The Project Director, DRDA, Sivagangai
O/o The Project Director, DRDA, Sivagangai
Implementation of Jal Jeevan Mission to provide Functional Household Tap connection to Rural Households in Bramanakuruchi, Sathanur and Perumpacheri Village Panchayats in Ilayangudi Panchayat Union in Sivagangai District for the year 2020-21 (Package
2020_RDTN_172687_1
DIPR/2674/Tender/2020jjmPk5ily
Open Tender
Water Supply/Equipments/Meter/Drilling/Boring
Item Rate
180 days
Sivagangai
Refer Tender Documents
6 documents required · 6 mandatory
₹0
₹95,000
O/o The Project Director, DRDA, Sivagangai
7 Aug 2020
23 Jul 2020
29 Jul 2020
23 Jul 2020
29 Jul 2020
23 Jul 2020
27 Jul 2020
Amount
Providing New 20000 Ltr OHT, Pumping Main, Distribution Line, Pump Room and FHTC to Biramanakuruchi Village in Biramanakuruchi Panchayat in Ilayangudi block
CONSTRUCTION OF PUMP ROOM OF SIZE 1.50X1.50 (INNER)/CONVENTIONAL FOOTING)/2019-20
Earth work excavation & depositing on bank with an initial lead of 10 metre & initial lift of 2 metre in Hard shift clay, stiff block cotton, hard red earth shales, murrum, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil (SS 20B) for foundation including shoring, strutting, baling out water providing danger light wherever necessary depositing the surplus earth on bank and other incedential charges etc., complete and as directed by TWAD board Officers
Levelling course with P.C.C 1:4:8 (one cement, four sand and eigth course aggregate) using 40 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the TWAD Board Officers.
Earth filling in basement & sides of foundation with excavated earth including ramming and consolidation etc., complete
Supply and filling the foundation and basement with clear river sand in layers complying with standard specification including consolidation and watering etc. complete and as directed by TWAD Board Officers.
Brick work in CM 1:5 (one cement and five sand) using country bricks of size 8.75" X 4.25" X 2.00" including cost of all materials, labour charges, curing etc., complete and as directed by TWAD Board Officers.
For foundation and basement
For super structure
Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by TWAD Board Officers.
Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) excluding cost of steel fabrication,fixing in position and centring charges but including mixing,lifting and vibrating for SUNSHADE 75mm thick at wall face and 50mm thick at free end projecting 45cm from wall face moulded along with lintel etc. as directed by TWAD Board Officers.
Steel centering for soffits of RCC members including shuttering,strutting to the centring and providing supports etc.complete for the following members using MS Sheets of size 90cm x 60cm and BG 10 Gaugesstiffened with welded MS angles of size 25 x 25 x3mm laid over Silver Oak(country wood) joists of size 10 x 6.5 cm (spaced at about 90cm C/C) and supported by Casurania props of 10 cm to 13 cm dia. spaced at 75 cm C/C and as directed by TWAD Board Officers.The centring materials should be supplied and should be removed after the specified stripping time of the concrete as per IS 456/1978.
Plastering with C.M. 1:5(One part of cement and Five parts of sand) with 12mm thick over brickwork portion including labour charges for mixing finishing and curing etc., complete and as directed by TWAD Board Officers.
Special ceiling plastering for RCC Slab with C.M.1:3(One part of cement and Three parts of sand) 10mm thickover RCC surface including labour charges for mixing finishingand curing etc., complete as directed by TWAD Board Officers.
Flooring in C C 1:4:8 (one cement ,four sand and eight HBS) 10 cm thick using 40mm HBS metal and top finished with Cement mortar 1:3 (one cement and three sand) 12 mm thick including labour charges for mixing,finishing and curing etc. complete and as directed by TWAD Board Officers.
Supply and fixing of MS door (Single leaf) of sizes 1.00 x 2.00m in MS angle 50 x 50 x 4mm and MS flat 35 x 6mm with MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locing arrangements including two coats of approved enamel painting over one coat of primer
Supply, fabricating and fixing in position of RTS rods including cost of steel and binding wire etc., complete.
Supply and fixing of RCC box type jolly of size 0.6 x 0.45 m
Painting two coats with approved cement paint over one priming coat of white cement over cement plastered wall surface and ceiling including cleaning preparing the surface and curing etc., complete (using cement paint of colour as approved by the Departm
White washing two coats using fine screened shell lime for the new plastered surface for inner and outer side of the room including the cost of materials labour charges etc., complete and as directed by TWAD Board Officers.
Weathering Coarse over RCC roof including fixing one coarse of pressed tiles etc., complete.
Provision for writing TWAD Board emblem and scheme details on the side wall of the pump room
Provision of lock and key for pump room and OHT ladder
SUPPLY DELIVERY AND ERECTION OF SUBMERSIBLE PUMPSETS FOR INDIVIDUAL POWER PUMP SCHEME (BOREWELL)
Supply and delivery of vertical wet type submersible pumpset (5 HP) capable of discharging any of the following pumpage in lpm against noted head in m suitable for erection into the bore well/Inf. well / open well with stainless steel shaft, bronze impeller and starter.
Supply, delivery and erection of Submersible Pumpset of 50 LPMX 100m Head as per SOR TWAD - Page 88
Supply and delivery of 3 phase Panel Board D.O.L with two level guard and auto start confirming to IS specification for 1 HP pumpset. TWAD SOR Page 101
Supply, delivery of 1.1 KV Grade,PVC insulated and sheathed 3 core flat copper submersible cable with ISI marking conforming of IS 694/1990 of reputed make for submersible motor erected in borewell.
Sq.mm Copper cable page 109 II slno 2
Supply and Delivery of 1.1 KV grade 3 core Aluminum conductor U.G. cable conforming to IS 1554/part I and with ISI marking of reputed make for submersible motor erected in the Bore well/Open well page 109 I sl.no 2
Supply and delivery of GI medium class pipes and specials as per relevant IS as listed below.
50mm HDPE pipe
40mm GI Bend Heavy page 29
50mm GI Flangeset Heavy page 29
40mm MS Clampset Heavy page 29
50mm GM Non Return Valve page 30
50 x 40mm GI reducer heavy page 26
63mX50mm PVC T.Coupler page 10
40mm Ball Valve/ GM Gate Valve page 30
Obtaining power supply including cost of following materials and by engaging B licence holder.EB fee for application form and deposit amount will be borne by the Board
(i) Aerial fuse board of size 15 x 10 x 6cm with 32 A aerial fuse carrier(3 Nos.)
(iii)Wall mounting type MS cubical EB meter box with fuse carrier (3 Nos) of 32 A capacity at EB supply point.This box is also to accommodate TNEB energy meter with proper ventilation as approved by TNEB.
(ii) Supply and laying of 7/20 size PVC insulator copper conductor cable from Aerial fuse to EB supply point etc., complete as per I.E Rules.
25mm dia GI pipe for service point
25mm dia GI Elbow
No.8 GI wire for earth(Twin earthing)
Stay wire 7/20
20mm GI pipe for twin earthing and cable encasing
4way nutral link
TW banel board (41 x 31 x 6cm)
Labour charges for erection of submersible pump set including fixing and jointing the submersible cable with clamps to the required depth, valves and errection panel board control room twin earthing as per I.E Rules including cost of civil works
Upto 5 HP
MAINTANANCE OF OHT - SERVICE RESERVOIR - 30000 lit
Plastering with cement mortar 1:3 mix to 12mm thick including cost and conveyance of all materials to site and all labour charges etc
Exterior Emulsion painting two coats with best approved quality and colour paint over one coat of Base coat including cost and convyance of all materials to work site and labour charges etc., complete
Supply,Delivery,Laying and Jointing of 90mm HDPE Pipes for PUMPING MAIN LINE
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD HDPE Pipe
Conveying the HDPE Pipes and specials to trench lowering into the trenches, laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste and testing to the required pressure as per IS including conveyance etc
a. 90 mm OD HDPE Pipe
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD HDPE Pipe
Hydraulic field testing charges for HDPE Pipes as per Page No 258 Item No 11E
Hydraulic field testing charges
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
a.90mm HDPE Bend
b 90mm HDPE Tee
Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
a.80mm GI pipe
Supply and delivery of GI specials to site of work as per IS specification with ISI marking
a.80mm GI Elbow
b.80mm GI coupling
Laying and jointing of GI Pipes with GI specials and PVC specials etc
a.80mm dia Pipe
CONSTRUCTION OF OHT - SERVICE RESERVOIR - 20000 lit
Earthwork excavating and depositing on bank with an initial lead of 10 metres and initial lift of 2 metres in hard stiff clay, black cotton, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., SS 20B and as directed by TWAD Board Officers - for foundation
First depth of 2m
Second depth of 1m
Supply, Delivery and Filling with clean river sand complying with standard specification including watering ramming and consolidation etc., complete and as directed by TWAD Board Officers-for foundation.
Levelling coarse in cement concrete 1:4:8 (one cement,four sand and eight aggregate) using 40mm hard broken stone for foundation and leveling coarse including cost of all materials, mixing,placing, ramming, curing, finishing etc., complete and as directed by TWAD Board Officers. (Beyond 1.5 m to 4.5 m below GL)
Reinforced Cement Concrete using M30 Design mix with required cement, sand and 20 mm and 10 mm Machine crushed HBG stone including the cost of all materials, labour charges, mixing by using mechanical mixer machine, placing in position, lifting, vibrating by using mechanical vibrator, finishing & curing but excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges etc., complete and as directed by TWAD Board Officers.
For items 1.5m to 4.5m below GL
Items 0 to 1.5m below GL
above GL & Upto 4.5m
above 4.51m & upto 7.32m from GL
above 7.32m & upto 10.98m from GL
Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG 10 stiffened with MS angle of size 25 X 25 X 3mm for boarding laid over I type M.S. Truss of size 25x25x3 mm space at about 90cm c/c and supported by 40 mm GI pipe (Medium) spaced at 75cm c/c etc., complete and as directed by TWAD Board Officers.
Below G.L. items
0 to 3.30m above G.L.
Curved surface
Square columns
0 to 3.30m above G.L.
3.31 to 4.30m above G.L.
4.31 to 5.30m above G.L.
5.31 to 6.30m above G.L.
6.31 to 6.95m above G.L.
Applying two coats using approved cement paint including cost of one coat of white washing, cost of all materials, labour charges, etc., complete and as directed by TWAD Board Officers.
Supplying, fabricating and placing in position of Steel rods for reinforcement including cost of steel and binding wire and labour charges etc. complete for RCC works and as directed by TWAD Board Officers.
Supply and Delivery and fixing of outside MS Ladder of 45cm clear wide made out of 50 mm x 50mm x 6mm MS angle for sides and steps in 16 mm MS plain rods fixed at 30cm C/C welded jointed etc, providing with suitable side supports, clamps and locking arrangements provided with two coats of approved enamel paint over one coat of redoxide paint , for providing access to roof top of OHT of suitable inclined length , including bottom anchorage and transportation and as directed by TWAD Board officers. The rate includes concrete bed block in CC 1:2:4 using 20mm HBGS at top and bottom of suitable size with necessry anchor bolts, complete and as directed by TWAD Board Officers- For 7.5 m Staging height
Providing and fixing of RCC inside access ladder in RCC 1:1.5:3 (One cement, one and half sand and three aggregates) using 20mm HBG stone including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete curing etc., complete and as directed by TWAD Board Officers.
Providing and fixing of cut stone (Rough dressed) set in CM 1:3 of required size at site including cost of all materials, labour charges, curing etc., complete and as directed by TWAD Board Officers. (Size 0.30 x 0.30 x 0.15 m)
Supply, Delivery and fixing of CI Manhole frame with cover of following size including cost of all materials, fixing of MS clamps, Bolt and nuts etc.,complete and as directed by TWAD Board Officers. 0.60 x 0.60 (Heavy Duty)
Painting the Govnt Emblem and writing the slogon in accordance with size and specifications as approved by the TWAD Board Officers with approved colour and quality of paint on the exterior surface of Service Reservoir complete etc., and as directed by TWAD Board Officers.
Providing GI pipe connection arrangements for inlet, outlet scour and overflow etc. including cost of pipes, specials, valve, labour charge for lifting, aligning, cutting, threading, fixing and painting of GI pipes with two coats of approved quality enamel paint etc., complete and as directed by TWAD Board officers
50 mm G.I. Pipe
63 mm dia PVC Threaded coupler
50 mm G.I. Tee
50 mm G.I. Bend
50 mm dia G.I. Coupling
50 mm G.I. Flange set
50 mm G.I. Elbow
50 mmG.M. Gate Valve with wheel
Labour charges for pipe connection works
Refilling with excavated Soil (other than sand) in layers of not more than 15cm thick, watering, well ramming, consolidating, complying with standard specification and as directed by TWAD Board Officers.
Supply,Delivery,Laying and Jointing of 90mm PVC 4ksc Pipes for DISTRIBUTION MAIN LINE
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 90 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD PVC Pipe 4 KSC
Hydraulic field testing charges for PVC Pipes as per Page No 258 Item No 11E
Hydraulic field testing charges
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
90mm PVC Bend page 12 ,sl.no-3
90mm X 50mm PVC Threaded coupler page 10 SOR
90mm x50 mm PVC Tee IS 7834/1987 page 10
90mm End cap page 12 sl.no 11
Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
a.80mm GI pipe-page 25 sl.no 6
Supply and delivery of GI specials to site of work as per IS specification with ISI marking
a.80mm GI Elbow page 25 sl.no 1
b 80mm GI coupling page 25, sl.no 3
Laying and jointing of GI Pipes with GI specials and PVC specials etc
a.80 mm dia Pipe
C.C. Roads
Provision for gate value 80 mm
Provision for FHTC's(8 meter length per FHTC)
HSC Connection in PVC for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - PBrass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm) 15 mm
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm SS/brass tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
BT ROAD / WBM ROAD CUTTING CHARGES
Labour charges for Drilling,Cutting and fixing ferrules in distribution line
Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc
cutting MDPE Pipes and specials true axis and finishing the end complete
Supplying and fixing of flow controll valve with stainless body and hall
Supplying and fixing of Water Meter for Distribution Main Lines
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Water meter Dirt BOX
Water meter erection charges
Provision for pit for Gate Value 1000 X 900 mm
Electro Chloranation
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
Sub total
Providing New 20000 Ltr OHT, Pumping Main, Distribution Line and FHTC to Subash Nagar Village in Perumbatcheri Panchayat in Ilayangudi block
Supply,Delivery,Laying and Jointing of 90mm HDPE Pipes for PUMPING MAIN LINE
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD HDPE Pipe
Conveying the HDPE Pipes and specials to trench lowering into the trenches, laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste and testing to the required pressure as per IS including conveyance etc
a. 90 mm OD HDPE Pipe
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD HDPE Pipe
Hydraulic field testing charges for HDPE Pipes as per Page No 258 Item No 11E
Hydraulic field testing charges
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
a.90mm HDPE Bend
b 90mm HDPE Tee
Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
a.80mm GI pipe
Supply and delivery of GI specials to site of work as per IS specification with ISI marking
a.80mm GI Elbow
b.80mm GI coupling
Laying and jointing of GI Pipes with GI specials and PVC specials etc
a.80mm dia Pipe
CONSTRUCTION OF OHT - SERVICE RESERVOIR - 20000 lit
Earthwork excavating and depositing on bank with an initial lead of 10 metres and initial lift of 2 metres in hard stiff clay, black cotton, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., SS 20B and as directed by TWAD Board Officers - for foundation
First depth of 2m
Second depth of 1m
Supply, Delivery and Filling with clean river sand complying with standard specification including watering ramming and consolidation etc., complete and as directed by TWAD Board Officers-for foundation.
Levelling coarse in cement concrete 1:4:8 (one cement,four sand and eight aggregate) using 40mm hard broken stone for foundation and leveling coarse including cost of all materials, mixing,placing, ramming, curing, finishing etc., complete and as directed by TWAD Board Officers. (Beyond 1.5 m to 4.5 m below GL)
Reinforced Cement Concrete using M30 Design mix with required cement, sand and 20 mm and 10 mm Machine crushed HBG stone including the cost of all materials, labour charges, mixing by using mechanical mixer machine, placing in position, lifting, vibrating by using mechanical vibrator, finishing & curing but excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges etc., complete and as directed by TWAD Board Officers.
For items 1.5m to 4.5m below GL
Items 0 to 1.5m below GL
above GL & Upto 4.5m
above 4.51m & upto 7.32m from GL
above 7.32m & upto 10.98m from GL
Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG 10 stiffened with MS angle of size 25 X 25 X 3mm for boarding laid over I type M.S. Truss of size 25x25x3 mm space at about 90cm c/c and supported by 40 mm GI pipe (Medium) spaced at 75cm c/c etc., complete and as directed by TWAD Board Officers.
Below G.L. items
0 to 3.30m above G.L.
Curved surface
Square columns
0 to 3.30m above G.L.
3.31 to 4.30m above G.L.
4.31 to 5.30m above G.L.
5.31 to 6.30m above G.L.
6.31 to 6.95m above G.L.
Applying two coats using approved cement paint including cost of one coat of white washing, cost of all materials, labour charges, etc., complete and as directed by TWAD Board Officers.
Supplying, fabricating and placing in position of Steel rods for reinforcement including cost of steel and binding wire and labour charges etc. complete for RCC works and as directed by TWAD Board Officers.
Supply and Delivery and fixing of outside MS Ladder of 45cm clear wide made out of 50 mm x 50mm x 6mm MS angle for sides and steps in 16 mm MS plain rods fixed at 30cm C/C welded jointed etc, providing with suitable side supports, clamps and locking arrangements provided with two coats of approved enamel paint over one coat of redoxide paint , for providing access to roof top of OHT of suitable inclined length , including bottom anchorage and transportation and as directed by TWAD Board officers. The rate includes concrete bed block in CC 1:2:4 using 20mm HBGS at top and bottom of suitable size with necessry anchor bolts, complete and as directed by TWAD Board Officers- For 7.5 m Staging height
Providing and fixing of RCC inside access ladder in RCC 1:1.5:3 (One cement, one and half sand and three aggregates) using 20mm HBG stone including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete curing etc., complete and as directed by TWAD Board Officers.
Providing and fixing of cut stone (Rough dressed) set in CM 1:3 of required size at site including cost of all materials, labour charges, curing etc., complete and as directed by TWAD Board Officers. (Size 0.30 x 0.30 x 0.15 m)
Supply, Delivery and fixing of CI Manhole frame with cover of following size including cost of all materials, fixing of MS clamps, Bolt and nuts etc.,complete and as directed by TWAD Board Officers. 0.60 x 0.60 (Heavy Duty)
Painting the Govnt Emblem and writing the slogon in accordance with size and specifications as approved by the TWAD Board Officers with approved colour and quality of paint on the exterior surface of Service Reservoir complete etc., and as directed by TWAD Board Officers.
Providing GI pipe connection arrangements for inlet, outlet scour and overflow etc. including cost of pipes, specials, valve, labour charge for lifting, aligning, cutting, threading, fixing and painting of GI pipes with two coats of approved quality enamel paint etc., complete and as directed by TWAD Board officers
50 mm G.I. Pipe
63 mm dia PVC Threaded coupler
50 mm G.I. Tee
50 mm G.I. Bend
50 mm dia G.I. Coupling
50 mm G.I. Flange set
50 mm G.I. Elbow
50 mmG.M. Gate Valve with wheel
Labour charges for pipe connection works
Refilling with excavated Soil (other than sand) in layers of not more than 15cm thick, watering, well ramming, consolidating, complying with standard specification and as directed by TWAD Board Officers.
Supply,Delivery,Laying and Jointing of 90mm PVC 4ksc Pipes for DISTRIBUTION MAIN LINE
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 90 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD PVC Pipe 4 KSC
Hydraulic field testing charges for PVC Pipes as per Page No 258 Item No 11E
Hydraulic field testing charges
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
90mm PVC Bend page 12 ,sl.no-3
90mm X 50mm PVC Threaded coupler page 10 SOR
90mm x50 mm PVC Tee IS 7834/1987 page 10
90mm End cap page 12 sl.no 11
Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
a.80mm GI pipe-page 25 sl.no 6
Supply and delivery of GI specials to site of work as per IS specification with ISI marking
a.80mm GI Elbow page 25 sl.no 1
b 80mm GI coupling page 25, sl.no 3
Laying and jointing of GI Pipes with GI specials and PVC specials etc
a.80 mm dia Pipe
C.C. Roads
Provision for gate value 80 mm
Provision for FHTC's(8 meter length per FHTC)
HSC Connection in PVC for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - PBrass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm) 15 mm
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm SS/brass tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
BT ROAD / WBM ROAD CUTTING CHARGES
Labour charges for Drilling,Cutting and fixing ferrules in distribution line
Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc
cutting MDPE Pipes and specials true axis and finishing the end complete
Supplying and fixing of flow controll valve with stainless body and hall
Supplying and fixing of Water Meter for Distribution Main Lines
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Water meter Dirt BOX
Water meter erection charges
Provision for pit for Gate Value 1000 X 900 mm
Electro Chloranation
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
Sub total
Providing New 20000 Ltr OHT, Pumping Main, Distribution Line and FHTC to Sethupathi Nagar Village in Perumbatcheri Panchayat in Ilayangudi block
Supply,Delivery,Laying and Jointing of 90mm HDPE Pipes for PUMPING MAIN LINE
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD HDPE Pipe
Conveying the HDPE Pipes and specials to trench lowering into the trenches, laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste and testing to the required pressure as per IS including conveyance etc
a. 90 mm OD HDPE Pipe
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD HDPE Pipe
Hydraulic field testing charges for HDPE Pipes as per Page No 258 Item No 11E
Hydraulic field testing charges
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
a.90mm HDPE Bend
b 90mm HDPE Tee
Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
a.80mm GI pipe
Supply and delivery of GI specials to site of work as per IS specification with ISI marking
a.80mm GI Elbow
b.80mm GI coupling
Laying and jointing of GI Pipes with GI specials and PVC specials etc
a.80mm dia Pipe
CONSTRUCTION OF OHT - SERVICE RESERVOIR - 20000 lit
Earthwork excavating and depositing on bank with an initial lead of 10 metres and initial lift of 2 metres in hard stiff clay, black cotton, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., SS 20B and as directed by TWAD Board Officers - for foundation
First depth of 2m
Second depth of 1m
Supply, Delivery and Filling with clean river sand complying with standard specification including watering ramming and consolidation etc., complete and as directed by TWAD Board Officers-for foundation.
Levelling coarse in cement concrete 1:4:8 (one cement,four sand and eight aggregate) using 40mm hard broken stone for foundation and leveling coarse including cost of all materials, mixing,placing, ramming, curing, finishing etc., complete and as directed by TWAD Board Officers. (Beyond 1.5 m to 4.5 m below GL)
Reinforced Cement Concrete using M30 Design mix with required cement, sand and 20 mm and 10 mm Machine crushed HBG stone including the cost of all materials, labour charges, mixing by using mechanical mixer machine, placing in position, lifting, vibrating by using mechanical vibrator, finishing & curing but excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges etc., complete and as directed by TWAD Board Officers.
For items 1.5m to 4.5m below GL
Items 0 to 1.5m below GL
above GL & Upto 4.5m
above 4.51m & upto 7.32m from GL
above 7.32m & upto 10.98m from GL
Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG 10 stiffened with MS angle of size 25 X 25 X 3mm for boarding laid over I type M.S. Truss of size 25x25x3 mm space at about 90cm c/c and supported by 40 mm GI pipe (Medium) spaced at 75cm c/c etc., complete and as directed by TWAD Board Officers.
Below G.L. items
0 to 3.30m above G.L.
Curved surface
Square columns
0 to 3.30m above G.L.
3.31 to 4.30m above G.L.
4.31 to 5.30m above G.L.
5.31 to 6.30m above G.L.
6.31 to 6.95m above G.L.
Applying two coats using approved cement paint including cost of one coat of white washing, cost of all materials, labour charges, etc., complete and as directed by TWAD Board Officers.
Supplying, fabricating and placing in position of Steel rods for reinforcement including cost of steel and binding wire and labour charges etc. complete for RCC works and as directed by TWAD Board Officers.
Supply and Delivery and fixing of outside MS Ladder of 45cm clear wide made out of 50 mm x 50mm x 6mm MS angle for sides and steps in 16 mm MS plain rods fixed at 30cm C/C welded jointed etc, providing with suitable side supports, clamps and locking arrangements provided with two coats of approved enamel paint over one coat of redoxide paint , for providing access to roof top of OHT of suitable inclined length , including bottom anchorage and transportation and as directed by TWAD Board officers. The rate includes concrete bed block in CC 1:2:4 using 20mm HBGS at top and bottom of suitable size with necessry anchor bolts, complete and as directed by TWAD Board Officers- For 7.5 m Staging height
Providing and fixing of RCC inside access ladder in RCC 1:1.5:3 (One cement, one and half sand and three aggregates) using 20mm HBG stone including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete curing etc., complete and as directed by TWAD Board Officers.
Providing and fixing of cut stone (Rough dressed) set in CM 1:3 of required size at site including cost of all materials, labour charges, curing etc., complete and as directed by TWAD Board Officers. (Size 0.30 x 0.30 x 0.15 m)
Supply, Delivery and fixing of CI Manhole frame with cover of following size including cost of all materials, fixing of MS clamps, Bolt and nuts etc.,complete and as directed by TWAD Board Officers. 0.60 x 0.60 (Heavy Duty)
Painting the Govnt Emblem and writing the slogon in accordance with size and specifications as approved by the TWAD Board Officers with approved colour and quality of paint on the exterior surface of Service Reservoir complete etc., and as directed by TWAD Board Officers.
Providing GI pipe connection arrangements for inlet, outlet scour and overflow etc. including cost of pipes, specials, valve, labour charge for lifting, aligning, cutting, threading, fixing and painting of GI pipes with two coats of approved quality enamel paint etc., complete and as directed by TWAD Board officers
50 mm G.I. Pipe
63 mm dia PVC Threaded coupler
50 mm G.I. Tee
50 mm G.I. Bend
50 mm dia G.I. Coupling
50 mm G.I. Flange set
50 mm G.I. Elbow
50 mmG.M. Gate Valve with wheel
Labour charges for pipe connection works
Refilling with excavated Soil (other than sand) in layers of not more than 15cm thick, watering, well ramming, consolidating, complying with standard specification and as directed by TWAD Board Officers.
Supply,Delivery,Laying and Jointing of 90mm PVC 4ksc Pipes for DISTRIBUTION MAIN LINE
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 90 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD PVC Pipe 4 KSC
Hydraulic field testing charges for PVC Pipes as per Page No 258 Item No 11E
Hydraulic field testing charges
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
90mm PVC Bend page 12 ,sl.no-3
90mm X 50mm PVC Threaded coupler page 10 SOR
90mm x50 mm PVC Tee IS 7834/1987 page 10
90mm End cap page 12 sl.no 11
Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
a.80mm GI pipe-page 25 sl.no 6
Supply and delivery of GI specials to site of work as per IS specification with ISI marking
a.80mm GI Elbow page 25 sl.no 1
b 80mm GI coupling page 25, sl.no 3
Laying and jointing of GI Pipes with GI specials and PVC specials etc
a.80 mm dia Pipe
C.C. Roads
Provision for gate value 80 mm
Provision for FHTC's(8 meter length per FHTC)
HSC Connection in PVC for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - PBrass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm) 15 mm
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm SS/brass tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
BT ROAD / WBM ROAD CUTTING CHARGES
Labour charges for Drilling,Cutting and fixing ferrules in distribution line
Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc
cutting MDPE Pipes and specials true axis and finishing the end complete
Supplying and fixing of flow controll valve with stainless body and hall
Supplying and fixing of Water Meter for Distribution Main Lines
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Water meter Dirt BOX
Water meter erection charges
Provision for pit for Gate Value 1000 X 900 mm
Electro Chloranation
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
Sub total
Providing Distribution Line and FHTC to Sathanoor Village in Sathanoor Panchayat in Ilayangudi block
Supply,Delivery,Laying and Jointing of 90mm PVC 4ksc Pipes for DISTRIBUTION MAIN LINE
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 90 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD PVC Pipe 4 KSC
Hydraulic field testing charges for PVC Pipes as per Page No 258 Item No 11E
Hydraulic field testing charges
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
90mm PVC Bend page 12 ,sl.no-3
90mm X 50mm PVC Threaded coupler page 10 SOR
90mm x50 mm PVC Tee IS 7834/1987 page 10
90mm End cap page 12 sl.no 11
Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
a.80mm GI pipe-page 25 sl.no 6
Supply and delivery of GI specials to site of work as per IS specification with ISI marking
a.80mm GI Elbow page 25 sl.no 1
b 80mm GI coupling page 25, sl.no 3
Laying and jointing of GI Pipes with GI specials and PVC specials etc
a.80 mm dia Pipe
C.C. Roads
Provision for gate value 80 mm
Provision for FHTC's(8 meter length per FHTC)
HSC Connection in PVC for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - PBrass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm) 15 mm
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm SS/brass tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
BT ROAD / WBM ROAD CUTTING CHARGES
Labour charges for Drilling,Cutting and fixing ferrules in distribution line
Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc
cutting MDPE Pipes and specials true axis and finishing the end complete
Supplying and fixing of flow controll valve with stainless body and hall
Supplying and fixing of Water Meter for Distribution Main Lines
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Water meter Dirt BOX
Water meter erection charges
Provision for pit for Gate Value 1000 X 900 mm
Electro Chloranation
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
Sub total
Providing Distribution Line and FHTC to Kattidam Village in Sathanoor Panchayat in Ilayangudi block
Supply,Delivery,Laying and Jointing of 90mm PVC 4ksc Pipes for DISTRIBUTION MAIN LINE
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 90 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD PVC Pipe 4 KSC
Hydraulic field testing charges for PVC Pipes as per Page No 258 Item No 11E
Hydraulic field testing charges
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
90mm PVC Bend page 12 ,sl.no-3
90mm X 50mm PVC Threaded coupler page 10 SOR
90mm x50 mm PVC Tee IS 7834/1987 page 10
90mm End cap page 12 sl.no 11
Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
a.80mm GI pipe-page 25 sl.no 6
Supply and delivery of GI specials to site of work as per IS specification with ISI marking
a.80mm GI Elbow page 25 sl.no 1
b 80mm GI coupling page 25, sl.no 3
Laying and jointing of GI Pipes with GI specials and PVC specials etc
a.80 mm dia Pipe
C.C. Roads
Provision for gate value 80 mm
Provision for FHTC's(8 meter length per FHTC)
HSC Connection in PVC for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - PBrass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm) 15 mm
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm SS/brass tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
BT ROAD / WBM ROAD CUTTING CHARGES
Labour charges for Drilling,Cutting and fixing ferrules in distribution line
Supply and delivery of the MS clamp and fixing in wall in open space with required screw etc
cutting MDPE Pipes and specials true axis and finishing the end complete
Supplying and fixing of flow controll valve with stainless body and hall
Supplying and fixing of Water Meter for Distribution Main Lines
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Water meter Dirt BOX
Water meter erection charges
Provision for pit for Gate Value 1000 X 900 mm
Electro Chloranation
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
R.Rajasekaran
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .