Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹47.3 L+₹3.7 L (8.47%)Rejected-Finance 5C H M APARTMENT SATI JAYMATI ROAD ATHGAON KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
17 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UMROI
Military Engineer Services Garrison Engineer Umroi Umroi Military Station PO - Barapani, Shillong-793 103
PROVN OF 01 X BORE WELL AT UMROI MIL STATION UNDER GE UMROI
2024_MES_653839_2
8839/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE UMROI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UMROI
₹86,000
Yes
25 Oct 2024
25 Jul 2024
18 Sept 2024
25 Jul 2024
17 Sept 2024
1 Aug 2024
Amount
Trial bore hole of 200mm dia with DTH or reverse rotary circular/direct circulation method or combined in both the processes as per site reqmt in any kind of soil strata including lifting and boring device and casing pipe etc complete all as specified and directed 0 to 250 mtr depth from ground level, (Note : total 04 points shall be given for trial holes one by one untill the suitable strata and yield is achived) including providing PCC Cover on unsed bore hole/ trial bore hole ccomplete all as specified and as directed.
Development by suitable boring with DTH or reverse rotary circulation or direct circulation method or combination of both by using power rig ( preferably with DTH rig) for any kind of soil, boulders as per the method recommended in survey report and the nature of strata underground from normal ground level upto a depth of 250 metre BGL through any type of soil/rock/any other fmn suitable for 200 mm dia assembling of pipes including collection of soil strata sample every after one mtr after 30 mtr depth below ground level (BGL).
All as per item No 02 but for depth from GL upto 675 mm for 50 RM from ground level
All as per item No 02 but for depth from 50 Mtr BGL to 100 meter
All as per item No 02 but for depth from 100 Mtr BGL to 200 meter
Note:- for item 3 above :- (a) Depending upon the nature of strata encountered and availability of fractures in the strata to allow percolation of water. If drilling beyond, 200 mtr is reqd the same shall be carried out with written approval of the Engr -in-Chagre. (b) The rate for drilling beyond 200 mtrs will be considered the same as in item No 5 above :- (i) Geophysical logging of the bore holes under Sri No 3 to 5 to be done after completion of drilling but before lowering the housing pipe etc. (ii) Strata samples to be collected during drilling and preserved in PVC container mentioning details for analysis and preparation of Lithologic log. (iii) Depth of the bore shall be decided by the Engr-In-Charge/AGE which will be final and binding. (c) (i) No extra payment is involved to cutting of small boulder, hard rock boulder etc if any bore upto drilling of 50 mtrs from the GL. (ii) Cost of yield test and verticallity testing, watering testing shall be deemed to be included in the cost of drilling.
Supply and lowering 200 mm bore flanged type long heavy duty MS casing pipe jointing with bolts, nuts, washers, rubber gasket incl making/ cutting groove at flanged complete all as specified and directed.
Supply and lowering 150 mm bore flanged type long heavy duty MS casing pipe jointing with bolts, nuts, washers, rubber gasket incl making/ cutting groove at flanged complete all as specified and directed.
Supply and lowering 80 mm bore flanged type long heavy duty MS column pipe jointing with bolts, nuts, washers, rubber gasket incl making/ cutting groove at flanged complete all as specified and directed by Engr-in-Charge. Make : Tata/ Jindal/ Bansal
Supply and lowering Cage type strainer LCG (Lower carbon Galvanised ) 7.0 mm thick conforming to IS 8110,200 mm dia size 09 Ft slot 1 x 4.95 mm wall thickness 7 mm and welded with MS pipe and heavy duty collar and welded centre glide MS flate iron 20 x 6 mm, complete all as specified and directed by Engr-in-Charge
Development of tube wells with air compressor of suitable capacity till sand/mud free water of potable quality is obtained and to achieve minimum discharging capacity or 10000 GPH (Hire charges of Compressor with accessories and fuel reqd for devlopment of tube well incl tpt to work site shall be deemed to be included in the unit rate quoted by the contracor ) complete all as specified and as directed.
S&F Pressure guage 100 mm dia 0. to 21 Kg per/CM2, complete all as specified and as directed. Make: FILBIG/ GURU
M&L for carrying out electric logging test of the drilled bore hole upto the depth of pilot bore below ground level and submission of the log report in triplicate, complete all as specified and directed by Engr-in-charge. .
M&L for MS reducer, bail plug, well cap, MS strip for centering, MS iron clamps for holding 80 mm bore column pipe bent to shape as required including drilling holes and provision of nut and bolts and washer (Clamp shall be made out of 700mm long MS Flat iron of Size 150x10mm thick), complete all as specified and directed.
M&L for sample strata box made out of wood sample received from different strata during digging at interval of 5.0mtrs, complete all as specified and directed by Engr-in-charge.
M&L for testing of borewell water for min acceptable aty of discharge capacity 2800 GPH at 150 Mtrs head by doing continous pumping of water upto 16 Hrs to determine actual pumping yield of the borewell though yield test by V-notch method and any othe methed available complete all as specified and directed.
M&L Pipe 100 mm bore steel water tubing medium grade galvanised with all fitting and laid in trenches complete all as specified and directed by Engr-in-Charge.
Supply, laying, testing & commissioning of submersible cable 10 Sqmm 3 core, Flat with stranded copper conductor, PVC insulated and PVC sheathed 1100 volts grade, compete all as specified and as directed.
M&L for fixing/passing through pipe including jointing and testing of PVC/XLPE insulated and PVC sheathed armoured electric cable (heavy duty) with aluminium conductors 1100 volts grade conforming to IS7098 Part-I cross sectional area 50 Sqmm 3.5 core complete all as specified and directed
S&F DI sluice valve with SS spindle double flange conforming to ISI 14846 both ends flanged class PN 1.0 size 80 mm dia incl necessary nuts, bolts, washer and gasket complete all as specified and directed by Engr-in-Charge.
S&F DI valve reflux (NRV) confirming to IS 14845 screwed both ends meant for horizontal pipes chromium S/S parts of size 80mm bore complete all as specified and directed.
S&F cast iron air release valve double acting including jointing materials such as gaskets, nuts and bolts complete double air outlet of size 100mm dia complete all as specified and directed by Engr-in-Charge.
Meterial and labour for construction of block masonary valve pit of size 120cmx120cmx120cm (internal dimension) and MS plate cover with angle iron frame, hings and locking arrangements and handle including necessary excavation in any type of soil, returning filling in and removal of surplus soil to distance not exc 50 mtr, rendering block masonary wall in cement motor (1:4) (internaly/externaly) and applying two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces, complete all as speciffied and directed.
Supply, install, testing and commissioning of submersible pumping set less than 15 HP capacity electrically driven with supply voltage of 415 volts adn 520 cycles with discharge capacity 120 LPM at 117 Mtrs head of outlet of suitable size including spring loaded SS suction strainer adn conected with column pipe complete all as specified and directed. Note :- Column pipe of 80 mm bore shall be connected with submersible pump without any extra cost to the contractor
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of CI/GI/DI/PPR pipe and getting out in soft/loose soil, complete all as specified and directed by Engr-in-charge.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed by Engr-in-charge.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning in trenches for protection of under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable and punning down, complete all as specified & directed. Note : For the purpose of payment only punned down thickness shall be measured.
M&L for common burnt clay building bricks (locally available best quality), sub-class ‘B’ designation 75 of size 230x115x75 mm to cover LT underground cables , laid dry and flat complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600cmx600cmx6mm thick buried directly in ground vertically to a depth not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earth strip of size 32 x 6mm earth lead by means of nuts bolts, check nut and washers of galvanised steel, earth strip protected by and including GI Pipe 40 mm bore (light grade ) and connected to main test point as directed including concrete pit in PCC (1:3:6) type C1, precast RCC (1:1:5:3) type A1 cover slab 40x40x 5 Cm reinforced with 8 mm dia MS bar @ 150 cm c/c both way with one handle for lifting, made out of 8 mm dia MS bar embedded in pre-cast conver slab, funnel, wire mesh, 20 mm bore glvenised or steel pipe (medium grade) for watering, charcoal & salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as specified and directed.
M&L for Packing Carefully filter media of size 25-40mm, smoothand round oval in shape free from clay/dirt in filter bed complete, complete all as specified and directed.
M&L for Packing pea size washed gravel sorrunding between assembly pipes and bore holes top to bottom using 3 mm gravel size, complete all as specified and directed.
M/s JK Jangid and Company (BID ID -3094307)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .