Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance | ₹1.9 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Mohammed Suneer L1 |
|---|---|---|---|---|
| 1.00 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as wellas 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil | 10 | Cum | 500 ₹5,000 Lowest |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 10 | Cu.m | 1,000 ₹10,000 Lowest |
| 3.00 | Disposal of earth work by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 5 km for all lifts, complete as per directions of Engineer-in-charge. | 5 | Cu.m | 1,000 ₹5,000 Lowest |
| 4.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 5 | Sqm | 2,120 ₹10,600 Lowest |
| 5.00 | Providing,diluting and injecting chemical emulsion to 12mm dia holes in Masonry/earth fiiling and plugging with cement mortar 1:2 to match the line and level of sorrounding area for PRE CONSTRUCTIONAL anti-termite treatmentwith Imidacloprid (30.50% SC) or approved equivalent. Plinth area in plan at GF shall only be measured (for all below specified steps) and paid. A guarantee bond of 10 years shall be furnished. A) Bottom surface and the sides of the excavation made for masonry foundations at the rate of 5 liters/sqm (wherever applicable) B) Top surface of the plinth filling of 5 liter/sqm of internal plinth area etc. complete. C) At the rate of 5 liter/ sqm to the internal vertical surface from original Ground level to top of the earth filled in the plinth. D) At the rate of 5 liter/ sqm to the external vertical surface below finished Ground level to the full depth of the filling complete. The work includes all costfor chemical, drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing finish etc all complete as per the direction of Engineer-In-Charge | 5 | Sq.m | 450 ₹2,250 Lowest |
| 6.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | 2 | Cu.m | 14,500 ₹29,000 Lowest |
| 7.00 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 350 kg /cum. | 5 | Cu.m | 23,232 ₹1,16,160 Lowest |
| 8.00 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M30 grade with minimum cement content of 350 kg /cum. | 2 | Cu.m | 23,456 ₹46,912 Lowest |
| 9.00 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete | 50 | Sq.m | 1,000 ₹50,000 Lowest |
| 10.00 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers | 25 | Sq.m | 1,000 ₹25,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹3.2 L
Closing Date
7 Mar 2023, 3:00 pmClosed
Executive Engineer, LPWD Kavaratti
Executive Engineer, LPWD Kavaratti
Development of Beach Front in Bangaram, U T of Lakshadweep
2023_UTL_2208_1
NIT No.91/NIT/EE Kvt/2022-23
Open Tender
Civil Works
Item Rate
30 days
Bangaram
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Executive Engineer, LPWD Kavaratti
₹3.2 L
13 Mar 2023
3 Mar 2023
7 Mar 2023
3 Mar 2023
7 Mar 2023
3 Mar 2023
Amount
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as wellas 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Disposal of earth work by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 5 km for all lifts, complete as per directions of Engineer-in-charge.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing,diluting and injecting chemical emulsion to 12mm dia holes in Masonry/earth fiiling and plugging with cement mortar 1:2 to match the line and level of sorrounding area for PRE CONSTRUCTIONAL anti-termite treatmentwith Imidacloprid (30.50% SC) or approved equivalent. Plinth area in plan at GF shall only be measured (for all below specified steps) and paid. A guarantee bond of 10 years shall be furnished. A) Bottom surface and the sides of the excavation made for masonry foundations at the rate of 5 liters/sqm (wherever applicable) B) Top surface of the plinth filling of 5 liter/sqm of internal plinth area etc. complete. C) At the rate of 5 liter/ sqm to the internal vertical surface from original Ground level to top of the earth filled in the plinth. D) At the rate of 5 liter/ sqm to the external vertical surface below finished Ground level to the full depth of the filling complete. The work includes all costfor chemical, drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing finish etc all complete as per the direction of Engineer-In-Charge
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 350 kg /cum.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M30 grade with minimum cement content of 350 kg /cum.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
15 mm cement plaster on the rough side of single or half brick wall of mix : : 1:4 (1 cement: 4 fine sand)
Providing & Fixing Gateway using Coconut poles as per the approved architectural design and 3D.
Providing & Fixing Steel Logo of 60cm dia, all complete as per the approved architectural design and 3D.
Providing and Fixing Wooden Light Pole of size 20x 20cm and 70cm ht etc, and finished with black enamel paint all complete as per the approved architectural design and 3D. The rate is including the cost of electrical items like lights-10W Bollard Lights,cables etc
Providing and Fixing Wooden Light Pole of size 20cm dia and 70cm ht etc, all complete as per the approved architectural design and 3D. The rate is including the cost of electrical items like lights-3W Outdoor LED Down Light,cables etc
Providing and Fixing Fencing of size -8' x 5' with wooden outer frames 4"x3" and intermediate pieces of Chural Bamboo horizontally arranged and supported by steel rod.The rate is inclusive of all materials and labour charges. all complete as per the approved architectural design and 3D.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer?in-charge).
Providing and laying grid paver blocks (green paver block) of thickness 75mm in path ways or yards of 600x400mm or approved size, laid in required pattern over 50mm thick compacted bed of sand/6mm aggregate, compacting and proper embedding/laying of paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling and finishing the joints with cement mortar (cm 1:4) and cutting of paver blocks as per required size and pattern,planting grass in the the open areas of paver, laying PCC 1:2:4 on edges of pavered area,sweeping and cleaning debris etc complete all as per direction of Engineer-inCharge.
Providing and laying factory made 50 mm thick Bangalore stone of 600 mm x 600 mm & 1200mm x600mm of required strength, laid in required colour & pattern over 50mm thick compacted bed of 6mm aggregates, compacting and proper embedding/laying of blocks into the aggregate layer, filling the joints with cement mortar mixed with pigment to match the shade and , finishing and sweeping extra mortar,washing etc complete all as per direction of Engineer-in?Charge.
Size 4'x2'
Size 2'x2'
Providing and fixing Stone Pillar of size 15x15x120cm on Rcc foundations 30cm thick at various locations for fixing tap. Height of pillars above GL is 90cm .The rate is exclusive of cost of tap ,Pipes,watertank & other fittings,plumbing & electrical connections etc complete.Foundation works shall be included in the relevent items.
Providing and fixing Outdoor Recreation using bamboo poles at various locations. The rate is excluding the cost of lights & outdoor seats. All complete as per the approved architectural design and 3D.
Providing and fixing Shelter using Bamboo & Choola wood. Rate is including the cost & labour for fixing the supporting wooden structures.All works complete as per the approved architectural design and 3D.
Providing and fixing Shade net shed for restaurant roof using HIPPO - HDPE Fabric ,180gsm,90% Sun Blockage .Rectangle Shade Sails With Polyester Band Reinforced Complete Protection from Sun & UV Rays. Patio Beige-Brown in Colour .Rate is including the cost & labour for fixing the supporting wooden structures .All complete as per the approved architectural design and 3D.
Providing & Fixing Name Boards of size 60x20 cm using hardwood planks.The rate includes the cost of lettering etc.All complete as per the approved architectural design and 3D.
Providing & Fixing Swing Hangings as per architectural design and 3D. The rate is inclusive of posts for fixing the hangings & other accessories etc.
Providing & Fixing Bamboo Umbrella as per architectural design and 3D. The rate is inclusive of fixing & other accessories etc.
Providing & Fixing Gateway Steel Arch with 50mm dia ms pipes bent to shape, inclusive of all hardwares etc. All complete as per the approved architectural design and 3D.The rate is excluding the cost of electrical items like Led lights,cables etc
Providing & Fixing Outdoor Shower of 1.2m inner dia using Choola wood.The flooring of the unit shall be stone finished over appropriate bedding. The rate is excluding the cost of shower ,piping & other necessary accessories etc complete
Providing and laying 20 mm thick natural wood deck flooring panels of length 0.90 mtr-2.20 mtr & Width 70/90 mm in any approved shade screwed to alumiminium chanels (50x25x2.5mm) with SS crews and clips as per the pattern/design approved by the Architect. The cost includes all materials, accessories, screws,clips, labour etc. complete as per the direction of Engineer In Charge.
Providing & Fixing portable volley ball post & net unit. The rate is inclusive of all accessories and labour charge etc complete.
Providing & Fixing fixed Football post & net unit of size 12'x8' .The rate is inclusive of all accessories and labour charge etc complete.
Supplying & Fixing Side Pole Umbrella including base with opening and closing system.Frames shall be made of aluminium and weatherproof fabrics.Make : Loom Crafts or equivalent.
Supplying of poolside lounger with cushion and adjustable settings for head positions. Frame shall be made of powder coated aluminium. Make : Loom Crafts or equivalent.
Supplying of chaise lounger right arm with cushion with powder coated aluminium framing and high density foam.Make: Loom Crafts or equivalent.
Supplying of Dining arm Chair with cushion of ,framing & legs using powder coated aluminium , covered with synthetic wicker of approved shade & colour. and high density foam cushions. Make: Loom Crafts or equivalent.
Supplying of 4seater dining unit of 100 x 100 x75 cm made up of framing with powder coated aluminium and 10mm toughened glass top ,The frames covered with synthetic wicker of approved shade & colour.
WIRING
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
MCCB, MCB & DB’S
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
CHAPTER 7-MV CABLE LAYING
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
CHAPTER 9-MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (28mm)
L.T.PANELS
External Lighting Panel (Outdoor Feeder Pillar)
Supply, installation, testing and commissioning of cubicle type totally enclosed Floor, dust free, damp and vermin proof, powder coated ,Form 4b and water proof, double door with canopy outdoor (IP 65) (IK 10) LT Panel fabricated out of GRP including supply & fixing the following items and interconnections, wiring with suitable size wires/cables and including all works for foundation like excavation, PCC, brick work , plastering, finishing etc. and as per specifications as required. Refer technical specification and drawing for details. Incomer: 32A, FP MCB Busbars: 32 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy - 1 Set INSTRUMENTS: 4A, C curve SP MCB - 3 Nos, RYB indication lamp, LED type - 1 Set, ON-OFF-TRIP indicator -1 set SPD (Surge Protection Device as Per IS/IEC 62305 Part4)- 1 Set. Outgoings:25A DP RCBO 100mA with with digital timer and contactor-4nos, 16A DP RCBO 100mA with with digital timer and contactor-3nos
SUPPLY OF LT CABLE
Supplying of following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm
3 X 2.5 sq. mm
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3 X 2.5 sq. mm
LIGHT FITTINGS / FANS
SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans
3W Single Lights in Pergola
3W Group Lights
3W Lantern Lights
3W Single Lights
50W Flood Light
80W Flood Light
LED Strip for Arch Feature
SANITARY INSTALLATIONS
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
WATER SUPPLY
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore. Make: Jaquar, Kohler, Grohe, Cera high end series.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore Make: Jaquar, Kohler, Grohe, Cera high end series.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
Providing and fixing Gun metal check or non-return fullway wheel valve. 25mm dia.
SANITARY FIXTURES
Fixing, testing and commissioning of Single Lever Diverter with provision for spout and over head shower with shower arm, shower rose, wall flange and spout, all accessories etc, complete.Queo - (Aquaplan +F Elegant)/ KOHLER K-14795IN-CP/Grohe Metropole, jaquar OR Equ.
SOIL, WASTE, VENT & RAIN WATER PIPES
Supplying, Fixing, testing and commissioning at site in position u PVC pipe of 6Kgf/cm2including PVC fittings with bosses where required e.g. tees, bends,door TEE , Door Elboe where ever required coupling and adapters and jointing with adhesive approved by fitting manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site universal clamps & anchor fasteners(8mm) , threaded rod(8mm),nuts ,washers, wherever required etc. complete.Make: Astral/Supreme/Ajay
75 mm O.D. (6Kgf/cm2 (IS:4985)
Supplying,Fixing, testing and commissioning at site in position UPvc fabricated Multi floor trap (4”), with 50/75 mm dia outlet (In Sunken slab & floor raising areas)Astral/Supreme/Ajay
Supplying,Fixing, Testing and commissioning at site in position 150x150mm square C.P cast brass or stainless steel anti cockroach grating cover ss (304) of matching size of UPvc fabricated floor trap / multi inlet trap complete in all respects. Chilly/Eligna/
PUMP AND ACCESSORIES
TERRACE DWS BOOSTER PUMP Duty Conditions of 6 lps @ 35 mtr - head(Each pump3LPS 35 mtr Head - 2 Pump system-1 Working+1standby) Compact skid mounted Booster pumps with SS 304 casing, SS316 impeller , SS316 shaft , C I base and TEFC motor with mechanical seal. Pump to be have single VFD logic controller. - Electric control panel with logic controller, relays, calibrated pressure switch, pressure transmitter including cabling within panel, incorporating dry run protection, potential contacts for BMS integrating , sucton and discharge headers, pressure vessal 60 ltr capacity.
WATER TREATEMENT PLANT
Supply, Installation, Testing & Commissioning of 2000 Lpd Water Treatment Plant for removing sulpher with Reverse Osmosis Process with all mechanical work like piping, mechanical components as follows but excluding the electrical works and civil work. a) PAC off Chlorine Dosing system -1nos,Pressure sand filter FRP-1 no ,Activated carbon filter FRP-1no,
Miscellaneous Works
Construction of Manhole chambers(Inspection chambers) 600mm X 600 mm and depth 1.0 m in brick or bela stone masonry, locally available in C. M. 1:6. Foundation concrete 150 mm thick in C. C. 1:4:8 of trap metal size 25 mm to 40 mm thick, inside cement plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and top cover of precast RCC slab 100 mm thick (with key hole in two parts, each with handles or MS Bar etc. complete as given size) Upto 1 Mt. depth from G. L. to pipe invert level incl. complete civil works but excl. cost of excavation and refilling, with cast in situ RCC slab in one single piece with fixing of CI-MH Frame and cover (incl. cost of CI-MH Frame and cover) with 23 mm thick brick masonry wall in C.M.1:6. With precast slab in two parts 15mm.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .