Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC AOC PLACED ON L1 BIDDER WITH CONTRACT AGREEMENT NO GE/SHL/21 OF 2022-2023 | |
| 2 | L2₹34.5 L+₹1.4 L (4.30%)Rejected-Finance C O RANJIT ELECTRICAL KEATING ROAD SHILLONG 793001 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793001 | L2 | Rejected-Finance Reject being L2 bidder | |
| 3 | L3₹34.8 L+₹1.7 L (5.24%)Rejected-Finance C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L3 | Rejected-Finance Reject being L3 bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Oct 2022, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG DIVISION PIN 793002
REPAIR MAINTENANCE TO WOODEN STEEL PVC AND ALUMINIUM JOINERY ROOF SHEETING CEILING TRUSS AND PURLIN ROOF TREATMENT CLEANING OF WATER TANKS AND OTHER ALLIED WORKS OF BLDGS OF ARC MES MDC AND 11 WEU AT HAPPY VALLEY UNDER GE SHILLONG
2022_MES_532291_3
GE /SH L/ TOKEN 34 OF 2021-22
Open Tender
Civil Works
Works
240 days
GE SHILLONG
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE SHILLONG
₹70,000
Yes
1 Dec 2022
16 Sept 2022
10 Oct 2022
16 Sept 2022
8 Oct 2022
23 Sept 2022
Amount
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc. (ii) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm.
M& L for Roof treatment work including wire brushing and cleaning the top surfaces of roof including flashing and surface painting with a layer of blown bitumen of any penetration by using blown bitumen @ 1.7Kg /Sqm , lightly tampered (area of flashings etc shall be added to the roof area) and providing APP membrane 3mm thick (minimum) , weighing 3.5Kg/Sqm reinforced with polyster non woven fabric (weighing not less than 160 gm/Sqm) shalll be appliex by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction including taking out old unserviceable roof treatment works complete all as specified and directed.
Supply only for water proofing compound.
S&F of 0.63 mm thick galvanized corrugated iron (CGI) sheeting with two corrugation side lap sheets having zinc coating @ 120 gram per sqm inclusive of both sides, fixed with coach screws and washers as in roof covering etc including dismantling any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F 0.80 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters,drip and straight flashings (length and girth as fixed) with grade of zinc coating 120 gram per sqm including dismantling any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specifid and as directed.
Refixing only 0.63 mm thick galvanized corrugated iron (CGI) sheeting with two corrugation side lap sheets having zinc coating @ 120 gram per sqm inclusive of both sides, fixed with coach screws and washers as in roof covering etc. including dismantling any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as including dismantling corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as including dismantling plain steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as including dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. specified
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as including dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Demolition of cement Concrete (RCC chimney) of any description and in any position not otherwise specifically provided for complete all as specified.
Cleaning of service water tank capacity upto 500ltr RCC/PVC and the connected circulating pipes at any position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots etc or any other foreign material from the bottom, cover and internal surfaces by scraping using wire brush, draining out the water in the tank and washing internally by using bleaching powder and again draining out the water in the tank and applying single coat of lime washing on RCC tanks( Rate includes cost of writing date of cleaning with paint after removing the old date by painting including disconnecting existing tanks,setting aside (or lowering if reqiured) for repairs cleaning etc and hoisting if required reconnecting and re-fixing in same position of capacity of water tanks of Exc 250 Ltrs & N.exc 500Ltrs all complete). all as directed by Engineer-in-charge
All as per item no-12 above but exc 500 and n.exc 1000 complete all as specified and directed.
S & F 500 litres capacity, rotational moulded, polythene (white colour), triple layered water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling completeall as specified and as directed. Make : Sintex, Polycon, waterwell.
S & F 1000 litres capacity rotational moulded, polythene (white colour), tripe layered water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling completeall as specified and as directed. Make : Sintex, Polycon, waterwell.
S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S & F 15 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors including taking down up or down complete all as specified and directed.
S & F 20 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors including taking down complete all as specified and directed.
Refixing 15 mm bore old steel tubing but with new GI fittings after cleaning the pipe, in new or old position ( wall, ceiling or floor) including taking up or down complete all as specified and directed.
Refixing 20 mm bore old steel tubing but with new GI fittings after cleaning the pipe, in new or old position ( wall, ceiling or floor) including taking up or down complete all as specified and directed.
M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete.
M&L for Non-skid ceramic colour tiles (premium/special quality) 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:6 including dismantling floor/hearth or wall tilling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off premises complete all as specified and as directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including 15 mm thick screed bed or bedding layer in cement mortar 1:6 including dismantling floor/hearth or wall tilling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off premises complete all as specified and as directed.
M&L for Vitrified ceramic tiles light shade, 10 mm thick (square/rectangular) polished, area of each tiles n. exc 0.36 Sqm in floors, set and jointed in cement slurry and pointed in white or colour cement to match over and including screed bed 15 mm thick in cement sand mortar 1:4 including dismantling floor/hearth or wall tilling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off premises complete all as specified and as directed.
M & L for glazed ceramic coloured tiles 350 mm X 250 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles including 10mm thick rendring in CM (1:4) on fair faces of brick or concrete on vertical surfaces of wall including dismantling floor/hearth or wall tilling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off premises complete all as specified and directed.
M&L for Glazed ceramic colour tiles of size 450 x 300 x 7mm thick (premium/special quality) in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 including dismantling floor/hearth or wall tilling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off premises complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded agg) as in sub base including demolition of plain cement concrete (unreinforced) in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls including clamps for securing pipe and taking down old pipe complete all as specified and directed.
S & F 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls including clamps for securing pipe and taking down old pipe complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) branch piece, single (Single ‘Y’ or 'T') equal or unequal complete all as specified and directed
S & F in repair 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all specified and as directed.
S&F in repair for Grating doom 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed.
S & F in repair PVC low level white flushing cistern 9/10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle, 32 mm dia PVC flush pipe of suitable length and making all connection and making good disturbed surface complete all as specified and directed.
S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F in repairs 600 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
Supply and fix in repair vitreous china squatting pan, "Orissa" pattern, size 580x440mm, white, integral front or back inlet and foot rest (excluding flushing cistern and flush pipe) including provision of lime concrete bedding and making good to floor complete all as specified and directed.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S & F of 2nd class hard wood scantling, clean sawn in any position and any description as in unframed work including dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed workcomplete all as specified and directed.
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with nails as in ceiling including dismantling wall & ceiling boards of any description including cover fillets complete all as specified and directed.
Dismantling timber scantling in fillets, rails, posts, rafters/purlins under 40 sqcm in section complete all as specified and directed.
S&F 2nd class HW plain fillets square rectangular triangular in section, clean sawn secured with nails section area exc. 13 sqcm but n.exc 25 sqcm
S&F 2nd class HW plain fillets square rectangular triangular in section, clean sawn secured with nails sectiona area exc 6 sqcm & n.exc 13 sqcm complete all as specified and directed..
M&L for preparation of surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with two coats of creosote oil complete complete all as specified and directed.
M&L for preparation of surfaces of any description n.exc 10 cm width/girth not otherwise descibed & applying two coats of Synthetic Enamel paint over a coat of pink primer wooden surface complete all as specified and directed.
M&L for preparation of new surfaces and applying two coats of distemper on ceiling complete all as specified and directed.
S&F false ceiling of Non asbestos fibre decorative cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 605 mm x 605 mm x 4 mm thick fixed over and including anodised aluminium powder coated (minimum thickness of powder coating 50 micron) snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 605mm X 605mm.The aluminium frame work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long including dismantling wall & ceiling boards of any description including cover fillets complete all as specified directed by the Engineer-in-Charge. Make : Everest or equivalent as approved by GE
S&F in repair 20 mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
S&F in repair 25 mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
S & F in repairs to 600mm long PVC flexible Waste pipe to WHB/urinals/Sink complete all as specified and as directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame not exc 1.50 sqm & removing from site complete all as specified and directed.
Taking down shutter of any description n.exc 1 Sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but not exc 2.00 sqm each complete all as specified and directed.
Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
Supply and fixing 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S & F 30mm thick II class HW Glazed and skeleton windows, ventilators, etc are provided with stiles and rails as specified in SSR Part I section 8 clause 8.24 (b) all specified and directed.
Supply and fixing Flush shutters, solid core construction 35mm thick with block board core and plywood face panels, commercial type on both sides conforming to IS-2202(Part-I), 1983 complete all as specified and directed.
Supply and fixing 2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and directed.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
Supply and fix Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes all around . M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, all as specified.
Supply and Fix Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
Supply and Fix Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
Supply and Fix Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified and directed.
S & F Anodised aluminium window and ventilator shutters, movable (minimum two track) type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, handle , rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
S & F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F in repairs door closer hydraulically regulated, cast iron body, designation no. 3, universal type, suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
S&F in repair mild steel as a small article as a hold fast or similar items complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded aggregate) as in steel frame filling/hold fast blocking incl necessary form work complete all as specified and directed.
Forming jambs, etc. to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed.
S&F 100 mm size butt hinges cold rolled medium weight for door shutters complete all as specified and directed.
S & F Mild steel sliding door bolts of size 250 mm, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
Supply and fixing 200mm size MS barrel tower bolt stove enamelled black with bright bolt ISI marked complete all as specified and directed.
Supply and fixing 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
S & F 150mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F 150mm long aluminium handle fabricated type anodised all as specified and as directed .
S&F 75 mm size butt hinges cold rolled medium weight for windows/ventilators complete all as specified and directed.
S&F in repairs 75 mm size butt hinges cold rolled medium weight for windows/ventilators complete all as specified and directed.
S&F 100 mm size MS barrel tower bolt stove enamelled black with bright bolt complete all as specified and directed.
S&F 100 mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
S&F in repairs galvanised MS wire cloth 0.56mm nominal dia of wire and average width aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beads complete all as specified and as directed.
S&F Sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
S&F one side frosted glass 3 mm thick, glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
S&F Sheet glass 4.80 mm thick, ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
Removal of plant/vegetation/bushes growth etc froom roof or parapet of building including removing of root and making good disturbed surface with cement mortar 1:3 including mixing only liquid waterproofing compound as per manufacturer instruction complete all as specified and directed.
M/S MANOJ KUMAR BAL
S K Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .