Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹25.6 L+₹12,128 (0.48%)Rejected-AOC 178 A BARODIA SCHEME NEAR RAILWAY STATION NEAR RAILWAY STATION BANI PARK JAIPUR RAJASTHAN 302006 UDYAM RJ 17 0169767 | JAIPUR | RAJASTHAN | 302006 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹25.9 L+₹45,445 (1.79%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹30.3 L+₹4.9 L (19.2%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹30.8 L+₹5.3 L (20.9%)Rejected-AOC | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
16 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (South) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
SPL REPAIR TO 10 X MD ACCN BLK P-326/ 1 TO 10 QUEENS LINE OF JAK RIF AT JAIPUR MIL STN UNDER GE (S) JAIPUR
2022_MES_559291_1
GE (S)/J-47P /2022-23 8767/E8
Open Tender
Civil Works
Item Rate
240 days
Jaipur
Class D and category a(i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹52,000
Yes
7 Dec 2022
21 Oct 2022
18 Nov 2022
21 Oct 2022
16 Nov 2022
4 Nov 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 790
S&F light shade Vetrified Ceramic tiles edge cut 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) finished fair and even, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 540
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick edge cut/ joint free (squares/ rectangular) area of each tile exc. 0.11 sqm but not exc. 0.18 sqm, in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 30
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 300mm x 450 mm, 7mm thick over and including 10 mm thick bedding layer in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 220
Taking down cement plaster including raking out joints, hacking for key scrubbing down with water etc built in CM, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 700
M&L rendering 15 mm thick in CM(1:6) on brick walls or concrete surface, surface finished even and fair without using extra cement complete all as specified., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 350
M&L rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brick work of walls, finished fair & even., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 200
M&L rendering 10mm thick in cement mortar 1:3 on concrete surfaces including finished even & smooth without using extra cement on ceiling., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 150
M&L preparation of new plastered surfaces and applying two coats of Oil bound distemper of approved shade/tint over 1mm thick Birla wall care putty on walls all as specified & directed by Engineer-in-Charge , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 200
M&L preparation of new plastered surfaces and applying two coats of Weather base paint over a coat of 1 mm thick birla wall care putty on wall all as specified & directed by Engrr -in-charge, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 350
M&L applying three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 150
Taking down Chowkats or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 32
Taking down Chowkats or frames but area n exc 1.50 Sqm each., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 40
Taking down shutters of any description exc 1.00 sqm but n exc 2.50 sqm each , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 5
S & F in repair Auto close hinges,stainless steel, bright finish or electrogalvanised , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 40
M&L in repair 19mm thick MDF board in Shelf and shutters and partiation of kitchen cabinet, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 110
S&F in repair brass handle of 100mm size cast type, polished bright, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 40
S&F Aluminium, anodised, barrel tower bolts 150mm long of extruded section., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 72
S&F Aluminium alloy, anodised, sliding door bolt 300 mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 24
S&F Aluminium handles 125 mm size, cast type, anodised, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 64
S&F Powder Coating any color (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 100
S&F Powder Coating any color (minimum thickness of powder coating 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) for including powder coating of any colour all as per manufacturers specification, complete all as specified and as directed by Engr-in-Charge. Note: The quoted rate shall be deemed to be included 4.8mm plain sheet glass/ stainless wire mesh 08/SR/61SA/BLDG/22-23: 66
S&F 4mm thick figured glass , pin head type and glazing with oil putty in squares not exc. 0.5 Sqm in each pane, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 40
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staple, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 20
"Water Proof Treatment to RCC Roof comprises the following, complete all as specified and as directed by Engr-in-Charge:- (a) Complete removal of existing roof treatement and disposed off the rubbish outside the defence land (b) All visible cracks to be opened up in V shape cleaned properly with wire brush washed and filled with cracks filling compound using cracks upto 15mm width of cracks (c) cracks of 15mm width are filled with URP cement grouting by injecting nozzles by authorised applicator of manufacturer carefully by following manufacturer's instructions (b) after drying one coat of roof coat paint shall be applied with roller in both directions with a gap of 12 hrs @ 1 Ltr per Sqm (each direction) of roof coat over a roof priming coat of 0.5 Ltr of water mixed to 1 ltr of roof coat (e) necessary gurantee for 10 years shall be submitted by the contractor Make: Sika/ Asian Paints (except Smart Care Damp Proof)/ IWL/ Berger Paints", complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 150
M&L in repair CP cast copper alloy bib taps two way with wall flange and areator fancy tupe of 15mm bore (Make- Parryware CAT PART NO T5034A1 Uno Two Way Bib Cock or equilvalent), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair PVC connection 15mm bore with 2 Nos PTMT nuts, 45cm long fixed with one end to pillar tap & the other end to stop cock or iron pipe, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 20
M&L in repair Towel ring of brass C P Square flange (Make-Parryware CAT PART No T6904A1 or equivalent), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
M&L in repair Chromium plated Overhead Rain shower with relvoling joint and 225 mm long shower arm with wall flange 15mm bore fancy type with arm (Make- Parryware CAT PART No T9814A1 Airmix Shower Head or equivalent), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
M&L in repair Chromium plated angle stop cock with wall flange fancy type cast copper ally 15mm bore any colour (Make- Parryware CAT PART No Alpha G2707A1 or equivalent), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 20
S&F in repair CP bottle trap with internal partition 32 mm size with 300 mm X 190 mm long wall connection pipe and wall flange for WHB (Make-Parryware CAT PART T3201A1 Light 9” or equivalent), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair waste fittings 32mm bore , brass, CP for glazed ware sinks, basins, etc with long screwed shanks & fly-nuts, flange end bedded in red lead cement & other end fixed (Make: Parryware CART PART NO T9911A1 or equivalent), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
Dismantling of old U/S grating and M&L of PVC Nahani / floor trap and square in size of 100X100 mm including MS chromium plated grating 125mm dia of weight not less than 50gm for floor trap / Nahani trap, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 20
Dismantling and taking up or down the existing unserviceable GI pipe and M&L for new galvanised steel water tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors of following sizes :-, complete all as specified and as directed by Engr-in-Charge.
15 mm bore 08/SR/61SA/BLDG/22-23: 100
20 mm bore 08/SR/61SA/BLDG/22-23: 150
Dismantling of old water tanks and S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 500 Ltrs Capacity, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
M&L for providing circular, raised platform of height 20 cm below the tank and base 15cm more than the external dia of thank of PVC cylindrical water tank of capacity 500 liters using PCC 1:3:6 type c1 using 20mm graded stone aggregate with smooth finish , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F Ball brass valves 20mm bore, high pressure, with polythene float & flynut complete, screwed for iron pipe or brass ferrule, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair elegent mirror PVC cabinet of size 450mm x 555mm (Make: Neelkamal Gem Mirror Plastic Wall Mount Cabinet or equivalent) , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair Soap dish brass CP (Make-Parryware CAT PART NO T6403A1 or equivalent) , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
M&L 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base to floor finished fair & even all as specified and directed by Engineer-in-charge., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 100
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 40
S&F in repair stop valve 15mm, copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair Stop valves 20 mm bore, copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints 110 mm rain water pipe fixed to wall, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 26
S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 30
S&F in repair PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 30
S&F in repair PVC (SWR) bends any radius 75mm dia, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair PVC (SWR) bends any radius 110mm dia, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair PVC (SWR), junction single, (Single T) equal or unequal 75mm dia, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair PVC (SWR), junction single, (Single T) equal or unequal 110mm dia, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair PVC (SWR) vent cowl 110mm dia, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
M&L in repair PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
M&L in repair PVC (SWR) gully trap 125/110 mm, setting & jointing with solvent cement, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair bathroom USF Glass corner 9x9 Inches - Glossywall mount (Transparent) glass wall shelf (Number of shelves- 3, clear, steel), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 20
S&F in repair Fancy type MS bracket suitable for curtain rod , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 50
S&F in repair 20 mm dia Drapery Fancy type curtain rod made up of SS , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 75
S&F in repair Fancy type caps/ side Bulbs PVC powder coated suitable for curtain rod , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 50
M&L 50 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in plinth protection finished even and smooth without using exra cement including cutting joints @ 1.2m distance including providing and filling bitumen in the joints , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 38
M&L in repair 15mm bore CP fancy Type Pillar taps, cast copper ally, with capstan heads chromium plated , screwed down high pressure , with or without letterd "Hot " or 'Cold' with long screwed shanks and fly-nuts screwed for iron pipe (Make: Paryyware cat part No. G2701A1 or equivalent), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F in repair Vitreous China wash basin , coloured oval sape, size 550x400mm but including brackets, coupling and wast pipe complete all specified and directed by EIC , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
Demolition of old existing unserviceable WC seat and S & F Vitreous China wash down water closet pan size (530x435x180mm) (pedestal pattern), white including fixing bolts , flushing cistern and flush pipe ,including colour seat cover and bolts etc complete all specified by Engr-in-Charge , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F Wood free EPS Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing and incl Extra for PVC sheet in lipping in case of PVC sheet is heat bent as lipping on the edges of doors complete as per manufacturers specification and direction of Engineer-in-Charge., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 32
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) complete as per manufacturers specification and all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 96
S&F Pressed steel frames 105x60mm sieze for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, supplied and fixed, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 60
S&F Pressed steel frames 125 x 60mm sieze for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, supplied and fixed, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 20
M&L, PCC 1:3:6 type C1 (20 mm graded agg.) as in filling of pressed steel door frame, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 1
S&F MS holdfast, hook and pintle hinges, large hasp and staples, clamps, hooks for hanging fans and similar small articles conforming to Fe-290 Gde E-165 including necessary welding etc. and fixed in position. , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 5
Cutting holes in stone / brick walls built in CM for inserting hold fast & making good dismantled portion in CM (1:3) depth of embaded portion of holdfast n. exc half brick, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 36
Supply and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 20
S&F 100 mm butt hinges medium weight cold rolled Stainless steel, ISI marked, fixed to angle iron chowkats including welding complete., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 96
S&F MS spring hinges 300 mm, ordinary rat tail rod pattern including roller and roller plate complete fixed to wooden/ angle iron chowkats ., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
M&L PCC 1:2:4 mix type B-0(using 12.5mm graded aggregates) as in roof kerbs rounded or chambered on edge., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 0.2
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil bound distemper of approved tint over of wall care putty on ceiling ., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 300
M&L for preparing of old painted surfaces of wood based materials of any description over 10 cm width or girth and applying one coat of synethic enamel paint on wooden surfaces, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 40
M&L for Complete removal of existing treatment and applying two coats of weather coat paint of approved sade over a coat of 1mm thick birla wall care putty on wall etc, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 1000
Demolition of Stone slabs in roofs, suspended floors, chajjas, landings, etc any thickness jointed in any mortar., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 70
M&L green marble work 18 to 20mm thick table rubbed and ploished ) in steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) including pointing in white/coloured cement (1:2) using marble dust with admixture of pigment to match with marble shade over 15mm thick scred bed in CM 1:4 , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 70
Cutting holes into or through cement concrete slabs, chajjas, etc reinforced or otherwise superficial area n. exceeding 100 sq cm., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 15
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for. , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 2
M&L for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base to floor finished fair & even all as specified and directed by Engineer-in-charge., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 40
S&F Stainless Steel Plate (SS-304 Grade) rack of size 24" x 36" x 10" Make Prayag P-336 or equivalent, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
E/M Portion Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 350
M&L Point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade PVC insulated and unsheathed cable drawn through in and incl concealed rigid PVC conduit 20 mm dia medium grade with all accessories ISI marked, including MS sunken box for mounting fitting like switches, sockets fan regulators modulor type etc. including 1.5 sqmm single core PVC insulated but unsheathed copper earth continuty conductor to common earth and connected FRLS cable 1100 V grade as continuous earth wire to earth dolly for followings, complete all as specified and as directed by Engr-in-Charge.
One light/fan/ bell point controlled by one, one way switch. 08/SR/61SA/BLDG/22-23: 240
One 3 pin 5 Amp socket outlet on same board with other switches., 08/SR/61SA/BLDG/22-23: 40
One 3 pin 5 Amp socket outlet on independent board with other switches., 08/SR/61SA/BLDG/22-23: 50
All as per Item No 83 above but with 4 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 4 Sqmm copper cable continuous earth wire and connecting to common earth dolly., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 20
S&F switch/ bell of following types , complete all as specified and as directed by Engr-in-Charge.
Single pole, one way 5 Amp rating 08/SR/61SA/BLDG/22-23: 330
Single pole, one way 15 Amp rating 08/SR/61SA/BLDG/22-23: 10
Bell push Bell push, flush type, 5 amp. 08/SR/61SA/BLDG/22-23: 10
Bell Ding Dong AC 230volts single pole 08/SR/61SA/BLDG/22-23: 10
Supply and fixing of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 30
S&F Socket, piano type 230/250 volts of following type, complete all as specified and as directed by Engr-in-Charge.
Socket 3 Pin, 2 in 1, 05 Amp rating 08/SR/61SA/BLDG/22-23: 90
Socket 3 Pin , 2 in 1, 5 &15 Amp rating 08/SR/61SA/BLDG/22-23: 10
M&L in repair Ceiling rose surface bakelite 65x50mm, three terminals, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 150
Supply & fixing in repair lamp holder PVC body complete all as specified and directed with 01xLED bulb 9 watt , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 70
Taking down exhaust fan of any type and capacity for safe custody to reuse and deposited to MES store yard., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
Supply & fix Exhaust fan steel body AC single phase 230 V of size 300mm sweep heavy duty with blades and frame and louvers all as specified and directed, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
Taking down existing ceiling fan from site and refixing the after doing necessary repair as oiling/greasing/changing of capacitor etc, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 30
Supply & fix LED retrofit lamp ( size-4 feet), Regal Batten for LED tube, universal batten for T5 lamps surface/wall mounting IP 20 with twin core twisted flexible copper conductor cable with suitable size. Make - Havells cat No - REGALBATTENT5UPTO1X18WDSBSWH Or equivalent 08/SR/61SA/BLDG/22-23: 80
Supply & fixing Mirror surface mounted LED fitting 14 W (2 Feet)provided with a high output PMMA diffuser for glare free light , IP 20 with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size. Make - Crompton cat pt No- LCL-14-CDL or equivalent , complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 30
Taking down of DB of any type and capacity, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
S&F factory made, sheet distribution boards, SP&N 12 ways, double door protection class IP-42 double door type suitable for mounting MCB/ MCCB, confirming to IS-13032, IS-8623, BS-5484 with minimum 200 amps, copper bus bar, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
Taking down MCB SP/SPN of capacity, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 90
S&F MCB 10 KA confirming to IS-8828 : 1996, IEC-898 : 1995 rupturing capacity of the under mentioned type and rating, complete all as specified and as directed by Engr-in-Charge.
SP 5 to 32 amps 08/SR/61SA/BLDG/22-23: 80
SPN 32 to 63 amps. 08/SR/61SA/BLDG/22-23: 10
M & L Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn throughn and including PVC rigid conduit and conduit accessories fixed on surface/wall celing etc including provision of 1 run of 4 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 180
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm burried directly in ground (earth pit not less than 2.25 meters deep below normal ground level ), with top edge of the plate not less than 1.5 mtrs below normal ground level , connected to and including galvanised earth strip 25X 4 mm by means of galvanised iron bolts , nut and washers and connected to other end to main panel board duly protected by galvanised iron pipe 25 mm dia " light grage " earth plate surrounded by packed layer of coat dust and common salt 15 cm thick all around bottom and top watering pipe 20 mm bore of galvanised iron " medium grade " with funnel all as shown on electrical plate No 5 of SSR part -I and connecting to earthing testing on completion including cast iron cover frane and PCC 1:3:6 type C-2 using 20 mm grade stone aggregate as in earthing pit with cast iron cover and frame including necessary earth work etc complete all as per specified and directed by Engr-in-Charge . ( Note : PCC Chammer shall be constructed atleast 1.5 mtrs away form the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner). 08/SR/61SA/BLDG/22-23: 10
Taking down US geyser of any type and capacity and deposited to MES store and refixing the same on exsisting site after repair, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
Supply and fixing of single pole and neutral enclosure with a two pin and aearth plug and socket complete with one single pole MCB of 20 Amps 240 vlot, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 10
Taking down US cable of any size and capacity, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 180
M&L Laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade, of size 16 sqmm, 4 core. (cable schedule under B), complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 180
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables errection of poles / struts/stays etc n.exe 10 Sqm on plan not exceeding 1.5 metre in depth and getting out in any type of soil., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 24
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in any type of soil., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 9
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 15
M & L Sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover., complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 14.5
M&L bricks for protection cover to under ground cable (with old size sub class `B` bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm as directed by Engineer in-charge, complete all as specified and as directed by Engr-in-Charge. 08/SR/61SA/BLDG/22-23: 1.7
M/s Bhavesh Construction Company
M/S JALANDRA CONSTRUCTIONS
Stuti Trading Company
UNIVERSAL INFRAPROJECT PVT LTD
JAGDAMBA CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .