Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.4 LAccepted-AOC 1 27 27 CRESCENT PLAZA HARBOUR EXPRESS ROAD THERMAL NAGAR POST NEAR CAMP I TUTICORIN 628006 | TUTICORIN | TUTICORIN | TAMIL NADU | 628006 | 1 | Accepted-AOC L1 | |
| 2 | 2₹3.8 L+₹23,787 (6.63%)Rejected-AOC | 2 | Rejected-AOC L2 |
Tender Value
₹4.7 L
EMD Value
₹4,600
Closing Date
18 Aug 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE M II / TTPS
Superintending Engineer, Mechanical-II, Tuticorin Thermal Power Station, Tuticorin
TTPS Mech II TM I Overhauling of Refrigeration type air drier plant Unit I II III
2022_EB_243381_1
SE / M-II /TTPS Spec.No.197/2022-23
Open Tender
Miscellaneous Works
Item Rate
7 days
TTPS
As per BQR conditions in NIT
7 documents required · 7 mandatory
₹0
₹4,600
Yes
17 Apr 2023
22 Jul 2022
20 Aug 2022
22 Jul 2022
18 Aug 2022
22 Jul 2022
Charges for Dismantling, conducting pressure leak test in the chiller unit and Rectification of leak if any: Charges for dismantling the chiller unit chamber and check the pressure leak test using Nitrogen gas, Removal of chiller unit shell from the chamber and idendification of gas leak in the copper tubes if any, arresting of leaks in the copper tubes if any including cutting and gas welding, assembling of chiller unit shell with the chamber after rectification including cost of materials.
Charges for overhauling of prechamber : Charges for disconnection of inlet & outlet pipe lines, removal of the Pre chamber from drier unit, cleaning of oil & moisture content in the pre chamber by using instrument air, replacement of worn out gaskets and reassembling of pre chamber.
Charges for overhauling of condenser, drier & receiver: Charges for disconnection of inlet & outlet pipe lines, removal of condenser from the drier and check the pressure leak test using Nitrogen gas, arresting of leaks in the copper tubes if any including cutting and gas welding, cleaning of condenser, drier & receiver and Reassembling of condenser.
Charges for Replacement of defective 3 Phase sealed unit Compressor (If Required) : Charges for disconnection and reconnections of power cables, disconnection & reconnection of inlet & outlet pipe lines, removal of defective compressor and erection of new compressor (3 Phase sealed unit Compressor 1.5 Ton 3225 KCAL suitable for HFC 404 ) including charges for cutting, grinding, welding.
Charges for assembling and commissioning the drier unit into service : Charges for assembling of new spare chiller unit, conducting the pressure leak test, filling of Freon gas into the gas circuit, commissioning the drier unit into service.
CRESCENT ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .