| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.3 LAccepted-AOC R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | ₹6.3 L Quoted ₹6.4 L | 1 | Accepted-AOC BEING THE LOWEST BIDDER |
| 2 | 2₹7.8 L+₹1.3 L (20.6%)Rejected-Finance C O HOUSE NO 16 RAGHUNATH PURA JAMMU J K | ₹7.8 L+₹1.3 L (20.6%) | 2 | Rejected-Finance BEING NOT LOWEST BIDDER |
| 3 | 3₹8.5 L+₹2.0 L (31.2%)Rejected-Finance SHAMSHU COMPLEX FORT ROAD LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | ₹8.5 L+₹2.0 L (31.2%) | 3 | Rejected-Finance BEING NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S MANU ENGINEERS AND CONTRACTORS L2 | M/S INDUS HIMALAYAN EXPLORERS L3 | M/S ZTECH L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. | 70 | Per point | 7 ₹490 | 10 ₹700 | 5 ₹350 Lowest |
| 2.00 | Taking out old unsv Service wiring of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge. | 60 | RM | 7 ₹420 Lowest | 10 ₹600 | 10 ₹600 |
| 3.00 | Supply and laying or fixing or passing through pipe, 16sq mm 2core 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 2 CORE nominal cross section in service connections complete all as specified and directed by Engr-in-Char | 60 | RM | 150 ₹9,000 Lowest | 150 ₹9,000 Lowest | 150 ₹9,000 Lowest |
| 4.00 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(a) One light point/one fan point controlled by one switch | 37 | Per point | 600 ₹22,200 | 450 ₹16,650 Lowest | 600 ₹22,200 |
| 5.00 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size | 8 | Per point | 700 ₹5,600 | 520 ₹4,160 Lowest | 630 ₹5,040 |
| 6.00 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(c) One 3 pin 5 Amp socket outlet on same board with cables 2.5 sqmm size | 7 | Per point | 150 ₹1,050 | 110 ₹770 Lowest | 350 ₹2,450 |
| 7.00 | All same as per item No 5 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable complete all as specified and directed by Engr-in-Char | 18 | Per Point | 1,600 ₹28,800 | 1,200 ₹21,600 Lowest | 1,300 ₹23,400 |
| 8.00 | S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr In Charge. | 7 | Each | 110 ₹770 | 90 ₹630 Lowest | 110 ₹770 |
| 9.00 | S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr in Charge.(T-140 Cook house) | 44 | Each | 110 ₹4,840 | 90 ₹3,960 Lowest | 290 ₹12,760 |
| 10.00 | S&f Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr in Charge .(T-140 Cook house) | 8 | Each | 350 ₹2,800 | 250 ₹2,000 Lowest | 290 ₹2,320 |
Tender Value
₹9.2 L
EMD Value
₹20,000
Closing Date
18 Jul 2026, 6:00 pmClosed
AGE (I) NIMU
AGE (I) NIMU PIN-901312 c/o 56 APO
SPL REPAIR WKS TO UNDER GROUND CABLE SIZE 25 SQMM 3 PHASE 4 CORE (LENGTH 300 MTR) WITH 02 BUS BAR CHAMBER AND 02 MAIN LIGHT PANEL BOARD NEAR BLDG NO T-135 (COY OFFICE) TO BLDG NO T-140 (COOK HOUSE) INCL BLDG NO T-711 (TM LINE) OF 118 (I) INF BDE GP S
2026_MES_770971_1
AGE(I)/NIT-28/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NIMU
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) NIMU
₹20,000
31 Aug 2026
22 Jun 2026
25 Jul 2026
22 Jun 2026
18 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. | - | Per point | - | - |
| 2 | Taking out old unsv Service wiring of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge. | - | RM | - | - |
| 3 | Supply and laying or fixing or passing through pipe, 16sq mm 2core 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 2 CORE nominal cross section in service connections complete all as specified and directed by Engr-in-Char | - | RM | - | - |
| 4 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(a) One light point/one fan point controlled by one switch | - | Per point | - | - |
| 5 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size | - | Per point | - | - |
| 6 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-
(c) One 3 pin 5 Amp socket outlet on same board with cables 2.5 sqmm size | - | Per point | - | - |
| 7 | All same as per item No 5 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable complete all as specified and directed by Engr-in-Char | - | Per Point | - | - |
| 8 | S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr In Charge. | - | Each | - | - |
| 9 | S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr in Charge.(T-140 Cook house) | - | Each | - | - |
| 10 | S&f Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr in Charge .(T-140 Cook house) | - | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_863359.xls
BOQ • 0.48 MB
TENDER28.pdf
Tender Documents • 1.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .