Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC 401 7 32 CIVIL LINES ROORKEE HARIDWAR UP 247 667 | ROORKEE | HARIDWAR | UP | 247667 | ₹3.5 Cr Quoted ₹3.9 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹4.0 Cr+₹8.6 L (2.20%)Rejected-Finance | ₹4.0 Cr+₹8.6 L (2.20%) | L2 | Rejected-Finance NOT THE LOWEST |
| 3 | L3₹4.6 Cr+₹69.4 L (17.8%)Rejected-Finance | ₹4.6 Cr+₹69.4 L (17.8%) | L3 | Rejected-Finance NOT THE LOWEST |
| 4 | L4₹5.2 Cr+₹1.3 Cr (33.0%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹5.2 Cr+₹1.3 Cr (33.0%) | L4 | Rejected-Finance NOT THE LOWEST |
| 5 | L5₹6.0 Cr+₹2.1 Cr (53.2%)Rejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | NEW DELHI | DELHI | 110019 | ₹6.0 Cr+₹2.1 Cr (53.2%) | L5 | Rejected-Finance NOT THE LOWEST |
Tender Value
₹4 Cr
EMD Value
₹4.8 L
Closing Date
9 Jan 2020, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF DEFICIENT OTM ACCN FOR HBTC MARVE MUMBAI
2019_MES_297694_2
84471E8
Open Tender
Civil Works
Lump-sum
450 days
GE NORTH MUMBAI
AS PER NIT
7 documents required · 7 mandatory
₹2,000
GE( North) Mumbai
₹4.8 L
Yes
27 Jan 2020
18 Dec 2019
11 Jan 2020
18 Dec 2019
9 Jan 2020
26 Dec 2019
19 Dec 2019 - 25 Dec 2019
Amount
NOTE: Schedule ‘A’ Part I(B), II to XI are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only.
Total amount of Sch 'A' Part-I(B) (Building Works)
Total amount of Sch 'A' Part-II (Internal water Supply)
Total amount of Sch ‘A’ Part III (Internal Electrification)
Total amount of Sch ‘A’ Part IV (External Water Supply)
Total amount of Sch ‘A’ Part V (External Electrification)
Total amount of Sch 'A' Part-VI (Road, path & culverts)
Total amount of Sch ‘A’ Part VII (Sewage Disposal)
Total amount of Sch 'A' Part-VIII (Wall / Fencing / Gate / Renovation of existing wall)
Total amount of Sch 'A' Part-IX- (Site Clearance, Excavation & Earthwork)
Total amount of Sch ‘A’ Part X (Water Heater Appliances)
Total amount of Sch 'A' Part-XI (Demolition of building)
SCHEDULE PART - I (A) (BUILDING WORKS- PARTLY COMPLETED BY THE DEFAULTING CONTRACTOR)
Construction & Completion of left over work of Single Living Accommodation for 40 OR's complete all as shown on drawing and as specified. Note:- Amount of left over work shall be worked out by the tenderer based on actual measurements indicated in Appendix A1, Annexure- 1, as per detailed drawings attached & as specified.
Construction & Completion of left over work of Single Living Accommodation for officers (LT / CAPT) Block of 10 Qtrs complete all as shown on drawing and as specified. Note:- Amount of left over work shall be worked out by the tenderer based on actual measurements indicated in Appendix A1, Annexure- 2, as per detailed drawings attached & as specified.
Construction & Completion of left over work of Vehicles and Ancillaries Storage accomodation complete all as shown on drawing and as specified. Note:- Amount of left over work shall be worked out by the tenderer based on actual measurements indicated in Appendix A1, Annexure- 3, as per detailed drawings attached & as specified.
Construction & Completion of left over work of Garrage for 04 Nos ASLV 7.5 Ton complete all as shown on drawing and as specified.. Note:- Amount of left over work shall be worked out by the tenderer based on actual measurements indicated in Appendix A1, Annexure- 4, as per detailed drawings attached & as specified.
Construction & Completion of left over work of Garrage for 04 Nos ASLV 2.5 Ton complete all as shown on drawing and as specified. Note:- Amount of left over work shall be worked out by the tenderer based on actual measurements indicated in Appendix A1, Annexure- 5, as per detailed drawings attached & as specified.
Construction & Completion of left over work of Garrage for 03 Nos Gypsy complete all as shown on drawing and as specified. Note:- Amount of left over work shall be worked out by the tenderer based on actual measurements indicated in Appendix A1, Annexure- 6, as per detailed drawings attached & as specified.
Note for Sl Item No 2.21 to 2.26 : Lumpsum quoted by the tenderer against these BOQ Items shall be deemed to include for rectification of defects mentioned in Appx F attached herein after.
SCH 'A PART XII (Miscllaneous Items) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
INTERNAL ELECTRIC SUPPLY
Supply & fix LED street light fittings, 30 Watts, 230 Volts energy saver, pressure die-cast housing with epoxy powder coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses, IP 65, complete with all accessories, with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fittings, CAT PART NO 169785 BCLST 30W LED of BAJAJ or equivalent model in Crompton Greaves / Philips / Havells / Wipro, complete all as specified and directed.
Supply & fix LED tube light fitting, 22 watt, 230 volts, energy saver, indoor domestic plastic extruded luminaire with decorative end caps, complete with all accessories & ballast with diffusers complete, with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fittings, CAT PART NO LHEWEBP6PL1W022 of Havells or equivalent model in Crompton Greaves /Bajaj / Philips / Wipro, complete all as specified and directed.
Supply & fix Single phase, AC, static energy meter of accuracy class 1.0, 240 volts, 50 Hz with bakelite LCD display of rating 5 - 30 Amps (measures & displays KWH, V, Current I, KW, PF last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power, with transparent hinge type box, complete all as specified and directed.
Supply and fix ceiling fan 5 star rating, BEE mark (with and including assembling the same) with fan hook / box, 1200 mm (48") sweep and connecitng up complete with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan suitable on working AC, SP 230 V electric supply including connecting complete all as specified and directed.
S&F LED lamp 9 watts, 230 volts, White of CAT PART NO LTHPLEDLAMP9W / B22 of HPL or equivalent model in Crompton Greaves / Bajaj / Havells / Philips, complete all as specified and directed.
S&F MCB, Single pole and neutral, 240 volts, 6 to 32 Amps, 10 KA, 'B' Series, complete all as specified and as directed at site.
S&F MCB, Single pole and neutral, 240 volts, 63 Amps, 10 KA, 'B' Series, complete all as specified and as directed at site.
S&F MCB, Single pole, 240 volts, 6 to 32 Amps, 10 KA, 'B' Series, complete all as specified and as directed at site.
S&F Blanking plates of PVC, complete all as specified and as directed at site.
S&F exhaust fan, single phase, heavy duty, PVC Frame, 225 mm sweep, 1400 RPM including fixing of mounting frame in the round hole cutitng in the wall by means of rugged bolts, nuts and washers etc including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of exhaust fan complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion, complete all as specified and as directed. Note : GI earth wire & GI pipe for encasing GI wire beyond 7.50m length per earthing, if so required, at site shall be measured & paid separately
EXTERNAL WATER SUPPLY & FOUNTAIN
M & L for cutting existing 25 mm to 80 mm dia bore, Galvanised iron steel water tubing for alterations or additions, in position for insertion of & INCLUDING NEW TEE WITH UNION of size 25 mm to 80 mm, for taking out new branch connection, complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Supply, laying, jointing, testing & commissioning LT Cables, 1100 volts grade, XLPE insulated, armoured & PVC sheathed with stranded aluminium conductor, heavy duty conforming to IS 1554 Part I, ISI marked to be laid in trenches fixed along the poles or drawn through GI pipes laid under floors, road etc fixed concealed in walls, encased in GI pipe of following sizes complete all as specified and directed.
(a)2 core x 10 sqmm
(b) 4 core x 10 sqmm
(c) 4 core x 16 sqmm
(d) 3.5 core x 25 sqmm
(e) 3.5 core x 35 sqmm
(f) 3.5 core x 50 sqmm
(g) 3.5 core x 70 sqmm
(h) 3.5 core x 95 sqmm
Supply & Fix Cable route indicator made out of MS plate of size 10 cm dia and 1 cm thick, fixed on 40 mm x 40 mm x 3 mm thick MS angle iron, 0.75 metre long and embedded in and including PCC 1:3:6 type C1 (using 20 mm graded stone aggregates), concrete foundation of size 30 cm x 30 cm x 45 cm depth, complete all as specified and directed.
Supply and fix LT junction box for street light, FRP type with hinged type door and locking arrangement, including 6 Amps MCB SP, 01 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs including fixing arrangements, complete all as specified and as directed. Make: Sintex or equivalent as approvd by GE.
M & L for GI Bracket of 40 mm dia, 1.60 mtr long, bent to shape as required for fixing of street light fitting, including GI Clamps, nuts, bolts, washers, complete all as specified and as directed
S&F Timer switch, 250 V, single phase of 20 A rating wih contactor type ML - 2, fitted inside steel enclosure, complete all as specified and as directed
Supply and fixing LED street light fitting 45 Watt capacity with Pressure die cast aluminium housing with heat resistant toughened glass & IP66 protection comprising of High power LEDs of Make : Crompton Greaves Cat No NEXUS + LSTO - 45 - CDL or equivalant model in Havells/ Philips / Wipro, complete all as specified and as directed
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised iron strip of size 32 mm x 6 mm, by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion, complete all as specified and as directed. Note : GI earth strip & GI pipe for encasing GI wire beyond 7.50m length per earthing, if so required, at site shall be measured & paid separately
Supply, fabricating, Installing, Testing & Commissioning factory made, CPRI approved, Outdoor type, dust & vermin proof, LT Feeder Pillar box, cubical & compartmentalised design, made of 3.15 mm CRCA sheet for outer side & 2 mm CRCA sheet for inner side, duly powder coated, self supporting, compartmentalised design, totally enclosed, dust and vermin proof, suitable for 440 Volt 3 phase 4 wire system, having front double hinged detachable doors with neoprence rubber gasket including danger plate, earthing strip point at rear side, ventilation louvers, bottom detachable gland plate complete, the panel to be mounted on angle iron frame with legs of size 50 mm x 50 mm x 6 mm thick, at height of 60 cm from ground level grouted in and including PCC 1:2:4 type B1 (using 20 mm graded aggregates), using foundation Bolts Foundation of size 1.00 m x 1.00 m x 0.45 m and comprising of the following components:
(a) MCCB 4 pole, 150 Amps 16 KA, 415 - 1 No (Incoming)
(b) MCCB 3 pole, 100 Amps, 16 KA, 415 Volts - 02 Nos
(c) MCCB 3 pole, 63 Amps, 16 KA, 415 Volts - 03 Nos
(d) Phase Indicating lamps
(e) Aluminium bus bar, 04 Nos of rating 200 Amps capacity mounted on epoxy insulators.
(f) Internal electric connections with suitable copper conductor cable glands, lugs, thimble complete.
(g) Isolator TPN 32 Amps - 06 Nos
Note:- All incoming and outgoing MCCB compartment shall be front side operated.
WALL / FENCING / GATE / BARBED WIRE FENCING / RENOVATION OF EXISTING WALL
Supply and Fix Galvanised concertina coil fencing of dia 600 mm having 80 loops per 9 meter length, 2.5 mm + 0.1 mm dia spring core wire of high tensile strength of 1500 mPa (160 kg / sqm) with tape of width 20 mm including reinforcing flange of 8 mm thick x 0.6 + 0.05 mm thick and minimum 3 clips per loop tying with angle iron post using Galvanised wire etc., complete all as specified and as directed.
COOLING APPLIANCES
Supply, install and commissioning of water cooler 40 / 40 litres capacity, partially stainless steel, electric driven, single phase having approximate storage and nominal cooling capacity, complete all as specified and as directed.
pal construction
SHELDON CONSTRUCTION
Vishal Builders
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .