Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹11,050
Closing Date
3 Aug 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE CDC TANGEDCO
A-10, THIRU.VI.KA.INDUSTRIAL ESTATE, GUINDY, CHENNAI-600 032.
Providing electrification of control room building at Guindy 33/11 KV Indoor SS
2020_EB_172556_1
OTNO5/2020-21
Open Tender
Electrical Works
Item Rate
21 days
Guindy
As per BQR
3 documents required · 3 mandatory
₹0
₹11,050
Yes
14 Aug 2020
22 Jul 2020
4 Aug 2020
22 Jul 2020
3 Aug 2020
22 Jul 2020
180 days
Amount
Supplying and providing wiring for lights, fans,Duct lights etc., using with 2.5 sq.mm PVC insulated copper wire for phase and neutral and 1.5 sq.mm PVC insulated copper wire for looped earthing in 25mm rigid conduit .PVC casing not less than 25mm width and 2mm thickness of with necessary bends, Supplying and fixing of 5 / 15 Amps flush type switches fixed in a suitable GI anodised box with Hylem/ Sunmica sheet cover. The switch box of normal size 12"x8"x3" should be used. 1. 18W LED 4ft wall mounted light (with terrace) = 31 Nos 2. 1200mm (48") AC ceiling fan = 17 Nos 3. Surface Mounted LED 36W 2x2 = 12 Nos 4. 300mm (12") dia AC Exhaust fan = 2 Nos 5. 450mm (18") dia AC Exhaust fan = 6 Nos 6. 100W Board light = 2 Nos 7. Decorative light = 2 Nos. 8. 120W LED Yard light = 17 Nos 9. Gate light = 4 Nos 10.Street light fitting (70W) = 12 Nos 11.Head room light = 1 No.
Supplying and providing wiring for duct lights and additional heater point using with 2.5 sq.mm PVC insulated copper wire for phase ansneutral and 1.5 sq.mm PVC insulated copper wire for looped earthing in 25mm rigid conduit GI pipe not less than 25mm width and 2mm thickness of with necesary bends supplying and fixing of 5/15 amps flush type switches fixed in a suitable GI anodized box with hylem/sunmica sheet cover, the switch box of normal size 12"x8"x3" should be used. 1. Bulk Head Fitting 10W LED light = 14 Nos 2. Additional heater lamp = 6 Nos
Supplying and providing wiring 5amp plug point using two runs of 2.5 sq.mm PVC insulated copper conductor along with 1.5 sq.mm copper wire for earthing and also including 5amps two in one socket controlled by 5amp flush type switch on suitable Switch Box and connections.
Supplying of switch board and wiring 5 runs of 4sq.mm PVC insulated copper wire (phase and neutral) and also for earthing and connection with 15Amps switch and socket combined with 15 Amps plug and 4P 63A MCV with encloser size for Battery point . This includes cost of materials and labour charges.
Supplying and providing wiring to Motor Room Points from motor to starter switch boxes using 2 runs of 4 sq.mm PVC insulated copper wire along with 1.5 sq.mm PVC casing/PVC pipe not less than 25mm width with 2mm wall thickness including cost of materials, labour charges, switch board of size 18"x12"x3" with 16 Amps doublepole main switch and providing sufficient pace of providing and connections
Supplying and providing wiring with 2 runs of 4 sq.mm PVC insulated copper wire alongwith 1.5 sq.mm PVC insulatd copper wire for earthing inside the PVC rigid conduit not less than 25mm width and 2mm thickness for running circuit main from DB to all Switch Boxes, motors and inverter. Neutral should not be looped.Neutral in black and earthing in green to be followed.
Supplying and fixing, testing & commissioning of Wall mounted LED 18W LED 4' with necessary connections etc., of suitable for control room
Supplying and fixing, testing & commissioning of 1200mm (48") AC ceiling fan complete set with electronic regulator and suitable down rod at 3 mts above floor level with connections etc.,
Supplying and fixing, testing & commissioning of Mirror optical surface mounted light fitting with 2x2 36W LED Luminaire Lamp and necessary fixing accessories of standard make and connections.
Supplying and fixing, testing & commissioning of 300mm (18)" dia AC Exhaust Fan including wall bracket and accessories of standard make fixed on the wall and connections.
Supplying and fixing, testing & commissioning of 450mm (18)" dia AC Exhaust Fan including wall bracket and accessories of standard make fixed on the wall and connections.
Supplying and fixing, testing & commissioning of Bulk head fitting with guard and 10W LED Bulb for duct lighting with necessary connections etc.,
Supplying and fixing, testing & commissioning of 100W Board light fittings
Supplying and fixing,testing & comissioning of Gate light of post top lantern fittings of sylindrical of conical type suitable for 25W LED with necessary connections etc.,
Supplying and fixing,testing & comissioning of Light fitting with 12W LED Decorative Ceiling Light and necessary fixing accessories of standard make and connections
Supplying and fixing, testing & commissioning of 24W LED Street Light Fittings.
Supplying and fixing, testing & commissioning of head room light Fittings.
Supplying and fixing,testing & comissioning of with 120W LED light fitting
Supplying and fixing,testing & comissioning of earth electrode as per specification. 1.40mm GI Earth Pipe =3 mts 2.600x450x25mm RCC ring with cover =1 No 3.Charcoal =15kgs 4.Salt =10 kgs 5.Bentonite powder =50 Kgs
Bulb Additional Heater Incandescent 500 Watts
GST for bidders within TamilNadu
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .