Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹65.8 L
EMD Value
₹65,810
Closing Date
20 May 2024, 12:00 pmClosed
SE, EUDC-I, NOIDA
33/11 KV SUBSTATION, SECTOR-18 FIRST FLOOR, OPPOSITE SAB MALL, NOIDA
10 WORK IN SYSTEM STRENGTHENING IN DPR 33 CR AS PER Sl NO 16 17 18 19 20 21 22 23 24 25 UNDER EUDD 5 NOIDA
2024_PVVNL_923508_1
146/EUDC-I/2023-24/NOIDA (WORKS)
Open Tender
Electrical Works
Item Rate
IN AREA OF EUDSD-VIII/IX, NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE, EUDD-V, NOIDA
₹65,810
5 Jun 2024
27 Apr 2024
20 May 2024
27 Apr 2024
20 May 2024
27 Apr 2024
Amount
Cartage of following material from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to various points site of work including loading and unloading at both ends : -
Earthing Complete
11 KV Pin Insulator with pin.
11 KV Comp. Poly. Disc Insulator with fitting
ST Pole 11 Mtr. Long. SP-55
ST Pole 9 Mtr. Long. SP-33
11 KV V-type X-Arm
PCC Pole 11 Mtr. Long.
PCC Pole 9 Mtr. Long.
ACSR Dog Conductor
Providing & fixing of following material of standard make / best quality for complete the work of pole structure at HT / LT line as per RESPO norms by the contractor at his own cost : -
Clamp with nut & bolts
Aluminium Crimping lugs 240 Sq.mm.
Repair & Maintenance of damaged LT Feeder Piller Box as per site requirement (Branch Panel) :- (i) Suitable for Kitkat fuse 150A on each phase complete panel. (ii) Plinth repair complete panel. (iii) MCB (250/400A) change complete panel. (iv) Paint, earthing, door welding complete panel.
Welding of damged ST pole as per RESPO complete in all respect.
Grouting & plinthing of pole (Cylendrecal type) of pole after welding as per RESPO complete in all respect..
Removal of conductor from both side spans of damaged pole and removal of H.T/L.T. line accessories from damaged pole.
Digging of pit of damaged pole in Pakka road (Hard soil) with the help of road cutter/digging machine, Tractor etc. for dismantling the pole.
Erection of S.T. pole 11 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule.
Erection of S.T. pole 9 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule.
Erection of PCC pole 11 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule.
Erection of PCC pole 9 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule.
Grouting & concreting of each pole (In ratio of 1:4:8 in Cement, sand and Brick Ballast) in size 450mmx450mmx1800 mm as per RESPO schedule Complete in all respects.
Construction of Plinth in size 450x450x300 mm of each (0.880 Cu.m) pole above the ground level (In ratio of 1:3:6 in Cement, sand and Brick Ballast) as per RESPO schedule Complete in all respects.
Excavation of earth and driving of M.S. earthing rod of size 20x2500 mm in earth and jointing through G.I wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts etc. as per RESPO schedule Complete in all respects.
Re-laying and resagging of conductor in both side spans of erected pole in H.T/L.T line.
Laying, Lifting and final Binding, Sagging of ACSR Dog Conductor including fixing of all accessories as per RESPO schedule Complete in all respects.
Fabrication & fixing of 11 KV V-type X-Arm complete in all respects.
REPLACEMENT OF OLD & DAMAGED LT FEEDER PILLER (BRANCH DISTRIBUTION PANNEL) OF VARIOUS SECTORS IN AREA OF EUDSD-VIII / IX, NOIDA AS PER FOLLOWING :-
Supply of new L.T. Feeder Pillar (Branch Distribution Pannel) as per following specification with all relevant certificate :- 1) LT Feeder Pillar Box (Branch Distribution Pannel) shall be of 14 SWG HR sheet, having (1) doors in front of 14 SWG HR sheet. Doors should have proper locking arrangements with providing crome locks of standard make. It should have a canopy on top in order to prevent it from water ingress in rains. The doors of box should be welded with robust quality hinges and PVC GaskEt with provision of 3 hinges on each door and handle on each door with PVC Gasket. The periphery of door of the LT Feeder Pillar Box (Branch Distribution Pannel) shall be provided with lining of rubber/ PVC to prevent entry of rain, insects, lizards, rats etc. so as to make it vermin proof. 2) The dimension of Feeder Pillar Box (Branch Distribution Pannel) 4(Height) X 2.5(Width) X 2(Depth) Feet (With Canopy). 3) 04 Nos. Bus Bar insulation coated fo size 600x50x10mm. made of aluminum for red, yellow, blue & neutral phases suitable for 250 Amp. 4) 01 No. MCCB of 250 Amp. of L&T / Havell’s / ABB / PVVNL APPROVED make for disconnecting of Supply. 5) 18 Nos. KIT KAT Fuse of 415V, 100 Amp. each capacity tested as per IS shall be provided with 8 Nos. on each phase so as to cater to 8 Nos. 3 Phase connections of conusmer. 6) Aluminum crimping lugs of size 400 / 240 / 120 / 95 / 70Sq.mm. and proper size thimbles shall be provided for safe termination of incomer as well as individual service cable as per qty. requirement. 7) Bakelite sheet shall be provided on the base of channel meant for mounting the Kit Kats. 8) All nuts, bolts & washers used shall be electro galvanized. 9) The height of erected feeder pillar box (Branch Distribution Pannel) approx. 2 feet from the earth on powder coating base of angle iron size 40x40x5mm frame with 04 nos. legs of 3 feet each (1 feet grout of angle on earth bottam, 1.6 feet grout in plinth and 6 inch gap in pannel base and plinth) 10) Grouting & Plinth of Feeder Pillar Box (Branch Distribution Pannel) as per site requirement complete in all respects. 11) The panel case consisting of door and roof (canopy) shall be powder coated with chemical process (weather proof) of Off-white color (Or as per direction) both inside and outside. Before painting, the sun faces shall be thoroughly cleaned from dust, grease and rust. Ientification no. shall be written as per direction. 12) Sundry item.
Disconncetion of all Consumer connection from pannel as per requirement.
Reconncetion of all Consumer connection from pannel after replacement as per requirement.
Installation of above new L.T. Feeder Pillar (Branch Distribution Pannel) in place of damaged L.T. Feeder Pillar (Branch Distribution Pannel) with grouting, plinth and required items complete in all respect.
Dismantling of damaged OLD Feeder Pannel Box from earth on work site.
Carriage of above dismantled Pannel from works site to JE store / central store & proper stacking with loading & unloading.
Providing and installation of LT ACB 400 Amp. with cabinet / structure (L&T, HPL, Schneider, ABB, Hevell's, PVVNL approved make) as per following specification with all relevant certificate :-
400 amp. 03 pole fixed manual ACB.
Red/yellow/blue light indication
ON & OFF Indication
Amp., Volt meter& energy meter digital
Metering C.T 400/5A,
Panel fabrication of size 1250mm x 900mm x 600 mm made of M.S sheet 14 gauge with powder coating with panel lock and key arrangement.(two nos). and additional locking arrangement seprately including providing hut type shape as per drg.
Fabrication of aluminium bus-bar for each phases
Incoming size 425 mm x 50mmx12 mm (twin)
Out going size 720 mm x 50mm x 12 mm(twin)
Neutral size 900mmx50mmx12 mm.
Fabrication of pannel stand made of M.S Angle of size 900mm x 600mm x 500 mm as per drg.
Assembly of above ACB, Indicators, Meters, Metering CT & bus bar arrangment in the panel, fitting the panel on Stand with nut and bolts with wiring etc. & grouting in ratio 1:4:8 with cement, coarse sand and brick blast.
Providing and fixing of aluminium bus bar of size 300mmx60mmx12 mm on L.T side of T/F.
Making all connections with ACB & Distribution T/F and commissioning the ACB complete in all respect.
PROVIDING AND INSTALLATION OF CHEMICAL EARTHING FOR ABOVE NEW L.T. FEEDER PILLAR (BRANCH DISTRIBUTION PANNEL) AND ACB (WITH ALL MATERIAL AND LABOUR) AFTER INSTALLATION RESISTANCE SHOULD BE LESS THAN ONE OHM. AS PER FOLLOWING (The all material and labour shall be provided by the contractor with 12 month guarantee for resistance value less than one OHM.) :-
Providing of earth elctrode for chemical earthing Pipe in pipe type proper hot deep galvanization dia 50 mm length 3 mtr - 32mm x 6mm terminal connection hole dia 8mm The cavity between the pipe & pipe is filled with conductive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be galavanized the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for above new L.T. Feeder Pillar (Branch Distribution Pannel) & ACB.
Providing and fixing of GI strip of size 32 mm x 6 mm suitable for above new L.T. Feeder Pillar (Branch Distribution Pannel) & ACB.
Providing and fixing of PVC Pit covers for above earthing electrode terminals.
Dismantling of old & damaged conductor on work site.
Carriage of above dismantled Conductor from works site to JE store / central store & proper stacking with loading & unloading.
Dismantling of ST Pole (Old & Damaged) on work site.
Carriage of above dismantled pole from works site to JE store / central store & proper stacking with loading & unloading.
Dismantling of ST Pole Scrap on work site.
Carriage of above dismantled pole from works site to JE store / central store & proper stacking with loading & unloading.
Dismantling of LT ACB damaged (Iron Scrap) on work site.
Carriage of above dismantled ACB from works site to JE store / central store & proper stacking with loading & unloading.
Shiva Electricals Company
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .