Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAdmitted-Finance | ₹5.4 L | L1 | Admitted-Finance |
| 2 | L2₹5.9 LAdmitted-Finance | ₹5.9 L | L2 | Admitted-Finance |
| 3 | L3₹7.1 LAdmitted-Finance | ₹7.1 L | L3 | Admitted-Finance |
| 4 | L4₹7.1 LAdmitted-Finance | ₹7.1 L | L4 | Admitted-Finance |
| 5 | L5₹7.6 LAdmitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA UDYAM UP 56 0002873 09AARFP4205H1Z1 R M | MEERUT | UTTAR PRADESH | 250103 | ₹7.6 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Super System Engineers L6 | HYDROCON ENGINEERS L3 | Shakti Trading Co. L7 | Premier Engineering Company L5 | Raj Engineering Co. L4 | ANKIT SINGH TARAR L2 | Gupta Brothers L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.01 | Dismantling the old damaged LT panel with the help of gas cutter and heavy manual labour. After taking shut down from BSES and dismantling all cable connections as required at site. | 1 | Job | 9,260 ₹10,926.8 | 5,000 ₹5,900 | 9,450 ₹11,151 | 7,500 ₹8,850 | 5,500 ₹6,490 | 5,000 ₹5,900 | 3,000 ₹3,540 |
| 1.02 | LT Distribution panel sheet enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing , floor mounted type, dust & vermin proof , outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gasket. The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components assemblies and sub equipments of the panel will be as per standard given in relevant IS. size approx. 2000mm x 1800mm x 350mm Having following components of approved make. | 1 | No. | 67,030 ₹79,095.4 | 1,08,000 ₹1,27,440 | 68,000 ₹80,240 | 98,000 ₹1,15,640 | 69,000 ₹81,420 | 24,000 ₹28,320 | 80,000 ₹94,400 |
| 1.03 | Supply of triple pole Contactor 140 amp with No+Nc make: L&T/BCH/Havells/HPL/Any DJB approved make. | 6 | Nos. | 76,620 ₹90,411.6 | 39,000 ₹46,020 | 78,000 ₹92,040 | 85,500 ₹1,00,890 | 1,13,400 ₹1,33,812 | 39,000 ₹46,020 | 8,400 ₹9,912 |
| 1.04 | Supply of triple pole Contactor 95 amp with No+Nc make: L&T/BCH/ Havells/HPL/Any DJB approved make. | 3 | Nos. | 20,265 ₹23,912.7 | 16,500 ₹19,470 | 20,700 ₹24,426 | 33,600 ₹39,648 | 38,940 ₹45,949.2 | 13,500 ₹15,930 | 24,000 ₹28,320 |
| 1.05 | Supply of Thermal overload relay 90-150 amp as required make: L&T/BCH/ Havells/HPL /Any DJB approved make. | 3 | Nos. | 13,755 ₹16,230.9 | 16,500 ₹19,470 | 14,100 ₹16,638 | 15,420 ₹18,195.6 | 20,100 ₹23,718 | 19,500 ₹23,010 | 21,000 ₹24,780 |
| 1.06 | Supply of Electronic Timer in the LT panel make: L&T/BCH/Havells/HPL/Any DJB approved make. | 3 | Nos. | 7,005 ₹8,265.9 | 7,500 ₹8,850 | 7,170 ₹8,460.6 | 2,370 ₹2,796.6 | 3,300 ₹3,894 | 3,600 ₹4,248 | 9,000 ₹10,620 |
| 1.07 | Supply of Signal Phase preventer (SPP) in the LT panel. Make - L&T/BCH/Havells/HPL/Any DJB approved make. | 3 | Nos. | 7,908 ₹9,331.44 | 7,500 ₹8,850 | 8,100 ₹9,558 | 2,340 ₹2,761.2 | 2,250 ₹2,655 | 4,500 ₹5,310 | 3,000 ₹3,540 |
| 1.08 | Supply of Electronic Motor Protection Relay with in- built Earth Fault Protection make: L&T / BCH / Havells / HPL /Any DJB approved make. | 3 | Nos. | 52,845 ₹62,357.1 | 22,500 ₹26,550 | 54,000 ₹63,720 | 25,350 ₹29,913 | 14,100 ₹16,638 | 24,000 ₹28,320 | 24,000 ₹28,320 |
| 1.09 | Supply of triple pole Changeover switch of 400Amp 4P capacity with spreader for operation and safety of individual feeders by rotary handle- Make :- L&T/BCH/Havells / HPL/Any DJB approved make. | 4 | Nos. | 71,380 ₹84,228.4 | 50,000 ₹59,000 | 72,000 ₹84,960 | 84,800 ₹1,00,064 | 95,200 ₹1,12,336 | 96,000 ₹1,13,280 | 60,000 ₹70,800 |
| 1.10 | Supply of triple pole MCCB of 400 A 4P capacity with safety of individual feeders with the help of rotary handle - Make L&T/BCH / Havells / HPL/Any DJB approved make. | 1 | No. | 32,920 ₹38,845.6 | 11,500 ₹13,570 | 33,000 ₹38,940 | 21,500 ₹25,370 | 24,800 ₹29,264 | 26,000 ₹30,680 | 12,000 ₹14,160 |
Tender Value
Refer Docs
EMD Value
₹16,500
Closing Date
27 Jan 2026, 3:00 pmClosed
Office of the Ex. Eng. (E and M) M-2
Pocket-A, Dilshad Garden, Delhi-110095
SITC of LT Panel board with allied works at W-II Ranney well near Nanksar Gurudwara at Wazirabad road.
2026_DJB_285135_5
NIT No. 23 (25-26)
Open Tender
Miscellaneous Works
60 days
Nanksar Gurudwara at Wazirabad road.
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Ac No. 50448339804
₹16,500
18 Mar 2026
19 Jan 2026
27 Jan 2026
19 Jan 2026
27 Jan 2026
19 Jan 2026
Dismantling the old damaged LT panel with the help of gas cutter and heavy manual labour. After taking shut down from BSES and dismantling all cable connections as required at site.
LT Distribution panel sheet enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing , floor mounted type, dust & vermin proof , outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gasket. The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components assemblies and sub equipments of the panel will be as per standard given in relevant IS. size approx. 2000mm x 1800mm x 350mm Having following components of approved make.
Supply of triple pole Contactor 140 amp with No+Nc make: L&T/BCH/Havells/HPL/Any DJB approved make.
Supply of triple pole Contactor 95 amp with No+Nc make: L&T/BCH/ Havells/HPL/Any DJB approved make.
Supply of Thermal overload relay 90-150 amp as required make: L&T/BCH/ Havells/HPL /Any DJB approved make.
Supply of Electronic Timer in the LT panel make: L&T/BCH/Havells/HPL/Any DJB approved make.
Supply of Signal Phase preventer (SPP) in the LT panel. Make - L&T/BCH/Havells/HPL/Any DJB approved make.
Supply of Electronic Motor Protection Relay with in- built Earth Fault Protection make: L&T / BCH / Havells / HPL /Any DJB approved make.
Supply of triple pole Changeover switch of 400Amp 4P capacity with spreader for operation and safety of individual feeders by rotary handle- Make :- L&T/BCH/Havells / HPL/Any DJB approved make.
Supply of triple pole MCCB of 400 A 4P capacity with safety of individual feeders with the help of rotary handle - Make L&T/BCH / Havells / HPL/Any DJB approved make.
Supply of triple pole MCCB of 200- 250 A 3P capacity with safety of individual feeders by rotary handle- Make :- L&T / BCH / Havells / HPL /Any DJB approved make.
Supply of spreader for MCCB of 200-250 A 3P capacity for operation and safety of individual feeders- Make - L&T / BCH / Havells / HPL /Any DJB approved make.
Supply of spreader for MCCB of 400 A 4P capacity for operation and safety of individual feeders- Make - L&T / BCH / Havells / HPL /Any DJB approved make.
Supply of Handle for MCCB of 250 A capacity for operation and safety of individual feeders- Make - L&T / BCH / Havells / HPL /Any DJB approved make.
Supply of Handle for MCCB of 400 A capacity for operation and safety of individual feeders- Make - L&T / BCH / Havells / HPL /Any DJB approved make.
Supply of 6-32A SP MCB for operation of LED light. Make: L&T / BCH / Havells/ HPL /Any DJB approved make.
Supply of 6-32A TP MCB for operation of LED light. Make: L&T / BCH / Havells / HPL /Any DJB approved make.
Supply of start/stop push button as required. Make: L&T / BCH / Havells / HPL /Any DJB approved make..
Supply of indicating lamp red/yellow/blue as required. Make: L&T / BCH / Havells / HPL /Any DJB approved make.
Supply of Terminal block 6 way as required. Make: L&T / BCH / Havells / HPL / Any DJB approved make.
Supply of bus bar of the panel will be shaped out of high conductivity, electrolyte conductor and shall be liberal sized in aluminum with R/Y/B indication
Fixing of all above components in the LT panel with suitable fabrication work to accommodate new items in the existing feeders for alignment of components and ease of termination complete with hardware etc. The control wiring of the panel will be done with PVC flexible copper wires of 2.5mm cross section. Each wire will be terminating with a ferule crimped to the wire as required at site
Fixing of LT panel by civil/Mechanical work and making all cable connection as required The panel will have MS angle stand in 50x50x5mm size as required
Testing & commissioning of LT Stater Panel as per required parameters including following :- i. Continuity and earth test, ii. Programming of Electronic Motor Protection Relay. Meggering of all equipment's for phase to phase and phase to earth. iii. Checking of tightness of all nut and bolts. iv. Monitoring of power factor
Dismantling of old damaged components of APFC panel with such as capacitors, MCB's bus bars, inter-connections termination and mounting hardware etc.
Supply/Fixing of heavy duty capacitors, rated at 415V 50Hz 3 phase AC MPP type complete with discharge device and terminal cover, Round type Make: L&T / BCH / Havells /Any DJB approved make.
Supply of microprocessor based APFC relay 8 steps with all required accessories and digital display of power factor and other parameters. Make: L&T / BCH / Havells /Any DJB approved make.
Supply of triple pole contactor 25 amp complete with other accessories Make: L&T / BCH / Havells / HPL /Any DJB approved make.
Fixing of all above components in the APFC panel. The control wiring of the panel will be done with PVC flexible copper wire. Each wire will be terminating with a ferule crimped to the wire as required at site
Testing & commissioning of APFC panel with meggering of complete capacitors continuity tests cleaning of all points & joints etc. as required
Supply of flat LT power copper flexible cable, 35 sqmm 3 core, fire performance category FR-LSH. ISI Mark Make:- Polycab/Grandey/Any DJB approved make
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required details of cost for one Set DSR-2022 Code-5.4
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meterbelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm) (Payment done as per Actual) DSR E&M 2022 item no. 5.9
stage.html
html • 0.04 MB
technical_377184.pdf
techsummary_377184.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
BOQ_377184.xls
BOQ • 0.28 MB
NIT.pdf
Tender Documents • 0.86 MB
Download all tender documents and submit your bid