| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC NIL | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹39.5 L+₹84,294.04 (2.18%)Rejected-Finance | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹44.3 L+₹5.6 L (14.4%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L3 | Rejected-Finance Other than L1 bidder | |
| 4 | L4₹45.0 L+₹6.3 L (16.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 bidder | |
| 5 | L5₹48.2 L+₹9.5 L (24.6%)Rejected-Finance KALAPAHAR BIMALANAGAR GUWAHATI 781016 DISTT KAMRUP ASSAM | KAMRUP METRO | ASSAM | 781016 | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹40.6 L
EMD Value
₹81,500
Closing Date
8 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
PROVN OF GUARD ROOM ACCN WITH ATT BATHROOM AND TOILET AND PROVN OF DUTY OFFR ROOM UNDER GE GUWAHATI
2024_MES_656636_2
8767/GUW/E8
Open Tender
Civil Works
Item Rate
270 days
Guwahati
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Guwahati
₹81,500
Yes
27 Jan 2025
17 Sept 2024
10 Oct 2024
17 Sept 2024
8 Oct 2024
24 Sept 2024
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out Soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
M&L for sand filling under floor or in foundation including watering and consolidation complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion (ATT) per sqm of surface area etc complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion (ATT) per sqm of surface area etc complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion (ATT) per sqm of surface area etc complete all as specified and directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for RCC (noninal mix), type A1( 1:1.5:3) (using 20mm graded stone aggregates) as in foundations including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC (noninal mix), type A1( 1:1.5:3) (using 20 mm grade stone aggregates) as in columns, pillars, posts etc. complete all as specifiedand directed.
M&L for RCC (noninal mix),type A1( 1:1.5:3) (using 20 mm grade stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC (nominal mix) type A1( 1:1.5:3) (using 20 mm grade stone aggregates) as in chajjas etc. complete all as specified and directed.
M&L for RCC (nominal mix) type A1( 1:1.5:3) (using 20 mm grade stone aggregates) as in slab supported on walls, beams and columns as in floors, roofs, landings and similar works complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings and plinth beams etc. flat fair finished surfaces of concrete complete all as specified and directed.
M&L for formwork to sides of pillar, column etc. rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to sides and soffits floor or roof beams, lintel, cantilevers, shelves etc. flat rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to chajjas, troughs and similar items including edges flat rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to soffit of suspended slab, such as roof slab, fllor slabs, landing and similar work not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length, bent to shape reqd including cranking, bending spherically for hooping for columns, hooking ends & binding steel wires not less than 0.9mm dia with clips complete all as directed and specified.
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders complete all as directed and specified.
M&L Brick work with sub class 'B' brick, staright or curved or plain exc 6 m mean radius built in CM (1:6) complete all as specified and directed.
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius as in half brick thick walls, built in CM (1:4) complete all as specified and directed.
M&L for 20 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement mortar (1:2) complete all as specified and directed.
M&L for rendering 15 mm thick in two layers (10+5)mm externally on fair faces of brick work or concrete surfaces in cement mortar 1:4 using water proofing compound on the top 5mm layer as per manufacturer's instruction and finished the surface fair and even without using extra cement complete all as specified and directed. NOTE: Water proofing compound shall be measured and paid separately under relevant item.
Supply only Liquid Water Proofing compound complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortor 1:6 other than fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortor 1:3 on ceiling and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of exterior weather acrylic emulsion paint over a coat of exterior primer over a coat of 1.5mm thick wall care putty complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying two coats of acrylic distemper over a coat of primer complete as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement based paint over a coat of suitable primer using autoroller for making the surface uniform complete all as specified and directed.
S & F Framed work such as grill, gratings etc with ends of bars shouldered and/or riveted, frame guard bars, barred iron doors, ladders, railings: framework of watertanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and directed.
M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridges, hips, valley, gutters, eaves board fixed with self tapping screws complete all as specified and directed.
M&L for mild steel in tubular trusses/purlins/rafters/post etc. including special shape washers complete using ERW or induction butt welded turbes conforming to IS 1239 complete all as specified and directed.
M&L for rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe- 290 Gde E- 165 complete all as specified and directed.
M & L for preparation of new steel Surfaces of any description exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L for preparation of new steel Surfaces of any description n.exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Supply and fix of ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 20mm bore and fixed complete all as specified and directed.
M&L for Pressed steel frames of size 125mmx60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
M&L for 2nd class hard wood plain, solid, straight chowkhats & frames, wrought, paneled, rebated on the solid, rounded or chamfered put together with glue, pinned at joints complete all as specified and directed.
S&F of MS holdfast made up of FI 25 X 3mm conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
M&L PCC 1:3:6, Type C-1 (using 20 mm graded stone aggregate) as in bed blocks for inserting holdfast, etc including necessary form work complete as specified and directed.
S&F 35mm thick flush shutter with solid core construction with block board core and plywood face panels, decorative face veneer with lipping/frame to match on both sides complete all as specified and directed..
S&F 2nd class hard wood glazed and skeleton shutters, 35mm thick, open rebated & prepared to receive glass gauge (without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitread beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I, section 8, clause 8.24- (a), supplied and fitted to chowkats.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F of Aluminium alloy anodised sliding door bolt with hasp & staple ( bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed.
S&F butt hinges 100 mm medium weight mild steel cold rolled and fixed complete all as specified and directed.
S&F 150mm size, aluminium anodised handle, fabricated type complete all as specified and directed.
S&F of 300mm mild steel, ordinary rat tail rod pattern springs including roller and roller plate completecomplete all as specified and directed.
M & L for preparing new wood or wood based surfaces of any descriptions exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer ccomplete all as specified and directed.
S&F powder coated anodised aluminium doors/ windows/ ventilators/ partition with one or more rebates including jointing cleats for fixing etc complete with frames, shutters and grills etc including aluminium handles, tower bolts, grills etc complete all as specified and as directed. Note: (i) The design/ pattern, profile size, thickness of aluminium sections and other dimension shall be as directed by Eng-in-Charge. (ii) The use of flimsy sections shall not be permitted. (iii) Floor door spring, sheet glass, wire clothes, lock etc shall be measured and paid seperately under relevent items
S&F 4mm thick sheet glass, frosted one side and glazing with oil putty in square n-exc. 0.5 sqm in each pane complete all as specified & directed.
S&F sheet glass ordinary quality & glazing on square n exc. 0.5 sqm in each pane 4mm thick complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete as specified and directed.
S&F Anodised aluminium snap grid frame work of size 605x605mm for false ceiling all as specified complete all as specified and as directed.
S&F of 4 mm pre painted Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
M & L for hardcore of gauge n.exc 63mm of broken stone, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in sub base of flooring, etc complete all as specified and directed.
M&L for 40 mm thick, plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in flooring, etc complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finished cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete as specified and directed.
M&L for vitrified ceramic tiles 10 mm thick area of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of the tiles over and including 15mm thick screed bed in CM (1:4) complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of the tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of the tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for Glazed ceramic tiles on vertical surface of size 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of the tiles over and including 10mm thick backing coarse in CM (1:4) complete all as specified and directed.
M&L for coloured glazed ceramic tiles on vertical surface of size 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of the tiles over and including 10mm thick backing coarse in CM (1:4) complete all as specified and directed.
S&F solid PVC door frames of size 50mm X 47mm made out of 5mm plain color PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain color PVC ‘C’ channel having a PVC strip of 20mm width stuck inside with solvent cement for stiles & plain color PVC sheets for top rail, lock rail & bottom rail on either side & gap insert for top rail & bottom rail, paneling of plain color PVC sheet to be fitted in the MS frame, welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent complete all as specified & directed.
S&F 125 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified & directed.
S & F 15 mm dia steel tubing medium grade galvanised, with all fitting and fixed complete to walls, ceiling and laid in floors complete all as specified and directed.
S & F 20 mm dia steel tubing medium grade galvanised, with all fitting and fixed complete to walls, ceiling and laid in floors complete all as specified and directed.
S&F of single piece WC with PP soft close seat cover, hinges, fixing accessories set, cistern fitting, size 360x640x685mm S trap 110mm complete all as specified and directed.
S&F of wall mixer non telephonic shower arrangement with connecting legs and wall flanges complete all as specified and directed.
S&F of table top basin with fixing accessories size 425x345x175mm complete all as specified and directed.
S&F of pillar cock with 200mm extension body complete all as specified and directed.
S&F of bottle trap (with internal partition) 32mm size with 250mm & 190mm low wall connection pipes and wall flange complete all as specified and directed.
S&F of 15mm, 2 way bib cock with flange complete all as specified and directed.
S&F of angular stop cock with wall flange complete all as specified and directed.
S&F Hand shower (health faucet)(ABS Body) with 8mm dia, 1.2 meter long flexible tube & wall hook all as specified and as directed.
S&F of corner glass shelf (with bracket) complete all as specified and directed.
S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
M&L 20 mm thick Granite stone slab (table rubbed and polished) in steps, jambs, pillars, window-cill, cooking plateform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone including grinding and polishing, rounding to edges laid in any position over 15mm thick screed bed in CM 1:4 complete all as specified and as directed
S&F of UPVC pipe (SCH-40) drain pipe 150mm dia laid in trenches and testing after pipes are laid complete all as specified and directed.
S&F of Water closet Pedestal pattern, white including trap and connection to drain pipe, flushing pipe, and anti syphonage pipe, supply & fixing of 10 ltr capacity low level PVC flushing cistern, PVC connection pipe 15mm dia and 600mm long with two check nuts and washer etc complete all as specified and directed.
S&FVitreous china squatting pan, 'Orissa' pattern, size 580 X 440 mm white, with integral foot rests including provision of lime concrete bedding, supply & fixing of 10 ltr capacity low level PVC flushing cistern, flush pipes PVC connection pipe 15mm dia and 600mm long with two check nuts and washer etc in floors complete all as specified and directed.
S & F vitreous China wash basin, white, flat back, single 550 x 400mm excluding taps, waste pipe, chain and plug and porcelain stopper but including brackets, waste coupling, but excluding waste pipe complete all as specified and directed.
Supply and fix of 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F of CP wall mixer for mixing of hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F Chromium plated shower roses with or without swivel joints, including fixing to steel pipe or union CP over head shower of size 125mm of approved make with CP shower arm for wall mounted showers flange complete all as specified and directed.
S&F 15mm bore stop cock/ angle valves brass, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S & F 15 mm bore CP fancy type bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chroumium plated suitable for 8mm dia pipe with 1.20metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S & F Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm, bore of pipe in 32 mm as waste pipe etc complete all as specifed and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints laid in trenches or floors complete as specified and directed.
S&F of 110mm dia PVC (SWR) bends of any radius complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F of 25mm dia mild steel, decorative type, PVC coated curtain rod with brackets complete all as specified and as directed.
S&F of chromium palted Soap dish of approx size 160mmx160mm90mm fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F 600mm long, 20mm dia tubular towel rail, brass, chromium plated with bracket complete as specified and as directed.
S&F 1000 litres capacity rotational moulded polythylene water storage tank (Cylindrical vertical with closed top), hoisted and fixed in position complete all as specified and directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for Concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested in cement concrete 1:3:6 type C2 (using 40mm graded stone aggregates) for 100mm bore pipes complete all as specified and directed.
M&L PCC 1:3:6, Type C-2 (using 40 mm graded stone aggregate) as in surface channel and drain complete as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
INTERNAL ELECTRICATION: M & L for providing Point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVC casing caping of adequate size double locking type but not less than 20mm in width and 1.2mm thick with all fittings and accessories including modular surface box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling including one run 1.5 sqmm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable, 1100 volts grade, green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed for One light/Ceiling/exhaust Fan point controlled by one one/way switch.
All as per item No. 114.00 above but for 5 amp socket point on independent board.
All as per item No. 114.00 above but for 5 amp socket point on same board.
M&L for providing Point wiring with 2.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVC casing caping of adequate size but not less than 20mm in width and 1.2mm thick double locking type with all fittings and accessories including modular surface box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling including one run 2.5 sqmm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable, 1100 volts grade, green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed for 16 amp socket point on independent board.
Supply and fixing modular switch 1 way 6 A, 1 module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed.
Supply and fixing modular switch socket combination 2 in 1, 6A 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked complete all as specified and directed.
Supply and fixing modular switch sockets 6/16A 6 pin combined 3 module 230/250 Volts, 50 Hz , AC supply, ISI Marked complete all as specified and directed.
Supply and fixing modular socket outlet 6A 3 pin 2 module 230/250 Volts, 50 Hz , AC supply, controlled by another 5 amp switch ISI Marked complete all as specified and directed.
S&F ceiling rose surface bakelite two to three terminal 65 x 50mm 250/230 volts ISI marked complete all as specified and directed.
S&F of Factory made distribution board in sheet steel enclosure double door with 200 Amps rated bus bar, SPN, 8 ways, 240 Volts suitable for housing MCBs complete all as specified and directed
S&F MCB, SP, 240 volts, 6-32 Amps 10 KA, C Curve, complete all as specified and as directed
S&F MCB, SPN, 240 volts, C Curve, 40 Amps 10 KA complete all as specified and directed
Supply and fixing LED lights fitting 1x 20W, 230V, lumen output not less than 2000 (4 ft) AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size 23/0.0076 from ceiling rose complete all as specified and directed.
S&F of lamp holder PVC polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F LED ball lamp of 10W with lumen output not less than 900lm and colour temp 6500K complete all as specified and directed.
Supply and fixing LED street light fitting, 15 Watt, 230 V AC, outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp with impact and corrosion resistant including thermal management in multiple optics with including bracket made out of 25mm dia GI pipe light grade approx 0.60m lond complete with IP 65/66 protection completeall as specified and directed
S&F exhaust fan, steel body AC single phase, 230V of size 300mm sweep, 900 RPM with metal bades and frame and louvers complete including cutting holes and making good to match with the existing surface all as specified and directed.
S&F exhaust fan, steel body AC single phase, 230V of size 230mm sweep, 900 RPM with metal bades and frame and louvers complete including cutting holes and making good to match with the existing surface all as specified and directed.
Supply and fixing of ceiling fans 1200mm sweep, BLDC complete with three blade, down rod, accessories 230V, with Squirrel cage induction motor complete all as specified and as directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No. 3 of SSR Part I complete all as specified and directed.
EXTERNAL WATER SUPPLY: S & F 25 mm dia steel tubing medium grade galvanised, with all fitting, laid in trenches/floors complete all as specified and directed.
Supply and fix Gun metal Gate Valves ISI marked of 25 mm bore complete all as specified and directed.
Cutting and insertion of of Tee/ ferrule for taking branch connection complete all as specified and directed.
Supply and fix of ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 25mm bore and fixed complete all as specified and directed.
Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes of size outer dia 25 mm SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete including fittings all as specified and directed.
Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes of size outer dia 50 mm SDR 7.4 (PN-16) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete including fittings all as specified and directed.
Supply and fix PPR Gate Valves (Brass Insert) of 50 mm bore complete all as specified and directed.
Supply and fix PPR Gate Valves (Brass Insert) of 25 mm bore complete all as specified and directed.
Cutting of existing steel tubing for alterations or additions (Each cut measured) without taking down of 100mm dia pipe complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY: Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.00 sq mm 4 core complete all as specified and directed
M & L for providing sand cushioning to UG cable, 8 cm thick laid before laying of cable and 15 cm thick after laying of cable punned down to total thickness of 18 cm in trenches with clean dry sand of approved quality, suitable for sand cushioning complete all as specified and directed. Note: Punned thickness only shall be measured and paid.
M&L for Sub class ‘B’ old size bricks, locally available, laid dry, width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M&L for 40 mm bore GI steel tubing light grade ISI marked for protection of cable including all fittings laid in trenches or fixed on walls/poles with necessary joint and clamps complete all as specified and directed.
WATER COOLER: Supply and install in wall split unit indoor/ outdoor complete with cordless remote control unit and with inbuilt heating and cooling arrangement and digital inverter twin rotary of capacity 1.5 TR complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp capacity complete all as specified and directed
S&F refrigerator electric driven (single phase) of capacity 185 Ltrs, BEE 5 star rated complete all as specified and directed.
S&F voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 5.0 KVA complete all as specified and directed.
S&F of electric water heater storage fine sheet body with upper inner tank and heating element upto 2KW, capacity 25 ltr, BEE 5 Star rate complete with all accessories such as safety valve, thermostat, NRV including connections complete all as specified and directed.
M/S HAMMAS ENTERPRISE (BID ID -3124213)
M/S SEWAK SINGH (BID ID -3122128)
Tarun Deka (BID ID -3132398)
M/S M.S. ENTERPRISE (BID ID -3131855)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .