Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.0 L+₹3.7 L (10.7%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹39.6 L+₹5.2 L (15.2%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹40.7 L+₹6.3 L (18.4%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹44.5 L+₹10.2 L (29.7%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
19 Feb 2022, 6:00 pmClosed
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Repair/ replacement of LT UG cables, earthing and allied works and repair/comprehensive maintenance of lift, dish washer machine, tower clock and misc equipment at CME
2022_MES_500159_3
8265/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D b(i)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹96,000
Yes
1 Apr 2022
5 Feb 2022
21 Feb 2022
5 Feb 2022
19 Feb 2022
6 Feb 2022
Amount
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and making good surface for laying of cable all as specified and directed by Engr in charge for following :-
Soft/loose soil
Hard/dense soil
Soft/disintegrated rock.
Returning, filling in, excavated soil in trenches, watering and well ramming in layers n exc 25 cm complete all as specified and directed.
Removal of surplus excavated spoil to distance n exc 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed
M&L for clean dry river sand cushioning to undeground cables in trenches including spreading, leaveling hand punning and consolidating complete all as specified. Note- thickness after punning down shall be measured and paid.
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 77 mm and inner dia 63 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete including taking down old unserviceable pipe all as specified and directed.
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm and inner dia 76 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete including taking down old unserviceable pipe all as specified and directed.
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete including taking down old unserviceable pipe all as specified and directed.
Supply and lay factory made, ISI marked, un-reinforced precast concrete cable cover class LV type-1, flat of size 250mmx150mmx40mm complete all as specified and directed.
M & L for bituminous road cutting to a width of 45 cm and depth 50 cm for laying of pipe for drawing of UG cables and making good with PCC (1:3:6) type CI (using 20mm grade stone aggregate) complete all as specified and directed.
M & L for PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation of poles complete all as specified and directed.
Supply , laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl using suitable clamp of cross sectional area 4 core 16 Sqmm in and including taking out old one all as specified and directed.
All as per item No. 11 above, but of the size 4 core 25 Sqmm
All as per item No. 11 above, but of the size 3.5 core 35 Sqmm
All as per item No. 11 above, but of the size 3.5 core 50 Sqmm
All as per item No. 11 above, but of the size 3.5 core 70 Sqmm
All as per item No. 11 above, but of the size 3.5 core 95 Sqmm
All as per item No. 11 above, but of the size 3.5 core 120 Sqmm
All as per item No. 11 above, but of the size 3.5 core 185 Sqmm
All as per item No. 11 above, but of the size 3.5 core 240 Sqmm
M&L for fault detection in damaged UG cables using cable fault detector/locator, vehicle mounted to accuracy of 2m for various locations inside CME for UG cables of any size & any type upto 22kv grade including excavation & earthwork in any type of strata of size 4x2x0.6m to visually inspect/repair the damaged cable when and where directed by Engr-in-charge.
Supply and fix straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 25-50 Sqmm complete all as directed by Engr-in charge.
Supply and fix straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm complete all as directed by Engr-in charge.
Supply and fix straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-185 Sqmm complete all as directed by Engr-in charge.
Supply and fix straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 240 Sqmm complete all as directed by Engr-in charge.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 4 sqmm , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old unserviceable one complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 6 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old unserviceable one complete all as specified and directed.
M&L for clearing of grass shrubs and other growing by uprooting in switchyards and installations upto 10 cms in girth at various locations as directed
Supplying and laying GI tubing light grade 80 mm dia incl all accessories for encasing cables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/ floor or along poles with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/ drilling works including taking down old tubing . all as specified and directed.
All as per item no 28 above, but size 50 mm bore
All as per item no 28 above, but size 40 mm bore
M & L for earthing complete with 600x600x60mm GI earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including GI strip of size 25x4mm by means of bolts, nuts and check nuts and washers with and including 40mm dia GI medium grade pipe for protection of strip to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part-I-2009 including chamber made up of PCC 1:2:4 type-B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing including taking down old unserviceable earthing complete all as specified and directed. Note :- GI strip more than 7.5mtr will be measured and paid separately.
M & L for spraying chemical Roundup super/topper 77 concentrates on area to remove unwanted vegitation/grass at various locations as directed. Note : (i) Labour and equipments to spray chemical on required area are incl in quoted rates. (ii) Spray will be repeated quarterly or as per direction of Engr in Charge.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof L.T feeder pillar box (approx size 1.8m x 0.1m x 1.2m) factory fabricated (panel shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x6 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on front side and fixed panel door on back side with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed to inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x6mm & the following accessories:-
Copper bus bar rectangular 2000 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01Job
ACB 1250 Amps, draw out type Icu=Ics=Icw=50kA compact dimension - 01 No (incoming)
MCCB 400 Amps, 4 pole, 415 Volts, 50 kA, thermal magnetic release adjustable type - 02 Nos (Outgoing)
MCCB 315 Amps, 4 pole, 415 Volts, 50 kA, thermal magnetic release adjustable type - 02 Nos (Outgoing)
MCCB 250 Amps, 4 pole 415 Volts, 50 Hz ,50 KA, thermal magnetic release adjustable type- 02 Nos ( Incoming)
MCCB 160 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 No ( Outgoing)
MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 No (Outgoing)
3 pole Power contactor 415 Volts, ML - 4, 70 Amps cap - 01
Digital street light timer type - 1 No
MCB SPN 40 Amps :- 03 Nos
RYB LED phase Indicator Lamp set - 01 No
Provision of cubicle as per above description to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof L.T feeder pillar box (approx size 1.5m x 0.5m x 1.0m) factory fabricated (panel shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed to inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
Copper bus bar rectangular 800 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy inulators with colour coding PVC sleeves.-01Job
MCCB 400 Amps, 4 pole 415 Volts, 50 Hz ,50 KA, thermal magnetic release adjustable type- 01 No ( Incoming)
MCCB 250 Amps, 4 pole 415 Volts, 50 Hz ,50 KA, thermal magnetic release adjustable type- 01 No (Outgoing)
MCCB 200 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 No ( Outgoing)
MCCB 160 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 No ( Outgoing)
MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 03 Nos ( Outgoing)
3 pole Power contactor 415 Volts, ML - 4, 70 Amps cap - 01
Digital street light timer type - 1 No
MCB SPN 40 Amps :- 03 Nos
RYB LED phase Indicator Lamp set - 01 No
Provision of cubicle as per above description to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof L.T feeder pillar box (approx size 1.5m x 0.5m x 1.0m) factory fabricated (panel shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed to inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
Copper bus bar rectangular 800 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01Job
MCCB 400 Amps, 4 pole 415 Volts, 50 Hz ,50 KA, thermal magnetic release adjustable type- 01 No ( Incoming)
MCCB 250 Amps, 4 pole 415 Volts, 50 Hz ,50 KA, thermal magnetic release adjustable type- 01 No ( Outgoing)
MCCB 200 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 No ( Outgoing)
MCCB 160 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 02 Nos ( Outgoing)
MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 Nos ( Outgoing)
3 pole Power contactor 415 Volts, ML - 4, 70 Amps cap - 01
Digital street light timer type - 1 No
MCB SPN 40 Amps :- 03 Nos
RYB LED phase Indicator Lamp set - 01 No
Provision of cubicle as per above description to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof L.T feeder pillar box (approx size 1m x 0.5m x 1.0m) factory fabricated (panel shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed to inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
Copper bus bar rectangular 400 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01Job
On load change over switch 250 Amps , 4 pole 415 Volts, 50 Hz - 01 No ( Incoming)
MCCB 125 Amps, 4 pole 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type- 03 No ( Outgoing)
MCCB 63 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 02 Nos ( Outgoing)
MCB SPN 40 Amps :- 03 Nos
RYB LED phase Indicator Lamp set - 01 No
Provision of cubicle as per above description to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof L.T feeder pillar box (approx size 1.2m x 0.5m x 1.0m) factory fabricated (panel shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed to inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
Copper bus bar rectangular 800 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01Job
On load change over switch 400 Amps , 4 pole 415 Volts, 50 Hz - 01 No ( Incoming)
MCCB 250 Amps, 4 pole 415 Volts, 50 Hz ,50 KA, thermal magnetic release adjustable type- 02 Nos (Outgoing)
MCCB 63 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 02 Nos ( Outgoing)
MCB SPN 40 Amps :- 03 Nos
RYB LED phase Indicator Lamp set - 01 No
Provision of cubicle as per above description to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof L.T feeder pillar box (approx size 1.1m x 0.5m x 1.0m) factory fabricated (panel shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed to inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
Copper bus bar rectangular 400 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01Job
MCCB 250 Amps, 4 pole 415 Volts, 50 Hz ,50 KA, thermal magnetic release adjustable type- 01 No (Incoming)
MCCB 63 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 04 Nos ( Outgoing)
RYB LED phase Indicator Lamp set - 01 No
Provision of cubicle as per above description to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof L.T feeder pillar box (approx size 1.2m x 0.5m x 1.0m) factory fabricated (panel shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed to inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
Copper bus bar rectangular 800 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01Job
MCCB 400 Amps, 4 pole 415 Volts, 50 Hz ,50 KA, thermal magnetic release adjustable type- 01 No ( Incoming)
MCCB 200 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 02 No ( Outgoing)
MCCB 160 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 02 Nos ( Outgoing)
MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 No ( Outgoing)
RYB LED phase Indicator Lamp set - 01 No
Provision of cubicle as per above description to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
M&L for boring holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 04 mpa working pressure complete all as specified and directed.
Disconnection & removing of all electrical/mechanical connection carefully of tower clock for repair and replacment of defective boxes, spare parts, servicing/overhauling of clock machine and gear motion including cutting, filling, grinding, turning & balancing driving shaft and adjusting the differences in all clocks with respect to each other and setting of correct time, incl labour and technician charges all as specified and directed by Engr-in-charge.
Servicing/overhauling of gear box including replacement of unsv parts of gear box, motor coupling, auxiliary gear box, gear box and motion work spindle coupling incl labour and technician charges etc all as speciified and directed.
Supply and fixing of LED strip of defective Hrs hand and minute hand of all 4 side watches (4 Hrs Hand and 4 Minute Hand) all as speciified and directed.
Supply and fixing of LED strip of Hrs nos of all 4 side watches ( Total 48 Nos) all as speciified and directed.
Supply and fixing in repairs of Hrs box made out of 3 mm thick CRCA sheet weather proof, rectangular of size 42 x 9 x5 cm with front opening, hinged door frame floor mounted, single door with locking arrangement including painting two coats with powder coated over one coat of red oxide zinc chrome primer on steel surfaces internally & externally and provision of two Nos clamps for fixing of box in wall of existing tower clock
Supply and fixing in repairs of Hrs box made out of 3 mm thick CRCA sheet weather proof, rectangular of size 52 x 12 x5 cm with front opening, hinged door frame floor mounted, single door with locking arrangement including painting two coats with powder coated over one coat of red oxide zinc chrome primer on steel surfaces internally & externally and provision of two Nos clamps for fixing of box in wall of existing tower clock
Supply and fixing in repairs of GPS antenna and module for time signal all as speciified and directed.
S&F surface and wall mounted LED batten(LED tube light fitting 20W) with polycarbonate housing & integrated electronic driver alongwith LED tube 20 watt and 02 Nos PVC square blocks incl taking down old UNSV fitting. Make- Havells cat No LUMILINEBS20WLED830SPCWH or equivalent of Philips/Bajaj/shakti
Supply and fix LED bulb 9W incl taking down old u/s lamp of any type complete all as specified and directed by Engr-in-Charge
Hiring of lifter crane with cabin up to max height 25 to 30 metre high for fixing of outer dial of tower clock to all of four sides. Note : Necessary manpower like Electrician Technician, masonry work drilling to stone, fixing of dial, all labour charges for outside work are included in quoted rate for this item.
Disconnecting the electric supply and opening of the front panel of the dish washing machine strictly as per the manufacturers instructions/guidelines for carrying out inspection of heating and conveyor mechanism for washing of utensils. (skilled technicians from authorised dealer/company rep to be employed), replacement of defective heating kit RE 8230020 (BK) & fixing of front panel, conveyor system, PCB and contactors after carrying out necessary repairs as above, testing & commissioning to the entrie satisfaction of Engr-in-Charge
Comprehensive Maintenance and servicing of Lifts (Make : OMEGA) of 08 Passangers (544 KG) at Viewers Gallery ARN CME Pune once in a month including attending faults on call basis for normal repairs including replacement of defective & worn out parts by new spares such as battery, landing header, Contactors, relays, gearless drive, ARD, DBRs, PCB etc and greasing of bearings of Lifts as directed by engineer-in Charge. [Note : i) Spares required for above maintenance will be measured and paid separately under relevant item. (ii) Servicing to be carried out as per manufacturer instruction]
Supply and fixing in repairs lift battery 12V-1.2AH-FP (Make- Exide) complete all as specified and directed
Supply and fixing in repairs lift battery 12V-7AH-FP (Make- Exide) complete all as specified and directed
Supply and fixing landing header (Witture door) complete all as specified and directed
Supply and fixing ADOM Block contactor 4 pole (Schneider) complete all as specified and directed
Supply and fixing Contactor 4 pole 3 tc 44 (Siemens) complete all as specified and directed
Supply and fixing Ply relay (24 Volt DC) complete all as specified and directed
Supply and fixing 7.5 HP gearless Drive (Fuji Electric) complete all as specified and directed
M&L for ARD elevator emergency automatic rescue device for an event of a power failure or blackout in a building (12 volt 18 amp battries and UPS of 24 watt all as specified and directed
M&L for DBR (Dynamic braking resistors) produce braking torque and absorb the high amounts of energy generated by stopping electric motors 60 watt all as specified and directed
M/S kirpan Enterprises
Pritam Electro Mechanical Services
Sachin Electricals
Mahindra Electric Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .