| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC VILL SANDIPUR PO DWARNARY DISTT PURBA MEDINIPUR KOLKATA 7134403 WB | KOLKATA | PURBA MEDINIPUR | WB | 7134403 | ₹2.5 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹2.7 Cr+₹21.3 L (8.59%)Rejected-Finance | ₹2.7 Cr+₹21.3 L (8.59%) | L2 | Rejected-Finance Higher biddter |
| 3 | L3₹2.8 Cr+₹28.5 L (11.5%)Rejected-Finance | ₹2.8 Cr+₹28.5 L (11.5%) | L3 | Rejected-Finance Highest bidder |
Tender Value
₹2.5 Cr
EMD Value
₹3.3 L
Closing Date
3 Sept 2024, 6:00 pmClosed
Shri T K Nayak,IDSE
CWE (AF) KALAIKUNDA
DEMOLITION AND RE-CONSTRUCTION OF LEFT OVER HIGH SECURITY WALL ALONGWITH ASSOCIATED WORKS SERVICES AT AF STN KALAIKUNDA UNDER GE (AF) (P) KALAIKUNDA
2024_MES_659993_1
8674/KKD/E8
Open Tender
Civil Works
Item Rate
360 days
AT AF STN KALAIKUNDA
As per NIT
9 documents required · 9 mandatory
₹2,000
GE (P) (AF) KALAIKUNDA
₹3.3 L
Yes
16 Oct 2024
15 Jun 2024
4 Sept 2024
17 Jun 2024
3 Sept 2024
8 Jul 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil or any type of soil, complete all as specified and directed.Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final conclusive and binding.
All as per item No 01 above but exc 1.5m but nexc 3.0 m detpth complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Demolition of concrete of any description and in any position not otherwise specifically provided and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
Demolition of reinforced cement concrete of any description and in any position (Reinforement cut as required to facilitate demolition) and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwiese provided for including gates all as sepcfied and directed
Dismantling of barbed wire of any description and in any positionwith and including clear vegatation on fencing and in floor area to facilatate demolition of any size and section complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
Materials and Labour for brick work with fly ash Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:4), complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating,and roof padding as directed including necessary from work complete all as specified and directed.
Materials and Labour for reinforced cement concrete M-25 Design mix in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete ,complete all as specified and directed.
Materials and Labour for reinforced cement concrete M-25 Design mix in columns; pillars; piers; posts; struts etc,complete all as specified and directed.
Materials and Labour for reinforced cement concrete (M-25) design mix in Columns, pillars, piers, posts and struts with and including appling bond coat of epoxy bonding agent (Nito Bond) & cement in 1 : 1 ratio bonding old and new concrete on old cement concrete surface afer thoroughly abraded to remove all laitance, any trace of loose plaster,cement concrete , oil, grease, paints and any other materials are to be removed by wire brushing the surface. The entire surface shall then be washed thoroughly with plenty of water and then allowed to dry. Defective concrete surfaces cut back to a sound base by chipping and removed loose concrete. Smooth surfaces to achieve by chemically roughenedand all necessary scaffolding and safety measures all as specified and directed. .(The cost of entire operation shall be carried out by approved manufacturers or their authorized applicator and deemed to be included in unit rate).
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces of concrete, square, rectangular or polygonal, complete all as specified and directed.
Supply and fix Galvanised steel concertina coil 610mm dia having 50 turns and approximate weight 8.50kg ± 5% and suitable to be stretched to cover a distance of 5-7 running meter, S clips per spiral using a cental core high tensile wire around which a tape of razor barbs in machine crimped complete all as specfied and directed
S & F galvanized steel barbed wire with two strands of line wire of dia 2.24 mm and barbed with point wire of dia 2 mm at 75 mm spacing straining and fixing to any type of standards, rails, straining bolts including securing or tying at crossings with and provision of galvanised iron binding wire, GI staples or steel pins, etc. complete all as specified and as directed (two strand of line wire will be measured as one unit).
S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed.Note: Independent test report , MTC and purchase voucher shall be sumbmitted before commencement of work and same shall be submitted along with his claim of payment
S&F Roof trusses (framed) trussed, purline crane gantries ,rails and fastenings and heavy brackeet framing (Beam,tee,angle, channel or flat sections) with and including PEB trusses and connected fitting /accessories complete all as specified and shown in drawing and including distance pieces ,cleats etc Fe-410-W (Gde-E-250)quality-A complete all as specified and as directed.
S&F PEB column with and including connected accessories complete all as specified and shown in drawing , compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. builtup from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. Fe 410-W (Gde-E-250) quality - A complete all as specified and as directed.
S&F Mild steel screw bolts(machine made) with hexagonal or square heads of 5 to 10mm diameter neck at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and as directed.
S&F Mild steel screw bolts(machine made) with hexagonal or square heads of 11 to 15mm diameter neck at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and as directed.
S&F Mild steel screw bolts(machine made) with hexagonal or square heads of 16 to 20mm diameter neck at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and as directed.
S&F Mild steel rag or lewis bolts of 25mm dia, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised length of bolt exc 30cm long complete all as specified and as directed.
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated any approved profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height Complete all as specified and as directed.
Supply and fix mild steel TMT bars 5 mm dia. and over up to and including 10 mm dia. in stirrups, spacers, binders etc. cut to length, bend to shape required including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
M&L for cleaning to expose corruded reinforcement of chajja/beam/slab/columns by wire brushing, emery paper or by mechanical means and to remove all loose scale and corrosion deposit and washing complete and providing additional reinforcement TMT bars of approved make of any size , cut to length by electro welding method and applying one coat of rust removing chemical and anti rust coating (zinc) along its full circumference up to 10 Mtr height including all necessary scaffolding and safety measures all as specified and directed. (Manufacturer name of chemical shall be : Fosroc/Sika/Pidilite/BASAF) The cost of entire operation shall be carried out by approved manufacturers or their authorized applicator and deemed to be included in unit rate).
Preparation of concrete surface of chajja/beam/slab thoroughly abraded to remove all laitance, any trace of loose plaster,cement concrete , oil, grease, paints and any other materials are to be removed by wire brushing the surface. The entire surface shall then be washed thoroughly with plenty of water and then allowed to dry. Defective concrete surfaces cut back to a sound base by chipping and removed loose concrete. Smooth surfaces to achieve by chemically roughened up to 10 Mtr height including appling bond coat of epoxy bonding agent (Nito Bond) & cement in 1 : 1 ratio bonding old and new concrete on damaged surface and all necessary scaffolding and safety measures all as specified and directed. .(The cost of entire operation shall be carried out by approved manufacturers or their authorized applicator and deemed to be included in unit rate).
M&L for providiing and placing high built repair ready mix concrete (Micro concrete) grade of M-50 specification and strength conforming to ASTM- C109-99,ASTM- C 307 ,BS1881 Part 207 for grouting/expose corroded reinforcement of chajja/beam/slab with bonding agent as per manufactures instruction (Manufacturer : Fosroc/Sika/Pidilite/BASAF) proper compaction and finished to proper level with and including provision of formwork to the affected portion up to 10 Mtr height including all necessary scaffolding all as specified and directed.(entire operation shall be done by the approved manufacturer or their authorized applicator and deemed to be included in the unit rate)
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Materials and Labour for rendering 5mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface finished even and smooth using extra cement in walls etc, complete all as specified and directed. Note: - 1.(Water proofing compound deemed to be inclusive in quoted rates) 2. second layer shall be applied after complete dried of Ist layer.
Materials and Labour for rendering 5mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on other than fair faces of brick work or concrete surface finished even and smooth using extra cement in walls etc, complete all as specified and directed. Note: - 1.(Water proofing compound deemed to be inclusive in quoted rates) 2. second layer shall be applied after complete dried of Ist layer.
M & L for applying Two 100 % Acrylic Exterior Emulsion paint as approved pattern ( colours as approved by GE) (Berger,Weather coat Advanced XP long life Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand over a coat of exterior wall primer on new concrete/wall over and including 1mm thick external wall putty in two layer surfaces up to 10 Mtr height including all necessary scaffolding and safety measures complete all as specified and directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
S&F LED high bay light (round) having high efficiency with pressure die-cast housing,having fin ventilation technology for better thermal management, having efficiency of 150 Lm/ Watt, of capacity of 80 watt, IP 66, 240 Volt, 50 HZ, for installation in hanger roof by providing all necessary accessories, MS clamp for hanging and fixing of light fitting including making electrical connection by providing 1.5 Sqmm x 3 core sheathed flexible copper conductor cable from light fitting to source of supply complete all as specified and directed. Note : (i) All LED Highbay light fittings street lights shall be properly connected with earth dolly provided with fittings and earth conductor/ earth wire. (ii) All LED lights have replacement warranty of 3 years from the date of completion of the contract. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 3 year replacement warranty certificate. (iii) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact. (iv) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries. (v) All LED fitting shall be identified by printing or fixing stickers duly mentioned the C.A number and date of completion. (vi) For any change in product or change in catalogue No. etc due to technological upgradation, letter has to be obtained from the lighting company on their letter head signed by an offical of National level. (vii) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade 4.00 Sqmm (Nominal area) FRLSH PVC insulated and unsheathed copper conductor cable, having multi-stranded copper conductor drawn in but including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc as approved by EIC including PVC insulated unsheathed FRLSH cable 4.0 Sqmm cable with multistranded copper conductor green colour as contineous earth conductor cable connected to earth dolly complete all as specified and directed. Note: Two single core 4.00 Sqmm cable for phase and neutral and one single core 4.00 Sqmm cable as earth conductor including steel conduit shall be measured as one run.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, Triple pole & neutral with 100 amps rated bus bar, 415Volt door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. Note : (i) MCCB and DB box shall be of same make.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 32 to 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
M&L for Earthing complete with Galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground with earth pit not less than 3.25 meter deep below ground level with top edge of plate not less than 2.5 meter below normal ground level connected to galvanised iron strip 32x6 mm as earth lead strip by means of nuts, bolts, check nuts, washers of galvanized iron as steel all as shown electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and elctrode by means of steel and GI pipe light grade 20mm bore dia bore for watering funnel with wire mesh, CI cover with frame , PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified. NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI strip of 32x6 from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
S & F LED street lights nominal power 45 Watt, LED of Make Osram; Bridge Lux; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 5400, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with L70 and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge. Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. .
M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.6 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick 2-nos mild steel nuts, bolts incuding painting two coats of aluminium paint over a coat of primer all as specified and directed by Engineer In Charge
CASTLE BUILDERS (BID ID -3070893)
BHOWMICK ENTERPRISES INDIA (BID ID -3060440)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .