Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1 BAMANAI LUHETA HATHRAS HATHRAS UTTAR PRADESH 204101 | HATHRAS | UTTAR PRADESH | 204101 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹48 L
EMD Value
₹48,000
Closing Date
13 Dec 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
SE, EDC-1, Meerut
ETN0-68/EDC-MT/2024-25
2024_PVVNL_970006_2
ETNo.68/EDC-MT/2024-25
Open Tender
Electrical Works
Lump-sum
180 days
Under EDD-I, III AND IV
ETN0-68/EDC-MT/2024-25
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER
₹48,000
14 Dec 2024
21 Nov 2024
13 Dec 2024
21 Nov 2024
13 Dec 2024
21 Nov 2024
Amount
Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :-
ST Pole 11 Mtr. Long.
PCC Pole 8.5 Mtr Long.
33 KV XLPE Cable 3x300 sq.mm.
33 KV J/KIT 3X300 sqmm
11 KV XLPE cable 3x185 sq.mm
11 KV J/KIT 3X185 sqmm
11 KV XLPE cable 3x120 sq.mm
11 KV J/KIT 3X120 sqmm
11 KV XLPE cable 3x70 sq.mm
11 KV J/KIT 3X70 sqmm
Weasel Conductor
Rabbit Conductor
Dog Conductor
LT ABC 3x50 sqmm
11 kv Pin Insulator
11 kv Disc Insulator
T/off Channel
Top Channel
Dropper Channel
11 KV X ARM
MS Angle
Bracing Angle
Stone Pad
Stay Set Complete
Earthing Set Complete
GI Wire 8 SWG
11 KV VCB O/G 200/100/5 A
11 KV CT/PT 200/100 A
Fuse Set
F-Bracket
11 KV TPMO
11 KV XLPE cable Box 3x185 sqmm
Erection of STP Pole 11 mtr long with grouting after digging a pit of size 1.6 mtr deep in all type of Soil including back filling of the pole with proper ramming after completion of work (as per UPPCL Respo).
Erection of PCC pole 8.5 Mtr long with grouting after digging a pit of size 1.6 mtr deep in all type of Soil including back filling of the pole with proper ramming after completion of work (as per UPPCL Respo).
Laying of XLPE Cable of size 3x35/3x70/3x120/3x185 sq.mm pit of the size 1.5 in the trench and road crossing in the air (D.C) (as per UPPCL Respo).
Fixing of 33 KV J/KIT 3X300 sqmm (as per UPPCL Respo).
Fixing of 11 KV J/KIT 3X185 sqmm (as per UPPCL Respo).
Fixing of 11 KV XLPE cable Box 3x185 sqmm (as per UPPCL Respo).
Fixing of 11 KV J/KIT 3X120 sqmm (as per UPPCL Respo).
Fixing of 11 KV J/KIT 3X70 sqmm (as per UPPCL Respo).
Stringing of Weasel Conductor (as per UPPCL Respo).
Stringing of Rabbit Conductor (as per UPPCL Respo).
Stringing of Dog Conductor (as per UPPCL Respo).
Stringing of LT ABC 3x50 sqmm (as per UPPCL Respo).
Fixing of 11 kv Pin Insulator (as per UPPCL Respo).
Fixing of 11 kv Disc Insulator (as per UPPCL Respo).
Fixing of T/off Channel (as per UPPCL Respo).
Fixing of Top Channel (as per UPPCL Respo).
Fixing of Dropper Channel (as per UPPCL Respo).
Fixing of 11 KV X ARM (as per UPPCL Respo).
Fixing of MS Angle (as per UPPCL Respo).
Fixing of Bracing Angle (as per UPPCL Respo).
Fixing of Stone Pad (as per UPPCL Respo).
Fixing of Stay Set Complete (as per UPPCL Respo).
Fixing of Earthing Set Complete (as per UPPCL Respo).
Laying of GI Wire 8 SWG (as per UPPCL Respo).
Erection of 11 KV VCB O/G 200/100/5 A (as per UPPCL Respo).
Erection of 11 KV CT/PT 200/100 A (as per UPPCL Respo).
Fixing of Fuse Set (as per UPPCL Respo).
Fixing of F-Bracket (as per UPPCL Respo).
Erection of 11 KV TPMO (as per UPPCL Respo).
Providing and Fixing of Holding Clamp (as per UPPCL Respo).
Providing and Fixing of GI Pipe 6 dia (as per UPPCL Respo).
Providing of HDPE Pipe 6 dia (as per UPPCL Respo).
Laying of cable with HDPE Pipe 6 mm dia(Double circuit) (as per UPPCL Respo).
Laying of cable with sand and bricks (as per UPPCL Respo).
Trenchless boring (as per UPPCL Respo).
Providing and fixing of F-Clamp (As Per Direction of Supervising Engineer).
Providing and fixing of Suspension Clamp With hook (As Per Direction of Supervising Engineer).
Providing and Fixing of Danger Plate (As Per Direction of Supervising Engineer).
Providing and Fixing of Barbed Wire (As Per Direction of Supervising Engineer).
Providing and fixing of MS Nut and Bolts(As Per Direction of Supervising Engineer).
Fixing of Stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. (As Per Direction of Supervising Engineer).
Recived Back 33 KV XLPE Cable 3x300 sqmm (As Per Direction of Supervising Engineer).
Recived Back ABC Cable (As Per Direction of Supervising Engineer).
Recived Back STP Pole 11 mtr long (As Per Direction of Supervising Engineer).
Recived Back Weasel/Dog conductor (As Per Direction of Supervising Engineer).
Recived Back Cross ARM (As Per Direction of Supervising Engineer).
Recived Back G.I. Wire (As Per Direction of Supervising Engineer).
Vivek Electricals (BID ID -4785609)
Bobby Electricals (BID ID -4785921)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .