Loading…
Loading…
Tender Value
₹1.9 Cr
EMD Value
₹2.5 L
Closing Date
5 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECT BAHL
15 conditions · 4 needing a document upload
Interms of clause 1.1.12.2((ii) of the tender document, the tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where: V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared / audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-15 (Annexure-VIB), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant / Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
In terms of clause 1.1.12.2 of the tender document, the tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
The similar work is defined as under: "Design, supply, erection testing & commissioning of 50 Hz, single phase 25 kV AC OHE". (Ref: OHE Works S.No.1.1 of Pr. CEE/NR's Letter No. 181-Elect/TRD/189/Pt.II, dated 29.07.2021)
ELECTRICAL CONTRACTOR'S LICENSE: The tenderers must submit attested copy of valid Class-A Electrical contractor license along with his offer. Offer shall be summarily rejected if tenderer does not have Electrical contractor license issued by State / Central government.
26 conditions · 11 needing a document upload
Requisite earnest money, (ON ONLINE mode (No Documentary Proof required))
Cost of tender document
Requisite earnest money ,(ONLINE mode )
(ii) In case tenderer is other than sole proprietorship firm, following documents shall be submitted by the tenderer:
(a) Partnership Firm: The tenderer shall submit (i) a copy of Partnership Deed and (ii) a copy of Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm.
(b) Joint Venture (JV): The tenderer shall submit documents as mentioned in Clause 17 of the Tender Form (Second Sheet).
(c) Company registered under Companies Act-2013: The tenderer shall submit (i) the copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company; and (ii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.
(d) LLP (Limited Liability Partnership) Firm: If the tender is submitted on behalf of a LLP Firm registered under LLP Act-2008, the tenderer shall submit alongwith the tender- (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii)a copy of Power of Attorney/Authorisation issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm.
(e) Registered Society & Registered Trust: The tenderer shall submit (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust.
(iii) If it is NOT mentioned in the submitted tender that tender is being submitted on behalf of a Sole Proprietorship firm / Partnership firm / Joint Venture / Registered Company etc., then the tender shall be treated as having been submitted by the individual who has signed the tender.
(iv) After opening of the tender, any document pertaining to the constitution of Sole Proprietorship Firm / Partnership Firm / Registered Company/ Registered Trust / Registered Society etc. shall be neither asked nor considered, if submitted.
(v) A tender from JV / Partnership firm etc. shall be considered only where permissible as per the tender conditions.
(vi) The Railway will not be bound by any change in the composition of the firm made subsequent to the submission of tender. Railway may, however, recognize such power of attorney and changes after obtaining proper legal advice, the cost of which will be chargeable to the Contractor.
16. Employment/Partnership etc. of Retired Railway Employees: (a) Should a tenderer be a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, whether in the executive or administrative capacity or whether holding a pensionable post or not, in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, or should a tenderer being partnership firm / company / joint venture (JV) / registered society / registered trust etc have as one of its partners a retired Engineer or retired gazetted officer as aforesaid, or should a tenderer being an incorporated company have any such retired Engineer or retired officer as one of its directors or should a tenderer have in his employment any retired Engineer or retired gazetted officer as aforesaid, the full information as to the date of retirement of such Engineer or gazetted officer from the said service and in case where such Engineer or officer had not retired from government service at least 1 year prior to the date of submission of the tender as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, or to take the employment under the Contractor, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender. Tenders without the information above referred to or a statement to the effect that no such retired Engineer or retired gazetted officer is so associated with the tenderer, as the case may be, shall be rejected.
(b) Should a tenderer or Contractor being an individual on the list of approved Contractors, have a relative(s) or in the case of partnership firm/ company / joint venture (jv) / registered society / registered trust etc. one or more of his shareholder(s) or a relative(s) of the shareholder(s) employed in gazetted capacity in the Engineering or any other department of the _____________ railway, the authority inviting tenders shall be informed of the fact at the time of submission of tender, failing which the tender may be disqualified/rejected or if such fact subsequently comes to light, the contract may be rescinded in accordance with provision in clause 62 of standard general conditions of contract.
PAN CERTIFICATE : PAN The tenderer shall submit the photocopy of Permanent Account Number (PAN) issued by Income Tax authority attested by Gazetted officer / self attested.
GSTIN number: Bidder shall submit the photocopy of GSTIN number
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions. Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Payment of Earnest money Deposit (EMD) and Tender Document Cost (TDC) in respect of E- tendering will only be accepted through Net-Banking and payment Gateway only. No other mode of payment except this will be accepted and any offer without the same will be treated as invalid. Details of bank account no. and technical details have been provided for in the software (IREPS) to which prospective registered tenderers will have access at the time of tendering.
However, For service contracts, MSMEs registered with District Industries Centres, Khadi and Village Industries Commission, Khadi and Village Industries Board, Coir Board, National Small Industries Corporation, Directorate of Handicraft and Handloom, Any other body specified by Ministry of MSME, shall be supplied such tender document free of cost on confirmation (Xerox Copy) of their evidence to this effect
Tenderers are required to upload PAN Certificate, GSTIN Certificate as well as Certificates as per Annexure-9, Annexure- 10, Annexure-11, Annexure-12, Annexure-13, Annexure-14, Annexure-15, Annexure-16, Annexure-18, Annexure-19, Annexure-19A, Annexure-20 & Annexure-21.
(iii) If it is NOT mentioned in the submitted tender that tender is being submitted on behalf of a Sole Proprietorship firm / Partnership firm / Joint Venture / Registered Company etc., then the tender shall be treated as having been submitted by the individual who has signed the tender.
(iv) After opening of the tender, any document pertaining to the constitution of Sole Proprietorship Firm / Partnership Firm / Registered Company/ Registered Trust / Registered Society etc. shall be neither asked nor considered, if submitted.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Design, supply, erection, testing & commissioning of 25 KV OHE work in connection with provision of new lines at Sopore station & provision of new loop line at Baramulla station on BAHL- BRML section over Jammu division.
17-E-C-TRD-SXZM-2025~NR
17-E-C-TRD-SXZM-2025
Open
Works - General
12 Months
Ramban, Jammu And Kashmir
₹0
₹2.5 L
5 Jan 2026
27 Nov 2025
8 Dec 2025
331 items across 9 schedules · ₹1,91,59,012.84 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Preparation of drawing as per RDSO design for Over Head Equipment | Per Track KM | 1.20 | 11,347.3 | 13,616.76 |
| 2 | Supply of Concrete for foundation and plinth in other than hard & rocky soil | cum | 85.00 | 6,739.54 | 5,72,860.9 |
| 3 | Erection of Concrete for foundation and plinth in other than hard & rocky soil | cum | 85.00 | 1,652.95 | 1,40,500.75 |
| 4 | Supply of galvanized steel fabricated masts / other supporting structure | MT | 18.00 | 1,33,140.05 | 23,96,520.9 |
| 5 | Erection of galvanized steel fabricated masts / other supporting structure | MT | 18.00 | 9,841.96 | 1,77,155.28 |
| 6 | Supply of fabricated and galvanized steel work (SPS) other than mast with necessary components | MT | 2.00 | 1,36,183.45 | 2,72,366.9 |
| 7 | Erection of fabricated and galvanized steel work (SPS) other than mast with necessary components | MT | 2.00 | 9,062.7 | 18,125.4 |
| 8 | Supply of Single bracket assembly (without insulator) | Numbers | 35.00 | 21,636.61 | 7,57,281.35 |
| 9 | Erection of Single bracket assembly | Numbers | 35.00 | 2,111.39 | 73,898.65 |
| 10 | Supply of Stay Arm composite insulator CD 1600 mm as per RDSO Spec. No. TI/SPC/OHE/INSCOM/1072 or latest. | Numbers | 35.00 | 1,701.82 | 59,563.7 |
| 11 | Supply of Bracket Composite Insulators CD 1600 mm as per RDSO. Spec. No. TI/SPC/OHE/INSCOM/1071(Rev-01) or latest. | Numbers | 35.00 | 1,807.23 | 63,253.05 |
| 12 | Erection of insulators for single bracket assembly | Set | 35.00 | 1,390.8 | 48,678 |
| 13 | Supply of OHE with complete fitting (For Conventional type) without Contact & Catenary Wires as per explanatory Notes | Per Track KM | 1.20 | 28,419.37 | 34,103.24 |
| 14 | Erection of OHE with complete fitting (For Conventional type) without Contact & Catenary Wires as per explanatory Notes | Per Track KM | 1.20 | 28,404.66 | 34,085.59 |
| 15 | Supply of copper jumper wire | Numbers | 6.00 | 7,457.92 | 44,747.52 |
| 16 | Erection of copper jumper wire | Numbers | 6.00 | 731.88 | 4,391.28 |
| 17 | Supply of Guy Rod Assembly | Numbers | 4.00 | 10,432.99 | 41,731.96 |
| 18 | Erection of Guy Rod Assembly | Numbers | 4.00 | 1,226.2 | 4,904.8 |
| 19 | Supply of Composite 9T Insulators (CD 1600mm) as per RDSO Specification TI/SPC/OHE/INSCOM/1070 (Rev-1) or latest. | Numbers | 12.00 | 2,072.37 | 24,868.44 |
| 20 | Erection of 9-Tonne insulator | Numbers | 12.00 | 1,406.26 | 16,875.12 |
| 21 | Supply of 9 tonne suspension insulator assembly including all accessories | Numbers | 8.00 | 5,015.42 | 40,123.36 |
| 22 | Erection of 9 tonne suspension insulator assembly including all accessories | Numbers | 8.00 | 1,000.2 | 8,001.6 |
| 23 | Supply of regulating equipment 3 pulley type ATD with counter weight | Numbers | 4.00 | 72,740.08 | 2,90,960.32 |
| 24 | Erection of regulating equipment 3 pulley type ATD with counter weight | Numbers | 4.00 | 4,222.79 | 16,891.16 |
| 25 | Supply of Section Insulator assembly including bar insulator assembly for conventional OHE | Numbers | 5.00 | 54,983.62 | 2,74,918.1 |
| 26 | Erection of Section Insulator assembly including bar insulator for conventional OHE | Numbers | 5.00 | 3,366.41 | 16,832.05 |
| 27 | Supply (without insulator) of 25KV Single Pole(SP) Isolator without earth contact assembly | Numbers | 2.00 | 51,738.44 | 1,03,476.88 |
| 28 | Erection of 25KV Single Pole(SP) Isolator without earth contact assembly | Numbers | 2.00 | 4,510.18 | 9,020.36 |
| 29 | Supply of 25KV post / pedestal insulators for isolators | Numbers | 8.00 | 8,953.89 | 71,631.12 |
| 30 | Erection of 25KV post / pedestal insulators for isolators | Numbers | 8.00 | 383.1 | 3,064.8 |
| 31 | Supply of an Earth contact assembly in an isolator | Numbers | 2.00 | 7,985.94 | 15,971.88 |
| 32 | Erection of an Earth contact assembly in an isolator | Numbers | 2.00 | 1,117.49 | 2,234.98 |
| 33 | Supply & erection of post and operating rod insulator | Numbers | 4.00 | 20,112.5 | 80,450 |
| 34 | Supply of copper bus bar 18mm | Metre | 30.00 | 1,390.33 | 41,709.9 |
| 35 | Erection of copper bus bar 18mm | Metre | 30.00 | 122.93 | 3,687.9 |
| 36 | Supply of single earth electrode with earth pit complete as per RDSO Drg No. ETI / OHE / P / 7020 or latest | Numbers | 10.00 | 4,137.27 | 41,372.7 |
| 37 | Erection of single earth electrode with earth pit complete as per RDSO Drg No. ETI / OHE / P / 7020 or latest | Numbers | 10.00 | 1,343.47 | 13,434.7 |
| 38 | Manufacturing supply of Retro Reflective type structure Number plate as per RDSO drg. No.ETI / OHE / P / 7503 or latest along with all fixing arrangement. | Numbers | 35.00 | 676.28 | 23,669.8 |
| 39 | Erection / Fixing of Retro Reflective type structure Number plate as per RDSO drg. No.ETI / OHE / P / 7503 or latest along with all fixing arrangement. | Numbers | 35.00 | 85.13 | 2,979.55 |
| 40 | Supply of material without insulators for termination of OHE conductor | Numbers | 4.00 | 7,226.18 | 28,904.72 |
| 41 | Erection of material for termination of OHE conductor | Numbers | 4.00 | 1,018.06 | 4,072.24 |
| 42 | Supply of splicing and extension of anchored over head equipment with components | Numbers | 4.00 | 6,310.36 | 25,241.44 |
| 43 | Erection of splicing and extension of anchored over head equipment with components | Numbers | 4.00 | 5,676.3 | 22,705.2 |
| 44 | Supply of Structure Bonds | Numbers | 35.00 | 896.08 | 31,362.8 |
| 45 | Erection of Structure Bonds | Numbers | 35.00 | 221.8 | 7,763 |
| 46 | Supply of Transverse (cross rail, inter-track, Z & special type) bonds | Numbers | 12.00 | 1,050.94 | 12,611.28 |
| 47 | Erection of Transverse (cross rail, inter-track, Z & special type) bonds | Numbers | 12.00 | 151.73 | 1,820.76 |
| 48 | Supply of Longitudinal bonds | Numbers | 12.00 | 667.99 | 8,015.88 |
| 49 | Erection of Longitudinal bonds | Numbers | 12.00 | 141.79 | 1,701.48 |
| 50 | Supply of earth bus | Metre | 40.00 | 228.06 | 9,122.4 |
| 51 | Erection of earth bus | Metre | 40.00 | 80.37 | 3,214.8 |
| 52 | Erection of bonds on platform area including drilling of holes in structure and rail including cutting of platform surface100mm x 500mm placing of bond and making good surface with PCC and providing cleats as per latest RDSO drawing | Numbers | 14.00 | 2,839.56 | 39,753.84 |
| 53 | Supply and fixing of cleat 02 Nos. for each structure Bond on platform wall with screw | Numbers | 14.00 | 98.37 | 1,377.18 |
| 54 | Platform cutting and covering with concrete according to Bond size | Numbers | 14.00 | 351.33 | 4,918.62 |
| 55 | Inspection, removal of existing Bonds, providing chamfering, refixing of existing bonds, painting where necessary of existing Bonds at designated locations | Per Track KM | 0.25 | 37,372.44 | 9,343.11 |
| 56 | Erection of Contact Wire only after dismentling of Catenary wire under FOB (Overline structure) | Kilometre | 0.25 | 17,728.36 | 4,432.09 |
| 57 | Supply for Reprofiling of existing OHE: (i) To maintain vertical gap between mail line & turn out contact wire between 50 to 60 mm at obligatory mast. (ii) To maintain 50 mm gap, 5m distance from obligatory mast. (iii) To maintain 40 to 50 mm gap, 10m distance from obligatory mast. (iv) To change presag from 100 mm to 50 mm. (v) Reduction of gradient from 3mm/m to 2mm/m & relative gradient from 1.5 mm/m to 1 mm/m. | Kilometre | 0.50 | 1,02,326.58 | 51,163.29 |
| 58 | Erection for Reprofiling of existing OHE: (i) To maintain vertical gap between mail line & turn out contact wire between 50 to 60 mm at obligatory mast. (ii) To maintain 50 mm gap, 5m distance from obligatory mast. (iii) To maintain 40 to 50 mm gap, 10 m distance from obligatory mast. (iv) To change presag from 100mm to 50 mm. (v) Reduction of gradient from 3mm/m to 2mm/m & relative gradient from 1.5 mm/m to 1 mm/m. | Kilometre | 0.50 | 19,760.46 | 9,880.23 |
| 59 | Supply of Contact wire Ending Clamp | Numbers | 16.00 | 400.31 | 6,404.96 |
| 60 | Supply of Catenary wire Ending Clamp | Numbers | 16.00 | 677 | 10,832 |
| 61 | Supply of electrolytic Copper Hard drawn Dropper wire 5mm dia | Kg | 7.00 | 1,063.13 | 7,441.91 |
| 62 | Erection of electrolytic Copper Hard drawn Dropper wire 5mm dia | Kg | 7.00 | 158.95 | 1,112.65 |
| 63 | Dismentling of OHE termination assembly | Numbers | 4.00 | 1,492.22 | 5,968.88 |
| 64 | Dismentling & removal of Anchor assembly | Numbers | 4.00 | 1,161.49 | 4,645.96 |
| 65 | Supply of Anti-Creep with componenet | Numbers | 4.00 | 40,484.92 | 1,61,939.68 |
| 66 | Erection of Anticreep with component | Numbers | 4.00 | 3,406.34 | 13,625.36 |
| 67 | Dismantling of Bracket Assembly | Numbers | 12.00 | 1,625.79 | 19,509.48 |
| 68 | Reclaimation of OHE mast | Numbers | 6.00 | 4,455.12 | 26,730.72 |
| 69 | Cutting and removal of existing structure | Numbers | 6.00 | 1,123.3 | 6,739.8 |
| 70 | Dismantling of Guy Rod Assembly | Numbers | 4.00 | 769.19 | 3,076.76 |
| 71 | Dismantling of fabricated steel other than mast | MT | 2.00 | 15,795.77 | 31,591.54 |
| 72 | Dismantling of copper jumper | Numbers | 4.00 | 682.52 | 2,730.08 |
| 73 | Shifting of ATD / BWA from one mast to another | Each Span | 8.00 | 4,165.64 | 33,325.12 |
| 74 | Raising / Restoration of OHE height as per OHE profile by Change of incumbrance / Re- droppering of span | Each Span | 15.00 | 1,909.29 | 28,639.35 |
| 75 | Adjustment of Turnout or insulated / un- insulated overlap | Numbers | 4.00 | 1,873.45 | 7,493.8 |
| 76 | Dismantling of Three Puley type ATD & termination | Numbers | 4.00 | 4,217.54 | 16,870.16 |
| 77 | Dismantling of section insulator assembly | Numbers | 2.00 | 3,510.91 | 7,021.82 |
| 78 | Dismantling of 9-Tonne insulator | Numbers | 8.00 | 748.88 | 5,991.04 |
| 79 | Dismantling of Pedestal insulator | Numbers | 8.00 | 667.97 | 5,343.76 |
| 80 | Dismentling of an Isolator | Numbers | 2.00 | 2,386.01 | 4,772.02 |
| 81 | Dismentling of Anticreep | Numbers | 4.00 | 2,242 | 8,968 |
| 82 | Slewing of OHE (including Restoration of OHE) | Each Span | 10.00 | 1,676.46 | 16,764.6 |
| 83 | Transfer of equipment from one support to another | Numbers | 2.00 | 3,468.59 | 6,937.18 |
| 84 | Supply of Large Copper Jumper wire 160 Sqmm | Metre | 50.00 | 2,195.88 | 1,09,794 |
| 85 | Erection of Large Copper Jumper wire 160 Sqmm | Metre | 50.00 | 393.36 | 19,668 |
| 86 | Supply of Large Span Wire (130 Sq mm) | Metre | 100.00 | 982.78 | 98,278 |
| 87 | Erection of Large Span Wire (130 Sq mm) | Metre | 100.00 | 158.36 | 15,836 |
| 88 | Supply of Large Span Ending (130 Sq mm) | Numbers | 4.00 | 833.51 | 3,334.04 |
| 89 | Erection of Large Span Ending (130 Sq mm) | Numbers | 4.00 | 79.95 | 319.8 |
| 90 | Supply of 150sq mm hard drawn copper cross feeder with component | Kilometre | 0.25 | 12,49,517 | 3,12,379.25 |
| 91 | Erection of 150sq mm hard drawn copper cross feeder with component | Kilometre | 0.25 | 8,206.79 | 2,051.7 |
| 92 | Preparation of computerized OHE Layout Plan (LOP) for station Yards | Per Track KM | 1.20 | 5,281.36 | 6,337.63 |
| 93 | Fabrication, developing and supply of fabricated Sectioning Diagram, Schematic and TSWR diagram Boards with computerized digital printing on adhesive Venyle of adequate size as per requirement | Square Foot | 40.00 | 1,955.08 | 78,203.2 |
| 94 | Re-painting on existing OHE structures with water proof yellow enameled paint as per explanatory notes(Rate included material & erection) | Sqm | 50.00 | 23.32 | 1,166 |
| 95 | Re-writing on existing OHE structures as per explanatory notes(Rate included material & erection). | Sqm | 50.00 | 418.01 | 20,900.5 |
| 96 | Supply and erection of "Electric Engine Stop" Board size 900x600x 2mm with supply of fixing material (Clamp, back flat strip & fasteners) | Numbers | 6.00 | 4,141.35 | 24,848.1 |
| 97 | Supply and erection of "Caution unwire turnout" Board size 900x600x 2mm with supply of fixing material (Clamp, back flat strip & fasteners) | Numbers | 6.00 | 2,802.13 | 16,812.78 |
| 98 | Supply and erection of "Caution live wire" Board size 400x270x 2mm with supply of fixing material (Clamp, back flat strip & fasteners) | Numbers | 6.00 | 2,442.52 | 14,655.12 |
| 99 | Supply and erection of "Caution clearance to OHE nearby restricted" Board size 450x270x 2mm with supply of fixing material (Clamp, back flat strip & fasteners) | Numbers | 6.00 | 1,353.31 | 8,119.86 |
| 100 | Supply and erection of "Power Block Working Limit" Board size 450x450x2mm with supply of fixing material (Clamp, back flat strip & fasteners) | Numbers | 6.00 | 1,526.74 | 9,160.44 |
| 101 | Supply and erection of "Protective Area" Board size 12"x18" with supply of fixing material (Clamp, back flat strip & fasteners) | Numbers | 6.00 | 2,787.28 | 16,723.68 |
| 102 | Manufacturing, Supply & erection of Engine Stop Board of size 600 x 900 mm made of 2 mm thk. Aluminium alloy sheet | Numbers | 6.00 | 2,284.3 | 13,705.8 |
| 103 | Supply of various types 25KV caution Board / Plates as per explanatory Notes | Numbers | 8.00 | 374.27 | 2,994.16 |
| 104 | Erection of various types 25KV caution Boards / plates as per explanatory Notes | Numbers | 8.00 | 89.02 | 712.16 |
| 105 | Supply of various types of 25KV Danger Boards / plates as per explanatory notes | Numbers | 8.00 | 504.69 | 4,037.52 |
| 106 | Erection of various types of 25KV Danger Boards / plates as per explanatory notes | Numbers | 8.00 | 64.13 | 513.04 |
| 107 | Design, manufacturing, supply of Retro Reflective type Sigma Board with non- reflective black ground as per RDSO drg. No. TI/Drg/OHE/PLTBRD/RDSO/ 00036/12/0 (Size 450 mm x 600 mm) and RDSO specification No. ETI/OHE/33A (12/97) Rev. 8 or latest including transportation and all taxes etc. | Numbers | 4.00 | 1,809.36 | 7,237.44 |
| 108 | Cost of 4 Nos. 12mm dia GI nuts & bolts 300 mm long (fully threaded) with necessary washer, spring washer for different OHE Mast / Portals etc including transportation and all taxes | Set | 10.00 | 248.61 | 2,486.1 |
| 109 | Cost of GI backing angle for mounting arrangement size 40x40x5x450mm (4 Nos.) including transportation and all taxes | Set | 10.00 | 425.37 | 4,253.7 |
| 110 | Erection of clamps-GI backing angle for arrangement size 40x40x5x450mm (4 Nos.) 12mm dia GI nuts & bolts 300 mm long (fully threaded) with necessary washer, spring washer including Retro Reflective type sigma board with non reflective back ground at different OHE Mast / Portals etc including transportation and all taxes | Set | 10.00 | 315.12 | 3,151.2 |
| 111 | Interlocking system for isolator make interprosing consisting: a) Bolt lock type L insertion A-01; b) Lock with key exchange box with key incription B & A | Set | 2.00 | 13,888.45 | 27,776.9 |
| 112 | Labour charges for fitting of interlocking system | Set | 2.00 | 1,084.35 | 2,168.7 |
| 113 | Supply of Anti-Bird Disc as per drawing No. TI/DRG/OHE/Anti- Bird/00001/00/01 (Sh-1 & Sh- 2) or latest | Numbers | 50.00 | 644.95 | 32,247.5 |
| 114 | Breaking of all type of Foundations of mast / Portal / TTC etc | Numbers | 10.00 | 3,851.8 | 38,518 |
| 115 | Handling, Leading, loading and Transportation charges for Railway supply material from different Railway sites and released material from different Railway sites, if any to concerned TRD Depot | MT | 3.00 | 2,780.61 | 8,341.83 |
| 116 | supply of shock treatment chart | Numbers | 2.00 | 1,795.23 | 3,590.46 |
| 117 | Erection of shock treatment chart | Numbers | 2.00 | 364.4 | 728.8 |
| 118 | Supply of Fire buckets | Numbers | 4.00 | 727.95 | 2,911.8 |
| 119 | Supply of Fire extinguisher | Numbers | 4.00 | 3,639.79 | 14,559.16 |
| Schedule total | ₹75,10,364.11 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .