Executive Engineer Electrical Division Sivagangai
Executive Engineer PWD Electrical Division Sivagangai
Supply and fixing of Split type Airconditioner units to theTHAEI Ward Doctors room in Government Medical College Hospital at Virudhunagar in Virudhunagar District
2026_PWD_712818_1
05EE Electrical Division Sivagangai 2026 2027 Dt 06.10.2026
Open Tender
Electrical Works
Lump-sum
60 days
Govet Medical College Hospital at Virudhunagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1,100
10 Oct 2026
10 Oct 2026
27 Oct 2026
10 Oct 2026
26 Oct 2026
10 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Renewal by Supply and errection of 1.5 Ton 3STAR rated Split type Airconditioners ) GI sheet (ABS, HIPS plastic Fitted with rotary compressors operating refrigerant R-22/non CFC suitable (for floor mounting and ceiling mounting) confiriming to IS 1391 (part2) 92 (AMDT .1)(except power consumption Norms) suitable,operation on 230V,50HZ single phase AC supply. 1.Mounting/ Fitting Indoor and Outdoor units at the respective locations.. 2. Laying refrigerant pipeline of required length not exceeding 4 metres distance and connecting both units after drilling hole/holes in the wall, if required. Thickness of copper tubing shall not be less than 0.7mm 3. Insulating the suction pipe with expanded polyethelene foam 5mm tubing. 4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit. 5. Leakage testing the entire system. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units upto 4 metres length and upto switch within 3 metres of location of indoor unit. (Carrier/Voltas/Blue star make only) | 2 | No | - | - |
| 2 | Supply and fixing of 4KVA Electronic Automatic voltage Stabilizer V-Guard make model SMART - TECH VND 500 15A / 150 - 285V / Equivalent output range 150 -285 V with high and low voltage cut of and 3 minutes time delay. | 2 | No | - | - |
| 3 | Renewal by supply and laying of 5/8" and 3/8" copper refrigerant pipes of 0.8mm thick with 2.5 sqmm 3 core copper chord complete between indoor and outdoor units. ( Extra beyond 3 mts / AC unit. (For split AC unit) | 7 | Mtr | - | - |
| 4 | Renewal by supply and fixing of MS stand for fixing Spilt Airconditioner Outdoor Unit. | 2 | No | - | - |
| 5 | Gst @ 18 % | 1 | No | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.83 MB
BOQ_856204.xls
BOQ • 0.41 MB
Tendercondition19.pdf
Tender Documents • 0.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .