| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance HAPPY HOME FRIENDS COLONY RAMGARH CANTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | JHARKHAND | 829122 | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | HI TECH COLONISERS PRIVATE LIMITED L3 | M/s united construction co. L1 | M/S DEEPAK KUMAR SINHA L2 |
|---|---|---|---|---|---|---|
| 1.00SCHEDULE "A" | ||||||
| 2.00 | SCHEDULE "A" PART-I (Building Work)
Lump sum price worked out by the contractor for 'Building Work' as listed in Schedule 'A' Part-I A against the lump sum price inserted by the MES. | 1 | Lump sum | 82,90,377 ₹82.9 L | 77,02,870.08 ₹77.0 L | 79,47,664.68 ₹79.5 L |
| 3.00 | Sch 'A' Part-II (Internal electrification) Lump sum price worked out by the contractor for (Internal electrification) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. | 1 | Lump sum | 6,12,350 ₹6.1 L | 5,14,952.98 ₹5.1 L | 5,42,436.43 ₹5.4 L |
| 4.00 | Sch 'A' Part-III (Internal water supply) Lump sum price worked out by the contractor for (Internal electrification) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. | 1 | Lump sum | 1,20,003 ₹1.2 L | 1,11,114.01 ₹1.1 L | 1,13,780.74 ₹1.1 L |
| 5.00 | Sch 'A' Part-IV (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. | 1 | Lump sum | 3,94,516 ₹3.9 L | 3,26,174.8 ₹3.3 L | 3,35,494.08 ₹3.4 L |
| 6.00 | Sch 'A' Part-V (External Water supply) Lump sum price worked out by the contractor for 'External Water supply' as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. | 1 | Lump sum | 32,695 ₹32,695 | 31,387.14 ₹31,387.14 | 32,694.93 ₹32,694.93 |
| 7.00 | Sch 'A' Part-VI (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. | 1 | Lump sum | 3,31,680 ₹3.3 L | 2,59,899 ₹2.6 L | 2,92,076.97 ₹2.9 L |
| 8.00 | Sch 'A' Part-VII (Hard Standing) Lump sum price worked out by the contractor for (Hard Standing) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. | 1 | Lump sum | 6,93,707 ₹6.9 L | 5,86,590.47 ₹5.9 L | 6,06,993.61 ₹6.1 L |
| 9.00 | Sch 'A' Part-VIII (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. | 1 | Lump sum | 3,50,855 ₹3.5 L | 2,65,721.14 ₹2.7 L | 2,78,620.22 ₹2.8 L |
| 10.00 | Sch 'A' Part-IX (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. | 1 | Lump sum | 2,14,953 ₹2.1 L | 1,78,576.7 ₹1.8 L | 1,85,190.65 ₹1.9 L |
Updated dates
Tender Value
₹95.5 L
EMD Value
₹1.7 L
Closing Date
28 Feb 2026, 6:00 pmClosed
Chief Engineer Jabalpur Zone
HQ Chief Engineer Jabalpur Zone Ridge Road Jabalpur Cantt 482001
CONSTRUCTION OF 04 OR DUS AT DANAPUR CANTT AGAINST TFR TO DEF LAND FOR CON STRUCTION OF DANAUR TO KHEMNI CHAK CORRIDOR TO PATNA METRO RAIL CORPORATION
2025_MES_723034_2
752983A CONSTRUCTION OF 04 OR DUS AT DANAPUR CANTT AGAINST TFR TO DEF LAND FOR CONSTRUCTION DANAPUR
Open Tender
Civil Works
365 days
DANAPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE DANAPUR
₹1.7 L
Yes
13 Mar 2026
12 Jan 2026
7 Mar 2026
12 Jan 2026
28 Feb 2026
26 Jan 2026
SCHEDULE "A" PART-I (Building Work) Lump sum price worked out by the contractor for 'Building Work' as listed in Schedule 'A' Part-I A against the lump sum price inserted by the MES.
Sch 'A' Part-II (Internal electrification) Lump sum price worked out by the contractor for (Internal electrification) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES.
Sch 'A' Part-III (Internal water supply) Lump sum price worked out by the contractor for (Internal electrification) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES.
Sch 'A' Part-IV (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES.
Sch 'A' Part-V (External Water supply) Lump sum price worked out by the contractor for 'External Water supply' as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES.
Sch 'A' Part-VI (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES.
Sch 'A' Part-VII (Hard Standing) Lump sum price worked out by the contractor for (Hard Standing) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES.
Sch 'A' Part-VIII (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES.
Sch 'A' Part-IX (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES.
SCHEDULE "A" PART-X (Scooter and Garages) Lump sum price worked out by the contractor for (Scooter and Garages) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES.
Item No 01 : S & F modular type TV Socket out let complete all as specified and as directed.
Item No 02 : S & F modular type LAN Socket RJ 45 with complete box
Item No 03 :S& F of Rechargeable LED bulb E27 Cool Day light 9/10 watts having Luminous Efficacy range lies between ( ≥90 and <105 ) lm/W as per BEE guidelines, 4 Hours back up , Long Life 20000-25000 hours In-built surge protection of 3 kV Warranty of 2 Year complete all as specified and as directed.
Item No 04 : Supply and fixing pole mounted SMC junction box/bus bar chamber for loop IN/OUT connection of street light cable of size 295x195x100 mm high heat distoration temperature, non-fusing, shock proof, rustproof, 100% weatherproof, fire retardant- class FV-O as per IS 11731 Part-Il and suitable locking arragement with 63 amps aluminium busbar wrapped with PVC sleeves and maintained the colour code and provision of making holes with Gl nuts, bolts & washers for connections and mounted on hydrograpic insulators with nuts & bolts at both ends of busbar and suitable arrangement for fixing one no MCB complete all as specified and as directed.
Item No 05 : Supply and fixing for security wall light bracket made out of Gl pipe light grade suitable for street light fittings as per required dia & length bent to shape by cutting, welding and well finishing excluding MS clamp complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats of aluminium paints over a coat of red oxide primer complete all as specified and as directed. (Note: MS clamp shall be measured and paid separately under relevant items of this Sxhedule 'A')
Item No 06 : Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised Iron 4.00 mm earth lead by means of nuts bolts check nuts Gl washers earth wire protected by galvanised iron pipe 15mm bore (Medium grade) for poles/panel including connecting to pole all as directed including concrete pit in PCC (1:3:6) type Cl, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR Part I including testing on completion all as specified and directed.
Please Enable Macros to View BoQ information
Schedule 'A' Part-I
(Building works)
Construction of Married Accn for 04 ORs (G+1) with permanent specification, RCC framed Structure in RCC M 25 Grade concrete with APP Roof treatment, ATT treatment complete all as specified & shown on drawings.
Total Amount
Signature of Contactor
Schedule 'A' Part II
(Internal Electrification)
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with mudular metal box min 1.2mm thick, duly covered with modular white colour plate with frame and other necessary accessories ncluding PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One light point controlled by one, two way switch 5 Amps
(d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(f) One bell point controlled by one, bell switch 5 Amps
Description all as per item No 1 here in before but using 2.5 sq mm single core copper conductor two nos cables of multistranded flame retardant FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete.
S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified.
S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F Bell push modular 6 Amps single module complete all as specified.
S & F Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCB DB TPN 4 way Horizontal type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Note :- Rates includes with dummy plates as per requirement.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB four pole rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB DP rated capacity 25 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. 6A -13 Nos, 10A-8 Nos, 16A-4 Nos, 32A- 4Nos,
Supply and fixing ceiling fans complete with blades, down rods, with remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of suitable size from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed.
S&F Exhaust fan made of sturdy engineering plastic complete with louvers shutter, 230 V, 50 Hz, 1200 RPM , copper winding fan single phase 250 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed by Engineer in charge
S & F for Angular Holder wall mounted made out of PVC/ Policarbonate back plate and bipin holder made of brass to be fitted for LED bulb complete all as specified and directed.
S & F for LED 10 watts batten aluminium extruded with decorative end caps luminous efficacy not less than 120 lumen/watt complete with warranty option of 2 years (20000-25000 Hrs) from date of installation, LED Driver,Chip and housing should be of same Make all as specified and as directed. Make - Philips /Osram/GE
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting,luminous efficacy not less than 120 lumen/watt 230 volts and intregrated electronic driver connector block etc with warranty option of 2 years (20000-25000 Hrs) from date of installation, LED Driver,Chip and housing should be of same Make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make - Philips /Osram/GE
S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts , luminous efficacy not less than 110 lumen/watt with with warranty option of 2 years (20000-25000 Hrs) from date of installation, LED Driver,Chip and housing should be of same Make pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make - Philips /Osram/GE
Supply, installation, testing & commissioning of single Phase, 2 Wire, AC Static Direct connected, Smart Prepaid Energy Meters, BIS-16444 : 2015(Reaffirmed 2020) marked, current range 10-60 Amp, 240 V, accuracy class 1.0, UC1 category having post paid and prepaid feature complete all as specified and directed.
S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed.
M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and 15 mm dia GI pipe for protection of GI wire up to 7.5 mtr connected to earthing point complete all as specified and as directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated, auto power save system, auto trip after water heat at desired level complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part III
(Internal Water Supply)
Galvanized steel water tubing medium grade with & including all fittings (ISI marked) 15 mm bore fixed on concealed in walls, laid in floor, ceiling etc complete all as specified
Galvanized steel water tubing medium grade with & including all fittings (ISI marked) 20 mm bore fixed on concealed in walls, laid in floor, ceiling etc complete all as specified
Galvanized steel water tubing medium grade with & including all fittings (ISI marked) 25 mm bore fixed on concealed in walls, laid in floor, ceiling etc complete all as specified
S & F taps Cast Copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed down screwed for iron pipes or for brass ferrule of 15 mm bore complete all as specified and directed
Piller taps cast copper alloy, with capston head, chromium plated fancy type screwed down high pressure with or without lettered HOT or Cold with long screwed shanks and fly nuts, screwed for iron pipr of 15 mm bore complete all as specified
S &F angle cock, stop valve cast copper alloy with crutch or butterfly handle,high pressure, screwed down screwed for iron pipes or for union of 15 mm bore complete all as specified and directed
S & F PVC Connection 15 m dia size with and 450 m long with 2 Nos check nut its washer complete all as specified and directed
Ball Valve high pressure of PTMT with epoxy coated Aluminium Rod and high density plastic ball screwed for 15 mm bore for iron pipr and fixed (Minimum wt 15 mm - 142 gms)
Supply and Fix gun metal globe or gate valve with iron wheel head, screwed both end for iron pipr/ for union of 25 mm bore, complete all as specified and directed
Galvanised steel water tubing medium grade with & including all fittings (ISI Marked) 40 mm bore fixed on concealed in walls, laid in floor, ceiling etc complete all as specified
Supply and fic gun metal globe or gate valve with iron head, screwed both end for iron pipe/ for union of 40 mm bore, complete all as specified and directed
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part IV
(External Electric Supply)
Supply and errect Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) Swan Neck type including PCC foundation & coping etc and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing LED light fitting for street/security lighting energy saving & environmental friendly long life versatile pressure die-cast housing with toughened glass and individual high power LED with secondary optics of capacity 75 Watt (nearest higher standard size) of lumen efficacy not less than 140 lm/watt 240 volts AC 50 Hz, IP 66 protection including electrical connection and five years on site warranty from manufacturer complete all as specified and directed.
Supply and Fix MCB SP 6-32 Amps C series for Street light including all fittings all as specified and as directed.
M&L for wiring with two runs of 1.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed copper conductor FRLS cable upto and including 1100 V grade drawn through PVC rigid conduit medium grade fixed to pole including one run of 1.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed copper conductor FRLS cable as earth wire and duly connected to common earth point all as specified and directed including taking out old cables. (Note:-(i) One run of PVC rigid conduit with all fittings/accessories and Two runs of 1.5 sqmm single core cable and one run of 1.5 sqmm earth continuity wire to be measured as one length).
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 25 sqmm 4 core complete all specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 16 sqmm 4 core complete all specified and directed.
Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil etc complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
M & L in repair for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed.
M & L in repair for Old size sub class 'B' bricks, laid in trenches as cable covers complete all as specified and directed.
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete.
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete.
Supply and fixing as of Gl tubing, Light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of earth conductor complete all as specified and as directed.
M & L for cross arms, bracing clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, drilling hole for bolts in any shape or size complete with welding, binding, two coats of aluminium paint over a coat of primer for fixing flood lights complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part V
(External Water supply)
Supply, fixing & laying only Gl tubing medium grade with one socket both end threaded in any length including cutting threading connection including Gl new fittings for laid in trenches/wall/ceiling/ floor all as specified and directed of following size :-
(a) 25 mm bore Gl pipe
(b) 20 mm bore Gl pipe
S & F Valve, stop, screwed, 15 mm with iron wheel head, screwed both ends for iron pipe and fixeding for following size:-
(a) 25 mm bore
(b) 20 mm bore
M & L for tapping/cutting from DI/GI pipe any diameter including suitable size Tee/ fittings for 25 mm dia GI pipe complete all as specified and as directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles, stay assembly and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VI
(Sewage Disposal)
Excavation in trenches in soft/ loose soil not exc 1.5m wide and not exc 1.5m deep for foundation, pier holes etc n. exc 10sqm on plan and getting
Returning filling in inclunding spreading levelling watering well raming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated material exc 50m but n exc 150m and depositing where directed at a level n exc 1.5m above the starting point.
M&L for concrete bed in PC.C. 1:4:8 type D2 (using 40mm graded stone aggregated) to drain pipes including packing under and haunching against the sides of the pipes after laying and testing for the following dia of pipes.
(a) 100 mm dia.
(b) 150 mm dia.
M & L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches complete all as specified and directed for the following internal dia of pipes.
(a) 100 mm dia.
(b) 150 mm dia
M&L for cutting salt-glazed stoneware drain pipe in position, including jointing socket end of new pipe to same with packed spun yarn and cement mortar 1:1, dia of pipe 150 mm complete all as specified and directed.
M & L for cutting salt-glazed stoneware drain pipe in position, including jointing socket end of new pipe to same with packed spun yarn and cement mortar 1:1, dia of pipe 200 mm complete all as specified and directed.
M & L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required dia of pipe 150 mm complete all as specified and directed.
M & L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required dia of pipe 200 mm complete all as specified and directed.
Total carried over to BOQ Rs.
SIGNATURE OF CONTRACTOR
DATED _________
Schedule 'A' Part VII
(Hard Standing)
Surface dressing n exc 15 cm deep and getting out in soft/loose soil all as spd.
M&L for removal of excavated soil to distance of exc 250m but n exc 500m and deposting at alevel n. exc 1.5m above the starting point
M & L 100 mm thick Hard core of gauge n.exc 63 mm deposited spread & levelled in layers n.exc 15 cm thick watered & rammed to a true surfaces broken stone or boulders all as spd and directed.
M&L for PCC 1:4:8 type using 40mm graded stone aggregate as in foundation filling.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engineer-in-Charge.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed by Engineer-in-Charge.
M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade Cum cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage onening wherever required complete.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VIII
(Area Drainage)
Excavation in trenches nexc 1.5m wide-curn and nexc 1.5m in depth for foundation and getting out in soft/loose soil all as specified and directed.
M&L for PCC 1:3:6 type C-2(using 40mm graded stone aggregates) as in bedding of drain etc all as specified and directed.
M&L for brick work with sub class 'B' bricks built in cement mortar 1:4 straight on plan using old size bricks all as specified and directed.
M&L for PCC 1:2:4 type B-0(using 12.5 mm graded stone aggregates) as in drain benching etc. surface finished even and fair all as specified and directed.
M&L for PCC 1:2:4 type B-1(using 20mm graded stone aggregates) as in coping of drains including necessary formwork etc all as specified and directed.
M&L for 15mm thick cement plaster on brick surfaces of drian in cement mortar 1:4 surface finished even and smooth without using extra cement all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc all as specified and directed.
Returning, filling in including watering and well ramming in layers nexc 25cm thick all as specified and directed.
Removal of surplus soil to a distance nexc 50m and depositing where directed at a level nexc 1.5m above starting point all as specified and directed.
M&L for MS TMT bar 10 dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.90mm dia or securing with clips complete all as specified and as directed.
M&L for pre-cast RCC slabs as in manhole covers in 1:2:4 type B1 using 20 mm graded stone aggregates, set in cement mortar (1:4) incl use and waste of form work complete all as speciied and as directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part IX
(Site Clearance)
Surface dressing n exc 15 cm deep and getting out in soft/loose soil all as spd.
M&L for Moorum filling in floors or pavings, laid in layers n exc 15cm thick in each layer, spread, levelled and rammed by 8 to 12 ton mechanical power roller including watering, transporting and depositing etc from approx 80 to 100 Km complete all as specified and directed by Engr-in-Charge.
M&L for removing excavated material exc 250m but n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part-X
(Scooter and Garages)
Surface dressing n exc 15 cm deep in soft loose soil complete all as specified and as directed.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation etc and getting out in soft/loose soil.
Excavation in trenches, n exc 1.5m wide and exc 1.5m in depth, for foundation etc and getting out in soft/loose soil.
M&L PCC 1:4:8 type-D2 (40mm graded aggregate) as in foundations, filling and mass concrete.sub base as in floors.
M&L PCC 1:5:10 type-D2 (40mm graded aggregate) as in foundations, filling and mass concrete.sub base as in floors.
M&L 100mm thick PCC 1:3:6 type-D2 (40mm graded aggregate) as floor complete all as specifed and directed.
Returning Filling in,including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft/loose soil..
Removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point.
M&L for hard core of gauge n.exc 63 mm deposited, spread and levelled in layers n.exc 15 cm thick with broken bricks, watered and rammed to a true surface complete all as specified.
M&L Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:6
M&L reinforced cement concrete (M-25 Design mix) (using 20 mm graded stone aggregate) in foundation, footing, foundation beams, plinth beams, bases for columns, pedestal, under reamed piles, mass concrete, etc complete.
M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in columns, pillars, posts, struts etc complete.
M&L RCC type B1, 1:2:4 (20mm graded aggregate) as in beams, cantilevers, bressmummers, lintels over 1.5 m span, seismic bands etc complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete.
M&L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished , square, rectangular or polygonal surfaces of concrete
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed.
S&F Mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopinbg for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips all as specified
Ditto all as per item No above but 6mm dia and over upto and including 10 mm dia in stirrups, spacers and binders
M&L 15 mm thick rendering in two layers (10mm & 5mm ) on fair faces of bk / concrete surfaces in cm (1:4) with WPC (WPC measured & paid separetely) finished even and smooth (Without using extra cement ) complete.
M&L 15 mm thick rendering on fair faces of bk /concrete surfaces in cm (1:6), finished even and smooth (Without using extra cement ) complete
Supply only water proofing compound (liquid), ISI marked.
S & F for rolled mild steel structural steel work as in trusses, columns in (tubular/rectangular/square) including purlins, rafter, special shaped washer etc. complete using any dia of MS pipe medium grade/angle or using ERW or induction butt welded tubes/angles conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
M & L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165 complete all as specified and directed.
M&L for prepration of new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in floor/plinth protection laid in suitable panels finished even and fair all as spd . 6mm Joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 gde and three part of sand ( all by weight) complete
Preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white wash.
Total Amount
Signature of Contactor
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
1DRG.rar
Additional Documents • 5.53 MB
tender.pdf
Tender Documents • 4.39 MB
BOQ_837681.xls
BOQ • 0.51 MB
r2.rar
Additional Documents • 5.53 MB
Download all tender documents and submit your bid