Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC 25 SIRAJ DULA SARANI KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | L1 | Accepted-AOC Stands Lowest | |
| 2 | L2₹2.8 L+₹777.90 (0.27%)Rejected-AOC 35 DHARSA MAHITAL KHAN S BYE LANE JIGACHA MUKHERJEE PARA HOWRAH PIN 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | L2 | Rejected-AOC Stands2nd Lowest | |
| 3 | L3₹3.3 L+₹48,810.74 (17.2%)Rejected-Finance 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | L3 | Rejected-Finance Stands 3rd Lowest | |
| 4 | L4₹3.4 L+₹56,683.90 (20.0%)Rejected-Finance DAKHIN SHIBGANJ P O PATHAR PRATIMA SOUTH 24 PGS | PATHAR PRATIMA | SOUTH 24 PARGANAS | WEST BENGAL | 743371 | L4 | Rejected-Finance Stands 4th Lowest | |
| 5 | L5₹3.4 L+₹58,630.90 (20.7%)Rejected-Finance SARBERIA NARAYANDARI PURBA MEDINIPUR 721655 | NARAYANDARI | PURBA MEDINIPUR | WEST BENGAL | 721655 | L5 | Rejected-Finance Stands 5th Lowest |
Tender Value
Refer Docs
EMD Value
₹6,857
Closing Date
13 Jun 2022, 1:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Office of the Executive Engineer, Purba Medinipur Electrical Division, P.W.Dte, Tamluk, Hospital More
Civil and Electrical works for establishment of Model Career Centres at Haldia Employment Exchanges under National Career Service Project--- Internal E.I. Work.
2022_WBPWD_383279_1
WBPWD/EE/PMED/eNIQ-07/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Haldia
Please refer Tender documents.
5 documents required · 5 mandatory
₹6,857
Tamluk
11 Jul 2022
1 Jun 2022
15 Jun 2022
1 Jun 2022
13 Jun 2022
7 Jun 2022
6 Jun 2022
Supplying and fixing 415V,63A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
Supplying & fixing sheet metal (16 SWG) Iron clad busbar chambers of the size: 4 bars, 415 V, 100/125 A, Dimension of Cu bars (85 mm long) - 4 x 15 x 3 mm, Dimension of sheet metal box - 500 x 150 mm on angle iron frame on wall, incl. earthing attachment and painting as required. (As per drawing no.- 470 of PWD Specification Book- May, 1991)
Supplying and fixing 415V, 63 A, 4P on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Make: Havells)
Supplying and fixing double door 4-way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 4 way Enclosure (607715), 63A FP isolator as incommer & 6-32A SPMCB -12nos as outgoing (all make legrand) (for lighting circuit)
Supplying and fixing double door 6-way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 6 way Enclosure (607716), 63A FP isolator as incommer & 6-32A SPMCB -18 nos as outgoing (all make legrand) (for AC & power plug)
Supplying and fixing 2+12-way double-door SPN MCB Distribution Board with IP-42/43 protectionand comprising with 1 no. 40A DP Isolator as incomer and 10 nos. 6-10A SP MCB as outgoing , concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Legrand make-607712)
Supply & Delivery of 1.1 KV grade 4 Core 16 sqmm XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith. [Make: Havells/RR Kabel /Gloster/Polycab] (from main switch to busbar to changeover switch to HTPN DBs)
Laying of 4 Core 16 sqmm XLPE/PVC armoured Al cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Laying of 4 Core 16 sqmm XLPE/PVC armoured cable after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average 75 mm depth and mending good the damages to original finish incl. removing the rubbish.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables for following XLPE/PVC armoured cable: 4 Core 16 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: 4 Core 16 sqmm
Supplying and fixing 20 mm dia PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
Cutting channel of 40 mm x 40 mm/43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works: 19 mm dia 3 mm thick polythene pipe without earth continuity wire.
25 mm dia 3 mm thick polythene pipe without earth continuity wire.
Supplying and Drawing 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed single core stranded copper wire (make:- Polycab/Havells/RR Kabel/Finolex) of the following sizes in the 19/25mm prelaid polythene pipe concealed in wall incl suitable size 16 SWG inspection box: 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC in prelaid 25mm dia 3mm thick polythene pipe (from TPNDB to SPNDB)
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC in prelaid19 mm dia 3mm thick polythene pipe (for 1-ph AC machine)
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC in prelaid19 mm dia 3mm thick polythene pipe (for 20 A power plug & computer board)
3 x 22/0.3 (1.5 sqmm) in prelaid19 mm dia 3mm thick polythene pipe (2X6A power plug)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes: 2.5 sqmm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/RR/Polycab) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl.175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. (only PVC Rigid Conduit on ceiling and remaining portion concealed) Average run 6 mtr
Distn. wiring in 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make Havells/ Finolex/ Polycab/ RR) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. (on board)
S & F MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting. – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & Fixing Socket type fan regulator (Step type) (Make-Anchor) with safety wire & S3 capacitor on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
S & F of 1200 mm AC ceiling fan, with safety wire & S3 capacitor, in brown color (Make: Orient Quaser/ Crompton RIVIERA high speed/Usha Striker) complete with downrod, canopy fork, blades etc as per GS.
S & Fixing Single/Twin 4' LED tube light fitting (Make: Philips ,Cat no. TMC 501 P, with MAS LED tube 2100lm/Crompton/Havells/Wipro) suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5 sqmm.) flexible copper wire of 1.10 mt. length. Single fitting. (with 01 no LED tube 1200 mm )
Double fitting. (with 02 no LED tube 1200 mm )
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Make-Anchor-Penta) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(Computer Plug)
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Make-Anchor-Penta) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/ perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/ perspex cover and making necessary connections as required. (1x20A Power plug)
S&F 240 V two nos 5 Pin 5A flush type plug socket with two 5 A Piano key type (Anchor make) switch on sheet metal box with bakelite top cover and earthing attachment incl. S&F sheet metal box [16 SWG] of size (175mm x 100mm x 65mm) with 3mm thick bakelite top cover. (Seperate board)
S&F following dia heavy duty industrial type exhaust fan with louver shutter heavy gauge to be fixed on wall with necessary cutting of wall etc. and mending good the damages. (Make: EPC). 12" dia
Supply & Fixing 9 W LED lamp on existing holder point. (Make: Crompton / Philips/Havells/Wipro)
S & F Industrial Plug & Socket board with 240 V, 32A, 2P+E-DP Industrial Plug socket & 32A Industrial top incl. S & F 32 A DP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and necessary conection. (Make - Legrand, Cat. No.- 5078 63 ) (for UPS connection)
Supply & Fixing 240 V, 25 A, Modular type OLP in (Make: Electron OLP 3+ or similar) 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make: Legrand- Myrius/ Mk Honeywell/ Anchor Roma Urban), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make: Legrand- Myrius/ Mk Honeywell/ Anchor Roma Urban) & necy. connections.
Earthing By 50mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) 4 SWG wire on wall/floor with staples buried inside wall/ floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
SITC of road lighting luminaire ( IP 65 ) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system, 10KV SPD, THD < 10%, PF> 0.95, BIS approved silicon filled potted driver, minimum LPW 110 lumen/w and minimum system output 2500 lumen, suitable for use with 230Volt 50Hz. (Make: Philips/ Crompton/ Havells/ Wipro)
S&F 1.5 mtrs Long 40 mm dia GI detachable "L" type arm bracket with half round GI clamp-02nos., nuts etc as required with painting by one cote red led, with 2cote aluminium paint. (N.S.) Terms and condition 1. The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. 2. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
CHAKRABORTY ELECTRIC
MAA TARA ENTERPRISE
B. ENGINEERING CO.
MAA NACHINDA ELECTRIC
CHANDIMATA TRADERS
S. D. Construction
technical_749114.pdf
PDF • 0.23 MB
techsummary_749114.pdf
PDF • 0.02 MB
finance_749114.pdf
PDF • 0.27 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_749114.pdf
PDF • 0.30 MB
FWO.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .