Chief Manager Works
Proposed modification to existing MCSRDC Building in ADB area for insourcing of printing press facility including Civil Electrical and Allied works for ARDC Division HAL Bangalore
TENDER NOTICE/NCP/38/26-27::HAL/FMD/R-40/26-27
TENDER NOTICE/NCP/38/26-27
Open Tender
Works
06MONTHS
Contract Section Civil-FMD-Bangalore
Refer Tender Document
₹0
Exempted
7 Jul 2026
7 Jul 2026
3 Oct 2026
3 Oct 2026
17 Jul 2026
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Year of Estblishment of Company/Business
If Other, please specify
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc.,
Address for correspondence:
PAN no and Name of Holder
PF number (If any)
ESI number
Goods and Service Tax ID No.
Contact details
Registered Contractor
Pls Enter
I.T Returns for past 03 assessment years
Turnover during the following 5 years (In Rs. Lakhs)
Pls enter Finiancial Turnover in Rupees Lakhs for all the years
DETAIL OF WORK ON HAND UPTO N-Months (N-contract period) [For Bid capacity calculation] NOTE : CA certified statement as per below format to be uploaded.
Name of Organization with address
Work Schedule for completion of works with in stipulated time [Please enclose action plan / bar chart as to indicate the completion of work, within the scheduled time (contract period)]
Bank(s) details: [Copy of ECS and cancelled cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Bank Statement for past three month
Latest Overdraft Facilties with Bank enter Name of Bank, Date of Issue and Value of Over Draft
Solvency Certificate Details
Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender. [Work experience certificates / Completion certificates should be uploaded for verification]. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of the estimated cost. [Amount put to the Tender]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work and Organisation name [ Incase of private works the same shall be supported with TDS certificate]
Related Document to be Uploaded to eProcurement Portal
DEAILS OF TECHNICAL PERSONNEL AVAILABLE( if space provided is insufficant separate sheet to be uploaded with the same format as below)
Name of members or technical personllel avalable in the organization
DETAILS OF MACHINERY AVAILABLE
Name of Mechinery
Concrete Mixers - Type etc
Vibrators - Diesel - Electrical
Weiding equipment's
a) Rectifiers
b) Welding Generators
Erection equipment's
Cranes-
Hoists-
Lifts-
Water Lifting motor pumps
a) Diesel
b) electric
Drilling Equipment's
Compressors
Trucks
Stone crushers
Bitumen hot mixture plant
Bitume boiler
Rollers
Batching plants
Vibratory rollers
Generators
Cranes-Details
Concrete pumps
Road Pavers
Rock breakers
Transit mixers
Excavators
Weight batches
Others
DECLARATION
Pls enter
EMD details
Enclosed / Not enclosed
Enclosed
Average annual financial turn over during the last 3 years, ending 31st March 2025 and details for last 5 years to be provided to assess the bid capacity. The values provided to be supported by uploading Balance Sheet along with Profit & loss account (In Rs. Lakhs)
Specification
Dismantling 15 to 40 mm dia G.I./cpvc pipe including stacking of dismantled pipes (within 50 metres lead) including making temporary arrangements for continuing ongoing services to toilets etc., all complete as directed by Engineer-In-Charge .
Making the opening/chippig for doors/ windows/ ventilators in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls,flooring and jambs complete, to match existing surface,curing,leveling,including disposal of mulba/ rubbish to the nearest municipal dumping ground upto a distance of 50m, etc., all complete as directed by Engineer-In-Charge .
Dismantling EWC/IWC Pans/urinals with associated fixtures and accessories of all sizes including disposal of dismantled materials i/c malba,making temporaray arrangements for blocking service lines to avoid water leakages etc., all complete as directed by Engineer-In-Charge.
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 10 kilometre outside HAL, stacking serviceable and unserviceable material separately including cutting reinforcement bars,after making temporary proetction for existing service lines and Existing Lintel Beams etc., all complete as directed by Engineer-In-Charge .
Demolishing brick work with cement mortar manually/ by mechanical means, after disconnecting the electrical service and AC lines if any, including stacking of serviceable material and disposal of dismantled materials up to a lead of 10 kilometre outside HAL etc., all complete as directed by Engineer-In-Charge .
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or richer mix (i/c equivalent design mix)and including stacking material and disposal of dismantled materials up to a lead of 10 kilometre outside HAL,after making temporary proetction for existing service lines etc., all complete as directed by Engineer-In-Charge .
Dismantling doors, windows/ventilators and clerestory windows (steel or wood) shutter including chowkhats,steel frames,grills , glass,architrave, holdfasts andother fixtures etc. complete and stacking within 50 metres lead of area 3 sq. metres and below, including stacking material and handing over the useful materials to HAL maintenance department and disconnecting the service lines if any etc., all complete as directed by Engineer-In-Charge .
Dismantling of road gully chamber/trap of various sizes including C.I. grating with frame and making temporary arrangements to protect ongoing service lines,including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap etc., all complete as directed by Engineer-In-Charge .
Dismantling/removing Vitrifed/mosaic tiles,granite,PVC sheets (upto 40mm tile thickness.) in floors and walls laid on cement mortar ,after disconnecting the electrical service and AC lines if any,including stacking material and disposal of dismantled materials up to a lead of 10 kilometre outside HAL etc., all complete as directed by Engineer-In-Charge .
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including all accessories and stacking of useful materials near the site,making temporary arrangemnst to avoid water leakage and disposal of unserviceable materials within 50 metres lead etc., all complete as directed by Engineer-In-Charge .
Dismantling/Removal of Aluminium partition, Gypsum partitions,FRP/aluminum doors, windows,ventilators including glazings and False ceiling with grids & tiles including disposal of unserviceable material, handing over usefull materials to user department and stacking of serviceable material with in 50 meters lead etc., all complete as directed by Engineer-In-Charge .
Dismantling steel work in single sections welded,anchored including associated woden railings etc (Channels, angles, tees and flats ) including dismembering and stacking within 50 metres lead and handing over the usefull materials to user department etc., all complete as directed by Engineer-In-Charge ..
Dismantling C.I./asbestos/PVC rain water pipe with fittings and clamps including stacking the material within 50 metres lead and handing over the useful materails to user department etc., all complete as directed by Engineer-In-Charge .
upto 100 mm dia
Above 110mm to 150 mm dia
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding like rolling shutters,louvers,gates etc etc. including dismembering and stacking within 50 metres lead and handing over the usefull materails to user department etc., all complete as directed by Engineer-In-Charge .
Hacking of existing CC flooring including cleaning for surface and making suitable for new tiles flooring etc., all complete as directed by Engineer-In-Charge .
Disconnecting damaged overhead/terrace PVC water storage tank of any size/capacity from water supply line and removing from the terrace including shifting at ground level etc., all complete as directed by Engineer-In-Charge .
Removing existing roof top water proofing APP membrane/plastic felt etc ,and the like by scrapping, sand papering and preparing the surface to lay the new water proofing materails etc., all complete as directed by Engineer-In-Charge .
Disposal of surplus earth/excavated earth/moorum/building demolished rubbish/ malba/APP/plastic felt similar unserviceable, dismantled or waste material of partitions,ceiling boards,tiles,frames etc by mechanical transport including loading, transporting, unloading in all lifts/loads upt 10 km distance from HAL etc., all complete as directed by Engineer-In-Charge .
Supplying, mixing and placing plain cement concrete (1:3:6) of required thickness using 20mm down graded hard stone/granite aggregate in accordance with IS 456 in foundations, mass concrete, sub bases and other similar works including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing, etc., all complete as directed by Engineer-In-Charge .
Supplying, mixing and placing plain cement concrete (1:2:4) of required thickness using 20 mm nominal size down graded hard stone/granite aggregate in accordance with IS 456 in Floor leveling/ lacing courses,coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor,plinth etc including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing etc., all complete as directed by Engineer-In-Charge .
Supplying, mixing and placing plain cement concrete (1:2:4) upto 40mm thikness using 20 mm nominal size down graded hard stone/granite aggregate in accordance with IS 456 at terrace roof slab inluding leveling/ lacing etc including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., all complete as directed by Engineer-In-Charge .
Providing and laying in position ready mixed or site batched M25 Grade with minimum cement content of 330 kg/m3 design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, consolidation, levelling, curing, scaffolding, all materials, labour, carriage for all leads & lifts; but excluding the cost of centering, shuttering, finishing and reinforcement etc., all complete as directed by Engineer-In-Charge .
All works above plinth level column,beams,slabs,canopy,chajja,stairscase etc. level including necessary openings and packing if any for laying pipes, cables etc.
Supplying, straightening, fabricating (cutting & bending), placing in position and binding steel reinforcement of TMT bars of not less than Fe 500 D conforming to IS 1786 for all concrete reinforcment members / works above/below plinth level, including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.9 mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it etc., complete all as per specifications, drawings etc., all complete as directed by Engineer-In-Charge . Note : a) Only authorized laps, chairs etc. shall be considered for measurement. b) The exposed Reinforcement bars shall be coated with cement slurry.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge etc., all complete as directed by Engineer-In-Charge .
Providing and fixing M.S. grills with made of M.S. flats, square or round bars to suitable openings of required pattern/ frames with rawl plugs screwsas per site requirement only etc. including priming coat with approved steel primer etc., all complete as directed by Engineer-In-Charge .
Formwork by providing timber, wooden planks, runners / M.S. sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including M.S. bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete etc as per drawing etc., all complete as directed by Engineer-In-Charge . Note :Formwork material is contractor's own property and shall be removed after completion of work.
Foundations, footings, bases of columns/pedestal,for mass concrete etc.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Supply and Construction of Sized stone masonary works with CM(1:6) in foundation and plinth by placing the stones in layers including bonded stones as per standard ,packing,leveling,curing and finishing the joint etc., all complete as directed by Engineer-In-Charge .
Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approved manufacturer in foundation,plinth and for walls,chambers,ducts,drains etc at all levels & heights using C:M(1:6) including hoisting and setting in position and along with necessary formwork, curing, finishing, making or leaving holes & chases and making making horizontal and vertical grooves 10 mm wide 12 mm deep before plastering all complete etc., all complete as directed by Engineer-In-Charge .
Providing and laying factory made Precast concrete solid blocks of 100 mm thickness of grade M10 made of C&D waste from approved manufacturer in plinth and for walls,chambers,ducts,drains etc at all levels & heights using C:M(1:4) including hoisting and setting in position and along with necessary formwork, curing, finishing, making or leaving holes & chases and making making horizontal and vertical grooves 10 mm wide 12 mm deep before plastering etc., all complete as directed by Engineer-In-Charge .
Repair to plaster of thickness 12mm to 20 mm in patches of area lesser than 2.5 sqm including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, without causing hindrance /protecting the existing floor finish work etc., all complete as directed by Engineer-In-Charge .
Plastering to internal brick/block wall with 15 mm thick on the rough side of single or half brick wall of cemnet mortor (1:6) including leveling,curing and making the level smooth and at all heights, plaster drip course/ groove in plastered surface or moulding to R.C.C. projections and execute the work etc., all complete as directed by Engineer-In-Charge .
Plastering to ceiling with 12 mm thick on the rough side with cemnet mortor (1:4) including leveling,curing and making the level smooth and at all heights and execute the work etc., all complete as directed by Engineer-In-Charge .
Plastering to external brick/block wall with 18 mm cement plaster in two coats under layer 12 mm thick cement plaster on the rough side with cement mortor 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).including leveling,curing and making the level smooth and at all heights, plaster drip course/ groove in plastered surface or moulding to R.C.C. projections and execute the work etc., all complete as directed by Engineer-In-Charge .
Providing and applying internal wall and ceiling painting with two coats of premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50grams/ litre after applying white cement based putty of average thickness 1mm over the plastered wall,ceilings/existing surface including preparation of the surfces by scrapping existing paint/stains, with a coat of low VOC primer with emery paper to bring to smooth and even including applying additional coats wherever required to achieve even shade and colour of approved brand etc., all complete as directed by Engineer-In-Charge .
Providing and finishing old walls in two or more coats with Acrylic Smooth exterior paint with Silicone additives of approved brand of required shade @ 1.43 ltr/ 10 sqm over existing cement paint surface after Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc., all complete as directed by Engineer-In-Charge .
Providing and Finishing walls with Acrylic Smooth exterior paint of required shade for New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including scrapping,preparationof surface for etc., all complete as directed by Engineer-In-Charge .
Providing and applying synthetic enamel paint of approved brand and manufacture of required colour to give an even shade in One or more coats on new work/old by cleaning and srcapping to make the surface smooth before appling paint etc., all complete as directed by Engineer-In-Charge .
Providing, fabricating and fixing aluminium work for partitions,Curtain wall frames, flats, covers, Ventilators, Windows, louvers, doors, etc frame work.,(Min. thickness of powder coating 50 microns) made up of aluminium extruded sections,Ventilators: conforming to designaton 63400 of IS 1285 and of approved make, Sliding Window Frame: Top and side sections of the frame s to accomodate the shutter section. d) Bottom section of the frame shall be with gutter and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, e) Shutters are to be provided with galss of approved size for two shutters and stainless steel fly proof mesh for one shutter fixed with good quality tapered aluminium interlocking screwless snap on type glazing clip not less than 0.9 mm thick. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,Panelling,fly proof mesh will be paid seperately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) along with EPDM rubber / neoprene gasket etc. all complete as per the architectural drawings etc., all complete as directed by Engineer-In-Charge .
Aluminium work for shutters of doors, windows,Sliding i.e Powder coated aluminium windows (minimum thickness of powder coating 50 micron) & ventilators in moving position including providing and fixing hinges/ pivots,tracks,channels,wheels and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required including necessary accessories, all complete as per the architectural drawings etc., all complete as directed by Engineer-In-Charge .
Providing and fixing 12mm thick Pre-laminated particle board with decorative lamination on both sides, Grade I, Type Il, 1S:12823 marked in alluminumdoors, glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts to be measured), all complete as per the architectural drawings etc., all complete as directed by Engineer-In-Charge .
Providing and fixing Second Class Teak wood for frames of doors, windows, hand rails, frame work for partitions in etc, cut to shape and required curvature with polishing fixed in position with hold fast lugs/with dash fasteners of required dia & length/SS Screws at all heights,with necessary moisture content test etc., all complete as directed by Engineer-In-Charge .
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame etc., all complete as directed by Engineer-In-Charge .
Providing and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856 of approved brand/type etc., all complete as directed by Engineer-In-Charge .
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) etc., all complete as directed by Engineer-In-Charge .
Providing and fixing 35mm thick flush door shutters conforming to IS :2202 (Part I) non-decorative type of approved brand/make, core of block board construction with frame of 1st class hard wood & lipping with 2nd class teak wood battens 25 mm minimum depth on all edges and well matched commercial 3ply veneering with vertical grains or cross bands including ISI marked Stainless Steel butt hinges with necessary screws and polish veneers on both faces of shutters and making rectangular vision panel of 0.1sqm with 6 mm thick clear heat strengthened glass etc., all complete as directed by Engineer-In-Charge.
Providing and fixing panelling minimum 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm) for UPVC/wooden doors shuttres,windows,ventilators and clerestory window,including cutting and finishing as per site requirement etc., all complete as directed by Engineer-In-Charge . Note: Only visible glazing area will be considered for payment.
Providing and fixing bright finished brass handles of 125mm size with screws etc., all complete as directed by Engineer-In-Charge .
Providing and fixing bright finished brass hanging type floor door stopper with necessary screwsetc., all complete as directed by Engineer-In-Charge .
Providing and fixing bright finished brass tower bolts of 250x10mm (barrel type) with necessary screws etc., all complete as directed by Engineer-In-Charge .
Providing and fixing bright finished brass 100 mm mortice latch and lock with min. 4levers and a pair of lever handles of approved quality with necessary screws etc., all complete as directed by Engineer-In-Charge .
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc., all complete as directed by Engineer-In-Charge .
Providing and fixing aluminium sliding door bolts(aldrop) of 250 x16mm , ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc., all complete as directed by Engineer-In-Charge .
Providing and fixing Granite stone slab of with (18mm to 25mm thick), area of slab not less than 0.5sqm, like Ruby Red/Black/Cherry with gang saw cut, mirror polished, premoulded and prepolished, machine cut for platforms, vanity counters, and similar types of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc., all complete as directed by Engineer-In-Charge.
Providing and fixing Ceramic wall/glazed tiles(Light/dark shade) conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black , in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade of any size as approved by Engineer-in-Charge.
Providing and laying Glazed /Matt/Antiskid finish tile of Size 600 X 600mm or nearest available size as indicated below for Paper Joint in different sizes ( Thickness to be sepcified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.3 Kg/Sqm including grouting the joints with white cement and matching pigments etc. all, complete as per instructions of Engineer Incharge.
Providing and laying Double Charged vitrified floor tiles polished finish size of tile Size of 600 X 600 mm or nearest available size in floors over a screed of cement mortar (1:4) 20 mm thick for Paper Joint ( Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.3 Kg/Sqm including grouting the joints with white cement and matching pigments etc. all, complete as directed by he Engineer in charge.
Providing and laying Vitrified tiles in Skirting/cladding over a screed of cement mortar (1:3)-Size of Tile 600x600 mm or nearest size available (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. all, complete as directed by he Engineer in charge.
Providing and laying Polished Granite stone flooring and stair case raiser/partitions/divider and steps in colour Black, Cherry/Ruby Red or Equivalent in required design and patterns, in linear as well as curvilinier portions of building as complete as per the architectural drawings/Site condition with 18mm thick stone slab or 20mm (average) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand) laid and jointed with cement slurry and pointed with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing.nosing,chamfering and making grooves etc., complete as per direction of Engineer-in-charge.
Providing and fixing Single socketed pipes of 110mm diameter unplasticised Rigid PVC water pipes conforming to IS : 13592 Type A of approved brand, on wall/floor face including bends,collars,elbows etc,jointing with/without seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion etc., complete as per direction of Engineer-in-charge.
Providing and fixing Single socketed pipes of 75mm diameter unplasticised Rigid PVC water pipes conforming to IS : 13592 Type A of approved brand, on wall/floor face including bends,collars,elbows etc, jointing with/without seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion etc., complete as per direction of Engineer-in-charge.
Providing and fixing bright finished brass hard drawn hooks(coat hooks) and eyes of 300mm size etc., complete as per direction of Engineer-in-charge.
Providing and fixing toughened glass shelf of size 600x120x5 mm with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete as per direction of Engineer-in-charge.
Providing and fixing C.P. brass toilet paper holder of approved brand and fixing with screws,raw plugs etc., complete as per direction of Engineer-in-charge.
Providing and fixing beveled edge mirror of size 600x450mm of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers etc., complete as per direction of Engineer-in-charge.
Providing and fixing Wall hung half pedestal Vitreous China Wash basin size of approx size 630x450 mm fixed with with C.I. brackets/rack bolts , single 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste coupling of standard pattern,P.V.C. waste pipe with waste fittings of 40mm dia and make it function of approved brand/make, including painting of fittings and brackets, cutting and making good the walls wherever required etc., complete as per direction of Engineer-in-charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) of approved brand with ISI marked white solid plastic seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all connecting fittings and fixtures to make it operational completely, including cutting and making good to the walls and floors wherever required etc., complete as per direction of Engineer-in-charge.
Providing and fixing 8 mm dia C.P. / S.S. Jet (Health Fuacet) with flexible tube upto 1 metre long with S.S. triangular plate on walls/Eureopean type W.C. material of approved make and quality etc., complete as per direction of Engineer-in-charge.
Providing and fixing white colour wall hung vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption approx.), having water inlet from back side, including fixing to wall with brackets embedded in cement mortar (1:3), connecting the waste pipe/waste coupling to floor trap with all necessary fittings and accessories like 32 mm dia semi-rigid PVC waste pipe(concealed in the wall) including PVC waste fittings, clamps etc all as per manufacturers specification etc., complete as per direction of Engineer-in-charge.
Providing, fixing, testing and commissioning trap ( floor trap ) of approved make with 100 mm inlet and 75 mm outlet of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors , connection with PVC soil / waste pipe, necessary 150 mm thick cement concrete (1:2:4) for embedding the trap etc., complete as per direction of Engineer-in-charge.
Constructing masonry Chamber (60x60x75cm) inside or outside (or approx. size as per site condition) , in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. etc., complete as per direction of Engineer-in-charge.
Providing and fixing 15mm nominal bore dia C.P. brass bib cock of approved quality conforming to IS:8931 as suiatbel to site conditions, etc., complete as per direction of Engineer-in-charge.
Providing and fixing Concealed Chlorinated Polyvinyl Chloride (CPVC) pipes of approved brand, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing, necessary reducers, tank adaptors etc. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and making good the walls etc as per direction of Engineer in Charge.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms(or nearest availabe size and weight) etc., complete as per direction of Engineer-in-charge..
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet connection system and overflow pipes,making it operation with final flow check to toilets etc., complete as per direction of Engineer-in-charge..
Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps and making temporary arrangements to protect/countinue ongoing service lines of other floors etc., complete as per direction of Engineer-in-charge.
100 mm diameter
150 mm diameter
Supply and Making connection of drain pipes of 100 to 250 mm diameter or sewer line with existing manhole including breaking/cutting into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with C.M 1:3 ( 1 cement : 3 caorse sand ), finished with a floating coat of neat cement and making necessary channels for the drain etc all complete as directed by the Engineer-in-Charge.
Providing and fixing mineral fibre false ceiling tiles (of approved brand/make) with 16 mm thick beveled tegular edge with (NRC 0.55 to 0.60) at all heights of size 595X595mm of approved texture,design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%,Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-In-Charge.
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/10 sqm or as specified from the standard manufaturer like Fosroc,BASF,Pidilite,Roof,sika etc. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer in-Charge. as directed and specified by the Engineer-in-Charge . Note: (i) A performance guarantee bond for 5 years on non-judicial stamp paper of appropriate value shall be given by the contractor. The 10% of completed value of this item shall be dedcuted as defect liability deposit and the same shall be returned after sucessful completion of 5 years from the date of completion of contract / project as a whole. (ii) Plan area shall be measured for payment. (iii) The quoted rate shall be for the entire work and nothing extra shall be paid on this account.
Providing and fixing factory made 3 track UPVC glazed/wire mesh windows comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of min 1.50 mm and upto 2.1 mm for Using R3 series with frame Approx. size of (98mm & above and upto 112 mm) x (40mm & above & and upto 52mm) or nearest available, both glazed and fly screen sash Approx. size of (55mm & above and upto 66mm) x (30mm & above and upto 43 mm ) or nearest available, with zinc alloy (zamak) powder coated handle on every glazed panel along with suitable locking system (touch lock, e.t.c), (Height upto 1.8m). conforming to EN: 12608 in any shape, white colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
Manufacturing, providing and fixing factory made UPVC glazed Fixed window/ Ventilator at all levels with/ without mullion/transom comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of min 1.70 mm for series R1, R2 profiles and min 2.1mm for series R3, R4 profiles with frame sizes as mentioned below, glazed, conforming to EN: 12608 in any shape, white colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc.
UPVC glazed fixed type Ventilator of Approx. size .1.5 m X 0.9m using R1 series with frame Approx. size of (33mm & above) x (35mm & above) or nearest available & mullion (33 mm & above)x (50 mm & above) or nearest available, if necessary. (Height upto 0.9 metre) Note:- The rate is including including providing & fixing Glass.
UPVC Ventilatorwith louvered & mesh of Approx. size1.5 m X 0.9 m or as per site suitable size using R1 series with frame Approx. size of (33mm & above) x (35mm & above) or nearest available & mullion (33 mm & above)x (50 mm & above) or nearest available, if necessary. (Height upto 0.9 metre) including S.S mesh for restricting bird entry, all complete as per directions of EIC. Note:- The rate is including including providing & fixing S.S mesh.
Rupees Seventy Lakh Sixty One Thousand One Hundred Ten and Seventy Six Paise Only
Supply, erection, testing & commissioning of Main LT Panel(PTTA).
Incoming
1-no 200A 415V gr 4P 36KA MCCB TM Based
Lot - 250A, 4P, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1 Set-200/5A current transformers of suitable class and VA burden for metering.
1Set - RYB indicating lamps of LED module with 6A, 230V, 10KA, SP MCB.
1Set- 6A, 230V, 10KA, SP MCB for the protection of measuring instruments.
Outgoing
4-Nos 125A 415V gr. 4P 25KA MCCB
8-Nos 63A 415V gr. 4P 10KA MCB.
Supply, erection, testing & commissioning of Sub LT Panel(PTTA).
Incoming
1-no 125A 415V gr 4P 36KA MCCB TM Based
Lot - 200A, 4P, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1 Set-125/5A current transformers of suitable class and VA burden for metering.
1Set - RYB indicating lamps of LED module with 6A, 230V, 10KA, SP MCB.
1Set- 6A, 230V, 10KA, SP MCB for the protection of measuring instruments.
Outgoing
12-Nos 32A 415V gr. 4P 10KA MCB.
Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 olt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on ousing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) as per CPWD specification
Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt)Powder coated die cast /Extruded aluminium Body including trim as per CPWD specification
Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) as per CPWD specification.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
Supply, installation, testing & commissioning of Industrial type heavy duty Exhaust Fan (1 phase) of 300mm dia,1400RPM of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
8 way (4 + 24), Horizontal Double door MCB DB
4 way (4 + 12), Horizontal Double door MCB DB
40-63 amps. ratings, FP MCB, "C" curve, 10 KA breaking capacity.
6-32 amps. ratings, SP MCB, "C" curve, 10 KA breaking capacity.
Supply, laying, testing & commissioning of following size Aluminium LT armoured power cables.
3.5CX 25 Sqmm Aluminium armoured conductor
4CX 16 Sqmm Aluminium armoured conductor
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade as required
3.5 X 25 sq. mm Al arm cable
4C X 16 sq. mm Al arm cable
Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, fan regulator, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring)
Wiring to single light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to three light point controlled by 1 No 6A, 250V gr. flush modular type SP switch complete in all respects.
Wiring to fan point controlled by 1 No. 6A, 250V gr. flush type modular SP switch including providing 1No box type GI/MS Fan hook in ceiling, 2 module type electronic five stepped speed regulator etc., complete in all respects.
Wiring to exhaust/wall mounting fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required As per CPWD Specification.
Supplying and fixing suitable size GI Box with modular plate and cover on front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required. As per CPWD Specification.
Supplying and fixing following size modules, GI box along with Modular base & cover plate for modular switches in recess etc. as required.
2 Module
Supply & fixing in flush with the wall/on wall , factory-built powder coated sheet steel enclosed using suitable angle iron frame work, 32A, 415V, 5 pin industrial Plastic plug top & socket outlet with 32A 415V 4P MCB "C" curve in sheet steel enclosure including necessary interconnections, chipping the wall and replasting to smooth finish wherever necessary complete in all respects and as directed by Engineer in charge.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required as per CPWD specification.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required
3 x 2.5 sq. mm (For lighting ckt from DB to Switch box, For 6A power Points)
3 x 4 sq. mm(For 16A /20Apower points)
Supply, Fixing, in the existing GI /PVC box as per site requirement, testing & Commissioning of 1 No. Twin RJ-11 telephone socket outlets with shutter with necessary interconnections complete as directed by Engineer-in-charge.
Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
4 pair Unarmoured 0.5mm telephone cable
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 10 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 20 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 50 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/iron structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 10 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/iron structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 20 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/ steel structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 50 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects and as directed by EIC.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20MM PVC Conduit
25MM PVC Conduit
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
450 mm width X 50 mm depth X 2.0 mm thickness
Supply, fabricating and installing of Following size perforated GI cable trays with cover including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling/fixing to the wall/RCC beam/iron structures as per site requirement complete in all respects and as directed by Engineer in charge. (Note:-M.S. angle supports will be measured separately).
200 x 50 x 2mm thick cable tray with 1.6mm thick cover.
Supply, Fixing in flush with wall/on Aluminium partition as per site condition, testing & Commissioning of 2 nos of RJ-45 modular type sockets for Data points including supply of suitable size modular type MS/PVC surface mounting box with base plates, glossy finish front covers, labelling etc., with necessary interconnections and chipping the wall, replastering to smooth finish etc., wherever required complete as directed by Engineer-in-charge.
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required as per CPWD specification
Supplying and fixing of 15U Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. As per CPWD Specification.
Earthing
Supply, providing and Fixing Cast Iron Pipe earth station confirming to IS 3043 complete with 2750mm long, 100 mm Inner Dia(ID),13mm thickness CI Pipe, with 2 part clamp made out of G I flat 50 x 6 mm continuously welded around the pipe using cast iron welding electrodes as per drawing. The cost also incudes excavation for earth pit, providing & laying homogenous mixture of charcoal lumps, salt & sand all around the pipe as per specification, supplying and fixing of RCC Collar of size 450 mm dia, 450 mm height and 50 mm thick over Cement concrete base of minimum size 150mm width & 100mm thick all around below collar shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc., supplying & fixing the label board(MS Plate of size 300mmx200mmX2mm) welding to the electrode complete as per specification, std drawing, instructions of EIC.
Supply, fixing & connecting the 50X6mm size G.I strip on wall / clamping to the existing duct wall / fixing on steel structures/ laying 2 ft. below the ground level with necessary excavation, concrete cutting & re-concreting, refilling, consolidation & levelling of soil after laying for interconnection between the earth pits and the LT & HT panels earthing & Transformer body earthing as directed by Engineer-in-charge. Note:- Excavation, concrete cutting & re concreting will be measured separately.
Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and laying of 50mm dia, PE-80, PN6 ISI marked HDPE pipe confirming to IS 4984:19955 including suitable jointing using welding as required in the excavated trench/duct/at road crossings for encasing cables complete in all respect as directed by Engineer-in-charge.
Excavation in all types of soil for Cable trench including refilling, consolidating of soil after laying the cable including ramming and levelling to smooth finish as per the Technical specifications enclosed and as directed by the Engineer-in-charge.
Demolishing Cement Concrete manually/machanical means including disposal of material within 50 metres lead as per direction of Engineer in charge
Re-concreting the cut portion/closing the dummy cable duct at same area with 1:2:4 cement concrete by employing 20mm graded aggregate granite to smooth finish including curing and form work if any complete in all respects and as directed. As per CPWD Specification.
Design, Fabrication, Supply and fixing/grouting/welding on wall/ceiling/ truss of suitable size MS angle iron supports/ flat/ brackets for cable tray supports, as per site requirement and painting the same with two coats of synthetic enamel paint over a coat of zinc chromite primer complete in all respects and as directed by EIC/OIC.
Rupees Twenty Lakh Thirty Eight Thousand Three Hundred Ninety Seven and Sixty One Paise Only
Two Loop Panel.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
Supplying, installation, testing & commissioning of fault isolator complete with base as required
Supplying, installation, testing & commissioning of addressable fire control module complete as required
Supply, Installation, testing and commissioning of Auto Dailer including the cost of mounting accessories with addressable control module integrated with main fire alarm panel with minimum 10 telephone nos. connectivity complete as directed by Engineer-in-charge.
Supplying & laying of 2x1.5 sqmm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Rupees Four Lakh Thirty Seven Thousand Fourteen and Forty Seven Paise Only
Rupees Ninety Five Lakh Thirty Six Thousand Five Hundred Twenty Two and Eighty Five Paise Only
Approximate Amount Put to Tender
Rupees Seventeen Lakh Sixteen Thousand Five Hundred Seventy Four and Eleven Paise Only
Rupees One Crore Twelve Lakh Fifty Three Thousand Ninety Six and Ninety Six Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
TN38.pdf
pdf • 0.64 MB
40TBF.pdf
pdf • 4.65 MB
40PQF.pdf
pdf • 0.20 MB
40PBF.pdf
pdf • 0.65 MB
Civiltenderdrawings.pdf
pdf • 0.56 MB
Electricaltenderdrawings.pdf
pdf • 1.05 MB
40ECSForm.pdf
pdf • 0.48 MB
40UNDERTAKING.pdf
pdf • 0.57 MB
40CHECKLIST.pdf
pdf • 0.19 MB
40PQ.xlsm
xlsm • 0.03 MB
40PB.xlsm
xlsm • 0.53 MB
AMD25092026.pdf
pdf • 0.09 MB
Amd02A5340.pdf
pdf • 0.09 MB
AMD11092026.pdf
pdf • 0.08 MB
40EMDWAIVEDOFF.pdf
pdf • 0.16 MB
AMD04092026.pdf
pdf • 0.09 MB
R40AMD.pdf
pdf • 0.08 MB
AMDR40.pdf
pdf • 0.08 MB
AMD14082026.pdf
pdf • 0.09 MB
AMD07082026.pdf
pdf • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .