixing 1100volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core 10 sqmm cable flat or circular, complete all as specified and directed.
Supplying and fixing 1100volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core 16 sqmm cable flat or circular, complete all as specified and directed.
Supply and fixing in repair, Plug top 3 pin 5/6 amps 230 volts, complete all as specified and directed.
Supply and fixing in repair Plug top 3 pin 15/16 amps 230 volts, complete all as specified and directed.
Supply & fixing in repair PVC Gang box surface type suitable for fixing of 5 pin 5 Amp multipurpose switch socket on wall complete all as specified and directed.
Supply & fixing in repair PVC Gang box surface type suitable for fixing of 5 pin 15 Amp multipurpose switch socket on wall complete all as specified and directed.
Supply & fix in repair Rigid non-metallic grade PVC conduit of size 20 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed.
Supply & fix in repair Rigid non-metallic grade PVC conduit of size 25 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed.
Supply & fix in repair medium grade PVC casing and capping of size 20 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed.
Painting of ceiling fans complete of any size and make, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc., complete all as specified and directed.
Replacement of capacitor 2.5/3.15 mfd AC 230 volts 50 Hz complete all as specified and directed.
Replacement of capacitor 4 mfd AC 230 volts 50 Hz complete all as specified and directed.
Replacement of ball bearing suitable for ceiling fan/exhaust fan any size and any make, complete all as specified and directed.
Replacement of gun metal bush with suitable size for ceiling fan any make, any size and sweep, complete all as specified and directed.
Rewinding of AC ceiling fan/wall mounted fan motor as existing at site any make with super enameled copper winding wire any gauge from 0.315mm to 0.193mm including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, connection with flexible wire of appropriate size two core copper wire up to connector block qty of copper winding wire not less than 350 grams and not more than 500 grams per fan motor, complete all as specified and directed.
Rewinding of exhaust fan motor any size, from 225 to 400 mm sweep with supper enameled copper wire of any size ranging from 0.500mm to 0.285 mm including necessary cutting of old burnt winding wire, cleaning of slots and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size up to connector block, complete all as specified and directed.
Taking down carefully geyser 25/35/50 liters capacity from wall after unscrewing nuts/bolts etc. and again refixing in position after necessary repair and replacement of spare parts including testing etc complete all as specified and directed. NOTE: Spare parts shall be measured and paid for separately under respective items.
Replacement of heating element AC 230 Volt of rating 1500W (circular/triangular) ISI mark as per existing any type, complete all as specified and directed.
Replacement of heating element AC 230 Volt of rating 2000W (circular/triangular) ISI mark as per existing any type, complete all as specified and directed.
Replacement of thermostat switch AC 230 Volt adjustable range from 0-90 degree Celsius, complete all as specified and directed.
Replacement of indicator lamp round/square in shape suitable for 25-50 ltr storage type water heater as per sample 230 volt, complete all as specified and directed.
Replacement of auto-cut switch suitable for geyser 25-50 ltrs 230 volts AC all as per sample, complete all as specified and directed.
Replacement of geyser assembly suitable for geyser 25-50 ltrs 230 volts AC all as per sample, complete all as specified and directed.
Replacement flexible PVC connection pipe heavy duty suitable for hot water to bear the temperature 100 degree Celsius with out let and inlet connection brass adaptor and PVC washer having size 450 mm long 15 mm nominal dia complete all as specified and directed.
Dismantling existing UNSV hylam sheet of any size from boards removing switches etc. Supply and fix hylam sheet 3mm thick including necessary cutting of suitable opening for switches, sockets, regulators, etc refixing of switches, sockets, regulators, etc replacing screws and connecting up and testing, complete all as specified and as directed.
Replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps/32 Amps, 240 volts, complete all as specified and directed.
Replacement of sunken cast iron/pressed steel terminal boxes 60mm deep 6'x8' for mounting switch/socket on hylum sheet, complete all as specified and directed.
Replacement of sunken cast iron/pressed steel terminal boxes 60mm deep 8'x10' for mounting switch/socket on hylum sheet, complete all as specified and directed.
Replacement of sunken cast iron/pressed steel terminal boxes 60mm deep 10'x12' for mounting switch/socket on hylum sheet, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6mm as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long copper strip of size 32x6mm with protection pipe of 40mm dia GI light grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by -24.0%(Minus) (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed.
Excavation in trenches beyond 1.5 m wide and n.exc. 3 m deep for foundation of poles/stay etc including getting out in any type of soil complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified.
Supply and fixing steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-31 ( 9 Mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified laying GI pipe light grade for cable protection and fixing to existing pole with flat iron clamp 25x3mm including nuts bolts and washers etc complete of 40mm dia including taking out old unserviceable pole, complete all as specified and directed.
Pin type insulator porcelain, vitreous, white/ brown or green insulators including one galvanized MS spindle, two galvanized iron washer, GI nut of size 100 mm height and 65mm dia 1100 volts grade including dismantling of old unsv, complete all as specified and directed.
Shackle type insulators, porcelain, vitreous white/ brown or green including galvanised MS strips, bolt, nuts and washer of size 75mm height and 90mm dia, size of strap section 31x3mm and dia of 12 mm for working pressure 1100 volts grade incl dismantling of old unsv complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as indicated or directed and inclusive of one primer coat, and one under coat and one finished coat of aluminium paint incl dismantling of old unsv complete all as specified and directed.
Aluminium conductors, reinforced (ACSR) conductor of any size for OH lines including stretching, binding wire ,jumpers, line taps etc including dismantling of old unsv complete all as specified and directed.
Restretching only the ACSR conductor fixed on over head line pole and tightening the ACSR, taking down the conductor from insulators complete with auth sag and rewinding with insulators in proper position after tightening with new aluminium winding wire of dia 2mm all as specified and directed.
Stay assembly using stay rod of 16mm dia complete with accessories as shown in electric plate No. 1 and including loop type insulator white brown or green incl dismantling of old unsv, complete all as specified and directed.
M&L in repairs MCCB 4 pole, 415 volts adjustable type, 63 Amps with breaking capacity 16 KA complete all as specified and directed.
M&L in repairs MCCB 4 pole, 415 volts adjustable type, 100 Amps with breaking capacity 25 KA complete all as specified and directed.
M&L in repairs MCCB 4 pole, 415 volts adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified as directed.
M&L in repairs MCCB 4 pole, 415 volts adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified as directed.
M&L in repairs MCCB 4 pole, 415 volts adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed.
M&L in repairs MCCB 4 pole, 415 volts adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed.
M&L in repairs change over switch on load 415 volts FP in sheet metal enclosure with side handle of capacity 63 Amps, complete all as specified and directed.
M&L in repairs change over switch on load 415 volts FP in sheet metal enclosure with side handle of capacity 100 Amps, complete all as specified and as directed.
M&L in repairs change over switch on load 415 volts FP in sheet metal enclosure with side handle of capacity 200 Amps, complete all as specified and directed.
M&L in repairs change over switch on load 415 volts FP in sheet metal enclosure with side handle of capacity 400 Amps, complete all as specified and directed.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 sqmm nominal cross section 4.0 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
Description all as per item No. 93 above but cross sectional area 25 Sqmm 4.0 core complete all as specified and directed.
Description all as per item No. 93 above but cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 923 above but cross sectional area 50 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 93 above but cross sectional area 95 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 93 above but cross sectional area 150 Sqmm 3.5 core complete all as specified and directed.
Taking out from trenches/poles/wall etc LT UG Cable PVC insulated sheathed with multistranded aluminium conductor armoured and relaying after fault rectification duly tested in trenches/Poles/Wall of LT UG Cable of any sizes including earth work complete all as specified and directed
Supply & fixing in replacement of cable end heat shrink type jointing kit 1100 Volts for indoor/outdoor termination with jointing material and accessories suitable for 16 Sqmm to 50 Sqmm 3.5/4 core XLPE/PVC armoured aluminium conductor cable complete all as specified and directed.
Supply & fixing in replacement of cable end heat shrink type jointing kit 1100 Volts for indoor/outdoor termination with jointing material and accessories suitable for 95 Sqmm to 120 Sqmm 3.5 core XLPE/PVC armoured aluminium conductor cable complete all as specified and directed.
Supply & fixing in replacement of cable end heat shrink type jointing kit 1100 Volts for indoor/outdoor termination with jointing material and accessories suitable for 150 Sqmm to 300 Sqmm 3.5 core XLPE/PVC armoured aluminium conductor cable complete all as specified and directed.
Painting of steel tubular electrical poles cross arms channels etc after scrapping the old patchy cracked painted applying one coat of aluminium paint to complete pole,clamps,channel ,cross arms and black strip of 30cm up to 1.5 mtr height on the same including preparation of surfaces complete all as specified and directed. Note: Contractor will ensure shut down on the feeder in writing before commencement of painting work on electrical poles.
Painting of PCC poles with bracket/fitting etc complete by scrubbing old deteriorted paint and preparing the surfaces and applying two coats of cement base paint including colour strip of two coats of synthetic enamel paint upto 1.50 mtr height, writing pole No. in black base, complete all as specified.
Trimming of trees branches from electric over head lines and clearing of 2 meter distance horizontal and vertical from outer edge of conductor including removing cut branches 50 Mtr (minimum) away from the place all as directed. Note: Contractor will ensure shut down on the feeder in writing before commencement of work on electrical lines.
Supply and laying in repairs 80mm dia GI tubing light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed.
Supply and laying in repairs 50mm dia GI tubing light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed.
Supply and laying in repairs 40mm dia GI tubing light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed.
Make bore to road/cement path/hard standing for GI pipe 40 to 80 light gradefor passing armoured cable including making good the disturbed surface as per site requirement, complete all as specified and directed.
Replacement of voltmeter 0-500 volts, digital type, complete all as specified and directed.
Replacement of ammeter 0-400 Amps, digital type, complete all as specified and directed.
Replacement of CTs for ampermeter, complete all as specified and directed.
S & F in repair bus bar chamber of size 60x60x45cm suitable for 3 phase 433 volts, outdoor type made out of 3.15mm thick MS sheet with 200 Amps rated aluminium bus bar(4 Nos) PVC sleeves and coloured (red, yellow, blue and black) with locking arrangements and angle iron stand of size 40x40x6mm frame grouted in ground with PCC foundation 1:2:4 type B-1 with 20mm graded stone aggregate alongwith all necessary cable connections, lugs and cable gland including 2 coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Supply & fix in replacement cable PVC insulated flexible copper conductor cable of size 1.5 Sqmm 3 core cut to pieces all as required, drawn into conduit/pipe fixed to wall or pole, complete all as specified and directed.
Taking down old unsv security light/street lights and S&F 30 Watt next generation LED street light fitting 230 V AC outdoor type with high pressure die-cast aluminum housing with prismatic polycarbonate diffuser with IP-66 ingress protection and IK-08 impact resistance, 4kV inbuilt surge protection with tp opening driver cover for easy maintenace including necessary connection suitable size copper conductor cable, complete all as specified and as directed. Make Bajaj Cat Part No ENXT P 30L WH PO PC SD or equivalent in Crompton Greaves/ GE/Philips/Havells.
Taking down old unsv flood lights and S&F 60 Watt energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting including necessary connection suitable size copper conductor cable, complete all as specified and as directed. Make Havells Cat Part No JETAALBAFLOODLIGHT60W or equivalent in Crompton Greaves/ GE/Philips/Bajaj.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated copper conductor (Solid ) of size 16 Sqmm single core served with inner sheathing of PVC tape and overall PVC sheathed in service connections, complete all as specified and directed.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated copper conductor (Solid ) of size 25 Sqmm single core served with inner sheathing of PVC tape and overall PVC sheathed in service connections, complete all as specified and directed.
Taking down old unsv and supply only aluminium thimbles 1100 volts suitable for 70 Sqmm to 150 Sqmm cable complete all as specified and directed.
Taking down old unsv and supply only aluminium thimbles 1100 volts suitable for 25 Sqmm to 50 Sqmm cable complete all as specified and directed.
Taking down old unsv and supply only aluminium thimbles 1100 volts suitable for 6 Sqmm to 16 Sqmm cable complete all as specified and directed.
Taking down old unsv and supply only smooth finish highly durable ruggedness copper thimbles 1100 volts suitable for 70 Sqmm to 150 Sqmm cable complete all as specified and directed.
Taking down old unsv and supply only smooth finish highly durable ruggedness copper thimbles 1100 volts suitable for 25 Sqmm to 50 Sqmm cable complete all as specified and directed.
Taking down old unsv and supply only smooth finish highly durable ruggedness copper thimbles 1100 volts suitable for 6 Sqmm to 16 Sqmm cable complete all as specified and directed
Javeed And Co
M/S LATIF AHMAD BABA CONSTRUCTION
M/S RATHER CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .