| Sl No | Description | Qty | Unit | SUPPRIM ELECTRIC L3 | M/S S S UDYOG L2 | N C MISHRA AND CO L1 |
|---|---|---|---|---|---|---|
| 1.01 | TOTAL | 1 | Nos | 4,92,845.05 ₹4,92,845.05 | 4,91,288.56 ₹4,91,288.56 | 4,89,710.62 ₹4,89,710.62 Lowest |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
14 Jan 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
D.G.(S and D)
Office of the Director General (Sewerage and Drainage), SEWARAGE and DRAINAGE department Kolkata Municipal Corporation 5, S.N. Banerjee Road Kolkata-700 013 West Bengal
Restoration, repairing with replacement of damage accessories of star- delta motor starter panel of pump unit 1 at Topsia Point A drainage pumping Station.
2025_KMC_978127_1
KMC/S_D/TDPS/PN1/25-26
Open Tender
Electrical Work/ Equipment
Item Rate
7 days
DLPS/TDPS
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹10,000
27 Feb 2026
30 Dec 2025
16 Jan 2026
30 Dec 2025
14 Jan 2026
30 Dec 2025
TOTAL
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Thorough checking , testing of the motor starter panel by proper instrument in proper way and detection of fault.Dismantling and taken out all spare parts (like timer, power contractors,auxilary contractor, earth fault relay, overload relay moisture & winding temperature relay, etc.) including circuit wiring (power &control) from the starter panel.Dismantling the existing busbar from the panel, cleaning the starter panel by the proper method using petrol & CTC
Supply of 630 A(AC3) , 415 V , 3 PHASE , 50 KA Microprocessor Release MCCB L&T / ABB/ C&S MAKE.
Supply of bimetalic over load relay (500-290AMP), C.T operated, separately mounted & CBCT ( 500/5A,15 VA ) reputed make, reputed make (L&T /G.E)
Supply of ( 210KW-250 KW) (290 -380 Amps ) (AC3) , 415 V 3, pole power contactor( with Aux. contact 2 NO +2 NC ), L&T / ABB/ C&S MAKE
Supply of Auxilary contact ( 2 NO + 2 NC. 230V COIL ) , L&T / ABB/ C&S MAKE
Supply of Auxilary contact ( 3NO +1 NC. 230V COIL ) , L&T / ABB/ C&S MAKE
Fitting , fixing of ( power circuit & control circuit all the electrical measuring instrument, contactors ,breaker ,indicating lamps, push button , relays, aux,contacts, C.Ts, CBCTS e.t.c with necessary standard insulators
Supply of analog Square Ammeter (AE/ reputed make) as per existing specification and C.T. Ratio & Earth fault relay ( 230V COIL, 80 A-800A ) , LEGRANDS / ABB/ MINILAC make
Complete internal control wiring & fitting,fixing of power cirrcuit ( using Al. busbar) connections with necessary standard insulators.
Flat Al. Bus bar ( 100 mm X 15mm ,1000 A ), 8.27 Mtrs ,(Wt./ Mtrs is 13.00 kgs , for 8 Mtrs Wt. = 104.00 kgs) (In kgs)
Supply of single phase preventor( 240V ,/ 415V) reputed make (L&T /MINILAC) & BCH (KRTPN) pneumatic Timer( 3-30SEC, 2NO+2 NC),240V reputed make (L&T /MINILAC)
Necessary checking testing including commissioning of indication the closing & starting tripping arrangement of all the protection relays of panel, annunciator respect to all indication.
Supply & fixing Push button Switch make vishno / ESSBEE (for start / stop/ reset)
Supply fixing of stud type LED indicating lamp (110 to 230Volt) (For phese & ON/OFF indication)
Suppliying of following XLPE insulated Aluminium conductor armored cables of 1.1 kv grade as per IS 7098 (Part-1) 1988 with upto dated amendments.(Rate in Rs. Per Mtr) size 240 Sq mm. × 4 core.
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl.removing the rubbish Above 95 and above sqmm at an average depth of 100 mm in floor/pavement/wall etc. (IN RUNNING METER)
Supplying and fixing compression type gland including supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below 4 Core, 240 Sqmm (EACH)
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as require Up To 50 m.m (IN RUNNING METER)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
FORM.pdf
Tender Documents • 0.68 MB
BOQ_2383792.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .